AL-AHLEIA SWITCHGEAR CO.

, KUWAIT
P.O No.:1003112010 CLIENT: KIPIC SITE :

Equipment / Tag No: REVISION: 1 DATE : PAGE : 1 OF 7

VSD TESTING

Circuit : Panel No:

1.GENERAL DATA AND INFORMATION:


Serial No of VSD:
Type :
Rating:
Input Voltage:
Substation:

Equipment :

2.MOTOR DATA:
Type :
Make:
Power:
Voltage:
Current:
RPM :
Power factor:

TESTED BY WITNESSED BY
Contractor Contractor Company

Name
Signature

Designation
Date
AL-AHLEIA SWITCHGEAR CO., KUWAIT
P.O No.:1003112010 CLIENT: KIPIC SITE :

Equipment / Tag No: REVISION: 1 DATE : PAGE : 2 OF 7

VSD TESTING

Circuit : Panel No:

3. VISUAL INSPECTION:

SN DESCRIPTION CHECKED

Inspect for any physical damage or defect. 

Verify connections as per approved drawing. 

Verify the Earthing as per approved drawing. 


3 TESTED BY WITNESSED BY
Contractor Contractor Company

Name
Signature

Designation
Date
AL-AHLEIA SWITCHGEAR CO., KUWAIT
P.O No.:1003112010 CLIENT: KIPIC SITE :

Equipment / Tag No: REVISION: 1 DATE : PAGE : 3 OF 7

VSD TESTING

Circuit : Panel No:

4. INPUT VOTAGE:
PHASE TO PHASE PHASE TO EARTH

R-Y R-E

Y-B Y-E

R-B B-E

5. ELECTRICAL OPERATIONAL TEST:


Test Run/Direction test: 
ID Run test: 
Motor start from VSD Keypad: 
Motor stop from VSD Keypad: 
Motor start from IMCS: 
TESTED BY WITNESSED BY
Contractor Contractor Company

Name
Signature

Designation
Date
AL-AHLEIA SWITCHGEAR CO., KUWAIT
P.O No.:1003112010 CLIENT: KIPIC SITE :

Equipment / Tag No: REVISION: 1 DATE : PAGE : 4 OF 7

VSD TESTING

Circuit : Panel No:

Motor stop from IMCS: 


Motor speed Control - Analog Input (AI- 2) : 
Motor speed Control – IMCS : 
BI , BO Checks : 
Indication / Alarms Checks : 

6. FAULT TEST

Fault Description Tripping Warning Remarks


Under DC link under 27-AC under voltage is
Voltage voltage proportional to DC link voltage
Under
Power/Curre As per load curve 37-Need load curve of the motor
nt
Thermal
DI6 Circuit Open 49
Over load
AC Over

TESTED BY WITNESSED BY
Contractor Contractor Company

Name
Motor Over Current 51-Drive over current
Signature

Designation
Date
Current
AL-AHLEIA SWITCHGEAR CO., KUWAIT
P.O No.:1003112010 CLIENT: KIPIC SITE :

Equipment / Tag No: REVISION: 1 DATE : PAGE : 5 OF 7

VSD TESTING

Circuit : Panel No:

Locked
Can configure as per
rotor/ 51R/51LR
load
Stalled rotor
DC Fail DC MCB F24 Trip DI 5 Checked

Power fault Q52 MCCB trip DI 2 Checked

7. RE START / RE ACCELERATION TEST:


Description Condition Result

1.Re acceleration Function YES NO


1. power fail < 0.2 to < 4 sec
2. Motor stopped
Result : Motor re acceleration without time delay
immediately

2.Re start Function YES NO Result

1. Under voltage > 4 sec


2. Motor stopped
3. Bus voltage restored after _____ sec
Result
1. Motor re start immediately
2. Motor re start with time delay ______ sec
TESTED BY WITNESSED BY
Contractor Contractor Company

Name
Signature

Designation
Date
AL-AHLEIA SWITCHGEAR CO., KUWAIT
P.O No.:1003112010 CLIENT: KIPIC SITE :

Equipment / Tag No: REVISION: 1 DATE : PAGE : 6 OF 7

VSD TESTING

Circuit : Panel No:

3.Re Start block - I YES NO Result

1. Voltage dip > 30 sec


2. Bus voltage normalized after _____ sec
Result
1. Motor not re started

4. Normal Start YES NO Result

1. Motor Idle Position


2. Voltage (Bus voltage) injected to VSD
Result
1. Motor not started
2. External start command initiated for < 5 sec
3. Motor started with variable speed

TESTED BY WITNESSED BY
Contractor Contractor Company

Name
Signature

Designation
Date
AL-AHLEIA SWITCHGEAR CO., KUWAIT
P.O No.:1003112010 CLIENT: KIPIC SITE :

Equipment / Tag No: REVISION: 1 DATE : PAGE : 7 OF 7

VSD TESTING

Circuit : Panel No:

8. SPEED TEST

Speed from IMCS


Speed Expected (rpm) Speed Actual (rpm)
(rpm)
0
500
1000
1250
1450

9. REMARKS

TESTED BY WITNESSED BY
Contractor Contractor Company

Name
Signature

Designation
Date
AL-AHLEIA SWITCHGEAR CO., KUWAIT
P.O No.:1003112010 CLIENT: KIPIC SITE :

Equipment / Tag No: REVISION: 1 DATE : PAGE : 8 OF 7

VSD TESTING

Circuit : Panel No:

TESTING EQUIPMENT
TYPE CALIBRATION DUE DATE:
USED

TESTED BY WITNESSED BY
Contractor Contractor Company

Name
Signature

Designation
Date