1.0.0 LEGEND:
RV - RECIRCULATION VALVE
DV - DISCHARGE VALVE
SV - SUCTION VALVE
COPYRIGHT AND CONFIDENTIAL
3.0.0 2 x 100% duty Condensate Extraction pumps are provided for this project. These pumps
are meant to draw the condensate from the condenser hot-well and feed it to deaerator
through LP Heaters. Conditions for safe operation of these pumps are specified below.
These shall be kept in view while designing the control circuits and during operation of
the pumps.
Rev No. 5
TD-106-2 PUMPS
Form No.
Rev No. 00
HYDERABAD PAGE 3 of 4
5.1.4 Sealing water is available to the stuffing box (Initially the sealing water is to be
taken from emergency source and subsequently from discharge header when the
pump comes into operation.)
5.1.5 The valve in canister vent line to the condenser is open. This valve should be
locked in OPEN position.
5.1.6 The solenoid valve on discharge vent line to the L.P flash tank is open.
5.2.0 The CEP motor (HM) shall be started provided the following permissive conditions are
The information on this document is the property of BHARAT HEAVY ELECTRICALS LIMITED .
fulfilled:
It must not be used directly or indirectly in any way detrimental to the interest of the company.
pump is started and achieves a pre-set pressure of 19.0 kg/cm2, sensed by pressure
transmitters KKS Tag nos. LCA10 CP022 & 023 (1 OUT OF 2 LOGIC) (provided at the
pump discharge before NRV), discharge valve (DV) of the CEP shall open
automatically.
5.3.2 Solenoid valve on discharge vent line shall be closed with a time delay of 2 minutes
after pump starting.
Rev No. 5
TD-106-2 PUMPS
Form No.
Rev No. 00
HYDERABAD PAGE 4 of 4
8.0.0 During any of the operating conditions the flow handled by the CEP shall not be less
than 125 m3/hr (to be ensured by operation of CEP min RC valve).
LCV10 CT003)
It must not be used directly or indirectly in any way detrimental to the interest of the company.
9.8.0 Discharge valve fail to open : Open limit switch on discharge valve
Discharge valve fail to closed : Close limit switch on discharg valve
9.9.0 CEP Vibration high / very high : LAV10 CY105 & LAV10 CY106
15.0 mm/sec / 25.0 mm/sec
Note
Motor protections are not included in this write up. They shall be as per motor
manufacturer’s recommendations.
**********
Ref. Doc