Professional Documents
Culture Documents
71
www.hilti.com
Company: Page: 1
Address: Specifier:
Phone I Fax: | E-Mail:
Design: CIR-12 Date: 8/6/2021
Fastening point:
Specifier's comments:
1 Input data
Anchor type and diameter: HIT-RE 500 V3 + HAS-V-36 (ASTM F1554 Gr.36) 5/8
Item number: 2198027 HAS-V-36 5/8"x12" (element) / 2123401 HIT-RE
500 V3 (adhesive)
Effective embedment depth: hef,act = 9.000 in. (hef,limit = - in.)
Material: ASTM A 1554 Grade 36
Evaluation Service Report: ESR-3814
Issued I Valid: 3/1/2021 | 1/1/2023
Proof: Design Method ACI 318-19 / Chem
Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.750 in.
Anchor plate :
R lx x ly x t = 20.000 in. x 20.000 in. x 0.750 in.; (Recommended plate thickness: not calculated)
Profile: Round HSS (AISC), HSS10X.625; (L x W x T) = 10.000 in. x 10.000 in. x 0.625 in.
Base material: cracked concrete, 4000, fc' = 4,000 psi; h = 12.000 in., Temp. short/long: 32/32 °F
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: tension: present, shear: present; no supplemental splitting reinforcement present
edge reinforcement: > No. 4 bar
R
- The anchor calculation is based on a rigid anchor plate assumption.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
1
Hilti PROFIS Engineering 3.0.71
www.hilti.com
Company: Page: 2
Address: Specifier:
Phone I Fax: | E-Mail:
Design: CIR-12 Date: 8/6/2021
Fastening point:
11 12
Anchor reactions [kip] 9 10
Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
7 8
1 11.000 1.042 0.000 1.042
2 11.000 1.042 0.000 1.042 x
3 11.000 1.042 0.000 1.042 5 Tension 6
4 11.000 1.042 0.000 1.042
5 11.000 1.042 0.000 1.042
3 4
6 11.000 1.042 0.000 1.042
7 11.000 1.042 0.000 1.042 1 2
8 11.000 1.042 0.000 1.042
9 11.000 1.042 0.000 1.042
10 11.000 1.042 0.000 1.042
11 11.000 1.042 0.000 1.042
12 11.000 1.042 0.000 1.042
Anchor forces are calculated based on the assumption of a rigid anchor plate.
3 Tension load
Load Nua [kip] Capacity f Nn [kip] Utilization bN = Nua/f Nn Status
Steel Strength* 11.000 9.833 112 not recommended
Bond Strength** 132.000 21.497 615 not recommended
Sustained Tension Load Bond Strength* N/A N/A N/A N/A
Concrete Breakout Failure** 132.000 21.295 620 not recommended
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
2
Hilti PROFIS Engineering 3.0.71
www.hilti.com
Company: Page: 3
Address: Specifier:
Phone I Fax: | E-Mail:
Design: CIR-12 Date: 8/6/2021
Fastening point:
Variables
2
Ase,N [in. ] futa [psi]
0.23 58,000
Calculations
Nsa [kip]
13.110
Results
Nsa [kip] f steel f Nsa [kip] Nua [kip]
13.110 0.750 9.833 11.000
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
3
Hilti PROFIS Engineering 3.0.71
www.hilti.com
Company: Page: 4
Address: Specifier:
Phone I Fax: | E-Mail:
Design: CIR-12 Date: 8/6/2021
Fastening point:
Nag = (AA ) y
Na
Na0
ec1,Na y ec2,Na y ed,Na y cp,Na Nba ACI 318-19 Eq. (17.6.5.1b)
f Nag ³ Nua ACI 318-19 Table 17.5.2
ANa see ACI 318-19, Section 17.6.5.1, Fig. R 17.6.5.1(b)
2
ANa0 = (2 cNa) ACI 318-19 Eq. (17.6.5.1.2a)
t uncr
cNa = 10 da √ 1100
ACI 318-19 Eq. (17.6.5.1.2b)
( )
1
'
y ec,Na = eN £ 1.0 ACI 318-19 Eq. (17.6.5.3.1)
1+
cNa
Na
ACI 318-19 Eq. (17.6.5.4.1b)
= MAX(
c ) £
c c a,min Na
y cp,Na , 1.0 ACI 318-19 Eq. (17.6.5.5.1b)
c ac ac
Nba = l a · t k,c · p · da · hef ACI 318-19 Eq. (17.6.5.2.1)
Variables
t k,c,uncr [psi] da [in.] hef [in.] ca,min [in.] aoverhead t k,c [psi]
2,486 0.625 9.000 4.339 1.000 1,352
Calculations
cNa [in.] ANa [in. ]
2
ANa0 [in. ]
2
y ed,Na
9.353 577.12 349.88 0.839
Results
Nag [kip] f bond f Nag [kip] Nua [kip]
33.073 0.650 21.497 132.000
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
4
Hilti PROFIS Engineering 3.0.71
www.hilti.com
Company: Page: 5
Address: Specifier:
Phone I Fax: | E-Mail:
Design: CIR-12 Date: 8/6/2021
Fastening point:
Ncbg = (AA ) y
Nc
Nc0
ec,N y ed,N y c,N y cp,N Nb ACI 318-19 Eq. (17.6.2.1b)
f Ncbg ³ Nua ACI 318-19 Table 17.5.2
ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b)
2
ANc0 = 9 hef ACI 318-19 Eq. (17.6.2.1.4)
( )
1
'
y ec,N = 2 eN £ 1.0 ACI 318-19 Eq. (17.6.2.3.1)
1+
3 hef
ef
ACI 318-19 Eq. (17.6.2.4.1b)
= MAX(
c ) £
c 1.5h a,min ef
y cp,N , 1.0 ACI 318-19 Eq. (17.6.2.6.1b)
c ac ac
1.5
Nb = kc l a √ '
fc hef ACI 318-19 Eq. (17.6.2.2.1)
Variables
hef [in.] ec1,N [in.] ec2,N [in.] ca,min [in.] y c,N
4.468 0.000 0.000 4.339 1.000
'
cac [in.] kc la fc [psi]
25.727 17 1.000 4,000
Calculations
ANc [in. ]
2
ANc0 [in. ]
2
y ec1,N y ec2,N y ed,N y cp,N Nb [kip]
561.81 179.67 1.000 1.000 0.894 1.000 10.154
Results
Ncbg [kip] f concrete f Ncbg [kip] Nua [kip]
28.394 0.750 21.295 132.000
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
5
Hilti PROFIS Engineering 3.0.71
www.hilti.com
Company: Page: 6
Address: Specifier:
Phone I Fax: | E-Mail:
Design: CIR-12 Date: 8/6/2021
Fastening point:
4 Shear load
Load Vua [kip] Capacity f Vn [kip] Utilization bV = Vua/f Vn Status
Steel Strength* 1.042 5.112 21 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength (Concrete Breakout 12.500 39.751 32 OK
Strength controls)**
Concrete edge failure in direction y+** 12.500 5.517 227 not recommended
Variables
2
Ase,V [in. ] futa [psi]
0.23 58,000
Calculations
Vsa [kip]
7.865
Results
Vsa [kip] f steel f Vsa [kip] Vua [kip]
7.865 0.650 5.112 1.042
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
6
Hilti PROFIS Engineering 3.0.71
www.hilti.com
Company: Page: 7
Address: Specifier:
Phone I Fax: | E-Mail:
Design: CIR-12 Date: 8/6/2021
Fastening point:
Nc0
ec,N y ed,N y c,N y cp,N Nb ] ACI 318-19 Eq. (17.7.3.1b)
f Vcpg ³ Vua ACI 318-19 Table 17.5.2
ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b)
2
ANc0 = 9 hef ACI 318-19 Eq. (17.6.2.1.4)
( )
1
'
y ec,N = 2 eN £ 1.0 ACI 318-19 Eq. (17.6.2.3.1)
1+
3 hef
ef
ACI 318-19 Eq. (17.6.2.4.1b)
= MAX(
c ) £
c 1.5h
a,min ef
y cp,N , 1.0 ACI 318-19 Eq. (17.6.2.6.1b)
c ac ac
1.5
Nb = kc l a √ '
fc hef ACI 318-19 Eq. (17.6.2.2.1)
Variables
kcp hef [in.] ec1,N [in.] ec2,N [in.] ca,min [in.]
2 4.468 0.000 0.000 4.339
'
y c,N cac [in.] kc la fc [psi]
1.000 25.727 17 1.000 4,000
Calculations
ANc [in. ]
2
ANc0 [in. ]
2
y ec1,N y ec2,N y ed,N y cp,N Nb [kip]
561.81 179.67 1.000 1.000 0.894 1.000 10.154
Results
Vcpg [kip] f concrete f Vcpg [kip] Vua [kip]
56.787 0.700 39.751 12.500
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
7
Hilti PROFIS Engineering 3.0.71
www.hilti.com
Company: Page: 8
Address: Specifier:
Phone I Fax: | E-Mail:
Design: CIR-12 Date: 8/6/2021
Fastening point:
Vcbg = (AA ) y
Vc
Vc0
ec,V y ed,V y c,V y h,V y parallel,V Vb ACI 318-19 Eq. (17.7.2.1b)
f Vcbg ³ Vua ACI 318-19 Table 17.5.2
AVc see ACI 318-19, Section 17.7.2.1, Fig. R 17.7.2.1(b)
2
AVc0 = 4.5 ca1 ACI 318-19 Eq. (17.7.2.1.3)
( )
1
'
y ec,V = ev £ 1.0 ACI 318-19 Eq. (17.7.2.3.1)
1+
1.5ca1
y h,V = √1.5ca1
h ³ 1.0
a
ACI 318-19 Eq. (17.7.2.6.1)
(7 (dl ) )l
0.2
Vb = e
√ da a √f'c c1.5
a1 ACI 318-19 Eq. (17.7.2.2.1a)
a
Variables
ca1 [in.] ca2 [in.] ecV [in.] y c,V ha [in.]
4.339 9.388 0.000 1.200 12.000
'
le [in.] la da [in.] fc [psi] y parallel,V
5.000 1.000 0.625 4,000 1.000
Calculations
AVc [in. ]
2 2
AVc0 [in. ] y ec,V y ed,V y h,V Vb [kip]
108.32 84.73 1.000 1.000 1.000 4.795
Results
Vcbg [kip] f concrete f Vcbg [kip] Vua [kip]
7.356 0.750 5.517 12.500
5 Combined tension and shear loads, per ACI 318-19 section 17.8
bN bV z Utilization bN,V [%] Status
6.199 2.266 1.000 706 not recommended
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
8
Hilti PROFIS Engineering 3.0.71
www.hilti.com
Company: Page: 9
Address: Specifier:
Phone I Fax: | E-Mail:
Design: CIR-12 Date: 8/6/2021
Fastening point:
6 Warnings
• The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2018, ETAG 001/Annex C,
EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the
anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates
the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The
proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for
agreement with the existing conditions and for plausibility!
• Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential
concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout
or pryout strength governs.
• Design Strengths of adhesive anchor systems are influenced by the cleaning method. Refer to the INSTRUCTIONS FOR USE given in the
Evaluation Service Report for cleaning and installation instructions.
• For additional information about ACI 318 strength design provisions, please go to https://submittals.us.hilti.com/PROFISAnchorDesignGuide/
• Installation of Hilti adhesive anchor systems shall be performed by personnel trained to install Hilti adhesive anchors. Reference ACI 318-19,
Section 26.7.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
9
Hilti PROFIS Engineering 3.0.71
www.hilti.com
Company: Page: 10
Address: Specifier:
Phone I Fax: | E-Mail:
Design: CIR-12 Date: 8/6/2021
Fastening point:
7 Installation data
Anchor type and diameter: HIT-RE 500 V3 + HAS-V-36
(ASTM F1554 Gr.36) 5/8
Profile: Round HSS (AISC), HSS10X.625; (L x W x T) = 10.000 in. x 10.000 in. Item number: 2198027 HAS-V-36 5/8"x12" (element) /
x 0.625 in. 2123401 HIT-RE 500 V3 (adhesive)
Hole diameter in the fixture: df = 0.687 in. Maximum installation torque: 0.06000 ft.kip
Plate thickness (input): 0.750 in. Hole diameter in the base material: 0.750 in.
Recommended plate thickness: not calculated Hole depth in the base material: 9.000 in.
Drilling method: Hammer drilled Minimum thickness of the base material: 10.500 in.
Cleaning: Compressed air cleaning of the drilled hole according to instructions
for use is required
5/8 Hilti HAS Carbon steel threaded rod with Hilti HIT-RE 500 V3
y
10.000 10.000
3.138 1.811 3.239
11 12
10.000
9 10
7 8
3.624
x
5 6
3.239 1.811 3.138
10.000
3 4
1 2
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
10
Hilti PROFIS Engineering 3.0.71
www.hilti.com
Company: Page: 11
Address: Specifier:
Phone I Fax: | E-Mail:
Design: CIR-12 Date: 8/6/2021
Fastening point:
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
11
Hilti PROFIS Engineering 3.0.71
www.hilti.com
Company: Page: 12
Address: Specifier:
Phone I Fax: | E-Mail:
Design: CIR-12 Date: 8/6/2021
Fastening point:
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
12