You are on page 1of 39

Provision of EPCI Services for

West Pangkah Process Facilities

West Pangkah Field Development

CALCULATION FOR KO DRUM PLATFORM


STRUCTURE

Client : Saka Indonesia Pangkah Limited


Contract No. : 4600012823
Document No. : UPD-ME-W7-CI-CL-4103

Client
Revision Date Description Originator Checker Approver
Approval

JK SD
B 24-08-2020 Issued For Review DH
DY NA/YS
JK SD
C 08-09-2020 Issued For Approval DH
DY NA/YS
JK SD
0 18-09-2020 Approved For Construction DH DY NA/YS
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

RECORD OF REVISION

Rev. Incorporated
Section Page Company Comment Contractor Response
No. (Y/N)

to check with mechanical as


M12 is not adequate to
in this calculation the bolt
withstand loading occuring. New
Cover, dimensions on support clip is
C Cover N holes for M20 can be created by
Att. D designed as M20, however in
boring to the gusset plates
actual the bolt hole available
attached to the vessel.
is for M12
C 1.2 6 delete Y Comply
substitute into: KO Drum
Platform structure is
C 1.2 6 designed in accordance with Y Comply
the clip connection as
provided by the VENDOR.
specify The Load obtained
C 3.3 12 from the pipe stress analysis Y Comply
(using table)
there are 4 EA piping line
C 3.3 12, 14 supported by this support, Y Comply
please specify the others
specify The Load obtained
C 3.3 13 from the pipe stress analysis Y Comply
(using table)
Please add piping load due
14, Att to line 3"-VA-43013-D01B/B
C 3.3 Y Comply
C and line 3"-VA-43013-
D01B/B2
WH profile beam is needed to
to use SH profile for beam
C 5.1 21 N robustly support the platform
instead of WH beam
and to minimize the size.
Please add: design
restrictions are applied to
C 2.6.3 10 avoid direct welding and/or Y Comply
bolting to Gas Lift KO Drum's
vessel.

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 2 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

TABLE OF CONTENT

1. INTRODUCTION .................................................................................................................................. 5
1.1 General ....................................................................................................................................... 5
1.2 Objective and Scope ................................................................................................................... 6
1.3 Design Life .................................................................................................................................. 6
1.4 Definition of Terms ...................................................................................................................... 6
2. GENERAL PARAMETER ..................................................................................................................... 7
2.1 Reference, Code and Standard ................................................................................................... 7
2.2 Unit ............................................................................................................................................. 7
2.3 Abbreviations .............................................................................................................................. 8
2.4 Quality of Material ....................................................................................................................... 9
2.5 Unit Weight of Material .............................................................................................................. 10
2.6 Design Criteria .......................................................................................................................... 10
3. DESIGN LOADING ............................................................................................................................ 11
3.1 Dead Load (D)........................................................................................................................... 11
3.2 Equipment Load (E(E), E(O), E(T)) ........................................................................................... 11
3.3 Piping Load (P(E), P(O), P(T)) .................................................................................................. 11
3.4 Live Load (L) ............................................................................................................................. 13
3.5 Wind Load (W) .......................................................................................................................... 13
3.6 Earthquake Load (EQ) .............................................................................................................. 17
4. LOAD COMBINATION ....................................................................................................................... 18
5. CONCLUSION ................................................................................................................................... 20
5.1 Unity Check of Stress Results ................................................................................................... 20
5.2 Unity Check of Deflection Results ............................................................................................. 23
5.3 Connection Design Results ....................................................................................................... 26

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 3 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

LIST OF FIGURE
Figure 1.1 West Pangkah Wellsite Location................................................................................................. 6
Figure 5.1 KO Drum Platform Structure 3D Model ..................................................................................... 20
Figure 5.2 KO Drum Platform Member ID EL+5.281 to EL+5.735.............................................................. 21
Figure 5.3 KO Drum Platform Node ID EL+5.281 to EL+5.735 .................................................................. 23
Figure 5.4 Bracing Bolted Connection ....................................................................................................... 26
Figure 5.5 Bracing Bolted Connection ....................................................................................................... 28

LIST OF TABLE
Table 2.1 Reference, Code and Standards .................................................................................................. 7
Table 2.2 Material Quality ............................................................................................................................ 9
Table 2.3 Material Unit Weight................................................................................................................... 10
Table 4.1 Loading Combination ASD ......................................................................................................... 18
Table 5.1 Summary of Maximum Stress UC .............................................................................................. 21
Table 5.2 Summary of Maximum Deflection UC ........................................................................................ 24
Table 5.3 Bracing Bolted Connection Capacity .......................................................................................... 26
Table 5.4 Bracing Bolted Connection Capacity .......................................................................................... 28
Table 5.5 Basic Load Support Reaction Summary..................................................................................... 30
Table 5.6 Basic Load ID Definition ............................................................................................................. 33
Table 5.7 Unfactored Load Combination Support Reaction Summary ....................................................... 34

Attachment A Staad Pro Input File


Attachment B Staad Pro Output File
Attachment C Design Loading
Attachment D Connection Design Calculation
Attachment E Drawings
Attachment F Equipment Data

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 4 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

1. INTRODUCTION

1.1 General

SAKA Indonesia Pangkah Limited/SIPL (herein referred as COMPANY) has been


commissioned to undertake the operator of Ujung Pangkah Block in East Java since January
2014 from HESS. The Ujung Pangkah field is located offshore off the north coast of East Java
approximately 35 km north of Gresik, East Java, Indonesia; lies adjacent to the Bengawan Solo
river delta.
WHP-A currently producing natural gas and crude oil and then the fluid is transported to CPP
near WHP-B for separation and compression/pumping process. WHP-B producing oil and gas,
then the produced fluid are transferred to CPP for separation and compression/pumping
process. The outlet of oil and gas separation process at CPP will be transported via 16” Export
Pipeline to WHP-A, and continued with 18” Export Pipeline from WHP-A to Onshore Processing
Facility (OPF) in Gresik.
COMPANY intends to proceed with Development of the West Pangkah Field which is part of the
Ujung Pangkah Block. West Pangkah Field lies on a transition zone with water depth variation
between 0 to -5 meter and around 5 km away from COMPANY WHP-B/CPP existing facilities.
The development plan of West Pangkah Field is to construct one (1) onshore well pad facility
with six (6) well slots as well as production and utility facilities. The production from West
Pangkah Field will be commingled with Pangkah's production facility at WHP-B/CPP then
delivered to COMPANY Onshore Processing Facility (OPF) in Gresik for further processing.

In summary, West Pangkah Field Development consists of the following major components:
a) Onshore wellsite facility
b) Production pipeline & gas lift pipeline
c) Modification of the existing facilities (WHP-B & AUP) to accommodate West Pangkah’s
production and support West Pangkah’s production systems
In the OPF all product will continue further process to separate oil, gas, LPG and water. The oil
product will be transferred via pipeline to Maspion Jetty ready for shipping. The further process
is liquefaction to convert heavy fraction becomes LPG and the low fraction becomes Sales Gas.
The Sales Gas will be transported to PLN at PJB via 20” Onshore Sales Gas Pipeline.
The West Pangkah Field location as part of the Ujung Pangkah Block is shown on Figure 1.1.

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 5 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

Figure 1.1 West Pangkah Wellsite Location

1.2 Objective and Scope

The purpose of this document is to present the calculation of KO Drum Platform Structure for
West Pangkah Field Development Project. KO Drum Platform Structure is designed in
accordance with the clip connection as provided by VENDOR. The structural analysis is static
analysis with vertical loads applied are in accordance with Ref. [1] and Ref. [2] whereas the
lateral loads aplied are in accordance with Ref. [2], Ref. [4] and Ref. [5]. Furthermore, the
design of steel structure is in accordance with Ref. [3].

1.3 Design Life

The design life of West Pangkah wellsite facilities and all associated equipment, component and
system is fifteen (15) years.

1.4 Definition of Terms

COMPANY Saka Indonesia Pangkah Limited


CONTRACTOR Any organizations that appointed to provide services as defined in
a legal contract issued by COMPANY
SUBCONTRACTOR/ Party which supplies equipment/materials or services specified and
VENDOR/SUPPLIER ordered by CONTRACTOR (or COMPANY)
MANUFACTURER Party which manufactures equipment/materials specified and
ordered by CONTRACTOR (or COMPANY)

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 6 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

2. GENERAL PARAMETER
The followings present the summary of the calculation for KO Drum Platform Structure.

2.1 Reference, Code and Standard

All work shall be carried out in compliance with the following Specification, Codes, Standards
and references unless otherwise noted. The following code, standard and references shall be
used throughout the document:

Table 2.1 Reference, Code and Standards

No. Description Remarks

1. UPD-SE-G9-CI-BD-4001 Design Basis for Civil and Underground Structure

2. ASCE 7-10 Minimum Design Loads for Building and Other Structures

3. AISC ASD 9th Ed. American Institute of Steel Construction Allowable Stress
Design

4. SNI-03-1726-2012 Indonesian Seismic Code for Building Structure

5. IBC 2006 International Building Code 2006

6. - Final Report Survey Topography, Geoteknik, Geomagnet,


Ujung Pangkah Gresik

7. UPD-PTG-W7-GE-GA-0002 General Arrangement Gas Lift KO Drum

8. UPD-ME-W7-CI-DR-4106 KO Drum Platform Structure Plan Elevation and Details

9. ASME B.36.10M/19M-2015 Welded and Seamless Wrought Steel Pipe

2.2 Unit
All units are in SI units unless noted otherwise.

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 7 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

2.3 Abbreviations
The following abbreviations are applied throughout the document:
D Dead Load
L Live Load
E Equipment Load
W Wind Load
V Basic Wind Speed
Kd Wind Directionality Factor
Kz Velocity Exposure Coefficient
Kzt Topographic Factor
I Importance Factor
qz Wind Pressure
G Gust Effect Factor
Cf Wind Force Coefficient
p Design Wind Pressure
F Wind Force
Aw Projected Area
EQ Earthquake Load
Ss Response Acceleration at Short Period
S1 Response Acceleration at 1s
Sms Parameter Response Spectra at Short Period (t=0.2s) at Site Condition
Sm1 Parameter Response Spectra at 1s (t=1s) at Site Condition
SDs Design Response Spectra at Short Period (t=0.2s) at Site Condition
SD1 Design Response Spectra at 1s (t=1s) at Site Condition
Fa Site Coefficient
Fv Site Coefficient
Wt Weight of Equipment or Structure
R Reduction Factor
T Fundamental Period
TF Thermal Friction
Cs Seismic Coefficient
Vs Shear Force
M Bending Moment
UPD-ME-W7-CI-CL-4103_Rev. 0 Page 8 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

Ts Tension Force
C Compression Force
Tsall Allowable Tensile Force
Call Allowable Compression Force
Mall Allowable Moment
Ts1 Allowable Tension Capacity of Member
Ts2 Allowable Tension Capacity of Beam Welding
Ts3 Allowable Tension Capacity of Connecting Plate Welding
Vs1 Allowable Shear Capacity of Member
Vs2 Allowable Shear Capacity of Beam Welding
Vs3 Allowable Shear Capacity of Plate Welding
Vs4 Allowable Shear Capacity of Plate Rupture
M1 Allowable Moment Capacity of Member
M2 Allowable Moment Capacity of Tensile Beam Welding
M3 Allowable Moment Capacity of Connecting Plate Welding
M4 Allowable Moment Capacity of Base Plate
C2 Compression Capacity of Base Plate Yielding
kN kiloNewton
kNm kiloNewton-meter

2.4 Quality of Material


The following Table shows the material quality used in the document:

Table 2.2 Material Quality

No. Material Symbol Strength Unit Standard

1. Steel Structure Fy 245 MPa SS400

2 Weld Electrode Fu 483 MPa AWS A5.1 E70XX

3 High Strength Bolt Fu 827 MPa ASTM A325

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 9 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

2.5 Unit Weight of Material


The following Table shows the material unit weight used in the document:

Table 2.3 Material Unit Weight

No. Material Symbol Weight Unit

1. Steel Structure steel 77.3 kN/m3

2.6 Design Criteria


The Calculation For KO Drum Platform Structure is considering Unity Check of Stress, Unity
Check of Deflection and Connection Design as the main Design Criteria.

2.6.1 Unity Check of Stress


Ref[3] is used to perform Stress Unity Check that is already built in in Staad Pro V8i by invoking the
Code in the script input file. All failure modes with regards to Ref[3] are checked automatically and
the worst values of Stress Unity Check for each member are presented.

2.6.2 Unity Check of Deflection


The Deflection Limits set in Ref[1] are defined within Staad Pro V8i using Defined Joint and
Deflection Limit script in the input file. All deflections are checked automatically against the
Deflection Limit and the Results are tabulated as Unity Check Deflection. For column the maximum
limit of deflection is Height/200, for beam Span/360 and for cantilever beam the limit is Span/240.

2.6.3 Connection Design


Welded and bolted connections are considered in this calculation. The connection capacity is the
lesser of welding capacity, member capacity, connecting plate capacity and bolt capacity. The detail
of connection design is presented in Attachment D. The capacities of structural connections are
based on Ref[3]. The restriction is applied to avoid direct welding and/or bolting to the body of the
Vessel.

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 10 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

3. DESIGN LOADING
The following forces and loads are considered in this calculation. The detail of forces and loads are
presented in Attachment C.

3.1 Dead Load (D)


This load consists of modelled weight of the structure such as KO Drum Platform Structure. A
contingency of 15% is applied for dead load in the load combination. For selfweight modelled load,
an allowance of 10% increase is adopted to cater for connection weight.

3.1.1 Modelled Dead Load


Staad Pro V8i automatically calculates the loading generated by the structure that is modelled in the
software. For selfweight modelled load, an allowance of 10% increase is adopted to cater for
connection weight. A contingency of 15% is applied for modelled dead load in the load combination.

3.1.2 Superimposed Dead Load


There Superimposed Dead Load consists of gratings with a magnitude of 0.49 kPa, handrail with a
magnitude of 0.49 kN/m.

3.2 Equipment Load (E(E), E(O), E(T))


There is no Equipment Load considered in this calculation.

3.3 Piping Load (P(E), P(O), P(T))


Piping load considered in this calculation is derived from pipe stress run provided by piping
discipline as well as estimated piping load from Ref.[9]. The following figures show the support
reactions provided by piping discipline.The application of the load to Staad Pro model is shown in
Attachment C.

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 11 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

Figure 3.1 Piping Load Nodes on KO Drum Platform Structure

Table 3.1 Piping Load Node 160, 165, 22


Node 160 165 22
Diameter 4" 4" 3"
Line ID PG-04008-B09B/B1 PG-04003-B09B/B1 VA-43013-D01B/B1
Load vert. (kN) 0.675 0.675 0.33
Load Long. (kN) 0.13 0.13 0
Load Trans. (kN) 0.098 0.098 0

Table 3.2 Piping Load Node 160, 161, 23


Node 23 162 161
Diameter 2" 2" 2"
Line ID PG-04007-B09B/B1 DC-44022-B09B/B1 PL-04004-B09B/B1
Load vert. (kN) 0.67 0.197 0.197
Load Long. (kN) 0 0 0
Load Trans. (kN) 0 0 0

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 12 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

Table 3.3 Piping Load Node 24, 25, 26


Node 24 25 26
Diameter 2" 2" 3"
Line ID PG-04007-B09B/B1 PG-04007-B09B/B1 VA-43013-D01B/B2
Load Vert. (kN) 0.94 0.65 1.55
Load Long. (kN) 0 0 0
Load Trans. (kN) 0 0 0

3.4 Live Load (L)


Live Load with a magnitude of 5 kPa is considered in this calculation.

3.5 Wind Load (W)


The Wind load shall be calculated in accordance with the formula as given in ASCE Standard
ASCE/SEI 7-10 (Minimum Design Loads for Buildings and Other Structure) Section 26. The Wind
Load considered is applied to the structure and to pipes as well. The detail application of wind load
to structure and to pipes is shown in Attachment C.

3.5.1 Wind Load applied to the KO Drum Platform Structure

Structure Category = IV
Exposure Category = C
Enclosure Classification = Open Structure

Kz Velocity Pressure Exposure Coefficient = 0.90 (4.1-6.1m)

Kzt Topographic Factor = 1.00


Kd Wind Directionality Factor = 0.95
V Wind Velocity, m/s = 37.3 m/s

Velocity Pressure (qz) input as intensity in Staad Pro = 0.613 x Kz x Kzt x Kd x V2


= 729 N/m2 (4.1 to 6.1m)
= 0.729 kN/m2 (4.1 to 6.1m)

Wind Pressure Coefficient

G = Gust effect factor = 0.85


h = Height equipment above ground level = 6187mm
h/D = 6187/125 = 49.5
Cf = Force coefficient = 2.0
G Cf = 2.0 x 0.85
= 1.7

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 13 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

The Wind Load to the Structure is automatically calculated by Staad Pro V8i from the velocity
pressure intensity definition and the cross section of the member. The G Cf value of 1.7 is input in
the Load Condition factor so that the velocity pressure defined previously is automatically multiplied
by Staad Pro V8i and applied to the members.

3.5.2 Wind Load applied to Pipe Node 160 & 165 (4 inch STD 40)

Structure Category = IV
Exposure Category = C
Enclosure Classification = Open Structure

Kz Velocity Pressure Exposure Coefficient = 0.90 (4.1-6.1m)

Kzt Topographic Factor = 1.00


Kd Wind Directionality Factor = 0.95
V Wind Velocity, m/s = 37.3 m/s

Velocity Pressure (qz) input as intensity in Staad Pro = 0.613 x Kz x Kzt x Kd x V2


= 729 N/m2 (4.1 to 6.1m)
= 0.729 kN/m2 (4.1 to 6.1m)

Wind Pressure Coefficient

G = Gust effect factor = 0.85


h = Height equipment above ground level = 5735mm
h/D = 5735/114.3 = 50.17
Cf = Force coefficient = 1.2
Dqz 0.5 = 0.1143*729 0.5 = 3.086
p = wind pressure = 0.74 kPa

Z direction (EL.4.1-6.1m)
Symbol Description Value Unit
Awz wind load area at X direction = 1.2*H*L 0.30 m2
WZ design wind load at X direction = p*Awz 0.224 kN

3.5.3 Wind Load applied to Pipe Node 185 and Other Pipes (2 inch STD 40)

Structure Category = IV
Exposure Category = C
Enclosure Classification = Open Structure

Kz Velocity Pressure Exposure Coefficient = 0.90 (4.1-6.1m)

Kzt Topographic Factor = 1.00


Kd Wind Directionality Factor = 0.95
V Wind Velocity, m/s = 37.3 m/s

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 14 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

Velocity Pressure (qz) input as intensity in Staad Pro = 0.613 x Kz x Kzt x Kd x V2


= 729 N/m2 (4.1 to 6.1m)
= 0.729 kN/m2 (4.1 to 6.1m)

Wind Pressure Coefficient

G = Gust effect factor = 0.85


h = Height equipment above ground level = 5735mm
h/D = 5735/60.3 = 95.11
Cf = Force coefficient = 1.2
Dqz 0.5 = 0.0603*729 0.5 = 1.628
p = wind pressure = 0.74 kPa

X direction (EL. 4.1-6.1m)


Symbol Description Value Unit
Awx wind load area at X direction = 1.2*H*L 0.17 m2
WX design wind load at X direction = p*Awx 0.124 kN

3.5.4 Wind Load applied to Pipe Node 185 and Other Pipes (3 inch STD 40)

Structure Category = IV
Exposure Category = C
Enclosure Classification = Open Structure

Kz Velocity Pressure Exposure Coefficient = 0.90 (4.1-6.1m)

Kzt Topographic Factor = 1.00


Kd Wind Directionality Factor = 0.95
V Wind Velocity, m/s = 37.3 m/s

Velocity Pressure (qz) input as intensity in Staad Pro = 0.613 x Kz x Kzt x Kd x V2


= 729 N/m2 (4.1 to 6.1m)
= 0.729 kN/m2 (4.1 to 6.1m)

Wind Pressure Coefficient

G = Gust effect factor = 0.85


h = Height equipment above ground level = 5735mm
h/D = 5735/88.9 = 64.51
Cf = Force coefficient = 1.2
Dqz 0.5 = 0.0889*729 0.5 = 2.4
p = wind pressure = 0.74 kPa

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 15 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

X direction (EL. 4.1-6.1m)


Symbol Description Value Unit
Awx wind load area at X direction = 1.2*H*L 0.79 m2
WX design wind load at X direction = p*Awx 0.587 kN

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 16 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

3.6 Earthquake Load (EQ)


Earthquake Load is considered in this calculation to cater for maximum probable ground
acceleration that would occur within the design life with a projected magnitude exceeding 2% within
50 years. The following parameters are the site specific coefficient at West Pangkah location. The
Seismic Load is simulated automatically by Staad Pro V8i using similar Code which is IBC 2006
equivalent to Ref[4]. The access platform is designed separately from KO Drum since the access
platform is supported by KO Drum so that this is the worst scenario.

Ss = 0.59g
S1 = 0.20g
Fa = 1.52
Fv = 3.20
I = 1.00 (Table 2 Ref[4])
R = 2.5 (Table 19 Ref [4] for Pressure Vessel)
Soil type = Soft Soil (SE)

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 17 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

4. LOAD COMBINATION
The subsequent Table shows the Load Combinations used in this calculation based on Ref[1].

Table 4.1 Loading Combination ASD

LC Decription Increase in Remarks


No. allowable stress

101 1.15D + L + 1.15E(E) + 1.15P(E) 1.00 Permanent


102 1.15D + L + 1.15E(E) + 1.15P(E) + WX 1.33 Temporary
103 1.15D + L + 1.15E(E) + 1.15P(E) + WZ 1.33 Temporary
104 1.15D + L + 1.15E(E) + 1.15P(E) + EQ(E)X 1.33 Temporary
105 1.15D + L + 1.15E(E) + 1.15P(E) + EQ(E)Z 1.33 Temporary
106 1.15D + L + 1.15E(E) + 1.15P(E) + EQ(O)X 1.33 Temporary
107 1.15D + L + 1.15E(E) + 1.15P(E) + EQ(O)Z 1.33 Temporary
108 1.15D + 1.15E(E) + 1.15P(E) + WX 1.33 Temporary
109 1.15D + 1.15E(E) + 1.15P(E) + WZ 1.33 Temporary
110 1.15D + 1.15E(E) + 1.15P(E) + EQ(E)X 1.33 Temporary
111 1.15D + 1.15E(E) + 1.15P(E) + EQ(E)Z 1.33 Temporary
112 1.15D + 1.15E(E) + 1.15P(E) + EQ(O)X 1.33 Temporary
113 1.15D + 1.15E(E) + 1.15P(E) + EQ(O)Z 1.33 Temporary
114 1.15D + L + 1.15P(O) + 1.15E(O) 1.00 Permanent
115 1.15D + 0.5 L + 1.15E(O) + 1.15P(O) + WX 1.33 Temporary
116 1.15D + 0.5 L + 1.15E(O) + 1.15P(O) + WZ 1.33 Temporary
117 1.15D + 0.5 L + 1.15E(O) + 1.15P(O) + EQ(E)X 1.33 Temporary
118 1.15D + 0.5 L + 1.15E(O) + 1.15P(O) + EQ(E)Z 1.33 Temporary
119 1.15D + 0.5 L + 1.15E(O) + 1.15P(O) + EQ(O)X 1.33 Temporary
120 1.15D + 0.5 L + 1.15E(O) + 1.15P(O) + EQ(O)Z 1.33 Temporary
121 1.15D + 1.15E(O) + 1.15P(O) + WX 1.33 Temporary
122 1.15D + 1.15E(O) + 1.15P(O) + WZ 1.33 Temporary
123 1.15D + 1.15E(O) + 1.15P(O) + EQ(E)X 1.33 Temporary
124 1.15D + 1.15E(O) + 1.15P(O) + EQ(E)Z 1.33 Temporary
125 1.15D + 1.15E(O) + 1.15P(O) + EQ(O)X 1.33 Temporary
126 1.15D + 1.15E(O) + 1.15P(O) + EQ(O)Z 1.33 Temporary

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 18 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

LC Decription Increase in Remarks


No. allowable stress

127 1.15D + 1.15E(O) + 1.15P(O) 1.00 Permanent


128 1.15D + 0.5 L + 1.15E(T) + 1.15P(T) 1.33 Temporary
129 1.15D + 0.5 L + 1.15E(T) + 1.15P(T)+ 0.25 WX 1.33 Temporary
130 1.15D + 0.5 L + 1.15E(T) + 1.15P(T)+ 0.25 WZ 1.33 Temporary
131 1.15D + 1.15E(E) + 1.15P(E) 1.00 Permanent
Note: 1.15 factor is used to simulate a contingency of 15% applied to Dead, Piping and Equipment Loads

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 19 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

5. CONCLUSION

From the following results, it can be concluded that the Lighting Pole Structure including
connections are adequate to withstand all loads during service life by satisfying the requirements
set forth in Ref [1], [2], [3], [4], [5].

5.1 Unity Check of Stress Results


The following results present Unity Check of Stress for KO Drum Platform Structure.

EL. 5.735

EL. 5.324

Figure 5.1 KO Drum Platform Structure 3D Model

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 20 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

Figure 5.2 KO Drum Platform Member ID EL+5.324 to EL+5.735

Table 5.1 Summary of Maximum Stress UC


Design Actual Allowable Normalized Ratio*
Beam Clause L/C Results
Property Ratio Ratio (Actual/Allowable)
275 L75X75X6 0.68 1.33 0.51 AISC- H1-3 119 Pass
289 L75X75X6 0.31 1.33 0.23 AISC- H2-1 116 Pass
270 C150X75X6.5 0.28 1.33 0.21 AISC- H1-3 120 Pass
236 I200X100X7 0.23 1.33 0.18 AISC- H1-3 111 Pass
290 L75X75X6 0.23 1.33 0.17 AISC- H2-1 114 Pass
237 I200X100X7 0.22 1.33 0.17 AISC- H1-3 114 Pass
292 L75X75X6 0.21 1.33 0.15 AISC- H2-1 116 Pass
276 L75X75X6 0.20 1.33 0.15 AISC- H2-1 119 Pass
295 I200X100X7 0.19 1.33 0.15 AISC- H1-3 111 Pass
130 I200X100X7 0.18 1.33 0.14 AISC- H2-1 111 Pass
235 I200X100X7 0.15 1.33 0.12 AISC- H1-3 114 Pass
251 I200X100X7 0.15 1.33 0.11 AISC- H1-3 114 Pass
250 I200X100X7 0.15 1.33 0.11 AISC- H1-3 114 Pass
224 I200X100X7 0.14 1.33 0.11 AISC- H1-3 111 Pass
155 I200X100X7 0.14 1.33 0.11 AISC- H2-1 111 Pass
136 I200X100X7 0.13 1.33 0.10 AISC- H2-1 111 Pass
169 C200X80X7.5 0.13 1.33 0.10 AISC- H1-3 111 Pass

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 21 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

Design Actual Allowable Normalized Ratio*


Beam Clause L/C Results
Property Ratio Ratio (Actual/Allowable)
153 I200X100X7 0.13 1.33 0.10 AISC- H1-3 114 Pass
175 C200X80X7.5 0.12 1.33 0.09 AISC- H2-1 111 Pass
208 I200X100X7 0.12 1.33 0.09 AISC- H2-1 111 Pass
122 I200X100X7 0.12 1.33 0.09 AISC- H2-1 111 Pass
133 C200X80X7.5 0.12 1.33 0.09 AISC- H2-1 104 Pass
297 L75X75X6 0.12 1.33 0.09 AISC- H2-1 103 Pass
268 C200X80X7.5 0.11 1.33 0.08 AISC- H2-1 110 Pass
294 L75X75X6 0.11 1.33 0.08 AISC- H2-1 114 Pass
160 C200X80X7.5 0.10 1.33 0.08 AISC- H1-3 111 Pass
249 I200X100X7 0.10 1.33 0.07 AISC- H1-3 114 Pass
202 I200X100X7 0.10 1.33 0.07 AISC- H2-1 111 Pass
223 I200X100X7 0.09 1.33 0.07 AISC- H1-3 111 Pass
266 C200X80X7.5 0.09 1.33 0.07 AISC- H2-1 104 Pass
167 C200X80X7.5 0.09 1.33 0.07 AISC- H2-1 126 Pass
161 C200X80X7.5 0.08 1.33 0.06 AISC- H1-3 126 Pass
152 I200X100X7 0.08 1.33 0.06 AISC- H2-1 114 Pass
257 I200X100X7 0.08 1.33 0.06 AISC- H1-3 110 Pass
140 C200X80X7.5 0.07 1.33 0.05 AISC- H1-3 111 Pass
264 C200X80X7.5 0.07 1.33 0.05 AISC- H2-1 114 Pass
129 C200X80X7.5 0.07 1.33 0.05 AISC- H2-1 111 Pass
131 C200X80X7.5 0.07 1.33 0.05 AISC- H2-1 111 Pass
139 C200X80X7.5 0.06 1.33 0.05 AISC- H1-3 111 Pass
252 C200X80X7.5 0.06 1.33 0.05 AISC- H2-1 120 Pass
138 I200X100X7 0.06 1.33 0.05 AISC- H2-1 124 Pass
135 C200X80X7.5 0.06 1.33 0.05 AISC- H1-3 105 Pass
173 C200X80X7.5 0.06 1.33 0.04 AISC- H1-3 111 Pass
228 I200X100X7 0.06 1.33 0.044 AISC- H1-3 110 Pass
172 C200X80X7.5 0.06 1.33 0.043 AISC- H1-3 111 Pass
205 I200X100X7 0.06 1.33 0.043 AISC- H1-3 111 Pass
254 C200X80X7.5 0.06 1.33 0.043 AISC- H2-1 120 Pass
298 C200X80X7.5 0.056 1.33 0.042 AISC- H1-3 126 Pass
300 C200X80X7.5 0.053 1.33 0.039 AISC- H2-1 126 Pass
126 C200X80X7.5 0.045 1.33 0.033 AISC- H1-3 104 Pass
163 C200X80X7.5 0.045 1.33 0.034 AISC- H1-3 126 Pass
154 C200X80X7.5 0.044 1.33 0.033 AISC- H1-3 120 Pass
177 C200X80X7.5 0.044 1.33 0.033 AISC- H1-3 120 Pass
164 C200X80X7.5 0.043 1.33 0.032 AISC- H1-3 126 Pass
226 I200X100X7 0.042 1.33 0.032 AISC- H1-3 110 Pass
273 C200X80X7.5 0.041 1.33 0.030 AISC- H1-3 111 Pass
UPD-ME-W7-CI-CL-4103_Rev. 0 Page 22 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

Design Actual Allowable Normalized Ratio*


Beam Clause L/C Results
Property Ratio Ratio (Actual/Allowable)
299 L75X75X6 0.041 1.33 0.031 AISC- H2-1 116 Pass
256 C200X80X7.5 0.040 1.33 0.030 AISC- H1-3 126 Pass
141 C200X80X7.5 0.039 1.33 0.029 AISC- H1-3 111 Pass
174 I200X100X7 0.035 1.33 0.026 AISC- H2-1 111 Pass
124 C200X80X7.5 0.034 1.33 0.025 AISC- H1-3 126 Pass
166 C200X80X7.5 0.031 1.33 0.023 AISC- H1-3 124 Pass
272 C150X75X6.5 0.025 1.33 0.019 AISC- H2-1 120 Pass
181 C200X80X7.5 0.023 1.33 0.017 AISC- H2-1 111 Pass
182 C200X80X7.5 0.020 1.33 0.015 AISC- H1-3 111 Pass
267 C200X80X7.5 0.015 1.33 0.011 AISC- H2-1 116 Pass
Note*: Normalized Ratio is the Ratio with Allowable Increase in Actual Ratio with a factor of 1.33

5.2 Unity Check of Deflection Results


The subsequent Table shows the summary of deflection unity check in the calculation for
Evacuation Walkway Structure. The limits of deflection are set forth as per Ref.[1]. The limits are
1/200 for vertical members, 1/360 for beams or horizontal members and 1/240 for cantilever
members.

Figure 5.3 KO Drum Platform Node ID EL+5.324 to EL+5.735

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 23 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

Table 5.2 Summary of Maximum Deflection UC

Allowable Actual
Node Node Deflection Deflection Actual Ratio L/C Results
Property (mm) (mm)
A B

64 127 I200X100X7 0.50 0.00 0.009 111 Pass


106 208 C200X80X7.5 1.35 0.07 0.052 127 Pass
108 110 C200X80X7.5 1.35 0.07 0.052 127 Pass
110 112 C200X80X7.5 1.35 0.07 0.052 127 Pass
113 129 I200X100X7 0.51 0.01 0.011 111 Pass
112 203 C200X80X7.5 1.35 0.07 0.052 131 Pass
114 116 C200X80X7.5 1.69 0.07 0.044 103 Pass
116 118 C200X80X7.5 1.61 0.07 0.044 107 Pass
119 135 I200X100X7 0.51 0.00 0.007 107 Pass
123 138 I200X100X7 0.52 0.00 0.004 107 Pass
118 120 C200X80X7.5 1.77 0.08 0.044 107 Pass
120 122 C200X80X7.5 1.77 0.01 0.007 114 Pass
122 124 C200X80X7.5 1.77 0.01 0.003 111 Pass
127 194 I200X100X7 0.62 0.01 0.009 111 Pass
128 106 I200X100X7 2.93 0.04 0.013 114 Pass
108 134 C200X80X7.5 2.12 0.008 0.004 120 Pass
129 183 I200X100X7 0.62 0.01 0.011 111 Pass
131 129 C200X80X7.5 0.58 0.01 0.009 111 Pass
130 131 C200X80X7.5 0.49 0.00 0.009 111 Pass
133 110 C200X80X7.5 3.08 0.01 0.004 120 Pass
128 134 C200X80X7.5 0.80 0.00 0.002 120 Pass
134 133 C200X80X7.5 0.78 0.00 0.003 124 Pass
127 130 C200X80X7.5 1.08 0.01 0.009 111 Pass
129 136 C200X80X7.5 0.71 0.01 0.008 114 Pass
137 135 C200X80X7.5 0.74 0.01 0.008 110 Pass
136 137 C200X80X7.5 0.59 0.00 0.008 114 Pass
138 158 I200X100X7 0.62 0.00 0.004 104 Pass
135 139 C200X80X7.5 0.70 0.00 0.005 126 Pass
139 138 C200X80X7.5 0.70 0.00 0.005 126 Pass
138 143 C200X80X7.5 2.82 0.011 0.004 111 Pass
124 143 C200X80X7.5 2.40 0.00 0.002 111 Pass
135 162 I200X100X7 3.21 0.03 0.009 107 Pass
158 124 I200X100X7 0.62 0.001 0.001 105 Pass
162 195 I200X100X7 6.22 0.02 0.004 111 Pass
169 170 I200X100X7 3.29 0.01 0.002 117 Pass
170 162 I200X100X7 0.47 0.006 0.013 118 Pass

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 24 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

Allowable Actual
Node Node
Property Deflection Deflection Actual Ratio L/C Results
A B
(mm) (mm)
173 174 I200X100X7 2.34 0.007 0.003 104 Pass
174 158 I200X100X7 2.34 0.02 0.009 110 Pass
181 182 I200X100X7 0.93 0.01 0.010 114 Pass
183 228 I200X100X7 2.34 0.01 0.004 114 Pass
182 183 I200X100X7 0.92 0.01 0.009 105 Pass
192 193 I200X100X7 3.30 0.01 0.004 104 Pass
194 128 I200X100X7 0.90 0.01 0.006 114 Pass
193 194 I200X100X7 0.90 0.00 0.003 114 Pass
139 122 C200X80X7.5 0.26 0.01 0.052 111 Pass
136 116 C200X80X7.5 2.34 0.20 0.085 111 Pass
130 133 C200X80X7.5 2.94 0.00 0.001 111 Pass
195 120 I200X100X7 2.66 0.14 0.052 111 Pass
106 200 C200X80X7.5 3.07 0.76 0.249 114 Pass
110 202 C200X80X7.5 0.93 0.01 0.007 114 Pass
202 200 C200X80X7.5 1.08 0.05 0.044 103 Pass
203 114 C200X80X7.5 2.59 0.05 0.018 127 Pass
203 205 C150X75X6.5 5.63 0.07 0.012 120 Pass
207 205 C150X75X6.5 1.01 0.01 0.006 107 Pass
208 108 C200X80X7.5 0.80 0.02 0.020 127 Pass
208 210 L75X75X6 3.04 0.02 0.006 106 Pass
211 210 L75X75X6 0.83 0.01 0.010 120 Pass
195 221 L75X75X6 2.59 0.01 0.002 123 Pass
221 223 L75X75X6 1.83 0.01 0.008 120 Pass
114 224 L75X75X6 0.63 0.00 0.000 118 Pass
227 224 L75X75X6 1.22 0.00 0.000 130 Pass
228 114 I200X100X7 2.88 0.00 0.000 114 Pass
228 230 L75X75X6 1.25 0.00 0.000 103 Pass
131 112 C200X80X7.5 3.07 0.00 0.000 111 Pass
230 232 L75X75X6 0.83 0.00 0.000 126 Pass
137 118 C200X80X7.5 3.07 0.00 0.000 111 Pass

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 25 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

5.3 Connection Design Results

5.3.1 Beam to Vessel Connection – Bolted Pinned

The connection capacity summary for beam to vessel bolted connection design is presented below.
For detail calculation, please see Attachment D.

Figure 5.4 Beam to Vessel Bolted Connection

Table 5.3 Beam Bolted Connection Capacity


Capacity Allowable Capacity
Tension
Ts1 = 172.79 kN Ts all = 172.79 kN
Ts2 = 192.00 kN
Ts3 = 439.81 kN
Ts4 = 292.00 kN
Ts5 = 452.00 kN

Shear
Vs1 = 62.83 kN Vs all = 62.83 kN
Vs2 = 192.00 kN
Vs3 = 182.03 kN
Vs4 = 175.20 kN
Vs5 = 166.11 kN
Vs6 = 192.00 kN

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 26 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

Maximum Support Reaction:

Node : 235
Load Combination 114 1.15D+1.15E(O)+1.15P(O)+L

Tension force Ts = 0.00 kN < Tsall = 172.79 OK


Shear force Vs = 17.46 kN < Vsall = 62.83 OK

Combination Tension and Shear


Ts + Vs < 1
Tsall Vsall

0.00 + 17.46 < 1 0.28 < 1 OK


172.79 62.83

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 27 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

5.3.2 Beam Bolted Connection


The connection capacity summary for beam bolted connection design is presented below. For detail
calculation, please see Attachment D.

Figure 5.5 Beam Bolted Connection

Table 5.4 Beam Bolted Connection Capacity


Capacity Allowable Capacity
Tension
Ts1 = 172.79 kN Ts all = 172.00 kN
Ts2 = 153.60 kN
Ts3 = 293.21 kN
Ts4 = 172.00 kN
Ts5 = 281.60 kN

Shear
Vs1 = 62.83 kN Vs all = 62.83 kN
Vs2 = 153.60 kN
Vs3 = 141.72 kN
Vs4 = 103.20 kN
Vs5 = 103.49 kN
Vs6 = 153.60 kN

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 28 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

Maximum Support Reaction:

Node : 130
Load Combination 114 1.15D+1.15E(O)+1.15P(O)+L

Tension force Ts = 30.60 kN < Tsall = 172.00 OK


Shear force Vs = 17.47 kN < Vsall = 62.83 OK

Combination Tension and Shear


Ts + Vs < 1
Tsall Vsall

30.60 + 17.47 < 1 0.46 < 1 OK


172.00 62.83

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 29 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

5.3.3 Support Reactions


The subsequent Table shows the summary of support reactions for each basic load and support
reactions for Unfactored Load Combinations for foundation design. Units are in kN and kNm.

Table 5.5 Basic Load Support Reaction Summary


Joint Load
FX FY FZ MX MY MZ
ID ID
64 10 -1.04 0.32 -1.38 0.00 0.00 0.00
11 0.91 0.79 -2.09 0.00 0.00 0.00
1 1.78 -0.87 4.97 0.00 0.00 0.00
2 0.00 0.00 0.00 0.00 0.00 0.00
3 0.00 0.00 0.00 0.00 0.00 0.00
4 0.00 0.00 0.00 0.00 0.00 0.00
5 2.05 -1.54 6.05 0.00 0.00 0.00
6 2.37 -1.74 6.84 0.00 0.00 0.00
7 2.48 -1.92 7.48 0.00 0.00 0.00
8 -0.99 0.01 -1.60 0.00 0.00 0.00
9 0.99 0.48 -0.98 0.00 0.00 0.00
14 1.71 -0.87 4.50 0.00 0.00 0.00
15 1.03 -0.50 2.89 0.00 0.00 0.00
113 10 -6.52 0.68 -0.36 0.00 0.00 0.00
11 0.17 0.11 -3.19 0.00 0.00 0.00
1 8.63 0.44 1.18 0.00 0.00 0.00
2 0.00 0.00 0.00 0.00 0.00 0.00
3 0.00 0.00 0.00 0.00 0.00 0.00
4 0.00 0.00 0.00 0.00 0.00 0.00
5 4.76 0.04 0.61 0.00 0.00 0.00
6 6.36 -0.02 0.82 0.00 0.00 0.00
7 6.35 0.01 0.97 0.00 0.00 0.00
8 -2.07 -0.06 0.26 0.00 0.00 0.00
9 -2.54 0.47 -2.85 0.00 0.00 0.00
14 12.66 1.36 1.70 0.00 0.00 0.00
15 4.71 0.42 0.65 0.00 0.00 0.00
119 10 -0.95 -0.08 1.77 0.00 0.00 0.00
11 0.15 -0.10 -4.53 0.00 0.00 0.00
1 3.06 0.32 -3.79 0.00 0.00 0.00
2 0.00 0.00 0.00 0.00 0.00 0.00
3 0.00 0.00 0.00 0.00 0.00 0.00
4 0.00 0.00 0.00 0.00 0.00 0.00
5 0.15 0.21 -0.19 0.00 0.00 0.00
6 0.23 0.28 -0.33 0.00 0.00 0.00
7 0.21 0.29 -0.07 0.00 0.00 0.00
UPD-ME-W7-CI-CL-4103_Rev. 0 Page 30 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

Joint Load
FX FY FZ MX MY MZ
ID ID
8 -0.72 0.02 1.56 0.00 0.00 0.00
9 -0.28 -0.08 -3.25 0.00 0.00 0.00
14 5.78 0.98 -7.21 0.00 0.00 0.00
15 1.31 0.36 -1.61 0.00 0.00 0.00
123 10 0.22 -0.05 -0.56 0.00 0.00 0.00
11 -1.51 -0.02 1.44 0.00 0.00 0.00
1 0.00 -0.40 -3.06 0.00 0.00 0.00
2 0.00 0.00 0.00 0.00 0.00 0.00
3 0.00 0.00 0.00 0.00 0.00 0.00
4 0.00 0.00 0.00 0.00 0.00 0.00
5 0.06 0.00 0.51 0.00 0.00 0.00
6 0.07 0.00 0.68 0.00 0.00 0.00
7 0.15 0.01 0.58 0.00 0.00 0.00
8 0.28 -0.01 -0.14 0.00 0.00 0.00
9 -1.34 -0.04 0.89 0.00 0.00 0.00
14 0.01 -0.63 -4.79 0.00 0.00 0.00
15 0.00 -0.04 -1.45 0.00 0.00 0.00
169 10 -0.04 -0.01 -0.01 0.00 0.00 0.00
11 -0.59 0.52 0.72 0.00 0.00 0.00
1 -3.09 2.94 3.94 0.00 0.00 0.00
2 0.00 0.00 0.00 0.00 0.00 0.00
3 0.00 0.00 0.00 0.00 0.00 0.00
4 0.00 0.00 0.00 0.00 0.00 0.00
5 -0.28 0.24 0.01 0.00 0.00 0.00
6 -0.40 0.34 0.07 0.00 0.00 0.00
7 -0.34 0.29 0.00 0.00 0.00 0.00
8 -0.08 0.00 0.00 0.00 0.00 0.00
9 -0.14 0.09 0.04 0.00 0.00 0.00
14 -5.84 5.57 7.47 0.00 0.00 0.00
15 -1.32 1.35 1.68 0.00 0.00 0.00
173 10 0.01 0.23 0.41 0.00 0.00 0.00
11 -0.01 -0.11 -0.15 0.00 0.00 0.00
1 0.11 1.83 3.06 0.00 0.00 0.00
2 0.00 0.00 0.00 0.00 0.00 0.00
3 0.00 0.00 0.00 0.00 0.00 0.00
4 0.00 0.00 0.00 0.00 0.00 0.00
5 -0.01 -0.23 -0.42 0.00 0.00 0.00
6 -0.02 -0.32 -0.56 0.00 0.00 0.00
7 -0.02 -0.32 -0.56 0.00 0.00 0.00
8 -0.08 -0.02 -0.04 0.00 0.00 0.00

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 31 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

Joint Load
FX FY FZ MX MY MZ
ID ID
9 0.01 0.10 0.15 0.00 0.00 0.00
14 0.16 2.74 4.78 0.00 0.00 0.00
15 0.05 0.96 1.46 0.00 0.00 0.00
181 10 2.90 -1.39 0.41 0.00 0.00 0.00
11 0.12 -0.05 0.00 0.00 0.00 0.00
1 -8.82 5.09 -1.24 0.00 0.00 0.00
2 0.00 0.00 0.00 0.00 0.00 0.00
3 0.00 0.00 0.00 0.00 0.00 0.00
4 0.00 0.00 0.00 0.00 0.00 0.00
5 -4.80 2.69 -0.65 0.00 0.00 0.00
6 -6.32 3.55 -0.85 0.00 0.00 0.00
7 -6.45 3.62 -0.87 0.00 0.00 0.00
8 -0.48 0.25 -0.06 0.00 0.00 0.00
9 1.62 -0.73 -0.09 0.00 0.00 0.00
14 -12.95 7.53 -1.82 0.00 0.00 0.00
15 -4.81 2.85 -0.67 0.00 0.00 0.00
192 10 -0.09 0.31 -0.29 0.00 0.00 0.00
11 0.76 -1.13 2.30 0.00 0.00 0.00
1 -1.67 3.06 -5.08 0.00 0.00 0.00
2 0.00 0.00 0.00 0.00 0.00 0.00
3 0.00 0.00 0.00 0.00 0.00 0.00
4 0.00 0.00 0.00 0.00 0.00 0.00
5 -2.04 3.47 -6.25 0.00 0.00 0.00
6 -2.24 3.79 -6.85 0.00 0.00 0.00
7 -2.50 4.24 -7.65 0.00 0.00 0.00
8 0.03 -0.18 0.28 0.00 0.00 0.00
9 0.24 -0.28 0.69 0.00 0.00 0.00
14 -1.53 2.76 -4.64 0.00 0.00 0.00
15 -0.97 1.80 -2.94 0.00 0.00 0.00

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 32 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

Table 5.6 Basic Load ID Definition

Load ID Definition

10 Seismic Load X Direction

11 Seismic Load Z Direction

1 Dead Load (Incl. Selfweight)

2 Equipment Load (Empty)

3 Equipment Load (Operation)

4 Equipment Load (Test)

5 Piping Load (Empty)

6 Piping Load (Operation)

7 Piping Load (Test)

8 Wind Load Transverse

9 Wind Load Longitudinal

14 Live Load

15 Selfweight

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 33 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

Table 5.7 Unfactored Load Combination Support Reaction Summary


Joint
Load ID FX FY FZ MX MY MZ
ID
64 101 1.15D+1.15E(E)+1.15P(E)+L 6.12 -3.63 17.18 0.00 0.00 0.00
102 1.15D+1.15E(E)+1.15P(E)+WX 3.15 -2.63 10.33 0.00 0.00 0.00
103 1.15D+1.15E(E)+1.15P(E)+WZ 5.40 -2.29 11.70 0.00 0.00 0.00
104 1.15D+1.15E(E)+1.15P(E)+WX+L 5.13 -3.62 15.58 0.00 0.00 0.00
105 1.15D+1.15E(E)+1.15P(E)+WZ+L 7.10 -3.16 16.20 0.00 0.00 0.00
106 1.15D+1.15E(E)+1.15P(E)+EQ(E)X 3.37 -2.44 11.30 0.00 0.00 0.00
107 1.15D+1.15E(E)+1.15P(E)+EQ(E)Z 5.32 -1.98 10.59 0.00 0.00 0.00
108 1.15D+1.15E(E)+1.15P(E)+EQ(O)X 3.37 -2.44 11.30 0.00 0.00 0.00
109 1.15D+1.15E(E)+1.15(E)+EQ(O)Z 5.32 -1.98 10.59 0.00 0.00 0.00
110 1.15D+1.15E(E)+1.15P(E)+EQ(E)X+L 5.08 -3.31 15.80 0.00 0.00 0.00
111 1.15D+1.15E(E)+1.15P(E)+EQ(E)Z+L 7.03 -2.85 15.09 0.00 0.00 0.00
112 1.15D+1.15E(E)+1.15P(E)+EQ(O)X+L 5.08 -3.31 15.80 0.00 0.00 0.00
113 1.15D+1.15E(E)+1.15P(E)+EQ(O)Z+L 7.03 -2.85 15.09 0.00 0.00 0.00
114 1.15D+1.15E(O)+1.15P(O)+L 6.48 -3.87 18.09 0.00 0.00 0.00
115 1.15D+1.15E(O)+1.15P(O)+WX 3.78 -2.99 11.99 0.00 0.00 0.00
116 1.15D+1.15E(O)+1.15P(O)+WZ 5.76 -2.52 12.61 0.00 0.00 0.00
117 1.15D+1.15E(O)+1.15P(O)+WX+0.5L 4.64 -3.43 14.24 0.00 0.00 0.00
118 1.15D+1.15E(O)+1.15P(O)+WZ+0.5L 6.61 -2.96 14.86 0.00 0.00 0.00
119 1.15D+1.15E(O)+1.15P(O)+EQ(E)X 3.74 -2.68 12.21 0.00 0.00 0.00
120 1.15D+1.15E(O)+1.15P(O)+EQ(E)Z 5.69 -2.22 11.49 0.00 0.00 0.00
121 1.15D+1.15E(O)+1.15P(O)+EQ(O)X 3.74 -2.68 12.21 0.00 0.00 0.00
122 1.15D+1.15E(O)+1.15P(O)+EQ(O)Z 5.69 -2.22 11.49 0.00 0.00 0.00
123 1.15D+1.15E(O)+1.15P(O)+EQ(E)X+0.5L 4.59 -3.12 14.46 0.00 0.00 0.00
124 1.15D+1.15E(O)+1.15P(O)+1.15EQ(E)Z+0.5L 6.18 -2.39 12.72 0.00 0.00 0.00
125 1.15D+1.15E(O)+1.15P(O)+EQ(O)X+0.5L 4.59 -3.12 14.46 0.00 0.00 0.00
126 1.15D+1.15E(O)+1.15P(O)+EQ(O)Z+0.5L 6.54 -2.65 13.74 0.00 0.00 0.00
127 1.15D+1.15E(O)+1.15P(O) 4.77 -3.00 13.59 0.00 0.00 0.00
128 1.15D+1.15E(T)+1.15P(T)+0.5L 5.75 -3.64 16.57 0.00 0.00 0.00
129 1.15D+1.15E(T)+1.15P(T)+0.25WX+0.5L 5.50 -3.63 16.17 0.00 0.00 0.00
130 1.15D+1.15E(T)+1.15P(T)+0.25WZ+0.5L 6.00 -3.52 16.32 0.00 0.00 0.00
131 1.15D+1.15E(E)+1.15P(E) 4.41 -2.77 12.68 0.00 0.00 0.00
113 101 1.15D+1.15E(E)+1.15P(E)+L 28.06 1.91 3.77 0.00 0.00 0.00
102 1.15D+1.15E(E)+1.15P(E)+WX 12.04 0.43 2.14 0.00 0.00 0.00
103 1.15D+1.15E(E)+1.15P(E)+WZ 12.87 1.02 -0.79 0.00 0.00 0.00
104 1.15D+1.15E(E)+1.15P(E)+WX+L 25.99 1.85 4.02 0.00 0.00 0.00
105 1.15D+1.15E(E)+1.15P(E)+WZ+L 25.53 2.38 0.91 0.00 0.00 0.00
106 1.15D+1.15E(E)+1.15P(E)+EQ(E)X 8.88 1.23 1.70 0.00 0.00 0.00
107 1.15D+1.15E(E)+1.15P(E)+EQ(E)Z 15.57 0.66 -1.12 0.00 0.00 0.00
108 1.15D+1.15E(E)+1.15P(E)+EQ(O)X 8.88 1.23 1.70 0.00 0.00 0.00
109 1.15D+1.15E(E)+1.15(E)+EQ(O)Z 15.57 0.66 -1.12 0.00 0.00 0.00
110 1.15D+1.15E(E)+1.15P(E)+EQ(E)X+L 21.55 2.59 3.40 0.00 0.00 0.00
111 1.15D+1.15E(E)+1.15P(E)+EQ(E)Z+L 28.23 2.02 0.58 0.00 0.00 0.00

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 34 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

Joint
Load ID FX FY FZ MX MY MZ
ID
112 1.15D+1.15E(E)+1.15P(E)+EQ(O)X+L 21.55 2.59 3.40 0.00 0.00 0.00
113 1.15D+1.15E(E)+1.15P(E)+EQ(O)Z+L 28.23 2.02 0.58 0.00 0.00 0.00
114 1.15D+1.15E(O)+1.15P(O)+L 29.89 1.85 4.00 0.00 0.00 0.00
115 1.15D+1.15E(O)+1.15P(O)+WX 15.16 0.43 2.56 0.00 0.00 0.00
116 1.15D+1.15E(O)+1.15P(O)+WZ 14.70 0.96 -0.55 0.00 0.00 0.00
117 1.15D+1.15E(O)+1.15P(O)+WX+0.5L 21.49 1.11 3.41 0.00 0.00 0.00
118 1.15D+1.15E(O)+1.15P(O)+WZ+0.5L 21.03 1.64 0.30 0.00 0.00 0.00
119 1.15D+1.15E(O)+1.15P(O)+EQ(E)X 10.72 1.17 1.94 0.00 0.00 0.00
120 1.15D+1.15E(O)+1.15P(O)+EQ(E)Z 17.40 0.60 -0.89 0.00 0.00 0.00
121 1.15D+1.15E(O)+1.15P(O)+EQ(O)X 10.72 1.17 1.94 0.00 0.00 0.00
122 1.15D+1.15E(O)+1.15P(O)+EQ(O)Z 17.40 0.60 -0.89 0.00 0.00 0.00
123 1.15D+1.15E(O)+1.15P(O)+EQ(E)X+0.5L 17.05 1.85 2.79 0.00 0.00 0.00
124 1.15D+1.15E(O)+1.15P(O)+1.15EQ(E)Z+0.5L 22.78 1.28 -0.16 0.00 0.00 0.00
125 1.15D+1.15E(O)+1.15P(O)+EQ(O)X+0.5L 17.05 1.85 2.79 0.00 0.00 0.00
126 1.15D+1.15E(O)+1.15P(O)+EQ(O)Z+0.5L 23.73 1.28 -0.04 0.00 0.00 0.00
127 1.15D+1.15E(O)+1.15P(O) 17.23 0.49 2.30 0.00 0.00 0.00
128 1.15D+1.15E(T)+1.15P(T)+0.5L 23.56 1.20 3.32 0.00 0.00 0.00
129 1.15D+1.15E(T)+1.15P(T)+0.25WX+0.5L 23.04 1.19 3.39 0.00 0.00 0.00
130 1.15D+1.15E(T)+1.15P(T)+0.25WZ+0.5L 22.93 1.32 2.61 0.00 0.00 0.00
131 1.15D+1.15E(E)+1.15P(E) 15.40 0.55 2.06 0.00 0.00 0.00
119 101 1.15D+1.15E(E)+1.15P(E)+L 9.48 1.58 -11.79 0.00 0.00 0.00
102 1.15D+1.15E(E)+1.15P(E)+WX 2.51 0.58 -2.45 0.00 0.00 0.00
103 1.15D+1.15E(E)+1.15P(E)+WZ 3.41 0.53 -7.83 0.00 0.00 0.00
104 1.15D+1.15E(E)+1.15P(E)+WX+L 8.75 1.60 -10.23 0.00 0.00 0.00
105 1.15D+1.15E(E)+1.15P(E)+WZ+L 9.20 1.50 -15.04 0.00 0.00 0.00
106 1.15D+1.15E(E)+1.15P(E)+EQ(E)X 2.74 0.53 -2.81 0.00 0.00 0.00
107 1.15D+1.15E(E)+1.15P(E)+EQ(E)Z 3.84 0.51 -9.11 0.00 0.00 0.00
108 1.15D+1.15E(E)+1.15P(E)+EQ(O)X 2.74 0.53 -2.81 0.00 0.00 0.00
109 1.15D+1.15E(E)+1.15(E)+EQ(O)Z 3.84 0.51 -9.11 0.00 0.00 0.00
110 1.15D+1.15E(E)+1.15P(E)+EQ(E)X+L 8.52 1.50 -10.02 0.00 0.00 0.00
111 1.15D+1.15E(E)+1.15P(E)+EQ(E)Z+L 9.63 1.48 -16.32 0.00 0.00 0.00
112 1.15D+1.15E(E)+1.15P(E)+EQ(O)X+L 8.52 1.50 -10.02 0.00 0.00 0.00
113 1.15D+1.15E(E)+1.15P(E)+EQ(O)Z+L 9.63 1.48 -16.32 0.00 0.00 0.00
114 1.15D+1.15E(O)+1.15P(O)+L 9.57 1.66 -11.94 0.00 0.00 0.00
115 1.15D+1.15E(O)+1.15P(O)+WX 3.06 0.70 -3.17 0.00 0.00 0.00
116 1.15D+1.15E(O)+1.15P(O)+WZ 3.50 0.61 -7.98 0.00 0.00 0.00
117 1.15D+1.15E(O)+1.15P(O)+WX+0.5L 5.95 1.19 -6.77 0.00 0.00 0.00
118 1.15D+1.15E(O)+1.15P(O)+WZ+0.5L 6.40 1.09 -11.59 0.00 0.00 0.00
119 1.15D+1.15E(O)+1.15P(O)+EQ(E)X 2.83 0.60 -2.96 0.00 0.00 0.00
120 1.15D+1.15E(O)+1.15P(O)+EQ(E)Z 3.93 0.58 -9.26 0.00 0.00 0.00
121 1.15D+1.15E(O)+1.15P(O)+EQ(O)X 2.83 0.60 -2.96 0.00 0.00 0.00
122 1.15D+1.15E(O)+1.15P(O)+EQ(O)Z 3.93 0.58 -9.26 0.00 0.00 0.00
123 1.15D+1.15E(O)+1.15P(O)+EQ(E)X+0.5L 5.72 1.09 -6.57 0.00 0.00 0.00

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 35 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

Joint
Load ID FX FY FZ MX MY MZ
ID
124 1.15D+1.15E(O)+1.15P(O)+1.15EQ(E)Z+0.5L 6.79 1.03 -12.82 0.00 0.00 0.00
125 1.15D+1.15E(O)+1.15P(O)+EQ(O)X+0.5L 5.72 1.09 -6.57 0.00 0.00 0.00
126 1.15D+1.15E(O)+1.15P(O)+EQ(O)Z+0.5L 6.83 1.07 -12.86 0.00 0.00 0.00
127 1.15D+1.15E(O)+1.15P(O) 3.78 0.69 -4.73 0.00 0.00 0.00
128 1.15D+1.15E(T)+1.15P(T)+0.5L 6.65 1.18 -8.04 0.00 0.00 0.00
129 1.15D+1.15E(T)+1.15P(T)+0.25WX+0.5L 6.47 1.18 -7.65 0.00 0.00 0.00
130 1.15D+1.15E(T)+1.15P(T)+0.25WZ+0.5L 6.58 1.16 -8.86 0.00 0.00 0.00
131 1.15D+1.15E(E)+1.15P(E) 3.69 0.61 -4.58 0.00 0.00 0.00
123 101 1.15D+1.15E(E)+1.15P(E)+L 0.08 -1.09 -7.72 0.00 0.00 0.00
102 1.15D+1.15E(E)+1.15P(E)+WX 0.35 -0.40 -2.62 0.00 0.00 0.00
103 1.15D+1.15E(E)+1.15P(E)+WZ -1.27 -0.49 -2.05 0.00 0.00 0.00
104 1.15D+1.15E(E)+1.15P(E)+WX+L 0.36 -1.10 -7.87 0.00 0.00 0.00
105 1.15D+1.15E(E)+1.15P(E)+WZ+L -1.26 -1.12 -6.84 0.00 0.00 0.00
106 1.15D+1.15E(E)+1.15P(E)+EQ(E)X 0.29 -0.50 -3.49 0.00 0.00 0.00
107 1.15D+1.15E(E)+1.15P(E)+EQ(E)Z -1.44 -0.47 -1.49 0.00 0.00 0.00
108 1.15D+1.15E(E)+1.15P(E)+EQ(O)X 0.29 -0.50 -3.49 0.00 0.00 0.00
109 1.15D+1.15E(E)+1.15(E)+EQ(O)Z -1.44 -0.47 -1.49 0.00 0.00 0.00
110 1.15D+1.15E(E)+1.15P(E)+EQ(E)X+L 0.30 -1.14 -8.28 0.00 0.00 0.00
111 1.15D+1.15E(E)+1.15P(E)+EQ(E)Z+L -1.44 -1.11 -6.28 0.00 0.00 0.00
112 1.15D+1.15E(E)+1.15P(E)+EQ(O)X+L 0.30 -1.14 -8.28 0.00 0.00 0.00
113 1.15D+1.15E(E)+1.15P(E)+EQ(O)Z+L -1.44 -1.11 -6.28 0.00 0.00 0.00
114 1.15D+1.15E(O)+1.15P(O)+L 0.09 -1.09 -7.52 0.00 0.00 0.00
115 1.15D+1.15E(O)+1.15P(O)+WX 0.36 -0.46 -2.87 0.00 0.00 0.00
116 1.15D+1.15E(O)+1.15P(O)+WZ -1.26 -0.49 -1.84 0.00 0.00 0.00
117 1.15D+1.15E(O)+1.15P(O)+WX+0.5L 0.36 -0.78 -5.27 0.00 0.00 0.00
118 1.15D+1.15E(O)+1.15P(O)+WZ+0.5L -1.26 -0.81 -4.24 0.00 0.00 0.00
119 1.15D+1.15E(O)+1.15P(O)+EQ(E)X 0.30 -0.50 -3.28 0.00 0.00 0.00
120 1.15D+1.15E(O)+1.15P(O)+EQ(E)Z -1.44 -0.47 -1.29 0.00 0.00 0.00
121 1.15D+1.15E(O)+1.15P(O)+EQ(O)X 0.30 -0.50 -3.28 0.00 0.00 0.00
122 1.15D+1.15E(O)+1.15P(O)+EQ(O)Z -1.44 -0.47 -1.29 0.00 0.00 0.00
123 1.15D+1.15E(O)+1.15P(O)+EQ(E)X+0.5L 0.30 -0.82 -5.68 0.00 0.00 0.00
124 1.15D+1.15E(O)+1.15P(O)+1.15EQ(E)Z+0.5L -1.44 -0.79 -3.79 0.00 0.00 0.00
125 1.15D+1.15E(O)+1.15P(O)+EQ(O)X+0.5L 0.30 -0.82 -5.68 0.00 0.00 0.00
126 1.15D+1.15E(O)+1.15P(O)+EQ(O)Z+0.5L -1.43 -0.79 -3.68 0.00 0.00 0.00
127 1.15D+1.15E(O)+1.15P(O) 0.08 -0.45 -2.73 0.00 0.00 0.00
128 1.15D+1.15E(T)+1.15P(T)+0.5L 0.17 -0.77 -5.25 0.00 0.00 0.00
129 1.15D+1.15E(T)+1.15P(T)+0.25WX+0.5L 0.24 -0.77 -5.28 0.00 0.00 0.00
130 1.15D+1.15E(T)+1.15P(T)+0.25WZ+0.5L -0.16 -0.77 -5.02 0.00 0.00 0.00
131 1.15D+1.15E(E)+1.15P(E) 0.07 -0.45 -2.93 0.00 0.00 0.00
169 101 1.15D+1.15E(E)+1.15P(E)+L -9.71 9.23 12.02 0.00 0.00 0.00
102 1.15D+1.15E(E)+1.15P(E)+WX -3.49 3.22 3.95 0.00 0.00 0.00
103 1.15D+1.15E(E)+1.15P(E)+WZ -4.02 3.75 4.58 0.00 0.00 0.00
104 1.15D+1.15E(E)+1.15P(E)+WX+L -9.80 9.23 12.02 0.00 0.00 0.00

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 36 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

Joint
Load ID FX FY FZ MX MY MZ
ID
105 1.15D+1.15E(E)+1.15P(E)+WZ+L -9.86 9.32 12.06 0.00 0.00 0.00
106 1.15D+1.15E(E)+1.15P(E)+EQ(E)X -3.91 3.65 4.54 0.00 0.00 0.00
107 1.15D+1.15E(E)+1.15P(E)+EQ(E)Z -4.47 4.18 5.26 0.00 0.00 0.00
108 1.15D+1.15E(E)+1.15P(E)+EQ(O)X -3.91 3.65 4.54 0.00 0.00 0.00
109 1.15D+1.15E(E)+1.15(E)+EQ(O)Z -4.47 4.18 5.26 0.00 0.00 0.00
110 1.15D+1.15E(E)+1.15P(E)+EQ(E)X+L -9.75 9.22 12.01 0.00 0.00 0.00
111 1.15D+1.15E(E)+1.15P(E)+EQ(E)Z+L -10.31 9.75 12.73 0.00 0.00 0.00
112 1.15D+1.15E(E)+1.15P(E)+EQ(O)X+L -9.75 9.22 12.01 0.00 0.00 0.00
113 1.15D+1.15E(E)+1.15P(E)+EQ(O)Z+L -10.31 9.75 12.73 0.00 0.00 0.00
114 1.15D+1.15E(O)+1.15P(O)+L -9.85 9.35 12.08 0.00 0.00 0.00
115 1.15D+1.15E(O)+1.15P(O)+WX -4.09 3.78 4.61 0.00 0.00 0.00
116 1.15D+1.15E(O)+1.15P(O)+WZ -4.15 3.87 4.65 0.00 0.00 0.00
117 1.15D+1.15E(O)+1.15P(O)+WX+0.5L -7.01 6.57 8.35 0.00 0.00 0.00
118 1.15D+1.15E(O)+1.15P(O)+WZ+0.5L -7.07 6.65 8.39 0.00 0.00 0.00
119 1.15D+1.15E(O)+1.15P(O)+EQ(E)X -4.05 3.77 4.60 0.00 0.00 0.00
120 1.15D+1.15E(O)+1.15P(O)+EQ(E)Z -4.60 4.30 5.32 0.00 0.00 0.00
121 1.15D+1.15E(O)+1.15P(O)+EQ(O)X -4.05 3.77 4.60 0.00 0.00 0.00
122 1.15D+1.15E(O)+1.15P(O)+EQ(O)Z -4.60 4.30 5.32 0.00 0.00 0.00
123 1.15D+1.15E(O)+1.15P(O)+EQ(E)X+0.5L -6.97 6.55 8.34 0.00 0.00 0.00
124 1.15D+1.15E(O)+1.15P(O)+1.15EQ(E)Z+0.5L -7.46 7.03 9.05 0.00 0.00 0.00
125 1.15D+1.15E(O)+1.15P(O)+EQ(O)X+0.5L -6.97 6.55 8.34 0.00 0.00 0.00
126 1.15D+1.15E(O)+1.15P(O)+EQ(O)Z+0.5L -7.52 7.08 9.06 0.00 0.00 0.00
127 1.15D+1.15E(O)+1.15P(O) -4.01 3.78 4.61 0.00 0.00 0.00
128 1.15D+1.15E(T)+1.15P(T)+0.5L -6.86 6.51 8.26 0.00 0.00 0.00
129 1.15D+1.15E(T)+1.15P(T)+0.25WX+0.5L -6.88 6.51 8.26 0.00 0.00 0.00
130 1.15D+1.15E(T)+1.15P(T)+0.25WZ+0.5L -6.90 6.53 8.27 0.00 0.00 0.00
131 1.15D+1.15E(E)+1.15P(E) -3.87 3.66 4.54 0.00 0.00 0.00
173 101 1.15D+1.15E(E)+1.15P(E)+L 0.27 4.58 7.82 0.00 0.00 0.00
102 1.15D+1.15E(E)+1.15P(E)+WX 0.01 1.54 2.54 0.00 0.00 0.00
103 1.15D+1.15E(E)+1.15P(E)+WZ 0.11 1.94 3.20 0.00 0.00 0.00
104 1.15D+1.15E(E)+1.15P(E)+WX+L 0.19 4.56 7.78 0.00 0.00 0.00
105 1.15D+1.15E(E)+1.15P(E)+WZ+L 0.27 4.68 7.98 0.00 0.00 0.00
106 1.15D+1.15E(E)+1.15P(E)+EQ(E)X 0.12 2.07 3.46 0.00 0.00 0.00
107 1.15D+1.15E(E)+1.15P(E)+EQ(E)Z 0.10 1.73 2.89 0.00 0.00 0.00
108 1.15D+1.15E(E)+1.15P(E)+EQ(O)X 0.12 2.07 3.46 0.00 0.00 0.00
109 1.15D+1.15E(E)+1.15(E)+EQ(O)Z 0.10 1.73 2.89 0.00 0.00 0.00
110 1.15D+1.15E(E)+1.15P(E)+EQ(E)X+L 0.28 4.81 8.24 0.00 0.00 0.00
111 1.15D+1.15E(E)+1.15P(E)+EQ(E)Z+L 0.26 4.48 7.67 0.00 0.00 0.00
112 1.15D+1.15E(E)+1.15P(E)+EQ(O)X+L 0.28 4.81 8.24 0.00 0.00 0.00
113 1.15D+1.15E(E)+1.15P(E)+EQ(O)Z+L 0.26 4.48 7.67 0.00 0.00 0.00
114 1.15D+1.15E(O)+1.15P(O)+L 0.26 4.49 7.65 0.00 0.00 0.00
115 1.15D+1.15E(O)+1.15P(O)+WX 0.02 1.72 2.83 0.00 0.00 0.00
116 1.15D+1.15E(O)+1.15P(O)+WZ 0.11 1.84 3.03 0.00 0.00 0.00

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 37 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

Joint
Load ID FX FY FZ MX MY MZ
ID
117 1.15D+1.15E(O)+1.15P(O)+WX+0.5L 0.10 3.09 5.22 0.00 0.00 0.00
118 1.15D+1.15E(O)+1.15P(O)+WZ+0.5L 0.19 3.21 5.42 0.00 0.00 0.00
119 1.15D+1.15E(O)+1.15P(O)+EQ(E)X 0.11 1.97 3.29 0.00 0.00 0.00
120 1.15D+1.15E(O)+1.15P(O)+EQ(E)Z 0.09 1.63 2.72 0.00 0.00 0.00
121 1.15D+1.15E(O)+1.15P(O)+EQ(O)X 0.11 1.97 3.29 0.00 0.00 0.00
122 1.15D+1.15E(O)+1.15P(O)+EQ(O)Z 0.09 1.63 2.72 0.00 0.00 0.00
123 1.15D+1.15E(O)+1.15P(O)+EQ(E)X+0.5L 0.19 3.34 5.68 0.00 0.00 0.00
124 1.15D+1.15E(O)+1.15P(O)+1.15EQ(E)Z+0.5L 0.18 3.05 5.19 0.00 0.00 0.00
125 1.15D+1.15E(O)+1.15P(O)+EQ(O)X+0.5L 0.19 3.34 5.68 0.00 0.00 0.00
126 1.15D+1.15E(O)+1.15P(O)+EQ(O)Z+0.5L 0.18 3.01 5.11 0.00 0.00 0.00
127 1.15D+1.15E(O)+1.15P(O) 0.10 1.74 2.88 0.00 0.00 0.00
128 1.15D+1.15E(T)+1.15P(T)+0.5L 0.18 3.12 5.27 0.00 0.00 0.00
129 1.15D+1.15E(T)+1.15P(T)+0.25WX+0.5L 0.16 3.11 5.26 0.00 0.00 0.00
130 1.15D+1.15E(T)+1.15P(T)+0.25WZ+0.5L 0.18 3.14 5.30 0.00 0.00 0.00
131 1.15D+1.15E(E)+1.15P(E) 0.11 1.84 3.05 0.00 0.00 0.00
181 101 1.15D+1.15E(E)+1.15P(E)+L -28.61 16.49 -3.99 0.00 0.00 0.00
102 1.15D+1.15E(E)+1.15P(E)+WX -14.82 8.44 -2.04 0.00 0.00 0.00
103 1.15D+1.15E(E)+1.15P(E)+WZ -14.04 8.22 -2.26 0.00 0.00 0.00
104 1.15D+1.15E(E)+1.15P(E)+WX+L -29.10 16.74 -4.05 0.00 0.00 0.00
105 1.15D+1.15E(E)+1.15P(E)+WZ+L -26.99 15.75 -4.08 0.00 0.00 0.00
106 1.15D+1.15E(E)+1.15P(E)+EQ(E)X -12.76 7.56 -1.76 0.00 0.00 0.00
107 1.15D+1.15E(E)+1.15P(E)+EQ(E)Z -15.54 8.90 -2.17 0.00 0.00 0.00
108 1.15D+1.15E(E)+1.15P(E)+EQ(O)X -12.76 7.56 -1.76 0.00 0.00 0.00
109 1.15D+1.15E(E)+1.15(E)+EQ(O)Z -15.54 8.90 -2.17 0.00 0.00 0.00
110 1.15D+1.15E(E)+1.15P(E)+EQ(E)X+L -25.71 15.10 -3.58 0.00 0.00 0.00
111 1.15D+1.15E(E)+1.15P(E)+EQ(E)Z+L -28.49 16.44 -3.99 0.00 0.00 0.00
112 1.15D+1.15E(E)+1.15P(E)+EQ(O)X+L -25.71 15.10 -3.58 0.00 0.00 0.00
113 1.15D+1.15E(E)+1.15P(E)+EQ(O)Z+L -28.49 16.44 -3.99 0.00 0.00 0.00
114 1.15D+1.15E(O)+1.15P(O)+L -30.37 17.47 -4.22 0.00 0.00 0.00
115 1.15D+1.15E(O)+1.15P(O)+WX -17.90 10.18 -2.46 0.00 0.00 0.00
116 1.15D+1.15E(O)+1.15P(O)+WZ -15.80 9.20 -2.49 0.00 0.00 0.00
117 1.15D+1.15E(O)+1.15P(O)+WX+0.5L -24.37 13.95 -3.37 0.00 0.00 0.00
118 1.15D+1.15E(O)+1.15P(O)+WZ+0.5L -22.27 12.97 -3.40 0.00 0.00 0.00
119 1.15D+1.15E(O)+1.15P(O)+EQ(E)X -14.51 8.54 -1.99 0.00 0.00 0.00
120 1.15D+1.15E(O)+1.15P(O)+EQ(E)Z -17.29 9.88 -2.40 0.00 0.00 0.00
121 1.15D+1.15E(O)+1.15P(O)+EQ(O)X -14.51 8.54 -1.99 0.00 0.00 0.00
122 1.15D+1.15E(O)+1.15P(O)+EQ(O)Z -17.29 9.88 -2.40 0.00 0.00 0.00
123 1.15D+1.15E(O)+1.15P(O)+EQ(E)X+0.5L -20.99 12.31 -2.90 0.00 0.00 0.00
124 1.15D+1.15E(O)+1.15P(O)+1.15EQ(E)Z+0.5L -22.82 13.12 -3.18 0.00 0.00 0.00
125 1.15D+1.15E(O)+1.15P(O)+EQ(O)X+0.5L -20.99 12.31 -2.90 0.00 0.00 0.00
126 1.15D+1.15E(O)+1.15P(O)+EQ(O)Z+0.5L -23.77 13.65 -3.31 0.00 0.00 0.00
127 1.15D+1.15E(O)+1.15P(O) -17.42 9.93 -2.40 0.00 0.00 0.00
128 1.15D+1.15E(T)+1.15P(T)+0.5L -24.03 13.79 -3.33 0.00 0.00 0.00

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 38 of 39
CALCULATION FOR KO DRUM
PLATFORM STRUCTURE

Joint
Load ID FX FY FZ MX MY MZ
ID
129 1.15D+1.15E(T)+1.15P(T)+0.25WX+0.5L -24.15 13.85 -3.35 0.00 0.00 0.00
130 1.15D+1.15E(T)+1.15P(T)+0.25WZ+0.5L -23.63 13.60 -3.35 0.00 0.00 0.00
131 1.15D+1.15E(E)+1.15P(E) -15.66 8.95 -2.17 0.00 0.00 0.00
192 101 1.15D+1.15E(E)+1.15P(E)+L -5.80 10.27 -17.66 0.00 0.00 0.00
102 1.15D+1.15E(E)+1.15P(E)+WX -3.99 6.87 -11.99 0.00 0.00 0.00
103 1.15D+1.15E(E)+1.15P(E)+WZ -4.02 7.23 -12.34 0.00 0.00 0.00
104 1.15D+1.15E(E)+1.15P(E)+WX+L -5.77 10.09 -17.38 0.00 0.00 0.00
105 1.15D+1.15E(E)+1.15P(E)+WZ+L -5.55 9.99 -16.97 0.00 0.00 0.00
106 1.15D+1.15E(E)+1.15P(E)+EQ(E)X -4.36 7.82 -13.32 0.00 0.00 0.00
107 1.15D+1.15E(E)+1.15P(E)+EQ(E)Z -3.51 6.38 -10.73 0.00 0.00 0.00
108 1.15D+1.15E(E)+1.15P(E)+EQ(O)X -4.36 7.82 -13.32 0.00 0.00 0.00
109 1.15D+1.15E(E)+1.15(E)+EQ(O)Z -3.51 6.38 -10.73 0.00 0.00 0.00
110 1.15D+1.15E(E)+1.15P(E)+EQ(E)X+L -5.89 10.58 -17.95 0.00 0.00 0.00
111 1.15D+1.15E(E)+1.15P(E)+EQ(E)Z+L -5.04 9.14 -15.37 0.00 0.00 0.00
112 1.15D+1.15E(E)+1.15P(E)+EQ(O)X+L -5.89 10.58 -17.95 0.00 0.00 0.00
113 1.15D+1.15E(E)+1.15P(E)+EQ(O)Z+L -5.04 9.14 -15.37 0.00 0.00 0.00
114 1.15D+1.15E(O)+1.15P(O)+L -6.02 10.64 -18.36 0.00 0.00 0.00
115 1.15D+1.15E(O)+1.15P(O)+WX -4.47 7.70 -13.44 0.00 0.00 0.00
116 1.15D+1.15E(O)+1.15P(O)+WZ -4.25 7.60 -13.03 0.00 0.00 0.00
117 1.15D+1.15E(O)+1.15P(O)+WX+0.5L -5.23 9.08 -15.76 0.00 0.00 0.00
118 1.15D+1.15E(O)+1.15P(O)+WZ+0.5L -5.02 8.98 -15.35 0.00 0.00 0.00
119 1.15D+1.15E(O)+1.15P(O)+EQ(E)X -4.59 8.19 -14.01 0.00 0.00 0.00
120 1.15D+1.15E(O)+1.15P(O)+EQ(E)Z -3.74 6.75 -11.42 0.00 0.00 0.00
121 1.15D+1.15E(O)+1.15P(O)+EQ(O)X -4.59 8.19 -14.01 0.00 0.00 0.00
122 1.15D+1.15E(O)+1.15P(O)+EQ(O)Z -3.74 6.75 -11.42 0.00 0.00 0.00
123 1.15D+1.15E(O)+1.15P(O)+EQ(E)X+0.5L -5.35 9.57 -16.33 0.00 0.00 0.00
124 1.15D+1.15E(O)+1.15P(O)+1.15EQ(E)Z+0.5L -4.17 7.56 -12.71 0.00 0.00 0.00
125 1.15D+1.15E(O)+1.15P(O)+EQ(O)X+0.5L -5.35 9.57 -16.33 0.00 0.00 0.00
126 1.15D+1.15E(O)+1.15P(O)+EQ(O)Z+0.5L -4.50 8.13 -13.74 0.00 0.00 0.00
127 1.15D+1.15E(O)+1.15P(O) -4.50 7.88 -13.72 0.00 0.00 0.00
128 1.15D+1.15E(T)+1.15P(T)+0.5L -5.56 9.78 -16.96 0.00 0.00 0.00
129 1.15D+1.15E(T)+1.15P(T)+0.25WX+0.5L -5.55 9.73 -16.89 0.00 0.00 0.00
130 1.15D+1.15E(T)+1.15P(T)+0.25WZ+0.5L -5.50 9.71 -16.79 0.00 0.00 0.00
131 1.15D+1.15E(E)+1.15P(E) -4.27 7.51 -13.03 0.00 0.00 0.00

UPD-ME-W7-CI-CL-4103_Rev. 0 Page 39 of 39