You are on page 1of 1

Wind Load Calculation According to

ASCE 7 -16
Input
Wind Speed, V = 100 mph (Wind Map)
Bldg. Classification = I (Table 1-1 Occupancy Cat.)
Slope Exposure Category = B (Sect. 6.5.6)
Height Length Ridge Height, hr = 14.00 ft. (hr >= he) B

1 10 Eave Height, he = 10.00 ft. (he <= hr) Wind


Building Width = 80.00 ft. (Normal to Building Ridge)
Building Length = 140.00 ft. (Parallel to Building Ridge)
Bay Spacing = 20.00 ft. (Normal to Building Ridge)
Roof Type = Gable (Gable or Monoslope) =L
Topo. Factor, Kzt = 1.00 Sect. 6.5.7 I
Plan
Direct. Factor, Kd = 0.85 (Table 6-4) II
Enclosed? (Y/N/Open) Open Sect. 6.2
Gust factor 0.85

Areas Calculations Opening Details qo


hr
Ag Ao Agi Aoi Width Depth h<=
'60 he
ft^2 Sft Sft Sft ft ft
LEW = 960.00 1120.00 26187.98 3920.00 80 14
L
REW 960.00 1120.00 26187.98 3920.00 80 14
Elevation
FSW = 1400.00 1400.00 25747.98 3640.00 140 10
NSW = 1400.00 1400.00 25747.98 3640.00 140 10
Roof Surface = 11213.99 0.00 15933.99 5040.00 0 0
Roof Surface 2 = 11213.99 0.00 15933.99 119805.92 0 0
Total Building Surface Area = 27147.98 5040.00 Total Opening Area = 5040.00

'Ao' = Area of Opening in Specified Wall III


'Ag' = Gross Area of That Wall IV
'Agi' = Gross Area of Building Except Specified Wall including Walls & Roofs
Aoi' = Area of All Openings Except the Specified Wall

Clauses Ao>1.1Aoi Ao>0.37m2 or 0.01 Ag Aoi/Agi<0.2 Building


LEW = NO OK OK Enclosed
REW NO OK OK Enclosed
FSW = NO OK OK Enclosed
NSW = NO OK OK Enclosed
Roof Surface = NO NO NO Enclosed
Roof Surface 2 = NO NO NO Enclosed
Building is Enclosed

Clauses Ao>0.8Ag Building


LEW = OK Open
REW OK Open 1
FSW = OK Open 1
NSW = OK Open 1
Building is OPEN 1
1
Result Building is OPEN 1

2
3
1
1
1
1

Step 1
Wind Pressure Calculation

Resulting Parameters and Coefficients:

Roof Angle, q = 5.71 deg. 1: 10.00

External Pressure Coeff's., GCpf (Fig. 6-10):


(For values, see following wind load tabulations.)
Positive & Negative Internal Pressure Coefficients, GCpi (Figure 6-5):
+GCpi Coef. = 0.00 (positive internal pressure)
-GCpi Coef. = 0.00 (negative internal pressure)

If h < 15 then: Kh = 2.01*(15/zg)^(2/a) (Table 6-3, Case 1b)


If h >= 15 then: Kh = 2.01*(z/zg)^(2/a) (Table 6-3, Case 1b)
a= 7.00 (Table 6-2)
zg = 1200 (Table 6-2)
Kh = 0.70 (Kh = Kz evaluated at z = h)
I= 0.87 (Table 6-1) (Importance factor)

Wind Pressure
Velocity Pressure: qz = 0.00256*Kz*Kzt*Kd*V^2*I (Sect. 6.5.10, Eq. 6-15)
qh = 13.26 psf qh = 0.00256*Kh*Kzt*Kd*V^2*I (qz evaluated at z = h)

Design Net External Wind Pressures (Sect. 6.5.12.2.2):


p = qh*[(GCpf) - (+/-GCpi)] (psf, Eq. 6-18)

Step 2
Design Net External Wind Pressures

p = qz*G*Cp - qi*(+/-GCpi) for windward wall (psf), where: qi =qh (Eq. 6-17, Sect. 6.5.12.2.1)
p = qh*G*Cp - qi*(+/-GCpi) for leeward wall, sidewalls, and roof (psf), where: qi = qh (Sect. 6.5.12.2.1)

Wind Pressure
lb/ft^2
positive internal pressure negative internal pressure
Windard Wall 9.01886088 9.018860877689
Windard Roof 7.89150327 7.891503267978
Leeward Wall 3.38207283 3.382072829134
Leeward Roof 2.0292437 2.02924369748
Sides Wall 7.89150327 7.891503267978

Wind Load Calculation


lb/ft
positive internal load negative internal load
Windard Wall 180.38 180.3772175538
Windard Roof 157.83 157.8300653596
Leeward Wall 67.64 67.64145658267
Leeward Roof 40.58 40.5848739496
Sides Wall 157.83 157.8300653596

7.89 2.03 7.891503 2.0292437

9.02 2.03 2.0292437


+ Pressure
9.02 - Pressure

157.83 157.83

Side walls Side walls

Side walls Side walls

157.83 157.8301