Professional Documents
Culture Documents
Formwork Design
&
Static Calculation
ST100 Shoring
Seq. No : 30-0003422
Date : 16-Jun-21
Certified by :
Revision: 0
1
Project Name: UDG TITIWANGSA KL
Client Name: MMC GAMUDA KVMRT (UGW)
Content
No Title Page
I Drawings 2
III Appendix
A. Formwork Girder GT24 & VT-20 11
B. ST100 Shoring 12
1
Project Name: UDG TITIWANGSA KL
Client Name: MMC GAMUDA KVMRT (UGW)
I. Drawings
Plan View
Typical Section
2
Project Name: UDG TITIWANGSA KL
Client Name: MMC GAMUDA KVMRT (UGW)
Permissible Application:
Load Assumption:
1.0 Soffit (Max Concrete Beam Depth (B50): 1.50m)
3
Concrete Density (DIN EN 12812. Clause 8.2.2.1.1) = 25.00 kN/m
Calculation Class = B1
Q2,1 Slab = Concrete Load = 37.50 kN/m2
Q1 = Dead Load (DIN EN 12812. Clause 8.2.1.1) = 0.40 kN/m2
Q2,3 = Concrete operation load (DIN EN 12812. Clause 8.2.2.1.3) = 0.75 kN/m2
Q4,1 Slab = In-SITU concrete loading allowance (DIN EN 12812. Clause 8.2.3.1) = 1.75 kN/m2
The maximum secondary spacing allowed is 334mm. In this calculation, 300mm of girder spacing is used.
3
Project Name: UDG TITIWANGSA KL
Client Name: MMC GAMUDA KVMRT (UGW)
Load Assumption:
3
Concrete Density (DIN EN 12812. Clause 8.2.2.1.1) = 25.00 kN/m
Calculation Class = B1
Q2,1 Slab = Concrete Load = 15.00 kN/m2
Q1 2
= Dead Load (DIN EN 12812. Clause 8.2.1.1) = 0.40 kN/m
Q2,3 2
= Concrete operation load (DIN EN 12812. Clause 8.2.2.1.3) = 0.75 kN/m
Q4,1 Slab = In-SITU concrete loading allowance (DIN EN 12812. Clause 8.2.3.1) = 1.50 kN/m2
The maximum secondary spacing allowed is 0.451mm. In this calculation, 300mm of girder spacing is used.
4
Project Name: UDG TITIWANGSA KL
Client Name: MMC GAMUDA KVMRT (UGW)
Load Assumption:
3
Concrete Density (DIN EN 12812. Clause 8.2.2.1.1) = 25.00 kN/m
Calculation Class = B1
Q2,1 Slab = Concrete Load = 22.50 kN/m2
Q1 2
= Dead Load (DIN EN 12812. Clause 8.2.1.1) = 0.40 kN/m
Q2,3 2
= Concrete operation load (DIN EN 12812. Clause 8.2.2.1.3) = 0.75 kN/m
Q4,1 Slab = In-SITU concrete loading allowance (DIN EN 12812. Clause 8.2.3.1) = 1.75 kN/m2
The maximum secondary spacing allowed is 0.400mm. In this calculation, 300mm of girder spacing is used.
5
Project Name: UDG TITIWANGSA KL
Client Name: MMC GAMUDA KVMRT (UGW)
Load Assumption:
3
Concrete Density (DIN EN 12812. Clause 8.2.2.1.1) = 25.00 kN/m
Calculation Class = B1
Q2,1 Slab = Concrete Load = 4.38 kN/m2
Q1 2
= Dead Load (DIN EN 12812. Clause 8.2.1.1) = 0.40 kN/m
Q2,3 2
= Concrete operation load (DIN EN 12812. Clause 8.2.2.1.3) = 0.75 kN/m
Q4,1 Slab = In-SITU concrete loading allowance (DIN EN 12812. Clause 8.2.3.1) = 0.75 kN/m2
The maximum secondary spacing allowed is 0.637mm. In this calculation, 300mm of girder spacing is used.
6
Project Name: UDG TITIWANGSA KL
Client Name: MMC GAMUDA KVMRT (UGW)
7
Project Name: UDG TITIWANGSA KL
Client Name: MMC GAMUDA KVMRT (UGW)
Permissible Values
8
Project Name: UDG TITIWANGSA KL
Client Name: MMC GAMUDA KVMRT (UGW)
Permissible Values
9
Project Name: UDG TITIWANGSA KL
Client Name: MMC GAMUDA KVMRT (UGW)
Actual Permissible
* Max. Leg load = 40.89 < 41.5 (Please refer Appendix B for ST100 properties)
10
Project Name: UDG TITIWANGSA KL
Client Name: MMC GAMUDA KVMRT (UGW)
III. APPENDIX :
Appendix A
11
Project Name: UDG TITIWANGSA KL
Client Name: MMC GAMUDA KVMRT (UGW)
Appendix B
12