You are on page 1of 13

Project Name: UDG TITIWANGSA KL

Client Name: MMC GAMUDA KVMRT (UGW)

PERI Formwork Malaysia Sdn Bhd


Unit B-12-02, Level 12
Block B, East Wing, PJ8,
No23, Jalan Barat, Seksyen 8,
46050 Petaling Jaya, Selangor.

Formwork Design
&
Static Calculation
ST100 Shoring

Project : UDG TITIWANGSA KL

Title : CORBEL AREA

Client : MMC GAMUDA KVMRT(UGW), JOINT VENTURE

Seq. No : 30-0003422

Date : 16-Jun-21

Prepared by : Alfian Faidhi Ahmad

Checked by : Dan Angeles

Certified by :

Revision: 0

Drawing No. : 30-0003422-B013

1
Project Name: UDG TITIWANGSA KL
Client Name: MMC GAMUDA KVMRT (UGW)

Content

No Title Page

I Drawings 2

II Static Calculation Report 3

1.0 Soffit (Max concrete Beam depth (B50) : 1.50m) 3


1.1 Check Plywood (Depth:1.50m) 3
1.2 Soffit (Max concrete Beam depth (B31) : 0.60m) 4
1.3 Check Plywood (Depth:0.60m) 4
1.4 Soffit (Max concrete Corbel depth : 0.90m) 5
1.5 Check Plywood (Depth:0.90m) 5
1.6 Soffit (Max concrete Slab depth : 0.175m) 6
1.7 Check Plywood (Depth:0.175m) 6
1.8 VT20K Girder (Slab Depth:1.60 & 0.50m) 7
1.9 GT24 Double Girder (Worst Case) 8
1.10 ST100 Shoring 9

III Appendix
A. Formwork Girder GT24 & VT-20 11
B. ST100 Shoring 12

1
Project Name: UDG TITIWANGSA KL
Client Name: MMC GAMUDA KVMRT (UGW)

I. Drawings

Plan View

Typical Section

2
Project Name: UDG TITIWANGSA KL
Client Name: MMC GAMUDA KVMRT (UGW)

II. STATIC CALCULATIONS:

Permissible Application:

1. This calculation is calculated according to the worst case.


2. Volumetric weight of concrete 25.0kN/m3. (According to DIN EN 12812)
3. 18mm plywood bending stress < 13.3 N/mm2 and shear stress < 1.31N/mm2
4. VT20 Girder bending moment <5 kN/mm2 and shear < 11 kN
5. Double GT24 Girder bending moment <14 kN/mm2 and shear < 26 kN

Load Assumption:
1.0 Soffit (Max Concrete Beam Depth (B50): 1.50m)

3
Concrete Density (DIN EN 12812. Clause 8.2.2.1.1) = 25.00 kN/m

Slab Depth = 1.50 m

Secondary Girder Spacing (Refer plywood checking parameters) = 0.30 m

Calculation Class = B1
Q2,1 Slab = Concrete Load = 37.50 kN/m2
Q1 = Dead Load (DIN EN 12812. Clause 8.2.1.1) = 0.40 kN/m2
Q2,3 = Concrete operation load (DIN EN 12812. Clause 8.2.2.1.3) = 0.75 kN/m2
Q4,1 Slab = In-SITU concrete loading allowance (DIN EN 12812. Clause 8.2.3.1) = 1.75 kN/m2

Ʃq Slab = Q1 + Q2,1 Slab + Q2,3 + Q4,1Slab = 40.40 kN/m2

1.1 Check Plywood (18mm Thk)

The maximum secondary spacing allowed is 334mm. In this calculation, 300mm of girder spacing is used.

3
Project Name: UDG TITIWANGSA KL
Client Name: MMC GAMUDA KVMRT (UGW)

Load Assumption:

3
Concrete Density (DIN EN 12812. Clause 8.2.2.1.1) = 25.00 kN/m

1.2 Soffit (Concrete Depth (B31):0.60m) = 0.600 m

Secondary Girder Spacing (Refer plywood checking parameters) = 0.300 m

Calculation Class = B1
Q2,1 Slab = Concrete Load = 15.00 kN/m2
Q1 2
= Dead Load (DIN EN 12812. Clause 8.2.1.1) = 0.40 kN/m
Q2,3 2
= Concrete operation load (DIN EN 12812. Clause 8.2.2.1.3) = 0.75 kN/m
Q4,1 Slab = In-SITU concrete loading allowance (DIN EN 12812. Clause 8.2.3.1) = 1.50 kN/m2

Ʃq Slab Q1 + Q2,1 Slab + Q2,3 + Q4,1Slab 2


= = 17.65 kN/m

1.3 Check Plywood (18mm Thk)

The maximum secondary spacing allowed is 0.451mm. In this calculation, 300mm of girder spacing is used.

4
Project Name: UDG TITIWANGSA KL
Client Name: MMC GAMUDA KVMRT (UGW)

Load Assumption:

3
Concrete Density (DIN EN 12812. Clause 8.2.2.1.1) = 25.00 kN/m

1.4 Soffit (Concrete Depth of Corbel :0.90m) = 0.900 m

Secondary Girder Spacing (Refer plywood checking parameters) = 0.300 m

Calculation Class = B1
Q2,1 Slab = Concrete Load = 22.50 kN/m2
Q1 2
= Dead Load (DIN EN 12812. Clause 8.2.1.1) = 0.40 kN/m
Q2,3 2
= Concrete operation load (DIN EN 12812. Clause 8.2.2.1.3) = 0.75 kN/m
Q4,1 Slab = In-SITU concrete loading allowance (DIN EN 12812. Clause 8.2.3.1) = 1.75 kN/m2

Ʃq Slab Q1 + Q2,1 Slab + Q2,3 + Q4,1Slab 2


= = 25.40 kN/m

1.5 Check Plywood (18mm Thk)

The maximum secondary spacing allowed is 0.400mm. In this calculation, 300mm of girder spacing is used.

5
Project Name: UDG TITIWANGSA KL
Client Name: MMC GAMUDA KVMRT (UGW)

Load Assumption:

3
Concrete Density (DIN EN 12812. Clause 8.2.2.1.1) = 25.00 kN/m

1.6 Soffit (Concrete Depth of Slab :0.175m) = 0.175 m

Secondary Girder Spacing (Refer plywood checking parameters) = 0.300 m

Calculation Class = B1
Q2,1 Slab = Concrete Load = 4.38 kN/m2
Q1 2
= Dead Load (DIN EN 12812. Clause 8.2.1.1) = 0.40 kN/m
Q2,3 2
= Concrete operation load (DIN EN 12812. Clause 8.2.2.1.3) = 0.75 kN/m
Q4,1 Slab = In-SITU concrete loading allowance (DIN EN 12812. Clause 8.2.3.1) = 0.75 kN/m2

Ʃq Slab Q1 + Q2,1 Slab + Q2,3 + Q4,1Slab 2


= = 6.28 kN/m

1.7 Check Plywood (18mm Thk)

The maximum secondary spacing allowed is 0.637mm. In this calculation, 300mm of girder spacing is used.

6
Project Name: UDG TITIWANGSA KL
Client Name: MMC GAMUDA KVMRT (UGW)

1.8 Check VT-20K Girder

Beam Depth (B50): 1.50m)


UD Load (Concrete Depth: 1.50m ) = 40.4 kN/m2
Spacing of VT-20 Girder = 0.30 m
UDLoad per metre run on VT-20 Girder, w = 40.4 kN/m2 x 0.30 m = 12.12 kN/m

Corbel Depth : 0.9m)


UD Load (Concrete Depth: 0.90m ) = 25.4 kN/m2
Spacing of VT-20 Girder = 0.30 m
UDLoad per metre run on VT-20 Girder, w = 25.4 kN/m2 x 0.30 m = 7.62 kN/m

Beam Depth (B31): 0.6m)


UD Load (Concrete Depth: 0.60m ) = 17.7 kN/m2
Spacing of VT-20 Girder = 0.30 m
UDLoad per metre run on VT-20 Girder, w = 17.7 kN/m2 x 0.30 m = 5.30 kN/m

Slab Depth : 0.175m)


UD Load (Concrete Depth: 0.175m ) = 6.3 kN/m2
Spacing of VT-20 Girder = 0.30 m
UDLoad per metre run on VT-20 Girder, w = 6.3 kN/m2 x 0.30 m = 1.88 kN/m

7
Project Name: UDG TITIWANGSA KL
Client Name: MMC GAMUDA KVMRT (UGW)

Permissible Values

Max. Deformation = 1.524 mm < 647 mm = 2.59 mm OK!


= 250

Max. Shear = 9.15 kN < 11.00 kN OK!

Max. Moment = 2.538 kNm < 5.00 kNm OK!

Therefore VT20K Girder is satisfactory.

Please see Appendix A for VT20K Girder properties.

8
Project Name: UDG TITIWANGSA KL
Client Name: MMC GAMUDA KVMRT (UGW)

1.9 Soffit (Check GT24 Double Girder)

Beam Depth (B50): 1.50m)


P Load Max. = 16.6 kN
Spacing of VT-20 Girder = 0.300 m
UDLoad per metre run on SRU WALER, w = 16.6 kN/m2 X 0.3 m = 55.30 kN/m

Beam Depth (B31): 0.6m)


P Load Max. = 2.3 kN
Spacing of VT-20 Girder = 0.300 m
UDLoad per metre run on SRU WALER, w = 2.3 kN/m2 X 0.3 m = 7.50 kN/m

Corbel Depth : 0.9m)


P Load Max. = 9.8 kN
Spacing of VT-20 Girder = 0.300 m
UDLoad per metre run on SRU WALER, w = 9.8 kN/m2 X 0.3 m = 32.80 kN/m

Permissible Values

Max. Deformation = 0.184 mm < 718 mm = 2.872 mm OK!


= 250

Max. Shear = 24.07 kN < 26.00 kN OK!

Max. Moment = 3.811 kNm < 14.00 kNm OK!

Therefore Double Girder GT24 waler is satisfactory.

Please see Appendix A for Girder GT24 properties.

9
Project Name: UDG TITIWANGSA KL
Client Name: MMC GAMUDA KVMRT (UGW)

1.10 Check ST100 Shoring

1.5 ST100 Stacking Tower


Worst Case
Shoring ht. = 7.47 m
Application Condition (D3) = h≤8.29 m
Equivalent Perm. Leg load = 41.5 kN

Actual Permissible
* Max. Leg load = 40.89 < 41.5 (Please refer Appendix B for ST100 properties)

10
Project Name: UDG TITIWANGSA KL
Client Name: MMC GAMUDA KVMRT (UGW)

III. APPENDIX :
Appendix A

11
Project Name: UDG TITIWANGSA KL
Client Name: MMC GAMUDA KVMRT (UGW)

Appendix B

12

You might also like