SUBJECT : DRUM FILL RATES FOR DRUM AND FILL WATER TEMPERATURE
COMBINATIONS
PURPOSE : To avoid excessive stresses in the drum shell during the drum filling
operation.
PRODUCT LINE: CHECK THE PRODUCT LINE THE STANDARD IS APPLICABLE TO:
Versions
1.0 Scope
2.0 Application
700
700
650
Paragraph 2.4 *
550
500
500
450
425
400 400
350
350
150
See Para. 2.2 *
100 100
100 82 96 100 Excessive Thermal Stress Region
57
50 Paragraph 2.4 *
38 Brittle Region 25
0 Paragraph 2.3 * 0
0 50 70 100 150 200 250 300 350 400 450 500
TEMPERATURE of FILL WATER - °F
* Refer to Paragraph 2.0 for drum filling instructions for that particular region.
SUBJECT: Drum Fill Rates for Drum and Fill
STD NO. : 14-83-02
Water Temperature Combinations
INDEX : 15.17.6
DATE : 15 JULY 2003
OWNER : 8102
PAGE : 5 of 5
______________________________________________________________________________________________________
432
382
E x c e s s iv e T h e rm a l S tre s s R e g io n
P a ra g ra p h 2 .4 * 371
332
316
TEMPERATURE OF OUTSIDE SURFACE OF DRUM - °C
282
260
232
182
177
149
149
132
132
93
93
82
S e e P a ra . 2 .2 * E x c e s s iv e T h e rm a l S tre s s R e g io n
P a ra g ra p h 2 .4 *
36 38 38
38
32
14 28
B rittle R e g io n
3 P a ra g ra p h 2 .3 *
-4
-1 8 -1 8
-1 8 21 32 82 132 182 232
T E M P E R A T U R E o f F IL L W A T E R - °C
* Refer to Paragraph 2.0 for drum filling instructions for that particular region.