CONTROL PLAN
ELECTROPLATING (General Purpose Component) PAGE 1/6
Doc No:-
96001-06016-02-00
OPERATION Stag
DESCRIPTION e NO. Process Product ERROR
PROCESS CLASS SPECIFICATIONS MEASUREMENT SAMPLE CONTROL INSP.
Characteristics characteristics PROFING
No:
Step No. TECHNIQUES SIZE FREQ. METHOD BY REACTION PLAN Corrective action
Automatic
Temperature Record in Stop the plant inform to
1 _ M 60~70 Thermometer two times per shift temp. W
(Deg Cel) APSI/FM/QA/11 Maintenance dept.,
Control
Lab
Record in Addition / dilution of chemical
2 concentration _ M 40-60g/lit Titration once Twice in a Week - inspect
APSI/FM/QA/11 in tank
or
Density (Deg Record in Addition / dilution of chemical
3 _ M 4-8ºBe Hydrometer One time per day W
Beume) APSI/FM/QA/11 in tank
If sludge is in the tank transfer
Record in the soloution& clean again &
4 cleaning of tank _ M decantation in a non working day visual 100% Monthly - S
APSI/FM/QA/11 confirm the concentration &
10 Soak-Clean 11 Density
5 Dip time (min) - M 9-10 min Timer - - - PLC controlled - -
new bath preparation in a non fully drain & make Record in confirm the concentration &
6 Chemical change _ M 100% after 3 month _ S
working day New Bath APSI/FM/QA/11 Density of bath made
Lab
7 Oil content _ Mn maximum 5% By Calculation weekly _ inspect -
or
Make the level by adding
component should be fully
8 Level of solution - M visual 100% per shift - - W R.O.water. If Any abnormility
immersed
comes Inform to supervisor
if any abnormality Stop the
Temperature Automatic Record in
1 S 60~70°C Thermometer two time per shift W plant inform to Maintenance
(Deg Cel) Control APSI/FM/QA/11
dept.,
Lab
Record in Addition / dilution of chemical
2 concentration S 40-60g/lit Titration once weekly - inspect
APSI/FM/QA/11 in tank
or
Density (Deg Record in Addition / dilution of chemical
3 S 8-12 º Be Hydrometer Once Per day - W
Beume) APSI/FM/QA/111 in tank
If sludge is in the tank transfer
Record in the soloution& clean again &
4 Tank Cleaning S decantation in a non working day visual 100% monthly - S
APSI/FM/QA/11 confirm the concentration &
Density
transfer this solution
new bath preparation in a non Record in confirm the concentration &
5 Chemical change _ S to Stage no:12 then 100% after 3 month - S
working day APSI/FM/QA/11 Density
make fresh bath
20 Anodic clean 19 Cleaning of MS Record in if any abnormality comes
6 S Free From Sludge Visual & manual Once weekly W
plate APSI/FM/QA/111 inform to supervisor
Current monitering record in
7 Current Density S 25-50 ASF By Calculation once per month PLC controlled S ragister or formate once in two
hrs.
40 Water Rinse 2 15 5 Level of solution - S component should be fully immersed visual 100% per shift - - W If Any abnormility comes Inform to supervisor
Record in
6 Tank Cleaning S fully drain & filled with fresh water Once weekly - APSI/FM/QA/1 W If tank is not clean, again reclean the tank
1
Record in
1 Density (Deg Beume) M 10~15º Be Hydrometer once per day APSI/FM/QA/1 W Addition / dilution of chemical in tank
1
Record in Lab
2 concentration M 20-30 % Titration once Twice in a week APSI/FM/QA/1 inspect if there is abnormality Stop the plant inform to Supervisor
1 or
Record in
If sludge is in the tank transfer the soloution & clean again &
3 Tank Cleaning M decantation in a non working day visual 100% monthly - APSI/FM/QA/1 S
confirm the concentration & Density
1
Record in
new bath preparation in a non working
50 Acid Pickling 16 4 Chemical change free from rust M fully drain & make New Bath 100% after 3 month - APSI/FM/QA/1 S confirm the concentration & Density
day
1
5 Dip time (min) M 1 to 2 min Timer - - - PLC controlled - -
60 Water Rinse 1 17 2 Level of solution - S component should be fully immersed visual 100% per shift - - W If Any abnormility comes Inform to supervisor
Record in
3 Tank Cleaning S fully drain & filled with fresh water Once weekly - APSI/FM/QA/1 W If tank is not clean, again reclean the tank
1
1 water flow S water should over flow visual 100% Per Shift _ Visual W if water overflow not there inform to Supervisor
70 Water Rinse 2 18 2 Level of solution - S component should be fully immersed visual 100% per shift - - W If Any abnormility comes Inform to supervisor
Record in
3 Tank Cleaning S fully drain & filled with fresh water Once weekly - APSI/FM/QA/1 W If tank is not clean, again reclean the tank
1
Record in
Automatic
1 Temperature (Deg Cel) S 60~70°C Thermometer two time per shift APSI/FM/QA/1 W if any abnormality Stop the plant inform to Maintenance dept.,
Control
1
Record in Lab
2 concentration S 40-60g/lit Titration once Twice in a week - APSI/FM/QA/1 inspect Addition / dilution of chemical in tank
1 or
Record in
3 Density (Deg Beume) S 8-12 º Be Hydrometer Once Per day - APSI/FM/QA/1 W Addition / dilution of chemical in tank
1
Record in
If sludge is in the tank transfer the soloution& clean again &
4 Tank Cleaning S decantation in a non working day visual 100% monthly - APSI/FM/QA/1 S
confirm the concentration & Density
1
Record in
new bath preparation in a non working transfer this solution to Stage no:12
5 Chemical change _ S 100% after 3 month - APSI/FM/QA/1 S confirm the concentration & Density
day then make fresh bath
1
80 Anodic clean 19 Record in
6 Cleaning of MS plate S Free From Sludge Visual & manual Once weekly APSI/FM/QA/1 W if any abnormality comes inform to supervisor
1
7 Current Density S 25-50 ASF By Calculation once per month PLC controlled S Current monitering record in ragister or formate once in two hrs.
Prepared by: Mr. Deepak APPROVED BY : Mr. V. Raja CUSTOMER APPROVAL:(If Reqd) ISSUE ISSUE DATE :
D BY :
CLASS C- Critical, M - Major, S- Significant, Mn - Minor
LEGEND FOR INSPECTED BY : W - OPERATOR ; I - INSPECTOR ; S - SUPERVISOR ;
RADHE KRISHNA INDUSTRIES
CONTROL PLAN
ELECTROPLATING (General Purpose Component) PAGE 3/6 Doc No:-
CUSTOMER : ARIHANT VEHICLE MODEL:
PART NO: PART NAME BOLT FLANGE SH 6 X 16 DATE(ORIG):01/03/06
96001-06016-02-00
REVISE DATE : 25.8.2017
CORE TEAM: Mr. Harish Madan, Mr. Mahinder, Mr. V. Raja, Mr. Ashish, Mr. Vishal, Mr. Jai Singh KEY CONTACT: Mr. Vishal DVM (P.E.)
PROCESS Product MEASUREMENT SAMPLE ERROR CONTROL INSP.
OPERATION Process
DESCRIPTIO Stage NO. Characteristics characteri CLASS SPECIFICATIONS PROFIN CORRECTI
Step No. N no. stics TECHNIQUES SIZE FREQ. G METHOD BY REACTION PLAN VE ACTION
1 water flow S water should over flow visual 100% Per Shift _ Visual W if water overflow not there inform to Supervisor
component should be fully
90 Water Rinse 1 20 2 Level of solution - S visual 100% per shift - - W If Any abnormility comes Inform to supervisor
immersed
fully drain & filled with Record in
3 Tank Cleaning S Once Weekly - APSI/FM/QA/11
W If tank is not clean, again reclean the tank
fresh water
1 water flow S water should over flow visual 100% Per Shift _ Visual W if water overflow not there inform to Supervisor
component should be fully
100 Water Rinse 2 21 2 Level of solution - S visual 100% per shift - - W If Any abnormility comes Inform to supervisor
immersed
fully drain & filled with Record in
3 Tank Cleaning S Once Weekly - APSI/FM/QA/11
W If tank is not clean, again reclean the tank
fresh water
Density (Deg Record in
1 M 10~15º Be Hydrometer once per day _ APSI/FM/QA/11
W Addition / dilution of chemical in tank
Beume)
Record in
2 concentration M 20-30% Titration once Twice in a week _ APSI/FM/QA/11
Lab inspector Addition / dilution of chemical in tank
Record in If sludge is in the tank transfer the soloution& clean again & confirm the
3 Tank Cleaning M No sludge in chemical Decantation once Twice in a month _ APSI/FM/QA/11
S
concentration & Density
new bath preparation in a non fully drain & make New Record in
110 Acid Activation 22 4 Chemical change M 100% after 3 month - APSI/FM/QA/11
S confirm the concentration & Density
working day Bath
1 Water flow S water should over flow visual 100% Per Shift _ Visual W if water overflow not there inform to Supervisor
component should be fully Make up the levl by adding D.M.water. If Any abnormility comes Inform
2 Level of solution - S visual 100% per shift - - W
120 Water Rinse 23 immersed to supervisor
fully drain & filled with Record in
3 Tank Cleaning S Once Weekly - W If tank is not clean, again reclean the tank
fresh water APSI/FM/QA/11
6 Filtration S Max pressure=1.0-2.0 Kg/cm2 Pressure gauge Once two days - W if any abnormality comes inform to supervisor and maintenance dept.,
7 air agitation M Regular Visual 100% per shift _ W if any abnormality comes inform to supervisor and maintenance dept.,
Nickel metal in
8 M should be up to working level Manual once per day _ W if any abnormality comes inform to supervisor and DPM[Plating]
baskets
Record in
2 Density (Deg Baume) C 19-23 °Be Hydrometer once per day APSI/FM/QA/1 W Addition / dilution of chemical in tank
1
Record in
if any abnormality comes inform to
3 pH C 2.5-3.0 pH meter four times per shift APSI/FM/QA/1 W supervisor
1
C Nickel metal 60-70 gpl Analysis
Record in
Twice in a
4 Concentration in gpl C nickel chloride 65-75 gpl Analysis once APSI/FM/QA/1 Lab inspector Addition / dilution of chemical in tank
week
1
C Boric acid 40-50 gpl Analysis
Current monitering record in ragister
5 Current density C 18-22 ASF By Calculation once per month PLC control S or formate once in two hrs.
Prepared by: Mr. Deepak APPROVED BY : Mr. V. Raja CUSTOMER APPROVAL:(If Reqd) ISSUED BY : ISSUE DATE :
CORE TEAM: Mr. Harish Madan, Mr. Mahinder, Mr. V. Raja, Mr. Ashish, Mr. Vishal, Mr. Jai Singh KEY CONTACT: Mr. Vishal DVM (P.E.)
OPERATION
PROCESS DESCRIPTIO Stag Product MEASUREMENT SAMPLE ERROR CONTROL INSP.
NO. Process Characteristics CLASS SPECIFICATIONS CORRECTIVE ACTION
Step No. N e no. characteristics TECHNIQUES SIZE FREQ. PROFING METHOD BY REACTION PLAN
8 Nickel metal in baskets C should be up to working level Manual once per day _ W if any abnormality comes inform to supervisor and DPM[Plating]
Tank Cleaning and anode No sludge in the anode basket, no holes in the bag Record in
10 M Nil Once monthly W if any abnormality comes inform to supervisor and DPM[Plating]
bag cleaning and look for any basket damage APSI/FM/QA/11
13 D.m water quality M Conductivity should be less than 10 µSiemens/cm Conductivity meter Once per shift - - W If Any abnormility comes Inform to supervisor
Should be
Recovering the Nickel free from
1 M 2-8º Be Hydrometer once per day W Level make up of Bright Nickel bath to be done by the Drag out.
solution from the component Nickel
solution
Nickel drag
160 27 Make the level of bath by adding D.M.water.If Any abnormility
out 2 Level of solution M component should be fully immersed visual 100% per shift - - W
comes Inform to supervisor
3 D.m water quality M Conductivity should be less than 10 µSiemens/cm Conductivity meter Once per shift - - W If Any abnormility comes Inform to supervisor
Record in
4 Tank Cleaning M No sludgeat the bottom of tank Nil Once Twice in amonth W if any abnormality comes inform to supervisor and DPM[Plating]
APSI/FM/QA/11
1 water flow S water should over flow visual 100% Per Shift _ Visual W if water overflow not there inform to Supervisor
170 Water Rinse 1 25 2 Level of solution - S component should be fully immersed visual 100% per shift - - W If Any abnormility comes Inform to supervisor
1 water flow S water should over flow visual 100% Per Shift _ Visual W if water overflow not there inform to Supervisor
180 Water Rinse 2 24 2 Level of solution - S component should be fully immersed visual 100% per shift - - W If Any abnormility comes Inform to supervisor
8 D.m water quality M Conductivity should be less than 10 µSiemens/cm Conductivity meter Once per shift - - W If Any abnormility comes Inform to supervisor
Prepared by: Mr. Deepak APPROVED BY : Mr. V. Raja CUSTOMER APPROVAL:(If Reqd) ISSUED BY : ISSUE DATE :
3 - Thickness M
Record in Lab
Total Ni plating thickness =15µ min Smart STEP test Machine once one part/daily In case of abnormality inform to Prod.incharge and QA
APSI/FM/QA/11 inspector
250 Inspection
Chamber temp 49 ± 2º C Digital display - once in 8 h Automatic control
Digital display - once in 8
Humidifier temp 65 ± 2º C Automatic control
hours collected
volume of solution
precipitation rate 1-2ml/80cm2/h in the measuring jar - once in cut piece of a Two components per - Record in Lab
4 CASS life = 16 hours M 8 hours Inform to prod. Incharge & QA
pH of collected solution 3.1-3.3 at 25ºC by pH meter - once in 8 hours component month - APSI/FM/QA/11 inspector
by hydrometer-once after
Specific gravity. 1.0255-1.04 at 25ºC -
preparing new solution
- Visual-once in 8 hours -
Prepared by: Mr. Deepak APPROVED BY : Mr. V. Raja CUSTOMER APPROVAL:(If Reqd) ISSUED BY : ISSUE DATE :