You are on page 1of 38

‫ﻣﺘﺮﺟﻢ ﻣﻦ ﺍﻹﻧﺠﻠﻴﺰﻳﺔ ﺇﻟﻰ ﺍﻟﻌﺮﺑﻴﺔ ‪www.onlinedoctranslator.

com -‬‬

‫ﻣﺮﺣﻞﺍﻟﺘﺤﻜﻢ ﻓﻲ ﺍﻟﻘﺪﺭﺓ ﺍﻟﺘﻔﺎﻋﻠﻴﺔ ‪RM 9606‬‬


‫ﺗﻌﻠﻴﻤﺎﺕﺍﻟﺘﺸﻐﻴﻞ‬

‫‪1‬‬
‫ﺍﻟﺸﻜﻞ‪ :1‬ﻣﻨﻈﺮ ﻟﻠﻮﺣﺔ ﺍﻷﻣﺎﻣﻴﺔ‬

‫ﻟﻠﻄﺎﻗﺔ‪LED‬‬
‫ﻋﺮﺽﻋﺎﻣﻞ ﻭ‬
‫ﻋﻼﻣﺔﺍﻟﺘﻨﺒﻴﻪ‬
‫ﻋﺮﺽﺭﻗﻤﻲ‬
‫ﻟـ‪LED‬‬
‫‪ /‬ﻋﺎﻣﻞ ﺍﻟﻘﻮﻯ‬ ‫ﻛﻮﺱﻓﺎﻱ‬
‫ﻭﺍﻧﺎﺱﻭ‬
‫_‪+‬‬
‫ﺃﻧﺎﺱ‪ ،‬ﺃﻧﺎﺹ‬
‫ﻋﻼﻣﺔﺍﻟﺘﻨﺒﻴﻪ‬ ‫ﺇﻧﺪﻳﺎﻧﺎ‬

‫‪.‬‬
‫ﺃﻣﺒﻴﺮ‪/‬ﺃﻣﺒﻴﺮ‬ ‫ﻟـ‪LED´s‬‬
‫ﻗﺒﻌﺔ‬ ‫ﺣﺜﻲﺃﻭ‬
‫ﻟـ‪LED‬‬ ‫ﺗﻨﺎﻏﻢ‪/‬ﺍﻟﺘﻮﺍﻓﻘﻴﺎﺕ‬ ‫ﺍﻟﻮﺿﻊﺍﻟﺴﻌﻮﻱ‬
‫ﻋﺮﺽﻣﺘﻨﺎﺳﻖ‬
‫ﻭﻋﻼﻣﺔﺍﻟﺘﻨﺒﻴﻪ‬ ‫‪6‬‬ ‫‪5‬‬ ‫‪4‬‬ ‫‪3‬‬ ‫‪2‬‬ ‫‪1‬‬
‫ﻟـ‪LED´s‬‬
‫ﺍﺧﺘﻴﺎﺭﺃﻧﺎﺱ‬
‫ﺗﻢﺗﺸﻐﻴﻞ ﺍﻟﻤﺮﺍﺣﻞ‬
‫ﻋﺮﺽ‬

‫ﺍﺧﺘﻴﺎﺭﺃﻧﺎﺹﺷﺎﺷﺔ ﺍﻟﻌﺮﺽ‬
‫ﺃﻧﺎﺱ‬
‫)ﺍﺧﺘﻴﺎﺭ ﺃﻧﺎﺱﻋﺮﺽ ﺍﻟﺼﺤﺎﻓﺔ ﺃﻧﺎ‬ ‫‪/Rückspeisung‬ﺗﺠﺪﻳﺪ‬ ‫ﻟـ‪LED‬‬
‫ﺱﻭ ﺍﻧﺎﺹﻣﺤﺎﻛﺎﺓ‪(.‬‬ ‫ﺭﺩﻭﺩﺍﻟﻔﻌﻞ ﺍﻟﺴﻠﻄﺔ‬
‫ﺃﻧﺎﺹ‬ ‫ﺃﻧﺎﺱ‬ ‫ﻟﻠﺘﻨﺒﻴﻪ‪LED‬‬
‫ﺇﻧﺬﺍﺭ‪/‬ﺇﻧﺬﺍﺭ‬
‫‪+‬‬ ‫‪-‬‬
‫ﺃﺯﺭﺍﺭﻟﻠﺘﺒﺪﻳﻞ‬
‫ﻣﺎﻧﻮﻳﻞ‪/‬ﻳﺪﻭﻱ‬ ‫ﻟـ‪LED‬‬
‫ﻣﻜﺜﻒﻣﺮﺍﺣﻞ‬
‫ﺍﻟﻮﺿﻊﺍﻟﻴﺪﻭﻱ‬
‫ﻭﻳﺪﻭﻳﺎً)ﺃﻳﻀﺎً ﻟﺘﻐﻴﻴﺮ ﺍﻟﻘﻴﻢ‬ ‫ﺭﺟﻞ‬ ‫ﺃﻭﺿﺒﻂ ﺍﻟﻮﺿﻊ‬
‫ﺍﻟﻤﺤﺪﺩﺓﻣﺴﺒﻘﺎً ﺃﺛﻨﺎء ﺍﻟﺒﺮﻣﺠﺔ‬ ‫ﺗﻌﻴﻴﻦ‬
‫ﺿﺮﺭﻭﺗﻠﻒ‬

‫ﻋﻤﻠﻴﺔ(‬ ‫‪9606‬ﺭﻳﻨﺠﻴﺖ‬
‫ﺻﻨﻊﻓﻲ ﺍﻟﻤﺎﻧﻴﺎ‬ ‫‪/Blindleistungsregler‬ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻓﻲ ﺍﻟﻄﺎﻗﺔ ﺍﻟﺘﻔﺎﻋﻠﻴﺔ‬
‫ﺯﺭﺍﻟﺘﺤﺪﻳﺪ ﻟـ‬
‫ﺗﻠﻘﺎﺉﻲﺃﻭ ﻳﺪﻭﻱ‬
‫ﻋﻤﻠﻴﺔ‬

‫ﺯﺭﻟﻠﺘﺄﻛﻴﺪ‬ ‫ﺃﻧﺎﺹ= ﺍﻟﺘﻴﺎﺭ ﺍﻟﻨﺸﻂ‬ ‫•‬


‫ﺑﺮﻧﺎﻣﺞ‬ ‫ﺃﻧﺎﺱ= ﺭﺩ ﺍﻟﻔﻌﻞ ﺍﻟﺤﺎﻟﻲ‬ ‫•‬
‫ﺃﻧﺎﺱ= ﺍﻟﺘﻴﺎﺭ ﺍﻟﻈﺎﻫﺮ‬ ‫•‬
‫ﺍﺧﺘﻴﺎﺭﺍﻟﺘﻮﺍﻓﻘﻲ‬
‫ﻋﺮﺽ‬

‫ﺷﻜﻞ‪:1‬ﻣﻨﻈﺮ ﻟﺒﺎﻧﺎﻝ ﺃﻣﺎﻣﻲ‬

‫‪2‬‬
‫ﻋﺮﺽﻣﻦ ﺍﻷﺳﻔﻞ‬
‫ﺇﻧﺬﺍﺭ‬ ‫‪ 50/60‬ﻫﺮﺗﺰ‬
‫‪250‬ﻓﻮﻟﺖ ~ ‪ 3 /‬ﺃﻣﺒﻴﺮ‬ ‫‪400‬ﻓﻮﻟﺖ ~‬
‫ﻣﺮﺣﻞ‪ 380‬ﻓﻮﻟﺖ ~ ‪ 5 /‬ﺃﻣﺒﻴﺮ‬ ‫ﺃﺏ‬ ‫‪230‬ﻓﻮﻟﺖ ~‬ ‫ﻣﺎﻛﺲ‪5A‬‬
‫‪ 6 5 4 3 21‬ﺹ‬ ‫ﻏﻴﺮﻣﺘﻮﻓﺮ ‪S1 S2‬‬

‫ﺍﻟﺸﻜﻞ‪:2‬ﻋﺮﺽ ﻣﻦ ﺍﻷﺳﻔﻞ‬

‫‪3‬‬
‫ﺻﻔﺤﺔ‬ ‫ﺻﻔﺤﺔ‬ ‫ﻣﺤﺘﻮﻳﺎﺕ‬

‫‪5.8‬ﻋﺪﺩ ﺍﻟﻤﻼﻣﺴﺎﺕ ﺍﻟﻤﺴﺘﺨﺪﻣﺔ ‪25 ...‬‬ ‫‪.1‬ﻣﻠﺨﺺ ﺍﻟﺘﻌﻠﻴﻤﺎﺕ ‪7 ............‬‬


‫‪5.9‬ﺗﺤﺪﻳﺪ ﺍﻟﻤﺮﺍﺣﻞ ﺍﻟﺜﺎﺑﺘﺔ ‪25 ...‬‬
‫‪5.10‬ﺗﻌﺮﻳﻒ ﺍﺗﺼﺎﻝ ﺗﺸﻐﻴﻞ ‪ /‬ﺇﻳﻘﺎﻑ‬ ‫‪.2‬ﺍﻟﻮﻇﺎﺉﻒ ‪8 ....................................‬‬
‫‪5.11‬ﻭﺿﻊ ﺍﻻﺗﺼﺎﻝ ‪26 ...‬‬ ‫‪2.1‬ﺍﻟﺘﻌﺮﻑ ﺍﻟﺘﻠﻘﺎﺉﻲ ﻋﻠﻰ ﺍﻟﺠﻬﺪ ﻭﺍﻟﻤﺼﺪﺭ‬
‫‪5.12‬ﺿﺒﻂ ﻭﻗﺖ ﺗﻔﺮﻳﻎ ﺍﻟﻤﻜﺜﻒ‬ ‫ﺍﻟﺤﺎﻟﻲ ‪8..........‬‬
‫‪5.13‬ﺿﺒﻂ ﺩﻭﺭﻱ ‪/‬‬ ‫‪2.2‬ﺗﺤﺪﻳﺪ ﺗﻠﻘﺎﺉﻲ ﻟﻤﺮﺍﺣﻞ ﺍﻟﻤﻜﺜﻔﺎﺕ‬
‫ﺩﻭﺭﺍﻥﺍﻟﺘﺒﺪﻳﻞ ﻏﻴﺮ ﺍﻟﺪﻭﺭﻱ ‪26 .....‬‬ ‫ﺍﻟﻤﺘﺼﻠﺔ ‪8.........‬‬
‫‪5.14‬ﺿﺒﻂ ﺍﻟﺤﺪ ﺍﻷﺩﻧﻰ ﻟـ‬ ‫‪2.3‬ﺍﻹﻋﺪﺍﺩ ﺍﻟﺘﻠﻘﺎﺉﻲ ﻟـ‬
‫ﻋﺪﺩﻣﻔﺎﺗﻴﺢ ﺍﻟﺘﻨﺒﻴﻪ ‪26 ...‬‬ ‫ﺗﺒﺪﻳﻞﺗﺄﺧﻴﺮ ﺍﻟﻮﻗﺖ ‪9 ...................‬‬
‫‪5.15‬ﺇﻋﺎﺩﺓ ﺿﺒﻂ ﻋﺪﺍﺩ ﺍﻟﺘﺤﻮﻳﻞ ‪27 ...‬‬ ‫‪2.4‬ﺍﻟﺘﻐﺬﻳﺔ ﺍﻟﺮﺍﺟﻌﺔ ﻟﻠﺴﻠﻄﺔ ‪9 ...........................‬‬
‫‪5.16‬ﻧﺴﺒﺔ ﺍﻟﻤﺤﻮﻻﺕ ﺍﻟﺤﺎﻟﻴﺔ )‪27 ... (CT‬‬
‫‪5.17‬ﻧﺴﺒﺔ ﻣﺤﻮﻝ ﺍﻟﺠﻬﺪ ‪27 ...‬‬ ‫‪.3‬ﺍﻟﺘﺜﺒﻴﺖ ﻭﺍﻟﺘﻮﺻﻴﻞ ‪10 ......‬‬
‫‪5.18‬ﺍﻹﻋﺪﺍﺩ ‪5‬ﺍﻟﻌﺎﺷﺮﺍﻟﻌﺘﺒﺔ ﺍﻟﺘﻮﺍﻓﻘﻴﺔ ‪27 ...‬‬ ‫‪3.1‬ﺍﻟﺘﺮﻛﻴﺐ ‪10 ..................................‬‬
‫‪5.19‬ﺍﻹﻋﺪﺍﺩ ‪7‬ﺍﻟﻌﺎﺷﺮﺍﻟﻌﺘﺒﺔ ﺍﻟﺘﻮﺍﻓﻘﻴﺔ ‪27 ...‬‬ ‫‪3.2‬ﺗﻮﺻﻴﻞ ﺍﻟﺠﻬﺪ ‪10 ...‬‬
‫‪5.20‬ﺍﻹﻋﺪﺍﺩ ‪11‬ﺍﻟﻌﺎﺷﺮﺍﻟﻌﺘﺒﺔ ﺍﻟﺘﻮﺍﻓﻘﻴﺔ ‪28.‬‬ ‫‪3.3‬ﺍﺗﺼﺎﻝ ﺍﻟﻤﺤﻮﻝ ﺍﻟﺤﺎﻟﻲ‪11 .‬‬
‫‪5.21‬ﺍﻹﻋﺪﺍﺩ ‪13‬ﺍﻟﻌﺎﺷﺮﺍﻟﻌﺘﺒﺔ ﺍﻟﺘﻮﺍﻓﻘﻴﺔ ‪28.‬‬ ‫‪3.4‬ﺟﻬﺎﺕ ﺍﺗﺼﺎﻝ ﺍﻹﻧﺬﺍﺭ ‪11 ...........................‬‬
‫‪5.22‬ﺗﻮﺍﻓﻘﻲ ﺍﻟﺘﻴﺎﺭ ﺍﻟﺰﺍﺉﺪ‬ ‫‪3.5‬ﺟﻬﺎﺕ ﺍﺗﺼﺎﻝ ﺍﻟﺘﺤﻜﻢ ‪12 ...‬‬
‫ﺇﺷﺎﺭﺓﺍﻹﻧﺬﺍﺭ ‪28 ................................‬‬ ‫‪3.6‬ﺗﻌﻠﻴﻤﺎﺕ ﺇﺿﺎﻓﻴﺔ ‪...‬‬
‫‪5.23‬ﻗﻤﻊ‬
‫‪.4‬ﺍﻟﺘﻜﻠﻴﻒ ‪13 .........................‬‬
‫ﺇﻧﺬﺍﺭﻋﺎﻣﻞ ﺍﻟﻄﺎﻗﺔ ‪28 .....................‬‬
‫‪4.1‬ﺍﻟﺘﺸﻐﻴﻞ ﺍﻷﻭﻝ ‪13 ...................‬‬
‫‪5.24‬ﻋﺮﺽ ﺇﺟﻤﺎﻟﻲ ‪kvar ........................ 28‬‬
‫‪4.2‬ﺗﺠﺪﻳﺪ ﺍﻟﺘﻜﻠﻴﻒ ‪13 ............‬‬
‫‪.6‬ﺍﻟﻌﻤﻠﻴﺔ ‪29 ...................................‬‬
‫‪.5‬ﺍﻟﺒﺮﻣﺠﺔ )ﻣﺠﻤﻮﻋﺔ( ‪14 ...................‬‬
‫‪6.1‬ﻃﺮﻕ ﺍﻟﻌﺮﺽ ‪29 ...‬‬
‫‪5.1‬ﺗﺤﺪﻳﺪ ﻋﺎﻣﻞ ﺍﻟﻄﺎﻗﺔ ﺍﻟﻤﺴﺘﻬﺪﻑ ‪19 ...‬‬
‫‪6.2‬ﺍﻟﺘﺸﻐﻴﻞ ﺍﻟﻴﺪﻭﻱ ‪30 ...‬‬
‫‪5.2‬ﺍﻟﺘﺤﻮﻝ ﺍﻟﻤﺘﻮﺍﺯﻱ )‪20 ....................... (PS‬‬
‫‪6.3‬ﺍﻹﻧﺬﺍﺭﺍﺕ ‪31 ........................................‬‬
‫‪5.3‬ﺍﻟﺘﺤﺪﻳﺪ )‪20 .............................. (L‬‬
‫‪.7‬ﺍﻟﺒﻴﺎﻧﺎﺕ ﺍﻟﻔﻨﻴﺔ ‪33 ...........................‬‬ ‫‪5.4‬ﺗﺒﺪﻳﻞ ﺗﺄﺧﻴﺮ ﺍﻟﻮﻗﺖ ‪22 .................‬‬
‫‪5.5‬ﺗﺤﺪﻳﺪ ﺗﻴﺎﺭ ﺍﻟﻤﺮﺣﻠﺔ ﺍﻷﻭﺗﻮﻣﺎﺗﻴﻜﻲ )ﺝ ‪ /‬ﻙ( "‬
‫‪.8‬ﺍﺳﺘﻜﺸﺎﻑ ﺍﻷﺧﻄﺎء ﻭﺇﺻﻼﺣﻬﺎ ‪35 ......................‬‬ ‫ﺗﺸﻐﻴﻞ ‪ /‬ﺇﻳﻘﺎﻑ" ‪22 ...............‬‬
‫‪5.6‬ﺍﻻﺳﺘﺠﺎﺑﺔ ﺍﻟﺤﺎﻟﻴﺔ )ﺝ ‪ /‬ﻙ( ‪23 ..............‬‬
‫‪5.7‬ﺗﺒﺪﻳﻞ ﺍﻟﺘﺴﻠﺴﻞ ‪25 ...................‬‬

‫‪4‬‬
‫ﺗﻌﻠﻴﻤﺎﺕﺍﻟﺴﻼﻣﺔ ﻭﺍﻟﺘﺤﺬﻳﺮ !!‬

‫!!!ﻫﺎﻡ ‪ ،‬ﺍﻗﺮﺃ ﻗﺒﻞ ﺑﺪء ﺍﻟﺘﺸﻐﻴﻞ !!!‬

‫ﻫﺬﻩﺍﻟﻮﺣﺪﺓ‬ ‫ﻳﺠﺐﻋﻠﻰ ﺍﻟﻤﺴﺘﺨﺪﻡ ﺍﻟﺘﺄﻛﺪ ﻣﻦ ﺃﻥ ﻛﻞ ﺷﺨﺺ ﻳﺘﻌﺎﻣﻞ ﻣﻌﻪ‬ ‫•‬


‫ﻫﻮﺍﻟﻮﺣﺪﺓ‬ ‫ﻳﺠﺐﺃﻥ ﻳﻌﺮﻑ ﺗﻌﻠﻴﻤﺎﺕ ﺍﻟﺘﺸﻐﻴﻞ ﻫﺬﻩ ﻭﺃﻥ ﻳﺘﻌﺎﻣﻞ ﻣﻌﻬﺎ ﻭﻓﻘﺎً‬
‫ﻟﺬﻟﻚ‪.‬‬

‫ﺫﻣﻦ ﻗﺒﻞ‬ ‫ﻳﺠﺐﻗﺮﺍءﺓ ﺗﻌﻠﻴﻤﺎﺕ ﺍﻟﺘﺸﻐﻴﻞ ﻫﺬﻩ ﺑﺎﻟﻜﺎﻣﻞ ﻋﻨﺪ ﺗﺮﻛﻴﺐ‬ ‫•‬
‫ﺍﻟﻮﺣﺪﺓﻭﺗﺸﻐﻴﻠﻬﺎ‪.‬‬
‫ﺍﻹﺿﺎﻓﺎﺕ‪.‬‬ ‫ﺍﻟﻤﻀﻲﻗﺪﻣﺎ ﻓﻘﻂ ﻭﻓﻘﺎ ﻟﺘﻌﻠﻴﻤﺎﺕ ﺍﻟﺘﺸﻐﻴﻞ ﻫﺬﻩ‬ ‫•‬
‫ﻥﻫﺬﺍ‬ ‫ﻳﺠﺐﺗﺮﻛﻴﺐ ﻭﺣﺪﺓ ﺍﻟﻤﻔﻮﺿﻴﻦ ﻓﻘﻂ ﻣﻦ ﻗﺒﻞ ﺍﻷﻓﺮﺍﺩ‬ ‫•‬
‫ﺇﺩ‪.‬‬ ‫ﺍﻟﻤﺪﺭﺑﻴﻦ‪.‬ﻳﺠﺐ ﻣﺮﺍﻋﺎﺓ ﺍﻟﻘﻮﺍﻋﺪ ﻭﺍﻟﻠﻮﺍﺉﺢ ﺍﻟﻤﺤﺪﺩﺓ‬
‫ﺍﻟﻮﺣﺪﺓﺗﺤﺖ ﺍﻟﻄﺎﻗﺔ ﻭﻳﺠﺐ ﻋﺪﻡ ﻓﺘﺤﻬﺎ‪.‬‬ ‫•‬
‫‪-‬ﻳﺨﺪﻉ ‪lled،‬‬ ‫ﻓﻲﺣﺎﻟﺔ ﺗﻠﻒ ﺍﻟﻮﺣﺪﺓ ﺑﺸﻜﻞ ﻭﺍﺿﺢ ‪ ،‬ﻳﺠﺐ ﻋﺪﻡ‬ ‫•‬
‫ﺗﺮﻛﻴﺒﻬﺎﻭﺗﺸﻐﻴﻠﻬﺎ‪.‬‬
‫ﺃﻛﻠﺖﺑﻌﺪ‬ ‫ﺍﻓﺼﻞﺍﻟﻮﺣﺪﺓ ﻋﻠﻰ ﺍﻟﻔﻮﺭ ﺇﺫﺍ ﻛﺎﻧﺖ ﻻ ﺗﻌﻤﻞ‪.‬‬ ‫•‬

‫ﻣﻨﺘﺞ‪.‬‬ ‫ﻳﺠﺐﻣﺮﺍﻋﺎﺓ ﺟﻤﻴﻊ ﺍﻟﻘﻮﺍﻧﻴﻦ ﻭﺍﻷﻧﻈﻤﺔ ﺍﻟﻤﺘﻌﻠﻘﺔ ﺑﺬﻟﻚ‬ ‫•‬

‫ﺍﻹﺿﺎﻓﺎﺕﻣﻦ‬ ‫ﺑﺎﻹﺿﺎﻓﺔﺇﻟﻰ ﺫﻟﻚ ‪ ،‬ﻳﺠﺐ ﻣﺮﺍﻋﺎﺓ ﺟﻤﻴﻊ ﺃﻧﻈﻤﺔ ﺍﻟﺘﺤﻜﻢ ﻓﻲ‬


‫ﺍﻟﻄﺎﻗﺔﺍﻟﺘﻔﺎﻋﻠﻴﺔ ﻭﺍﻟﺘﻌﻠﻴﻤﻴﺔ ﺍﻟﺨﺎﺻﺔ ﺑﺎﻟﺴﻼﻣﺔ‪.‬‬

‫‪5‬‬
6
‫ﺇﺫﺍﻟﻢ ﺗﻈﻬﺮ ﺃﻱ ﺃﺭﻗﺎﻡ ﻋﻠﻰ ﺍﻟﺸﺎﺷﺔ ‪،‬‬ ‫‪.1‬ﻣﻠﺨﺺ ﺍﻟﺘﻌﻠﻴﻤﺎﺕ‬
‫ﻓﻴﺠﺐﻓﺼﻞ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻟﻔﺘﺮﺓ ﻭﺟﻴﺰﺓ‬
‫ﻋﻦﻣﺼﺪﺭ ﺍﻟﺠﻬﺪ ﻭﺍﻟﻀﻐﻂ ﻋﻠﻰ ﺯﺭ "‪"Set‬‬ ‫ﻋﻨﺪﺍﻟﺘﺴﻠﻴﻢ ‪ ،‬ﻳﺘﻢ ﺗﻌﻴﻴﻦ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻋﻠﻰ ﺍﻟﻘﻴﻢ‬
‫ﻣﺮﺓﺃﺧﺮﻯ ﻭﻓﻘﺎً ﻟـ ‪.(c‬‬ ‫ﺍﻟﻘﻴﺎﺳﻴﺔﺍﻟﻤﺒﺮﻣﺠﺔ ﻣﺴﺒﻘﺎً‪.‬‬
‫)ﺍﻧﻈﺮ ﺍﻟﺠﺪﻭﻝ ‪ ، 1‬ﺍﻟﺼﻔﺤﺎﺕ ‪ 15‬ﺇﻟﻰ ‪(17‬‬
‫ﻩ( ﻟﺘﺄﻛﻴﺪ ﺍﻟﻘﻴﻤﺔ ﺍﺿﻐﻂ ﻋﻠﻰ ﺍﻟﺰﺭ "ﺗﻌﻴﻴﻦ" ﻣﺮﺓ‬ ‫ﻣﺮﺣﻞﺍﻟﺘﺤﻜﻢ ﻓﻲ ﺍﻟﻘﺪﺭﺓ ﺍﻟﺘﻔﺎﻋﻠﻴﺔ ‪ RM 9606‬ﺫﺍﺗﻲ‬
‫ﺃﺧﺮﻯ‪.‬ﺳﻴﻈﻬﺮ "‪ "-02-‬ﻋﻠﻰ ﺍﻟﺸﺎﺷﺔ‪.‬‬ ‫ﺍﻟﺘﻨﻈﻴﻢ)ﺃﻱ ﺃﻧﻪ ﻳﻜﺘﺸﻒ ﻭﻳﻀﺒﻂ ﺍﺗﺼﺎﻝ ﻃﻮﺭ ﺍﻟﺠﻬﺪ‬
‫ﻭﺍﻟﺘﺮﺩﺩﻭﻣﻨﺤﻨﻰ ﺍﻻﺳﺘﺠﺎﺑﺔ )ﻧﺴﺒﺔ ‪ (c / k‬ﺗﻠﻘﺎﺉﻴﺎً(‪.‬‬
‫ﻭ( ﺍﺿﻐﻂ ﺍﻵﻥ ﻋﻠﻰ ﺍﻟﺰﺭ "‪ "-‬ﻣﺮﺗﻴﻦ ﺣﺘﻰ ﻳﻈﻬﺮ‬
‫"‪ "END‬ﻋﻠﻰ ﺍﻟﺸﺎﺷﺔ‪ .‬ﻗﻢ ﺑﺘﺨﺰﻳﻦ ﻫﺬﻩ ﺍﻟﻘﻴﻤﺔ‬
‫ﻋﻦﻃﺮﻳﻖ ﺍﻟﻀﻐﻂ ﻋﻠﻰ ﺍﻟﺰﺭ "ﺗﻌﻴﻴﻦ"‪ .‬ﻳﺘﻢ ﺍﻵﻥ‬ ‫ﻗﺒﻞﺃﻥ ﻳﺘﻢ ﺗﺸﻐﻴﻞ ﻧﻈﺎﻡ ﺍﻟﺘﺤﻜﻢ ﻓﻲ ﺍﻟﻘﺪﺭﺓ‬
‫ﺗﺨﺰﻳﻦﻋﺎﻣﻞ ﺍﻟﻄﺎﻗﺔ ﺍﻟﻤﺴﺘﻬﺪﻑ ﺑﺸﻜﻞ ﺩﺍﺉﻢ‪.‬‬ ‫ﺍﻟﺘﻔﺎﻋﻠﻴﺔ ‪،‬ﻳﺠﺐ ﺑﺮﻣﺠﺔ ﻋﺎﻣﻞ ﺍﻟﻘﺪﺭﺓ ﺍﻟﻤﺴﺘﻬﺪﻑ‪.‬‬

‫ﻛﻴﻔﻴﺔﺑﺮﻣﺠﺔ ‪:Control Relay‬‬


‫ﻟﻌﺮﺽﺍﻟﻘﻴﻢ ﺍﻟﺼﺤﻴﺤﺔ ﻟﻠﻄﺎﻗﺔ ﻭﺍﻟﺘﻴﺎﺭ ‪ ،‬ﺃﺩﺧﻞ ﻧﺴﺐ‬
‫ﻣﺤﻮﻝﺍﻟﺘﻴﺎﺭ ﻭﺍﻟﺠﻬﺪ‬ ‫ﺃ( ﻳﺠﺐ ﺗﻮﺻﻴﻞ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻛﻤﺎ ﻫﻮ ﻣﻮﺿﺢ ﻓﻲ )‬
‫ﺍﻧﻈﺮﺍﻟﺼﻔﺤﺔ ‪.(11‬‬
‫)ﺍﻧﻈﺮ ﺍﻷﻗﺴﺎﻡ ‪ 5.16‬ﻭ ‪.(5.17‬‬ ‫ﺏ( ﺗﻄﺒﻴﻖ ﺍﻟﺠﻬﺪ ﻋﻠﻰ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ‪ :‬ﻳﻈﻬﺮ "‪"---‬‬
‫ﻋﻠﻰﺍﻟﺸﺎﺷﺔ ﺍﻟﺮﻗﻤﻴﺔ‪ .‬ﻳﺤﺪﺩ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﺍﻵﻥ‬
‫ﻟﻤﻨﻊﺇﻋﺎﺩﺓ ﺍﻟﺒﺮﻣﺠﺔ ﻏﻴﺮ ﺍﻟﻤﻘﺼﻮﺩﺓ ‪ ،‬ﻻ ﻳﻤﻜﻦ ﺗﻨﺸﻴﻂ‬
‫ﻣﻮﻗﻊﻣﺼﺪﺭ ﺍﻟﺘﻴﺎﺭ ﻭﺍﻟﺠﻬﺪ‪ .‬ﺗﺴﺘﻐﺮﻕ ﻫﺬﻩ ﺍﻟﻌﻤﻠﻴﺔ‬
‫ﺍﻟﻮﺿﻊﺍﻟﻤﻀﺒﻮﻁ ﺇﻻ ﻓﻲ ﻏﻀﻮﻥ ﺃﻭﻝ ‪ 5‬ﺩﻗﺎﺉﻖ ﺑﻌﺪ‬
‫ﺩﻗﻴﻘﺘﻴﻦﻋﻠﻰ ﺍﻷﻗﻞ ﻭ ‪ 15‬ﺩﻗﻴﻘﺔ ﻛﺤﺪ ﺃﻗﺼﻰ‪ .‬ﻳﺘﻢ‬
‫ﺗﻄﺒﻴﻖﺟﻬﺪ ﺍﻟﺘﺸﻐﻴﻞ‪ .‬ﺇﺫﺍ ﺗﻢ ﺗﻨﺸﻴﻂ ﻭﺿﻊ ﺍﻟﻀﺒﻂ‬
‫ﻋﺮﺽﻋﺎﻣﻞ ﺍﻟﻄﺎﻗﺔ‪) .‬ﺇﺫﺍ ﻟﻢ ﻳﻜﻦ ﺍﻷﻣﺮ ﻛﺬﻟﻚ ‪،‬‬
‫ﺧﻼﻝﺃﻭﻝ ‪ 5‬ﺩﻗﺎﺉﻖ ‪ ،‬ﻓﻠﺪﻳﻚ ﺳﺎﻋﺔ ﻭﺍﺣﺪﺓ ﻹﻛﻤﺎﻝ‬
‫ﺍﻧﻈﺮﺍﻟﻘﺴﻢ ‪ .8‬ﺍﻟﺼﻔﺤﺔ ‪.(35‬‬
‫ﺍﻟﺒﺮﻣﺠﺔ‪.‬ﻣﻦ ﺃﺟﻞ ﺍﻟﺤﺼﻮﻝ ﻋﻠﻰ ﺍﻟﻮﺿﻊ ﺍﻟﻤﺤﺪﺩ ﻣﺮﺓ‬
‫ﺃﺧﺮﻯﺑﻌﺪ ﻫﺬﻩ ﺍﻟﻔﺘﺮﺓ ﺍﻟﺰﻣﻨﻴﺔ ‪ ،‬ﻳﺠﺐ ﻓﺼﻞ ﻣﺮﺣﻞ‬
‫ﺍﻟﺘﺤﻜﻢﻟﻔﺘﺮﺓ ﻭﺟﻴﺰﺓ ﻋﻦ ﻣﺼﺪﺭ ﺍﻟﺠﻬﺪ‪.‬‬
‫ﺝ( ﺍﺿﻐﻂ ﻋﻠﻰ ﺯﺭ "‪ "Set‬ﻟﻤﺪﺓ ‪ 8‬ﺛﻮﺍﻥ‪ .‬ﺳﻴﻈﻬﺮ‬
‫"‪ "-01-‬ﻋﻠﻰ ﺍﻟﺸﺎﺷﺔ ﺍﻟﺮﻗﻤﻴﺔ ﻭﻳﻮﻣﺾ ﻣﺆﺷﺮ‬
‫‪" LED‬ﺍﻟﻴﺪﻭﻱ"‪.‬‬
‫ﺩ( ﻣﻦ ﺧﻼﻝ ﺍﻟﻀﻐﻂ ﻋﻠﻰ ﺯﺭ "‪ ، "Set‬ﻳﺘﻢ ﻋﺮﺽ‬
‫ﻓﻲﺍﻟﺼﻔﺤﺎﺕ ﻣﻦ ‪ 15‬ﺇﻟﻰ ‪ ، 17‬ﻳﺘﻢ ﺳﺮﺩ ﺟﻤﻴﻊ ﺍﻟﻘﻴﻢ‬
‫ﻋﺎﻣﻞﺍﻟﻄﺎﻗﺔ ﺍﻟﻤﺴﺘﻬﺪﻑ‪ .‬ﺇﺫﺍ ﻟﺰﻡ ﺍﻷﻣﺮ ‪ ،‬ﺃﻋﺪ‬
‫ﺍﻟﻘﻴﺎﺳﻴﺔﺍﻟﻤﺒﺮﻣﺠﺔ ﻣﺴﺒﻘﺎً ﻭﻧﻄﺎﻗﺎﺕ ﺑﺮﺍﻣﺠﻬﺎ‪ .‬ﻳﺘﻢ‬
‫ﺍﻟﺒﺮﻣﺠﺔﺇﻟﻰ ﺃﻗﺮﺏ ﻗﻴﻤﺔ ﺃﻋﻠﻰ ﺃﻭ ﺃﻗﻞ ﺑﺎﻟﻀﻐﻂ‬
‫ﻭﺻﻒﻭﻇﻴﻔﺔ ﺍﻟﻘﻴﻢ ﺍﻟﻘﻴﺎﺳﻴﺔ ﺍﻟﻤﺒﺮﻣﺠﺔ ﻣﺴﺒﻘﺎً ﻓﻲ‬
‫ﻋﻠﻰﺍﻟﺰﺭ "‪ "+‬ﺃﻭ "‪ "-‬ﺣﺘﻰ ﻳﺘﻢ ﻋﺮﺽ ﻋﺎﻣﻞ ﺍﻟﻄﺎﻗﺔ‬
‫ﺍﻟﻘﺴﻢ‪.5‬‬
‫ﺍﻟﻤﺴﺘﻬﺪﻑﺍﻟﻤﻄﻠﻮﺏ‪.‬‬

‫‪7‬‬
‫‪2.1‬ﺍﻟﺘﻌﺮﻑ ﺍﻟﺘﻠﻘﺎﺉﻲ ﻋﻠﻰ ﺍﻟﺠﻬﺪ‬ ‫‪.2‬ﻭﻇﺎﺉﻒ‬
‫ﻭﺍﻟﻤﺼﺪﺭﺍﻟﺤﺎﻟﻲ‬
‫ﻳﺘﻢﺣﺴﺎﺏ ﺍﻟﻄﺎﻗﺔ ﺍﻟﺘﻔﺎﻋﻠﻴﺔ ﻭﺃﺟﺰﺍء ﺍﻟﻄﺎﻗﺔ ﺍﻟﻨﺸﻄﺔ‬
‫ﻋﻨﺪﻣﺎﻳﺘﻢ ﺗﻄﺒﻴﻖ ﺍﻟﺠﻬﺪ ﻓﻲ ﺍﻟﺒﺪﺍﻳﺔ ﻋﻠﻰ ﻣﺮﺣﻞ‬
‫ﻟﻤﺼﺪﺭﺍﻟﻄﺎﻗﺔ ﺑﺸﻜﻞ ﻣﺴﺘﻤﺮ ﻓﻲ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻣﻦ‬
‫ﺍﻟﺘﺤﻜﻢ ‪،‬ﻓﺈﻧﻪ ﻳﺤﺪﺩ ﻣﻮﻗﻊ ﻣﺼﺎﺩﺭ ﺍﻟﺘﻴﺎﺭ ﻭﺍﻟﺠﻬﺪ )‬
‫ﺍﻟﺠﻬﺪﺍﻟﻤﻘﺎﺱ ﻭﺇﺷﺎﺭﺍﺕ ﻣﺤﻮﻝ ﺍﻟﺘﻴﺎﺭ‪ .‬ﺇﺫﺍ ﺗﺠﺎﻭﺯ ﺟﺰء‬
‫ﺩﻭﺭﺍﻥﺍﻟﻄﻮﺭ ﺍﻟﺘﻠﻘﺎﺉﻲ( ‪ ،‬ﺃﻱ ﺃﻧﻪ ﻳﺤﺪﺩ ﻓﻲ ﺃﻱ ﻣﺮﺣﻠﺔ‬
‫ﺍﻟﻘﺪﺭﺓﺍﻟﺘﻔﺎﻋﻠﻴﺔ ﻗﻴﻢ ﻋﺘﺒﺔ ﻣﻌﻴﻨﺔ ‪ ،‬ﻭﺍﻟﺘﻲ ﻗﺎﻡ ﻣﺮﺣﻞ‬
‫ﻭﻓﻲﺃﻱ ﺯﺍﻭﻳﺔ ﻳﺘﻢ ﺗﻮﺻﻴﻞ ﺍﻟﻤﺴﺎﺭ ﺍﻟﺤﺎﻟﻲ ﻭﻣﺴﺎﺭ‬
‫ﺍﻟﺘﺤﻜﻢﺑﻘﻴﺎﺳﻬﺎ ﻓﻲ ﻭﻗﺖ ﺍﻟﺘﻜﻴﻒ ﺍﻟﺘﻠﻘﺎﺉﻲ ﺃﻭ ﺗﻢ‬
‫ﺍﻟﺠﻬﺪ‪.‬ﺇﺫﺍ ﻓﺸﻞ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻓﻲ ﺗﺤﺪﻳﺪ ﻣﺼﺪﺭ‬
‫ﺗﻌﻴﻴﻨﻬﺎﻭﻓﻘﺎً ﻟﻠﻘﺴﻢ ‪ ، 5‬ﻓﺴﻴﺘﻢ ﺇﺟﺮﺍء ﺗﺒﺪﻳﻞ ﻋﻨﺪ‬
‫ﺍﻟﺘﻴﺎﺭﻭﺍﻟﺠﻬﺪ ﺑﺴﺒﺐ ﻋﺪﻡ ﺍﺳﺘﻘﺮﺍﺭ ﺍﻟﻄﺎﻗﺔ ‪ ،‬ﻛﺮﺭ‬
‫ﻣﺨﺮﺟﺎﺕﺍﻟﺘﺒﺪﻳﻞ‪.‬‬
‫ﺍﻹﺟﺮﺍءﻋﻨﺪﻣﺎ ﺗﺴﺘﻘﺮ ﺍﻟﻄﺎﻗﺔ‪ .‬ﻣﻦ ﺍﻟﻤﻤﻜﻦ ﺃﻳﻀﺎً‬
‫ﺑﺮﻣﺠﺔﺍﻟﺘﺪﺭﻳﺞ ﻳﺪﻭﻳﺎً )ﺭﺍﺟﻊ ﺍﻟﻘﺴﻤﻴﻦ ‪ 5.10‬ﻭ ‪.(5.11‬‬

‫ﻓﻲﺣﺎﻟﺔ ﺍﻟﺘﻴﺎﺭ ﺍﻟﺘﻔﺎﻋﻠﻲ ﺍﻻﺳﺘﻘﺮﺍﺉﻲ )ﺍﻟﻘﺪﺭﺓ‬


‫ﺍﻟﺘﻔﺎﻋﻠﻴﺔﺍﻟﺤﺜﻴﺔ( ‪ ،‬ﻳﺘﻢ ﺇﻏﻼﻕ ﻭﺍﺣﺪ ﺃﻭ ﺃﻛﺜﺮ ﻣﻦ ﺟﻬﺎﺕ‬
‫ﺍﻻﺗﺼﺎﻝﻟﻠﺘﺤﻜﻢ ﻓﻲ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻓﻲ ﺍﻟﻘﺪﺭﺓ‬
‫ﺍﻟﺘﻔﺎﻋﻠﻴﺔﺑﻌﺪ ﺍﻟﺘﺄﺧﻴﺮ ﺍﻟﺰﻣﻨﻲ ﺍﻟﻤﺒﺮﻣﺞ ﻣﺴﺒﻘﺎً‪.‬‬
‫ﻳﺘﻢﺑﺪء ﺇﻋﺎﺩﺓ ﺿﺒﻂ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻭﺇﻋﺎﺩﺓ‬
‫ﺗﺤﺪﻳﺪﻣﺼﺎﺩﺭ ﺍﻟﺠﻬﺪ ﻭﺍﻟﺘﻴﺎﺭ ﻋﻦ ﻃﺮﻳﻖ‬
‫ﻳﺆﺩﻱﻫﺬﺍ ﺇﻟﻰ ﻗﻴﺎﻡ ‪ RM 9606‬ﺑﺘﺒﺪﻳﻞ ﻣﺮﺍﺣﻞ‬
‫ﺍﻟﻀﻐﻂﻋﻠﻰ ﺍﻷﺯﺭﺍﺭ "‪ "+‬ﻭ "ﺍﻟﻀﺒﻂ" ﻓﻲ‬
‫ﺍﻟﻤﻜﺜﻒﺇﻟﻰ ﻣﺼﺪﺭ ﺍﻟﻄﺎﻗﺔ ‪ ،‬ﻋﻨﺪ ﺍﻻﻗﺘﻀﺎء ‪ ،‬ﻣﻦ ﺃﺟﻞ‬
‫ﻭﻗﺖﻭﺍﺣﺪ ﻟﻤﺪﺓ ‪ 8‬ﺛﻮﺍﻥ ٍﻋﻠﻰ ﺍﻷﻗﻞ‪.‬‬
‫ﺗﺤﻘﻴﻖﻋﺎﻣﻞ ﺍﻟﻄﺎﻗﺔ ﺍﻟﻤﺴﺘﻬﺪﻑ ﺍﻟﻤﺒﺮﻣﺞ‪ .‬ﺇﺫﺍ ﺗﻢ‬
‫ﺗﻘﻠﻴﻞﺟﺰء ﺍﻟﺘﻴﺎﺭ ﺍﻟﺘﻔﺎﻋﻠﻲ ﺍﻻﺳﺘﻘﺮﺍﺉﻲ ﻣﻦ ﺍﻟﺤﻤﻞ ‪،‬‬
‫ﻓﺈﻥﺍﻟﺰﻳﺎﺩﺓ ﻓﻲ ﺍﻟﺘﻴﺎﺭ ﺍﻟﺘﻔﺎﻋﻠﻲ ﺗﺆﺩﻱ ﺇﻟﻰ ﺇﻳﻘﺎﻑ‬
‫‪2.2‬ﺍﻟﺘﻌﺮﻑ ﺍﻟﺘﻠﻘﺎﺉﻲ ﻋﻠﻰ ﻣﺮﺍﺣﻞ‬
‫ﺗﺸﻐﻴﻞﻣﺮﺍﺣﻞ ﺍﻟﻤﻜﺜﻒ‪.‬‬
‫ﺍﻟﻤﻜﺜﻒﺍﻟﻤﺘﺼﻞ‬
‫ﺑﻌﺪﺗﺤﺪﻳﺪ ﺍﻟﺠﻬﺪ ﻭﺗﺤﺪﻳﺪ ﺍﻟﻤﺼﺪﺭ ﺍﻟﺤﺎﻟﻲ ‪ ،‬ﻳﻘﻮﻡ‬
‫‪ RM9606‬ﺗﻠﻘﺎﺉﻴﺎً ﺑﺤﺴﺎﺏ ﺗﻌﺮﻳﻒ ‪ .c / k‬ﺃﺛﻨﺎء‬ ‫ﻳﺴﻤﺢﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ‪ RM 9606‬ﺑﻤﺠﻤﻮﻋﺔ ﻣﺘﻨﻮﻋﺔ‬
‫ﻋﻤﻠﻴﺔﺗﺤﺪﻳﺪ ﺍﻟﻬﻮﻳﺔ ‪ ،‬ﻳﺘﻢ ﺗﺸﻐﻴﻞ ﻭﺇﻳﻘﺎﻑ ﺟﻤﻴﻊ‬ ‫ﻣﻦﺍﻹﻋﺪﺍﺩﺍﺕ ﺍﻟﻤﻤﻜﻨﺔ ﻟﺘﻠﺒﻴﺔ ﺍﻟﺸﺮﻭﻁ ﻓﻲ ﺍﻟﻤﻮﻗﻊ‪.‬‬
‫ﺟﻬﺎﺕﺍﺗﺼﺎﻝ ﺍﻟﺘﺤﻜﻢ ﻓﻲ ﺍﻟﻤﺮﺣﻞ ﺑﺸﻜﻞ ﻓﺮﺩﻱ ﻣﺮﺓ‬ ‫ﺗﻌﻤﻞﻋﻤﻠﻴﺎﺕ ﺍﻟﺘﺮﺣﻴﻞ ﺍﻟﺪﻭﺭﻳﺔ ﻋﻠﻰ ﺇﻃﺎﻟﺔ ﻋﻤﺮ ﺟﻤﻴﻊ‬
‫ﺃﺧﺮﻯ‪.‬ﻳﺘﻢ ﺑﻌﺪ ﺫﻟﻚ ﺗﺨﺰﻳﻦ ﺗﻴﺎﺭﺍﺕ ﺍﻟﻤﺮﺣﻠﺔ ﺍﻟﺘﻲ ﺗﻢ‬ ‫ﺍﻷﺟﻬﺰﺓﺍﻟﻤﺘﺼﻠﺔ ﻋﻦ ﻃﺮﻳﻖ ﺣﺴﺎﺏ ﻣﺘﻮﺳﻂ ﻃﻮﻝ‬
‫ﺍﻟﺘﺤﻘﻖﻣﻨﻬﺎ‪ .‬ﺗﺤﺪﺩ ﻫﺬﻩ ﺍﻟﻘﻴﻢ ﺗﺴﻠﺴﻞ ﺍﻟﻤﺮﺣﻠﺔ‪.‬‬ ‫ﺍﻟﻮﻗﺖﺍﻟﺬﻱ ﻳﺘﻢ ﻓﻴﻪ ﺗﺸﻐﻴﻞ ﻣﺮﺍﺣﻞ ﺍﻟﻤﻜﺜﻒ‪ .‬ﻳﺘﻢ‬
‫ﻭﺑﻬﺬﻩﺍﻟﻄﺮﻳﻘﺔ ﻳﻤﻜﻦ ﺃﻳﻀﺎً ﺗﺤﺪﻳﺪ ﻣﺨﺮﺟﺎﺕ ﺍﻟﺘﺤﻮﻳﻞ‬ ‫ﺗﺄﻣﻴﻦﺍﻹﺷﺮﺍﻑ ﺍﻟﻔﻌﺎﻝ ﻋﻠﻰ ﻧﻈﺎﻡ ﺍﻟﺘﺤﻜﻢ ﻓﻲ ﺍﻟﻄﺎﻗﺔ‬
‫ﺍﻟﻤﺴﺘﺨﺪﻣﺔ‪.‬‬ ‫ﺍﻟﺘﻔﺎﻋﻠﻴﺔ)ﺑﻨﻚ ﻣﻜﺜﻒ( ﻣﻦ ﺧﻼﻝ ﻋﺮﺽ ﻋﺎﻣﻞ ﺍﻟﻄﺎﻗﺔ‪.‬‬

‫‪8‬‬
‫ﻣﻠﺤﻮﻇﺔ‪:‬‬

‫ﻓﻲﺣﺎﻟﺔ ﺷﺒﻜﺎﺕ ﺍﻟﺠﻬﺪ ﺍﻟﻤﻨﺨﻔﺾ ﺍﻟﺘﻲ ﻳﺘﻢ ﺗﻐﺬﻳﺘﻬﺎ‬ ‫ﻻﻳﺘﻢ ﺗﻨﻔﻴﺬ ﻋﻤﻠﻴﺎﺕ ﺍﻟﺘﺤﺪﻳﺪ ﺍﻟﺘﻠﻘﺎﺉﻲ ﻟﻠﺠﻬﺪ‬
‫ﺑﻮﺍﺳﻄﺔﻋﺪﺓ ﻣﺤﻮﻻﺕ ﺗﻌﻤﻞ ﺑﺎﻟﺘﻮﺍﺯﻱ ‪ ،‬ﻳﺘﻢ ﺗﻮﺯﻳﻊ‬ ‫ﻭﺍﻟﻤﺼﺪﺭﺍﻟﺤﺎﻟﻲ ﻭ ‪ /‬ﺃﻭ ﺍﻟﺘﺤﺪﻳﺪ ﺍﻟﺘﻠﻘﺎﺉﻲ ﻟﻤﺮﺍﺣﻞ‬
‫ﺗﻴﺎﺭﺍﻟﻤﻜﺜﻒ ﻋﻠﻰ ﺟﻤﻴﻊ ﺍﻟﻤﺤﻮﻻﺕ‪ .‬ﺇﺫﺍ ﻛﺎﻧﺖ‬ ‫ﺍﻟﻤﻜﺜﻒﺇﻻ ﻋﻨﺪ ﺍﻟﺘﺒﺪﻳﻞ ﺃﻭ ﺍﻟﻀﻐﻂ ﻋﻠﻰ ﻣﺠﻤﻮﻋﺔ‬
‫ﺍﻟﻘﻴﺎﺳﺎﺕﻟﻴﺲﻳﺘﻢ ﺇﺟﺮﺍﺅﻩ ﻋﺒﺮ ﻣﺤﻮﻝ ﺗﺠﻤﻴﻊ ‪،‬‬ ‫ﺍﻷﺯﺭﺍﺭ"‪ "+‬ﻭ "‪ "-‬ﻭ "ﺍﻟﻀﺒﻂ" ﻟﻤﺪﺓ ﺩﻗﻴﻘﺔ‪ 8 .‬ﺛﻮﺍﻥ‪.‬‬
‫ﻭﻳﻜﻮﻥﺍﻟﺘﻐﻴﻴﺮ ﺍﻟﺤﺎﻟﻲ ﺍﻟﻤﻘﺎﺱ ﺑﻮﺍﺳﻄﺔ ﻣﺮﺣﻞ‬
‫ﺍﻟﺘﺤﻜﻢﻣﻨﺨﻔﻀﺎً ﺟﺪﺍً ﻋﻨﺪ ﺍﻟﺘﺒﺪﻳﻞ ﻋﻠﻰ ﻣﺮﺍﺣﻞ‬
‫ﺍﻟﻤﻜﺜﻒ ‪،‬ﻣﻤﺎ ﻗﺪ ﻳﺆﺩﻱ ﺇﻟﻰ ﺣﺪﻭﺙ ﺃﺧﻄﺎء ﺃﺛﻨﺎء‬ ‫)ﺍﻧﻈﺮ ﺍﻟﻘﺴﻢ ‪(2.1‬‬
‫ﻋﻤﻠﻴﺔﺗﺤﺪﻳﺪ ﺍﻟﻤﺮﺣﻠﺔ ﺍﻟﺘﻠﻘﺎﺉﻴﺔ‪ .‬ﻓﻲ ﻣﺜﻞ ﻫﺬﻩ‬ ‫ﺍﻟﺸﺮﻁﺍﻟﻤﺴﺒﻖ‪:‬ﻳﺘﻢ ﺗﺒﺪﻳﻞ ﻭﺿﻊ ﺍﻟﺘﺤﺪﻳﺪ ﺍﻟﺘﻠﻘﺎﺉﻲ‬
‫ﺍﻟﺤﺎﻻﺕ ‪،‬ﻧﻮﺻﻲ ﺑﺈﻳﻘﺎﻑ ﺗﺸﻐﻴﻞ ﺗﺤﺪﻳﺪ ﺍﻟﻤﺮﺣﻠﺔ‬ ‫ﺃﻭﺍﻟﺘﺤﺪﻳﺪ ﺍﻟﺘﻠﻘﺎﺉﻲ ﻟﻮﺿﻊ ﻣﺮﺍﺣﻞ ﻣﻜﺜﻒ ﻣﺘﺼﻞ‬
‫ﻭﺑﺮﻣﺠﺔﺍﻟﻘﻴﻢ ﺫﺍﺕ ﺍﻟﺼﻠﺔ ﻳﺪﻭﻳﺎً‪) .‬ﺍﻧﻈﺮ ﺍﻷﻗﺴﺎﻡ ‪5.5‬‬ ‫ﺇﻟﻰ"ﺗﺸﻐﻴﻞ"‪.‬‬
‫ﺇﻟﻰ‪(5.8‬‬

‫ﻳﺘﺤﻘﻖ‪ RM 9606‬ﻣﻦ ﺗﻴﺎﺭﺍﺕ ﺍﻟﻤﺮﺣﻠﺔ ﺍﻟﻤﺨﺰﻧﺔ ﻓﻲ‬


‫ﻓﺘﺮﺍﺕﺯﻣﻨﻴﺔ ﻣﺤﺪﺩﺓ ﺃﺛﻨﺎء ﺍﻟﺘﺸﻐﻴﻞ ﺍﻟﻌﺎﺩﻱ‪ .‬ﺇﺫﺍ‬
‫‪2.3‬ﺍﻹﻋﺪﺍﺩ ﺍﻟﺘﻠﻘﺎﺉﻲ ﻟﺘﺒﺪﻳﻞ ﺗﺄﺧﻴﺮ‬ ‫ﺃﺩﺭﻛﺖﺃﻥ ﻣﺮﺣﻠﺔ ﻣﻜﺜﻒ ﻗﺪ ﻓﺸﻠﺖ ‪ ،‬ﻓﺴﻴﺘﻢ ﺗﺠﺎﻫﻞ‬
‫ﺍﻟﻮﻗﺖ‬ ‫ﻫﺬﻩﺍﻟﻤﺮﺣﻠﺔ )ﺍﻟﻤﺮﺣﻠﺔ ﺑﺪﻭﻥ ﺳﻌﺔ( ﻓﻲ ﺍﻟﻌﻤﻠﻴﺎﺕ‬
‫ﺍﻟﻌﺎﺩﻳﺔﺍﻟﻤﺴﺘﻘﺒﻠﻴﺔ‪.‬‬
‫ﻣﻦﺃﺟﻞ ﺍﻟﺤﻔﺎﻅ ﻋﻠﻰ ﺗﺂﻛﻞ ﻣﻮﺻﻼﺕ ﺍﻟﻤﻜﺜﻒ ﺇﻟﻰ‬
‫ﺃﺩﻧﻰﺣﺪ ‪ ،‬ﻳﺘﻢ ﺇﻃﺎﻟﺔ ﺃﻭ ﺗﻘﺼﻴﺮ ﻭﻗﺖ ﺍﺳﺘﺠﺎﺑﺔ ﻣﺮﺣﻞ‬
‫ﺍﻟﺘﺤﻜﻢﺗﻠﻘﺎﺉﻴﺎً ﻭﻓﻘﺎً ﻟﺘﻜﺮﺍﺭ ﺗﻐﻴﻴﺮ ﺍﻟﺤﻤﻞ‪.‬‬ ‫ﻳﺘﻢﺗﺸﻐﻴﻞ ﺟﻤﻴﻊ ﺍﻟﻤﺮﺍﺣﻞ ﺍﻟﻔﺎﺷﻠﺔ ﻣﻦ ﻭﻗﺖ ﻵﺧﺮ‬
‫ﻣﻦﺃﺟﻞ ﺇﻋﺎﺩﺓ ﺍﻟﺘﺤﻘﻖ ﻣﻦ ﺍﻟﺴﻌﺔ‪ .‬ﺇﺫﺍ ﺗﻤﺖ ﺇﺿﺎﻓﺔ‬
‫ﻣﺮﺣﻠﺔﻣﻜﺜﻒ ﻻﺣﻘﺎً ‪ ،‬ﺃﻭ ﺗﻢ ﺍﺳﺘﺒﺪﺍﻝ ﺍﻟﺼﻤﺎﻣﺎﺕ‬
‫ﺍﻟﻤﻌﻴﺒﺔ ‪،‬ﻓﺈﻥ ‪ RM 9606‬ﻧﻔﺴﻪ ﻳﺤﺪﺩ ﺫﻟﻚ ﺑﻌﺪ ﻣﺮﻭﺭ‬
‫ﺑﻌﺾﺍﻟﻮﻗﺖ ﻭﻳﺘﻢ ﺇﻋﺎﺩﺓ ﺩﻣﺞ ﺍﻟﻤﺮﺣﻠﺔ ﻓﻲ ﺍﻟﺘﺸﻐﻴﻞ‬
‫‪2.4‬ﻗﻮﺓ ﺭﺩﻭﺩ ﺍﻟﻔﻌﻞ‬ ‫ﺍﻟﻌﺎﺩﻱ‪.‬ﻭﻣﻊ ﺫﻟﻚ ‪ ،‬ﻧﻮﺻﻲ ﺑﺄﻧﻪ ﺇﺫﺍ ﺗﻤﺖ ﺇﺿﺎﻓﺔ‬
‫ﻣﺮﺍﺣﻞﺍﻟﻤﻜﺜﻒ ﻓﻲ ﻭﻗﺖ ﻻﺣﻖ ‪ ،‬ﻓﺈﻥ ﺇﺟﺮﺍء ﺍﻹﻋﺪﺍﺩ‬
‫ﺗﻢﺗﺠﻬﻴﺰ ‪ RM 9606‬ﺑﺄﺭﺑﻌﺔ ﺗﺤﻜﻢ ﺭﺑﺎﻋﻲ‪ .‬ﻫﺬﺍ ﻳﻌﻨﻲ‬ ‫ﻳﺘﻜﺮﺭ)ﺍﻧﻈﺮ ﺍﻟﻘﺴﻢ ‪.(2.1‬‬
‫ﺃﻧﻪﺣﺘﻰ ﻋﻨﺪ ﺇﻋﺎﺩﺓ ﺗﻐﺬﻳﺔ ﺍﻟﻄﺎﻗﺔ ﺍﻟﻨﺸﻄﺔ ﺇﻟﻰ ﺍﻟﺘﻴﺎﺭ‬
‫ﺍﻟﻜﻬﺮﺑﺎﺉﻲ ‪،‬ﻓﺈﻥ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻳﻀﻤﻦ ﺗﻌﻮﻳﺾ‬
‫ﺍﻟﻘﻮﺓﺍﻟﺘﻔﺎﻋﻠﻴﺔ ﺍﻟﺘﻲ ﺗﻢ ﺳﺤﺒﻬﺎ ﻣﻦ ﺍﻟﺘﻴﺎﺭ ﺍﻟﻜﻬﺮﺑﺎﺉﻲ‪.‬‬
‫ﻓﻲﻫﺬﻩ ﺍﻟﺤﺎﻟﺔ ﻳﻀﻲء ﻣﺆﺷﺮ ‪" LED‬ﺍﻟﺘﺠﺪﻳﺪ"‪.‬‬

‫‪9‬‬
‫‪3.2‬ﺗﻮﺻﻴﻞ ﺍﻟﺠﻬﺪ‬ ‫‪.3‬ﺍﻟﺘﺜﺒﻴﺖ ﻭﺍﻻﺗﺼﺎﻝ‬
‫ﻳﻔﻀﻞﺗﻮﺻﻴﻞ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﺑﺎﻟﻨﻈﺎﻡ ﺛﻼﺛﻲ ﺍﻟﻄﻮﺭ‬
‫ﻳﺤﺪﺩﺍﻟﺘﺤﻜﻢ ﺍﻟﺘﻔﺎﻋﻠﻲ ﻓﻲ ﺍﻟﻘﺪﺭﺓ ‪ RM 9606‬ﺗﻠﻘﺎﺉﻴﺎً‬
‫ﻛﻤﺎﻫﻮ ﻣﻮﺿﺢ ﻓﻲ )ﺍﻟﺼﻔﺤﺔ ‪ .(11‬ﻟﻠﺤﻔﺎﻅ ﻋﻠﻰ‬
‫ﻣﻮﻗﻊﻣﺼﺎﺩﺭ ﺍﻟﺘﻴﺎﺭ ﻭﺍﻟﺠﻬﺪ )ﺍﻟﺪﻭﺭﺍﻥ ﺍﻟﺘﻠﻘﺎﺉﻲ ﻟﻠﻄﻮﺭ(‬
‫ﺗﺸﻐﻴﻞﻭﻇﻴﻔﺔ "ﺇﻧﺬﺍﺭ ﺍﻟﺠﻬﺪ ﺍﻟﺼﻔﺮﻱ" ‪ ،‬ﻳﺠﺐ‬
‫‪.‬ﻗﺪ ﻳﻜﻮﻥ ﻣﺘﺼﻼ ًﺇﻣﺎ ﺑﻤﺮﺣﻠﺘﻴﻦ )ﻃﻮﺭ ‪ /‬ﻃﻮﺭ( ﺃﻭ‬
‫ﺗﻮﺻﻴﻞﺟﻬﺪ ﺇﻣﺪﺍﺩ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻓﻲ ﻧﻔﺲ ﺍﻟﻤﺮﺣﻠﺔ‬
‫ﺑﻤﺮﺣﻠﺔﻭﺍﺣﺪﺓ ﻭﻣﺤﺎﻳﺪﺓ )ﻃﻮﺭ ‪ /‬ﻣﺤﺎﻳﺪ(‪ .‬ﻳﻤﻜﻦ ﺗﺮﻛﻴﺐ‬
‫ﻣﺜﻞﺟﻬﺪ ﺍﻟﻤﻮﺻﻞ‪.‬‬
‫ﺍﻟﻤﺤﻮﻝﺍﻟﺤﺎﻟﻲ ﻓﻲ ﺃﻱ ﻣﺮﺣﻠﺔ‪ .‬ﻳﺠﺐ ﺃﻥ ﻳﺘﻢ ﺗﻤﺮﻳﺮﻩ‬
‫ﺑﻮﺍﺳﻄﺔﻛﻞ ﻣﻦ ﺍﻟﻤﻜﺜﻒ ﻭﺍﻟﺘﻴﺎﺭ ﺍﻟﻤﺴﺘﻬﻠﻚ‪.‬‬

‫ﻳﺠﺐﺗﻮﺻﻴﻞ ﺟﻬﺪ ﺇﻣﺪﺍﺩ ‪ 230‬ﻓﻮﻟﺖ ﺑﻴﻦ ﺍﻷﻃﺮﺍﻑ‬


‫"‪ "N / L‬ﻭ "‪ ."230V‬ﻳﺠﺐ ﺗﻮﺻﻴﻞ ﺟﻬﺪ ﺇﻣﺪﺍﺩ ‪400‬‬
‫ﻓﻮﻟﺖﻓﻲ ﺍﻟﻤﺤﻄﺎﺕ ﺍﻟﻄﺮﻓﻴﺔ "‪ "N / L‬ﻭ "‪."400V‬‬
‫ﻣﻼﺣﻈﺔﻫﺎﻣﺔ‪:‬‬
‫ﺃﺛﻨﺎءﺃﻋﻤﺎﻝ ﺍﻟﺘﺮﻛﻴﺐ ﻭﺍﻟﺨﺪﻣﺔ ‪ ،‬ﻳﺠﺐ ﺃﻥ‬
‫ﻳﻈﻞﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﺧﺎﻟﻴﺎً ﻣﻦ ﺍﻟﺠﻬﺪ‪.‬‬
‫ﻣﻼﺣﻈﺔﻫﺎﻣﺔ‪:‬‬
‫ﺗﻢﺗﺼﻤﻴﻢ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻟﺠﻬﺪ ﺭﺉﻴﺴﻲ ‪230‬‬ ‫‪3.1‬ﺍﻟﺘﺜﺒﻴﺖ‬
‫ﻓﻮﻟﺖﺗﻴﺎﺭ ﻣﺘﺮﺩﺩ ﺃﻭ ‪ 400‬ﻓﻮﻟﺖ ﺗﻴﺎﺭ ﻣﺘﺮﺩﺩ )ﻃﻮﺭ‬
‫‪ /‬ﻣﺤﺎﻳﺪ ﺃﻭ ﻃﻮﺭ ‪ /‬ﻃﻮﺭ(‪.‬‬ ‫ﻣﺮﺣﻼﺕﺍﻟﺘﺤﻜﻢ ﺍﻟﻤﻮﺭﺩﺓ ﺑﺸﻜﻞ ﻓﺮﺩﻱ ﻣﺰﻭﺩﺓ‬
‫ﺑﻤﺴﺎﻣﻴﺮﺗﺜﺒﻴﺖ ﻣﻌﺰﻭﻟﺔ‪ .‬ﻳﻤﻜﻦ ﺍﺳﺘﺨﺪﺍﻡ ﻫﺬﻩ‬
‫ﺑﺎﻟﻨﺴﺒﺔﻟﻠﺠﻬﻮﺩ ﺍﻟﺘﻲ ﺗﺰﻳﺪ ﻋﻦ ‪ 400‬ﻓﻮﻟﺖ ﺃﻭ‬ ‫ﻟﺘﺮﻛﻴﺐﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻓﻲ ﺧﺰﺍﻧﺎﺕ ﺍﻟﻤﻔﺎﺗﻴﺢ‬
‫ﺗﺴﺎﻭﻳﻬﺎ ‪،‬ﻳﺠﺐ ﺍﺳﺘﺨﺪﺍﻡ ﻣﺤﻮﻝ ﺗﺤﻜﻢ ﻟﺘﺰﻭﻳﺪ‬ ‫ﺍﻟﻜﻬﺮﺑﺎﺉﻴﺔﻟﻤﻘﺼﻮﺭﺍﺕ ﺍﻟﺤﻤﺎﻳﺔ ﻣﻦ ﺍﻟﺪﺭﺟﺔ ﺍﻟﺜﺎﻧﻴﺔ‪.‬‬
‫ﻭﺣﺪﺓﺍﻟﺘﺤﻜﻢ‪.‬‬ ‫ﻋﻼﻭﺓﻋﻠﻰ ﺫﻟﻚ ‪ ،‬ﻳﺘﻢ ﺗﻮﻓﻴﺮ ﺣﻠﻘﺔ ﻣﺎﻧﻌﺔ ﻟﻠﺘﺴﺮﺏ ‪،‬‬
‫ﻻﻳﺠﻮﺯ ﺍﺳﺘﺨﺪﺍﻡ ﻃﺮﻓﻲ ﺍﻟﺘﻮﺻﻴﻞ "‪230‬‬ ‫ﻭﺍﻟﺘﻲﻳﺠﺐ ﺍﺳﺘﺨﺪﺍﻣﻬﺎ ﻋﻨﺪ ﺗﺜﺒﻴﺖ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ‬
‫ﻓﻮﻟﺖ" ﻭ "‪ 400‬ﻓﻮﻟﺖ" ﻓﻲ ﻧﻔﺲ ﺍﻟﻮﻗﺖ‪.‬‬ ‫ﻓﻲﺧﺰﺍﻧﺎﺕ ﺍﻟﻤﻔﺎﺗﻴﺢ ﻭﺍﻟﻤﻘﺼﻮﺭﺍﺕ ﻣﻦ ﻓﺉﺔ ﺍﻟﺤﻤﺎﻳﺔ‬
‫‪.IP54‬‬
‫ﻳﺠﺐﺃﻥ ﻳﻜﻮﻥ ﺗﻮﺻﻴﻞ ﺟﻬﺪ ﺍﻹﻣﺪﺍﺩ‬
‫ﻣﺼﻬﺮﺍًﺧﺎﺭﺟﻴﺎً‬ ‫ﺗﺴﻤﺢﺍﻟﻮﺻﻼﺕ ﺍﻟﻄﺮﻓﻴﺔ ﺍﻟﻤﺮﻛﺒﺔ ﻣﺴﺒﻘﺎً ﺑﺎﻟﺘﺜﺒﻴﺖ‬
‫ﻣﻊ‪ 4A‬ﻛﺤﺪ ﺃﻗﺼﻰ‪.‬‬ ‫ﺍﻟﺴﺮﻳﻊﻭﺍﻟﺴﻬﻞ‪ .‬ﻳﺘﻢ ﺗﻮﺻﻴﻞ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻛﻬﺮﺑﺎﺉﻴﺎً‬
‫ﻣﻦﺧﻼﻝ ﻣﺤﻄﺔ ﺗﻮﺻﻴﻞ ﻣﺘﻌﺪﺩﺓ ﻣﺰﻭﺩﺓ ﺑﺎﻟﻤﺮﺣﻞ‪.‬‬

‫‪10‬‬
‫ﺍﻟﺸﻜﻞ‪:3‬ﻣﺨﻄﻂ ﺍﻟﺮﺳﻢ ﺍﻟﺒﻴﺎﻧﻲ‬

‫ﻳﻼﺣﻆ‪:‬‬ ‫‪3.3‬ﺍﺗﺼﺎﻝ ﺍﻟﻤﺤﻮﻝ ﺍﻟﺤﺎﻟﻲ‬


‫ﺑﻌﺪﺍﻟﺘﻮﺻﻴﻞ ‪ ،‬ﻗﺪ ﻳﺘﻌﻴﻦ ﺇﺯﺍﻟﺔ ﺟﺴﺮ ﺍﻟﺪﺍﺉﺮﺓ‬ ‫ﻳﺘﻢﺗﻮﺻﻴﻞ ﻣﺨﺮﺟﺎﺕ ‪ S1‬ﻭ ‪ S2‬ﻟﻠﻤﺤﻮﻝ ﺍﻟﺤﺎﻟﻲ‬
‫ﺍﻟﻘﺼﻴﺮﺓﻣﻦ ﺍﻟﻤﺤﻮﻝ ﺍﻟﺤﺎﻟﻲ‪.‬‬ ‫ﺑﺎﻟﻤﻄﺮﺍﻑ‪ S1‬ﻭ ‪ S2‬ﻟﻤﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ‪ .‬ﻣﻦ ﺃﺟﻞ ﺍﻟﺤﻔﺎﻅ‬
‫ﻋﻠﻰﺍﻟﺤﻤﻞ ﻋﻠﻰ ﺍﻟﻤﺤﻮﻝ ﺍﻟﺤﺎﻟﻲ ﻋﻨﺪ ﺃﺩﻧﻰ ﻣﺴﺘﻮﻯ‬
‫ﻣﻤﻜﻦ ‪،‬ﻳﺠﺐ ﺃﻥ ﻳﻜﻮﻥ ﻟﺨﻄﻮﻁ ﺍﻹﻣﺪﺍﺩ ﻣﺴﺎﺣﺔ‬
‫‪3.4‬ﺍﺗﺼﺎﻻﺕ ﺍﻟﺘﻨﺒﻴﻪ‬ ‫ﻣﻘﻄﻊﻋﺮﺿﻲ ‪ 2.5‬ﻣﻢ‪.²‬‬
‫ﻳﻤﻜﻦﺍﻟﻮﺻﻮﻝ ﺇﻟﻰ ﺍﺗﺼﺎﻝ ﺇﺷﺎﺭﺓ ﺇﻧﺬﺍﺭ ﻏﻴﺮ ﻣﻤﻜﻦ‬
‫ﻋﻠﻰﺍﻟﻤﺤﻄﺎﺕ ﺍﻟﻄﺮﻓﻴﺔ "ﺃ" ﻭ "ﺏ"‪ .‬ﻳﺘﻢ ﺇﻏﻼﻕ ﺟﻬﺔ‬
‫ﺍﻻﺗﺼﺎﻝﻓﻲ ﺣﺎﻟﺔ ﻋﺪﻡ ﻭﺟﻮﺩ ﺟﻬﺪ ﺭﺉﻴﺴﻲ ﻣﻄﺒﻖ‬
‫ﻋﻠﻰﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﺃﻭ ﻋﻨﺪ ﺇﺭﺳﺎﻝ ﺇﺷﺎﺭﺓ ﺇﻧﺬﺍﺭ )ﺍﻟﻘﺴﻢ‬ ‫ﺍﻻﻧﺘﺒﺎﻩ‪:‬‬
‫‪(6.3‬‬ ‫ﻳﺠﺐﺃﻻ ﻳﺘﺠﺎﻭﺯ ﺍﻟﺘﻴﺎﺭ ﺍﻟﻤﻘﻨﻦ ﻓﻲ ﻣﺴﺎﺭ‬
‫ﺍﻟﻤﺤﻮﻝﺍﻟﺤﺎﻟﻲ ‪ 5‬ﺃﻣﺒﻴﺮ‪.‬‬

‫‪11‬‬
‫‪3.6‬ﺗﻌﻠﻴﻤﺎﺕ ﺇﺿﺎﻓﻴﺔ‬ ‫ﻋﻨﺪﻣﺎﺗﻜﻮﻥ ﻫﻨﺎﻙ ﺇﺷﺎﺭﺓ ﺇﻧﺬﺍﺭ ‪ ،‬ﻳﻀﻲء "ﺇﻧﺬﺍﺭ" ‪LED‬‬
‫ﻭﻳﺒﺪﺃﻣﺆﺷﺮ ‪ LED‬ﺫﻱ ﺍﻟﺼﻠﺔ ﻓﻲ ﺍﻟﻮﻣﻴﺾ ﻋﻠﻰ ﻣﺮﺣﻞ‬
‫ﻟﻢﻳﺘﻢ ﺍﻻﻧﺘﻬﺎء ﻣﻦ ﺗﺮﻛﻴﺐ ﻭﺗﻮﺻﻴﻞ ‪ RM 9606‬ﺇﻻ‬
‫ﺍﻟﺘﺤﻜﻢ‪.‬‬
‫ﺑﻌﺪﺃﻥ ﻳﺘﻢ ﺗﺜﺒﻴﺘﻪ ﻭﺗﻮﺻﻴﻠﻪ ﻭﻓﻘﺎً ﻟﻬﺬﻩ ﺍﻟﺘﻌﻠﻴﻤﺎﺕ‪.‬‬

‫ﻣﻼﺣﻈﺔﻫﺎﻣﺔ‪:‬‬
‫ﻳﺠﺐﺃﻻ ﻳﻜﻮﻥ ﻣﻦ ﺍﻟﻤﻤﻜﻦ ﻟﻤﺲ ﺍﻟﺠﻬﺪ‬
‫ﻣﻼﺣﻈﺔﻫﺎﻣﺔ‪:‬‬ ‫ﺍﻟﻤﻄﺒﻖﻋﻨﺪ ﺍﺗﺼﺎﻝ ﺍﻹﻧﺬﺍﺭ‪ .‬ﺇﺫﺍ ﺗﻌﺬﺭ ﺗﺤﻘﻴﻖ‬
‫ﺫﻟﻚ ‪،‬ﻓﻴﺠﺐ ﺗﺄﺭﻳﺾ ﺍﻟﺠﻬﺪ ‪ ،‬ﺣﺘﻰ ﻟﻮ ﻛﺎﻥ‬
‫ﻗﺒﻞﺑﺪء ﺗﺸﻐﻴﻞ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ‪ ،‬ﻳﺠﺐ ﺍﻟﺘﺄﻛﺪ‬
‫ﺟﻬﺪﺍًﻭﻗﺎﺉﻴﺎً ﺻﻐﻴﺮﺍً ﻓﻘﻂ‪.‬‬
‫ﻣﻦﺃﻧﻪ ﻻ ﻳﻤﻜﻦ ﻟﻤﺲ ﺃﻃﺮﺍﻑ ﺍﻟﺘﻮﺻﻴﻞ )ﻋﻠﻰ‬
‫ﺳﺒﻴﻞﺍﻟﻤﺜﺎﻝ ﻋﻦ ﻃﺮﻳﻖ ﺑﺎﺏ ﺃﻭ ﻏﻄﺎء ﻣﻘﻔﻞ(‪.‬‬
‫ﺍﻟﺤﺪﺍﻷﻗﺼﻰ ﻟﻠﺤﻤﻞ ﻟﺠﻬﺔ ﺍﺗﺼﺎﻝ ﺍﻟﺘﻨﺒﻴﻪ ﻫﻮ‬
‫‪250‬ﻓﻮﻟﺖ ﺗﻴﺎﺭ ﻣﺘﺮﺩﺩ ﻭ ‪ 3‬ﺃﻣﺒﻴﺮ‪.‬‬

‫ﻳﺠﺐﺃﻥ ﻳﻈﻞ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﺧﺎﻟﻴﺎً ﻣﻦ ﺍﻟﺠﻬﺪ‬ ‫‪3.5‬ﺍﻟﺘﺤﻜﻢ ﻓﻲ ﺟﻬﺎﺕ ﺍﻻﺗﺼﺎﻝ‬


‫ﺃﺛﻨﺎءﺃﻋﻤﺎﻝ ﺍﻷﺳﻼﻙ ﻭﺍﻟﺘﺮﻛﻴﺐ‪.‬‬
‫ﻳﺠﺐﺗﻮﺻﻴﻞ ﺟﻬﺪ ﺍﻟﺘﺤﻜﻢ ﻟﻠﻤﻮﺻﻼﺕ ﺑﺄﻃﺮﺍﻑ‬
‫ﺍﻟﺘﻮﺻﻴﻞ"‪ "PI‬ﻭ "‪ ."PII‬ﻫﺬﻩ ﺍﻟﺪﻭﺍﺉﺮ ﺧﺎﻟﻴﺔ ﻣﻦ‬
‫ﺍﻹﻣﻜﺎﻧﺎﺕ‪.‬‬

‫ﻣﻼﺣﻈﺔﻫﺎﻣﺔ‪:‬‬
‫ﻣﻦﺃﺟﻞ ﻋﺪﻡ ﺍﻟﺘﺤﻤﻴﻞ ﺍﻟﺰﺍﺉﺪ ﻟﺠﻬﺎﺕ‬
‫ﺍﻻﺗﺼﺎﻝ ‪،‬ﻳﺠﺐ ﺃﻻ ﻳﺘﺠﺎﻭﺯ ﻣﺠﻤﻮﻉ ﺍﻟﺘﻴﺎﺭﺍﺕ‬
‫ﺍﻟﻘﺎﺑﻀﺔﻟﺠﻤﻴﻊ ﻣﻠﻔﺎﺕ ﺍﻟﻤﻮﺻﻞ ﺍﻟﻤﺘﺼﻠﺔ‬
‫ﻗﻴﻤﺔ‪ 5‬ﺃﻣﺒﻴﺮ‪ .‬ﺍﻟﺤﺪ ﺍﻷﻗﺼﻰ‪ .‬ﺣﻤﻞ ﺍﺗﺼﺎﻻﺕ‬
‫ﺍﻟﺘﺒﺪﻳﻞﻫﻮ ‪ 380‬ﻓﻮﻟﺖ ﺗﻴﺎﺭ ﻣﺘﺮﺩﺩ‪.‬‬

‫ﻣﻦﺃﺟﻞ ﺍﻟﺤﻔﺎﻅ ﻋﻠﻰ ﻭﻇﻴﻔﺔ ﻣﺮﺍﻗﺒﺔ ﺍﻧﺨﻔﺎﺽ‬


‫ﺍﻟﺠﻬﺪ ‪،‬ﻣﻦ ﺍﻟﻀﺮﻭﺭﻱ ﻟﻠﻐﺎﻳﺔ ﺍﻟﺘﺄﻛﺪ ﻣﻦ ﺃﻥ ﺟﻬﺪ‬
‫ﺍﻟﺘﺤﻜﻢﻟﻠﻤﻮﺻﻼﺕ ﻓﻲ ﻧﻔﺲ ﺍﻟﻤﺮﺣﻠﺔ ﻣﺜﻞ ﺇﻣﺪﺍﺩ‬
‫ﻣﺮﺣﻞﺍﻟﺘﺤﻜﻢ‪.‬‬

‫‪12‬‬
‫ﻣﻦﺍﻟﻤﻤﻜﻦ ﺃﻳﻀﺎً ﺇﻳﻘﺎﻑ ﻋﻤﻠﻴﺔ ﺗﺤﺪﻳﺪ ﺍﻟﻬﻮﻳﺔ ﻋﻦ‬ ‫‪.4‬ﺍﻟﺘﻜﻠﻴﻒ‬
‫ﻃﺮﻳﻖﺇﻳﻘﺎﻑ ﺗﺸﻐﻴﻞ ﺍﻻﺗﺼﺎﻝ ﺍﻟﺘﻠﻘﺎﺉﻲ ﻭﻣﺮﺣﻠﺔ‬
‫ﺗﺤﺪﻳﺪﺍﺕﺍﻟﺘﻴﺎﺭ‪ .‬ﻳﺤﺪﺙ ﻫﺬﺍ ﻓﻲ ﺍﻟﻮﺿﻊ ﺍﻟﻤﺤﺪﺩ ﻭﻓﻲ‬ ‫ﺑﻌﺪﺗﺜﺒﻴﺖ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻛﻤﺎ ﻫﻮ ﻣﻮﺿﺢ ﻓﻲ ﺍﻟﻘﺴﻢ‬
‫ﻧﻔﺲﺍﻟﻮﻗﺖ ﻣﻦ ﺍﻟﻀﺮﻭﺭﻱ ﺑﺮﻣﺠﺔ ﻣﻌﻠﻤﺎﺕ ﺍﻻﺗﺼﺎﻝ‬ ‫‪، 3‬ﻳﻤﻜﻦ ﺗﺸﻐﻴﻞ ﺍﻟﻤﺮﺣﻞ‪.‬‬
‫ﻭﺍﻟﻤﺮﺣﻠﺔﻳﺪﻭﻳﺎً )ﺍﻧﻈﺮ ﺍﻟﻘﺴﻢ ‪.(5‬‬

‫‪4.1‬ﺍﻟﺘﺸﻐﻴﻞ ﺍﻷﻭﻝ‬
‫ﺑﻌﺪﻋﻤﻠﻴﺔ ﺍﻟﺘﺤﺪﻳﺪ ‪ ،‬ﻳﻈﻬﺮ ﻋﺎﻣﻞ ﺍﻟﻄﺎﻗﺔ ﺍﻟﻔﻌﻠﻲ ﻋﻠﻰ‬ ‫ﻋﻨﺪﻣﺎﻳﺘﻢ ﺗﺸﻐﻴﻞ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻷﻭﻝ ﻣﺮﺓ ‪ ،‬ﻓﺈﻧﻪ‬
‫ﺍﻟﺸﺎﺷﺔﻭﻳﺒﺪﺃ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻓﻲ ﺍﻟﻌﻤﻞ‪.‬‬ ‫ﻳﺤﺎﻭﻝﺗﺤﺪﻳﺪ ﻭﺿﻊ ﺍﻻﺗﺼﺎﻝ ﻭﺣﺠﻢ ﺍﻟﻤﺮﺍﺣﻞ‪ .‬ﻳﻈﻬﺮ‬
‫ﻋﻠﻰﺍﻟﺸﺎﺷﺔ "‪ "---‬ﻭﺑﻌﺪ ﻭﻗﺖ ﺗﻔﺮﻳﻎ ﻟﻠﻤﻜﺜﻔﺎﺕ ﻳﺘﻢ‬
‫ﺇﺫﺍﻛﺎﻥ ﻋﺎﻣﻞ ﺍﻟﻘﺪﺭﺓ ﺍﻟﻤﻮﺿﺢ ﻻ ﻳﺘﻄﺎﺑﻖ ﻣﻊ ﻋﺎﻣﻞ‬ ‫ﺗﺸﻐﻴﻞﻭﺇﻳﻘﺎﻑ ﺍﻟﻤﺮﺍﺣﻞ ﻣﺮﺓ ﺗﻠﻮ ﺍﻷﺧﺮﻯ ﻭﺍﺣﺪﺓ ﺗﻠﻮ‬
‫ﺍﻟﻘﺪﺭﺓﺍﻟﺤﻘﻴﻘﻲ ‪ ،‬ﻓﻴﺠﺐ ﺗﻜﺮﺍﺭ ﻋﻤﻠﻴﺔ ﺍﻟﺘﺤﺪﻳﺪ‪ .‬ﻳﻤﻜﻦ‬ ‫ﺍﻷﺧﺮﻯ‪.‬ﻳﻤﻜﻦ ﺃﻥ ﺗﺴﺘﻐﺮﻕ ﻫﺬﻩ ﺍﻟﻌﻤﻠﻴﺔ ﻣﺎ ﻳﺼﻞ ﺇﻟﻰ‬
‫ﺍﻟﻘﻴﺎﻡﺑﺬﻟﻚ ﻋﻦ ﻃﺮﻳﻖ ﺍﻟﻀﻐﻂ ﻋﻠﻰ ﺍﻷﺯﺭﺍﺭ "‪ "+‬ﻭ "‪"-‬‬ ‫‪15‬ﺩﻗﻴﻘﺔ‪.‬‬
‫ﻭ"ﺗﻌﻴﻴﻦ" ﻓﻲ ﻭﻗﺖ ﻭﺍﺣﺪ ﻟﻤﺪﺓ ‪ 8‬ﺛﻮﺍﻥ ٍﻋﻠﻰ ﺍﻷﻗﻞ‪.‬‬

‫‪4.2‬ﺗﺠﺪﻳﺪ ﺍﻟﺘﻜﻠﻴﻒ‬ ‫ﺍﻻﻧﺘﺒﺎﻩ‪:‬‬


‫ﺑﻌﺪﻓﺸﻞ ﺍﻟﺘﻴﺎﺭ ﺍﻟﻜﻬﺮﺑﺎﺉﻲ ‪ ،‬ﻳﺒﺪﺃ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻋﻠﻰ‬ ‫ﺇﺫﺍﻛﺎﻥ ‪ RM 9606‬ﻻ ﻳﻌﻤﻞ ﻛﻤﺎ ﻫﻮ ﻣﻮﺿﺢ‬
‫ﺍﻟﻔﻮﺭﺑﺮﻧﺎﻣﺞ ﺍﻟﺘﺤﻜﻢ ﺍﻟﻌﺎﺩﻱ ﻣﺮﺓ ﺃﺧﺮﻯ‪ .‬ﻳﺘﻢ ﺗﺨﺰﻳﻦ‬ ‫ﺃﻋﻼﻩ ‪،‬ﻓﻘﻢ ﺑﺈﺯﺍﻟﺔ ﻣﺼﺪﺭ ﺍﻟﺠﻬﺪ ﻭﺗﺤﻘﻖ ﻣﻦ‬
‫ﺍﻟﺒﻴﺎﻧﺎﺕﺍﻟﺘﻲ ﺗﻢ ﺗﺤﺪﻳﺪﻫﺎ ﺃﺛﻨﺎء ﺍﻟﺘﺸﻐﻴﻞ ﻷﻭﻝ ﻣﺮﺓ‬ ‫ﺍﻟﺘﺮﻛﻴﺐ‪.‬‬
‫ﻓﻲﺫﺍﻛﺮﺓ ﻏﻴﺮ ﻣﺘﻄﺎﻳﺮﺓ‪.‬‬ ‫ﺇﺫﺍﻟﻢ ﻳﺘﻢ ﺍﻻﻧﺘﻬﺎء ﻣﻦ ﻋﻤﻠﻴﺔ ﺗﺤﺪﻳﺪ ﺍﻟﻬﻮﻳﺔ ﻓﻲ‬
‫ﻏﻀﻮﻥ‪ 15‬ﺩﻗﻴﻘﺔ ‪ ،‬ﻓﻤﻦ ﺍﻟﻤﺤﺘﻤﻞ ﺃﻥ ﻳﻜﻮﻥ ﻫﻨﺎﻙ‬
‫ﺧﻄﺄ‪).‬ﺍﻧﻈﺮ ﺍﻟﻘﺴﻢ ‪ ، 8‬ﺍﻟﺼﻔﺤﺔ ‪(35‬‬
‫ﺑﺎﻟﻀﻐﻂﻋﻠﻰ ﺍﻷﺯﺭﺍﺭ "‪ "+‬ﻭ "‪ "-‬ﻭ "ﺿﺒﻂ" ﻓﻲ ﻭﻗﺖ‬ ‫ﻳﻼﺣﻆ‪:‬‬
‫ﻭﺍﺣﺪﻟﻤﺪﺓ ‪ 8‬ﺛﻮﺍﻥ ٍﻋﻠﻰ ﺍﻷﻗﻞ ‪ ،‬ﻳﺘﻢ ﻣﺴﺢ ﻫﺬﻩ‬ ‫ﻟﻜﻲﻳﺘﻤﻜﻦ ﺍﻟﻤﺮﺣﻞ ﻣﻦ ﺗﺤﺪﻳﺪ ﻭﺿﻊ‬
‫ﺍﻟﺒﻴﺎﻧﺎﺕﻣﻦ ﺍﻟﺬﺍﻛﺮﺓ ﻭﻳﺒﺪﺃ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻣﺮﺓ ﺃﺧﺮﻯ‬
‫ﺍﻻﺗﺼﺎﻝ ‪،‬ﻳﺠﺐ ﺗﺸﻐﻴﻞ ﻣﺮﺣﻠﺔ ﻣﻜﺜﻒ ﻭﺍﺣﺪﺓ‬
‫ﻓﻲﺗﺤﺪﻳﺪ ﻭﺿﻊ ﺍﻻﺗﺼﺎﻝ ﻭﺣﺠﻢ ﺍﻟﻤﺮﺍﺣﻞ‪.‬‬
‫ﻋﻠﻰﺍﻷﻗﻞ‪.‬‬

‫ﻣﻦﺍﻟﻤﻔﺘﺮﺽ ﺃﻥ ﺍﻻﺗﺼﺎﻝ ﺍﻟﺘﻠﻘﺎﺉﻲ ﻭﺗﺤﺪﻳﺪ ﺍﻟﻤﺮﺣﻠﺔ‬ ‫ﺭﺑﻤﺎﺗﻢ ﺍﺳﺘﺨﺪﺍﻡ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﺑﺎﻟﻔﻌﻞ ﻣﻦ ﻗﺒﻞ‬
‫ﺍﻟﺤﺎﻟﻴﺔﻗﻴﺪ ﺍﻟﺘﺸﻐﻴﻞ )ﺍﻧﻈﺮ ﺍﻟﻘﺴﻢ ‪.(5‬‬ ‫ﻭﻳﻌﻤﻞﻛﻤﺎ ﻫﻮ ﻣﻮﺿﺢ ﻓﻲ ﺍﻟﻘﺴﻢ ‪.4.2‬‬

‫‪13‬‬
‫‪.5‬ﺍﻟﺒﺮﻣﺠﺔ )ﻣﺠﻤﻮﻋﺔ(‬
‫• ﺗﻈﻬﺮﺍﻟﻘﻴﻤﺔ ﺍﻟﻔﻌﻠﻴﺔ ﻋﻠﻰ ﺍﻟﺸﺎﺷﺔ ﻋﻨﺪ ﺍﻟﻀﻐﻂ‬ ‫ﻣﻦﺃﺟﻞ ﺍﻟﺴﻤﺎﺡ ﺑﺄﻭﺳﻊ ﺍﺳﺘﺨﺪﺍﻡ ﻣﻤﻜﻦ ﻟﻤﺮﺣﻞ‬
‫ﻋﻠﻰ"‪ "man / set‬ﻣﺮﺓ ﺃﺧﺮﻯ‪.‬‬ ‫ﺍﻟﺘﺤﻜﻢ ‪،‬ﺗﺘﻮﻓﺮ ﺇﻋﺪﺍﺩﺍﺕ ﻣﺘﻌﺪﺩﺓ‪ .‬ﻟﺘﺒﺴﻴﻂ ﺍﻷﻣﻮﺭ ‪،‬‬
‫• ﺑﺎﻟﻀﻐﻂﻋﻠﻰ ﺯﺭ "‪ "+‬ﺃﻭ "‪ "-‬ﻳﻤﻜﻦ ﺗﺤﻘﻴﻖ ﺍﻹﻋﺪﺍﺩ‬ ‫ﻳﺘﻢﺗﻌﻴﻴﻦ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻋﻠﻰ ﺍﻟﻘﻴﻢ ﺍﻟﻘﻴﺎﺳﻴﺔ ﻓﻲ‬
‫ﺍﻷﻋﻠﻰﺃﻭ ﺍﻷﺩﻧﻰ ﺍﻟﺘﺎﻟﻲ‪ .‬ﻳﻜﻮﻥ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻓﻲ‬ ‫ﻣﺼﻨﻌﻨﺎﻗﺒﻞ ﺍﻟﺘﺴﻠﻴﻢ‪.‬‬
‫ﻭﺿﻊﺍﻟﻘﺮﺍءﺓ ﻓﻘﻂ ﺇﺫﺍ ﻟﻢ ﻳﻜﻦ ﺫﻟﻚ ﻣﻤﻜﻨﺎً‪.‬‬
‫)ﺍﻧﻈﺮ ﺍﻟﺠﺪﻭﻝ ‪ ، 1‬ﺍﻟﺼﻔﺤﺎﺕ ‪ 15‬ﺇﻟﻰ ‪(17‬‬
‫ﻟﻠﻮﺻﻮﻝﺇﻟﻰ ﺍﻟﻮﺿﻊ ﺍﻟﻤﺤﺪﺩ ﻣﺮﺓ ﺃﺧﺮﻯ ‪ ،‬ﻳﺠﺐ‬
‫ﻓﺼﻞﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻋﻦ ﻣﺼﺪﺭﻩ ﻟﻔﺘﺮﺓ ﻗﺼﻴﺮﺓ‬ ‫ﻳﺤﺘﺎﺝﺍﻟﻤﺴﺘﺨﺪﻡ ﻓﻘﻂ ﺇﻟﻰ ﺗﻐﻴﻴﺮ ﻋﺎﻣﻞ ﺍﻟﻄﺎﻗﺔ‬
‫ﻣﻦﺍﻟﻮﻗﺖ‪.‬‬ ‫ﺍﻟﻤﺴﺘﻬﺪﻑﺃﻭ ﺑﻌﺾ ﺍﻟﻘﻴﻢ ﻟﺘﻨﺎﺳﺐ ﻣﺘﻄﻠﺒﺎﺗﻪ‬
‫ﺍﻟﺨﺎﺻﺔ‪.‬ﻛﺤﻤﺎﻳﺔ ﺿﺪ ﺇﻋﺎﺩﺓ ﺍﻟﺒﺮﻣﺠﺔ ﻏﻴﺮ ﺍﻟﻤﻘﺼﻮﺩﺓ ‪،‬‬
‫ﻻﻳﻤﻜﻦ ﺍﺳﺘﺪﻋﺎء ﻭﺿﻊ ﺍﻟﻀﺒﻂ )ﻭﺿﻊ ﺍﻟﺒﺮﻣﺠﺔ( ﺇﻻ‬
‫• ﺍﺿﻐﻂﻋﻠﻰ ﺯﺭ "‪ "man / set‬ﺑﺸﻜﻞ ﻣﺘﻜﺮﺭ ؛ ﺗﻈﻬﺮ‬
‫ﻓﻲﻏﻀﻮﻥ ‪ 5‬ﺩﻗﺎﺉﻖ ﺑﻌﺪ ﺗﻄﺒﻴﻖ ﺟﻬﺪ ﺍﻟﺘﺸﻐﻴﻞ‪ .‬ﺑﻌﺪ‬
‫ﺃﺭﻗﺎﻡﺍﻟﻮﺿﻊ ﻣﺘﺒﻮﻋﺔ ﺑﺎﻟﻘﻴﻤﺔ ﺍﻟﻤﺒﺮﻣﺠﺔ )ﺍﻧﻈﺮ‬
‫ﻫﺬﻩﺍﻟﻔﺘﺮﺓ ‪ ،‬ﻳﻤﻜﻦ ﻗﺮﺍءﺓ ﺍﻟﻘﻴﻢ ﻓﻘﻂ )ﻭﺿﻊ ﺍﻟﻘﺮﺍءﺓ‬
‫ﺍﻟﺠﺪﻭﻝ‪.(1‬‬
‫ﻓﻘﻂ(‪ .‬ﺇﺫﺍ ﺗﻢ ﺗﻨﺸﻴﻂ ﻭﺿﻊ ﺍﻟﻀﺒﻂ ﺧﻼﻝ ﻫﺬﻩ‬
‫• ﺇﺫﺍﺗﻢ ﺍﻟﻀﻐﻂ ﻋﻠﻰ "‪ "+‬ﻣﺮﺓ ﺃﺧﺮﻯ ﺑﻌﺪ ﻇﻬﻮﺭ ﺭﻗﻢ‬ ‫ﺍﻟﺪﻗﺎﺉﻖﺍﻟﺨﻤﺲ ‪ ،‬ﻓﺴﻴﻈﻞ ﻣﺘﺎﺣﺎً ﻟﻤﺪﺓ ﺳﺎﻋﺔ‬
‫ﺍﻟﻮﺿﻊ"‪ "-24-‬ﻋﻠﻰ ﺍﻟﺸﺎﺷﺔ ‪ ،‬ﺃﻭ ﺇﺫﺍ ﺗﻢ ﺍﻟﻀﻐﻂ‬ ‫ﻭﺍﺣﺪﺓ‪.‬ﻣﻦ ﺃﺟﻞ ﺍﻟﻮﺻﻮﻝ ﺇﻟﻰ ﺍﻟﻮﺿﻊ ﺍﻟﻤﺤﺪﺩ ﻣﺮﺓ‬
‫ﻋﻠﻰ"‪ "-‬ﻣﺮﺓ ﺃﺧﺮﻯ ﺑﻌﺪ ﻇﻬﻮﺭ ﺭﻗﻢ ﺍﻟﻮﺿﻊ "‪"-01-‬‬ ‫ﺃﺧﺮﻯﺑﻌﺪ ﻫﺬﻩ ﺍﻟﻔﺘﺮﺓ ‪ ،‬ﻣﻦ ﺍﻟﻀﺮﻭﺭﻱ ﻓﺼﻞ ﻣﺮﺣﻞ‬
‫ﻋﻠﻰﺍﻟﺸﺎﺷﺔ ‪ ،‬ﻓﺴﺘﻈﻬﺮ ﺍﻟﺸﺎﺷﺔ "ﺇﻧﻬﺎء" "‪.‬‬ ‫ﺍﻟﺘﺤﻜﻢﻋﻦ ﻣﺼﺪﺭﻩ ﻟﻔﺘﺮﺓ ﻗﺼﻴﺮﺓ ﻣﻦ ﺍﻟﻮﻗﺖ‪.‬‬

‫• ﺑﺘﺄﻛﻴﺪﻋﺮﺽ "ﺇﻧﻬﺎء" ﺑﺎﻟﻀﻐﻂ ﻋﻠﻰ ﺯﺭ "‪/ Set‬‬


‫‪ ، "man‬ﻳﻔﺘﺮﺽ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﺍﻟﺘﺸﻐﻴﻞ ﺍﻟﻌﺎﺩﻱ ؛‬
‫ﺛﻢﻳﺘﻢ ﺗﺨﺰﻳﻦ ﺍﻟﻘﻴﻢ ﺍﻟﻤﺤﺪﺩﺓ ﻣﺴﺒﻘﺎً ﺑﺸﻜﻞ ﺩﺍﺉﻢ‬ ‫ﻳﻜﻮﻥﺇﺟﺮﺍء ﻓﺤﺺ ﺃﻭ ﺇﻋﺎﺩﺓ ﺑﺮﻣﺠﺔ ﺍﻟﻘﻴﻢ ﺍﻟﻤﺤﺪﺩﺓ ﻛﻤﺎ‬
‫ﻓﻲﺫﺍﻛﺮﺓ ﻏﻴﺮ ﻣﺘﻄﺎﻳﺮﺓ‪.‬‬ ‫ﻳﻠﻲ‪:‬‬

‫ﻳﻼﺣﻆ‪:‬‬
‫ﺃﺛﻨﺎء"ﻭﺿﻊ ﺍﻟﻀﺒﻂ" ‪ ،‬ﻻ ﻳﺘﻢ ﺗﻐﻴﻴﺮ ﺃﻱ ﻣﻦ ﻣﺮﺍﺣﻞ‬
‫ﺍﻟﻤﻜﺜﻒﻭﻻ ﻳﻮﺟﺪ ﺗﺒﺪﻳﻞ ﻟﺠﻬﺔ ﺍﺗﺼﺎﻝ ﺍﻹﻧﺬﺍﺭ‪.‬‬ ‫• ﺍﺿﻐﻂﻋﻠﻰ ﺯﺭ "‪ "man / set‬ﻟﻤﺪﺓ ﺛﻤﺎﻧﻲ ﺛﻮﺍﻥ‬
‫ﻋﻠﻰﺍﻷﻗﻞ ﻟﻠﺘﺒﺪﻳﻞ ﺇﻟﻰ ﺍﻟﻮﺿﻊ ﺍﻟﻤﺤﺪﺩ‪ .‬ﺛﻢ ﻳﻈﻬﺮ‬
‫ﻋﻠﻰﺍﻟﺸﺎﺷﺔ "‪ ."-01-‬ﻳﺘﻮﺍﻓﻖ ﻫﺬﺍ ﺍﻟﺮﻗﻢ ﻣﻊ ﺍﻟﻤﺘﻐﻴﺮ‬
‫ﺍﻷﻭﻝﺍﻟﻤﻌﺮﻭﺽ ﺃﻭ ﻳﻤﻜﻦ ﺗﻐﻴﻴﺮﻩ ﺑﺎﻟﺘﺴﻠﺴﻞ ﺍﻟﺘﺎﻟﻲ )‬
‫ﺍﻧﻈﺮﺍﻟﺠﺪﻭﻝ ‪.(1‬‬

‫‪14‬‬
‫ﺍﻟﺠﺪﻭﻝ‪:1‬ﺑﺮﻣﺠﺔ ﺍﻟﻘﻴﻢ‬

‫ﻧﻄﺎﻕﺍﻟﺒﺮﻧﺎﻣﺞ‬ ‫ﻣﺒﺮﻣﺠﺔﻣﺴﺒﻘﺎ‬ ‫ﻭﺻﻒ‬ ‫ﺑﺮﻧﺎﻣﺞ‬


‫ﻗﻴﻤﺔﻗﻴﺎﺳﻴﺔ‬ ‫ﺍﻟﻮﺿﻊﻻ‪.‬‬
‫ﻣﻦﺍﻟﻐﻄﺎء‪ 0.90 .‬ﺇﻟﻰ ﺍﻟﻬﻨﺪ‪0.8 .‬‬ ‫ﺍﻟﻬﻨﺪ‪0.92‬‬ ‫ﺍﻟﻬﺪﻑﺍﻟﻘﻮﺓ‬ ‫‪-01-‬‬
‫ﺑﺰﻳﺎﺩﺍﺕ‪ 0.01‬ﺧﻄﻮﺓ‬ ‫ﻋﺎﻣﻞ‬
‫ﻣﻦ‪ 2-‬ﺇﻟﻰ ‪ 4+‬ﺑﺰﻳﺎﺩﺍﺕ ‪ 0.5‬ﺧﻄﻮﺓ‬ ‫‪) 1.0-‬ﻋﺎﻣﻞ ﺍﻟﻄﺎﻗﺔ‬ ‫ﺍﻟﺘﺤﻮﻝﺍﻟﻤﺘﻮﺍﺯﻱ ‪PS‬‬ ‫‪-02-‬‬
‫ﺍﻟﻤﺴﺘﻬﺪﻑﺃﻗﻞ‬
‫ﻣﻦﺍﻟﻘﻴﻤﺔ ﺍﻟﻤﺤﺪﺩﺓ(‬
‫ﻣﻦ‪ 2-‬ﺇﻟﻰ ‪ 2+‬ﺑﺰﻳﺎﺩﺍﺕ ‪ 0.5‬ﺧﻄﻮﺓ‬ ‫‪1.0 +‬‬ ‫ﺣﺪﻭﺩﻻﻡ‬ ‫‪-03-‬‬
‫)ﺍﻟﺘﻌﻮﻳﺾ ﺍﻟﻤﻔﺮﻁ‬
‫ﺗﻢﺗﺠﻨﺒﻪ(‬
‫ﻣﻦ‪ 5‬ﺇﻟﻰ ‪ 500‬ﺛﺎﻧﻴﺔ ﻓﻲ ‪ 1‬ﺛﺎﻧﻴﺔ‪.‬‬ ‫‪45‬‬ ‫ﻭﻗﺖﺍﻟﺘﺒﺪﻳﻞ‬ ‫‪-04-‬‬
‫ﺧﻄﻮﺍﺕﺃﻭ ﺑﺴﺮﻋﺔ ﻋﺎﻟﻴﺔ‬ ‫ﺗﺄﺧﺮﻓﻲ‬
‫ﻓﻲ‪ 5‬ﺛﻮﺍﻥ‪(* .‬‬ ‫ﺛﻮﺍﻧﻲ‬
‫ﺍﻟﻮﺿﻊﺍﻟﺘﻠﻘﺎﺉﻲ = ‪ON‬‬ ‫ﻋﻠﻰ‬ ‫ﺍﻟﺘﻠﻘﺎﺉﻲ‪c / k‬‬ ‫‪-05-‬‬
‫ﺍﻟﻮﺿﻊﺍﻟﻴﺪﻭﻱ = ‪OFF‬‬ ‫ﻫﻮﻳﺔ‬
‫ﻋﻨﺪ"ﺗﺸﻐﻴﻞ" ‪ ،‬ﻳﺘﺤﻮﻝ ﺍﻟﺒﺮﻧﺎﻣﺞ‬
‫ﻣﺒﺎﺷﺮﺓﺇﻟﻰ ﻭﺿﻊ ﺍﻟﺒﺮﻧﺎﻣﺞ ﺭﻗﻢ‪-09- .‬‬

‫ﻣﻦ‪ 0.02‬ﺇﻟﻰ ‪ 2.0‬ﻓﻲ ‪ 0.01‬ﺧﻄﻮﺓ ﺃﻭ‬ ‫‪2.0‬‬ ‫ﺩﻟﻴﻞ‪c / k‬‬ ‫‪-06-‬‬


‫ﺑﺴﺮﻋﺔﻋﺎﻟﻴﺔ ﻓﻲ ‪ 0.05‬ﺧﻄﻮﺓ‪(* .‬‬ ‫ﺗﺤﺪﻳﺪﺍﻟﻘﻴﻤﺔ‬
‫‪4 :4 :4 :3 :2:1‬‬ ‫‪4 :4 :4 :2 :1:1‬‬ ‫‪1 :1 :1 :1 :1:1‬‬ ‫‪1 :1 :1 :1:1‬‬ ‫ﺍﻟﺘﺒﺪﻳﻞ‪-se‬‬ ‫‪-07-‬‬
‫‪6 :6 :6 :3 :2:1‬‬ ‫‪8 :8 :4 :2 :1:1‬‬ ‫‪2 :2 :2 :2 :1:1‬‬ ‫ﻛﻮﻳﻨﺲ‬
‫‪4 :4 :4 :4 :2:1‬‬ ‫‪2 :2 :2 :2 :2:1‬‬ ‫‪4 :4 :2 :2 :1:1‬‬
‫‪8 :8 :8 :4 :2:1‬‬ ‫‪3 :3 :3 :3 :2:1‬‬ ‫‪3 :3 :3 :2 :1:1‬‬
‫ﻣﻦ‪ 1‬ﺇﻟﻰ ‪6‬‬ ‫‪6‬‬ ‫ﻋﺪﺩﺍﻟﻤﺨﺎﻟﻔﺎﺕ‪-‬‬ ‫‪-08-‬‬
‫ﺍﻟﺘﻜﺘﻴﻜﺎﺕﺍﻟﻤﺴﺘﺨﺪﻣﺔ‬

‫‪ =0‬ﻻ ﺗﻮﺟﺪ ﻣﺮﺣﻠﺔ‬ ‫‪0‬‬ ‫ﺗﺤﺪﻳﺪ‬ ‫‪-09-‬‬


‫ﺛﺎﺑﺘﺔ‪ = 1‬ﺧﺮﺝ ﺛﺎﺑﺖ‬ ‫ﻣﺮﺍﺣﻞﺛﺎﺑﺘﺔ‬
‫‪ =2‬ﺍﻟﻨﻮﺍﺗﺞ ‪ 1‬ﻭ ‪ 2‬ﺛﺎﺑﺘﺔ ‪= 3‬‬
‫ﺍﻟﻨﻮﺍﺗﺞﻣﻦ ‪ 1‬ﺇﻟﻰ ‪ 3‬ﺛﺎﺑﺘﺔ‬

‫*( ﺑﺎﻟﻀﻐﻂ ﻋﻠﻰ ﺍﻷﺯﺭﺍﺭ "‪ "+‬ﺃﻭ "‪ "-‬ﻟﺒﻌﺾ ﺍﻟﻮﻗﺖ ‪ ،‬ﺳﻴﺘﻢ ﺗﻨﺸﻴﻂ ﻭﺿﻊ ﺍﻟﺴﺮﻋﺔ ﺍﻟﻌﺎﻟﻴﺔ‪.‬‬

‫‪15‬‬
‫ﺍﻟﺠﺪﻭﻝ‪1‬ﺑﺮﻣﺠﺔ ﺍﻟﻘﻴﻢ‬

‫ﻧﻄﺎﻕﺍﻟﺒﺮﻧﺎﻣﺞ‬ ‫ﻣﺒﺮﻣﺠﺔﻣﺴﺒﻘﺎ‬ ‫ﻭﺻﻒ‬ ‫ﺑﺮﻧﺎﻣﺞ‬


‫ﻗﻴﻤﺔﻗﻴﺎﺳﻴﺔ‬ ‫ﺍﻟﻮﺿﻊﻻ‪.‬‬
‫ﺗﺸﻐﻴﻞ= ﺗﻠﻘﺎﺉﻲ‬ ‫ﻋﻠﻰ‬ ‫ﺗﻠﻘﺎﺉﻲ‬ ‫‪-10-‬‬
‫ﻣﻄﻔﺄ= ﻳﺪﻭﻱ‬ ‫ﺗﺤﺪﻳﺪ‬
‫ﻋﻨﺪ"ﺗﺸﻐﻴﻞ" ‪ ،‬ﻳﻤﻜﻦ ﻗﺮﺍءﺓ ﺍﻟﻮﺿﻊ ‪11-‬‬ ‫ﺍﻟﺠﻬﺪﻭ‬
‫ﻓﻘﻂﻭﻟﻜﻦ ﻻ ﻳﻤﻜﻦ ﺗﻐﻴﻴﺮﻩ‪.‬‬ ‫ﺍﻟﻤﺼﺪﺭﺍﻟﺤﺎﻟﻲ‬
‫ﺍﻧﻈﺮﺍﻟﺠﺪﻭﻝ ‪2‬‬ ‫ﺗﻠﻘﺎﺉﻲ‬ ‫ﺃﺩﺧﻞﺃﻭ ﺍﻗﺮﺃ‬ ‫‪-11-‬‬
‫ﻫﻮﻳﺔ‬ ‫ﻃﺮﻳﻘﺔ‬
‫ﺍﻹﺗﺼﺎﻝ‬
‫ﻣﻦ‪ 5‬ﺇﻟﻰ ‪ 900‬ﺛﺎﻧﻴﺔ‪(* .‬‬ ‫‪60‬‬ ‫ﺍﻟﺘﺒﺪﻳﻞ‬ ‫‪-12-‬‬
‫ﺯﻣﻦ‬
‫ﺗﺸﻐﻴﻞ= ﺍﻟﺘﺒﺪﻳﻞ ﺍﻟﺪﻭﺭﻱ‬ ‫ﻋﻠﻰ‬ ‫ﺍﻹﻋﺪﺍﺩﺍﻟﺪﻭﺭﻱ ‪/‬‬ ‫‪-13-‬‬
‫ﺍﻟﺘﺒﺪﻳﻞﻏﻴﺮ ﺍﻟﺪﻭﺭﻱ = ‪OFF‬‬ ‫ﻏﻴﺮﺩﻭﺭﻱ‬
‫ﺍﻟﺘﺒﺪﻳﻞ‬
‫ﺩﻭﺭﺍﻥ‬
‫ﻣﻦ‪ OFF‬ﺇﻟﻰ ‪ 1000‬ﻳﺠﺐ ﺇﺩﺧﺎﻝ ﺍﻟﻘﻴﻤﺔ‬ ‫ﺇﻳﻘﺎﻑ‬ ‫ﻋﺘﺒﺔ‬ ‫‪-14-‬‬
‫ﻓﻲﻣﻔﺎﺗﻴﺢ ‪x1000‬‬ ‫ﺭﻗﻢﺍﻝ‬
‫ﺍﻟﺘﺒﺪﻳﻞ‬
‫ﺇﻧﺬﺍﺭ‬
‫ﺃﺩﺧﻞﺭﻗﻤﺎً ﻣﻦ ‪ 1‬ﺇﻟﻰ ‪ .6‬ﻋﻨﺪ ﻣﻐﺎﺩﺭﺓ ﻧﻘﻄﺔ‬ ‫‪0‬‬ ‫ﺍﻹﻟﻐﺎء‬ ‫‪-15-‬‬
‫ﺍﻟﻘﺎﺉﻤﺔﻫﺬﻩ ‪ ،‬ﺳﻴﺘﻢ ﺿﺒﻂ ﻋﺪﺍﺩ ﻣﺮﺣﻠﺔ‬ ‫ﻓﺮﺩ‬
‫ﺍﻟﻤﻜﺜﻒﺍﻟﻤﻄﺎﺑﻖ ﻋﻠﻰ ‪ .0‬ﺳﺘﺆﺩﻱ ﺍﻟﻨﻘﻄﺔ‬ ‫ﺍﻟﺘﺒﺪﻳﻞ‬
‫"‪ "ALL‬ﺇﻟﻰ ﺇﻋﺎﺩﺓ ﺗﻌﻴﻴﻦ ﺟﻤﻴﻊ ﺍﻟﻌﺪﺍﺩﺍﺕ‬ ‫ﻋﺪﺍﺩﺍﺕ‬
‫ﺇﻟﻰ‪.0‬‬
‫ﻣﻦ‪ 1‬ﺇﻟﻰ ‪ 7000‬ﻓﻲ ﺧﻄﻮﺍﺕ ﻣﻦ ‪ 1‬ﺃﻭ‬ ‫‪1‬‬ ‫ﺍﻟﻌﺎﺑﺮﺍﻟﺤﺎﻟﻲ‬ ‫‪-16-‬‬
‫ﺑﺴﺮﻋﺔﻋﺎﻟﻴﺔ ﻓﻲ ﺧﻄﻮﺍﺕ ‪(* .5‬‬ ‫ﺍﻟﻨﺴﺒﺔﺍﻟﺴﺎﺑﻘﺔ‬
‫ﻣﻦ‪ 1‬ﺇﻟﻰ ‪ 300‬ﻓﻲ ﺩﺭﺟﺎﺕ ‪ 1‬ﺃﻭ ﺑﺴﺮﻋﺔ‬ ‫‪1‬‬ ‫ﻋﺒﻮﺭﺍﻟﺠﻬﺪ‬ ‫‪-17-‬‬
‫ﻋﺎﻟﻴﺔﻓﻲ ﺧﻄﻮﺍﺕ ‪(* .5‬‬ ‫ﺍﻟﻨﺴﺒﺔﺍﻟﺴﺎﺑﻘﺔ‬

‫*( ﺑﺎﻟﻀﻐﻂ ﻋﻠﻰ ﺍﻷﺯﺭﺍﺭ "‪ "+‬ﺃﻭ "‪ "-‬ﻟﺒﻌﺾ ﺍﻟﻮﻗﺖ ‪ ،‬ﺳﻴﺘﻢ ﺗﻨﺸﻴﻂ ﻭﺿﻊ ﺍﻟﺴﺮﻋﺔ ﺍﻟﻌﺎﻟﻴﺔ‪.‬‬

‫‪16‬‬
‫ﺍﻟﺠﺪﻭﻝ‪1‬ﺑﺮﻣﺠﺔ ﺍﻟﻘﻴﻢ‬

‫ﻧﻄﺎﻕﺍﻟﺒﺮﻧﺎﻣﺞ‬ ‫ﻣﺒﺮﻣﺠﺔﻣﺴﺒﻘﺎ‬ ‫ﻭﺻﻒ‬ ‫ﺑﺮﻧﺎﻣﺞ‬


‫ﻗﻴﻤﺔﻗﻴﺎﺳﻴﺔ‬ ‫ﺍﻟﻮﺿﻊﻻ‪.‬‬
‫ﻣﻦ‪ 1‬ﺇﻟﻰ ‪ ٪20‬ﻓﻲ ﺧﻄﻮﺍﺕ ‪ ٪0.1‬ﺃﻭ‬ ‫‪5‬‬ ‫‪5‬ﺍﻟﻌﺎﺷﺮﻣﺘﻨﺎﺳﻖ‬ ‫‪-18-‬‬
‫‪٪0.5‬ﺧﻄﻮﺍﺕ ﺑﺴﺮﻋﺔ ﻋﺎﻟﻴﺔ‪(* .‬‬ ‫ﻋﺘﺒﺔﻓﻲ‪٪‬‬
‫ﻣﻦ‪ 1‬ﺇﻟﻰ ‪ ٪20‬ﻓﻲ ﺧﻄﻮﺍﺕ ‪ ٪0.1‬ﺃﻭ‬ ‫‪4‬‬ ‫‪7‬ﺍﻟﻌﺎﺷﺮﻣﺘﻨﺎﺳﻖ‬ ‫‪-19-‬‬
‫‪٪0.5‬ﺧﻄﻮﺍﺕ ﺑﺴﺮﻋﺔ ﻋﺎﻟﻴﺔ‪(* .‬‬ ‫ﻋﺘﺒﺔﻓﻲ‪٪‬‬
‫ﻣﻦ‪ 1‬ﺇﻟﻰ ‪ ٪20‬ﻓﻲ ﺧﻄﻮﺍﺕ ‪ ٪0.1‬ﺃﻭ‬ ‫‪3‬‬ ‫‪11‬ﺍﻟﻌﺎﺷﺮﻣﺘﻨﺎﺳﻖ‬ ‫‪-20-‬‬
‫‪٪0.5‬ﺧﻄﻮﺍﺕ ﺑﺴﺮﻋﺔ ﻋﺎﻟﻴﺔ‪(* .‬‬ ‫ﻋﺘﺒﺔﻓﻲ‪٪‬‬
‫ﻣﻦ‪ 1‬ﺇﻟﻰ ‪ ٪20‬ﻓﻲ ﺧﻄﻮﺍﺕ ‪ ٪0.1‬ﺃﻭ‬ ‫‪2.1‬‬ ‫‪13‬ﺍﻟﻌﺎﺷﺮﻣﺘﻨﺎﺳﻖ‬ ‫‪-21-‬‬
‫‪٪0.5‬ﺧﻄﻮﺍﺕ ﺑﺴﺮﻋﺔ ﻋﺎﻟﻴﺔ‪(* .‬‬ ‫ﻋﺘﺒﺔﻓﻲ‪٪‬‬
‫ﻣﻦ‪ 1.05‬ﺇﻟﻰ ‪ 3.0‬ﺃﺿﻌﺎﻑ ﺍﻟﻘﻴﻤﺔ ﺍﻻﺳﻤﻴﺔ‬ ‫‪1.3‬‬ ‫ﻣﺘﻨﺎﺳﻖ‬ ‫‪-22-‬‬
‫ﻓﻲ‪ 0.05‬ﺧﻄﻮﺓ ﺃﻭ ‪0.1‬‬ ‫ﺯﻳﺎﺩﺓﺍﻟﺘﻴﺎﺭ‬
‫ﺍﻟﺰﻳﺎﺩﺍﺕﻓﻲ ﺍﻟﺴﺮﻋﺔ ﺍﻟﻌﺎﻟﻴﺔ‬
‫ﺗﺸﻐﻴﻞﺃﻭ ﺇﻳﻘﺎﻑ‬ ‫ﻋﻠﻰ‬ ‫ﻋﺎﻣﻞﺍﻟﻘﻮﻯ‬ ‫‪-23-‬‬
‫ﻣﻦﺧﻼﻝ ﺿﺒﻂ "‪ ، "OFF‬ﻳﻤﻜﻦ ﺇﻳﻘﺎﻑ‬ ‫ﺍﻟﺘﻨﺒﻴﻪﻳﻨﻄﻠﻖ‬
‫ﺇﻧﺬﺍﺭﻋﺎﻣﻞ ﺍﻟﻄﺎﻗﺔ‪.‬‬ ‫ﺍﻹﺷﺎﺭﺓ‬
‫ﺑﺎﻟﻀﻐﻂﻋﻠﻰ ﺯﺭ "ﺿﺒﻂ" ‪ ،‬ﺳﻴﺘﻢ ﻋﺮﺽ‬ ‫ﺳﻴﻜﻮﻥﻓﻘﻂ‬ ‫ﻣﺠﻤﻮﻉ‪-kvar dis‬‬ ‫‪-24-‬‬
‫ﺍﻟﻄﺎﻗﺔﺍﻹﺟﻤﺎﻟﻴﺔ ﻓﻲ ‪.kvar‬‬ ‫ﻳﺘﻢﻋﺮﺿﻬﺎ ﻋﻨﺪﻣﺎ ﺗﻜﻮﻥ ﻓﻲ‬ ‫ﻟﻌﺐ‬
‫ﻋﻤﻠﻴﺔ‬

‫*( ﺑﺎﻟﻀﻐﻂ ﻋﻠﻰ ﺍﻷﺯﺭﺍﺭ "‪ "+‬ﺃﻭ "‪ "-‬ﻟﺒﻌﺾ ﺍﻟﻮﻗﺖ ‪ ،‬ﺳﻴﺘﻢ ﺗﻨﺸﻴﻂ ﻭﺿﻊ ﺍﻟﺴﺮﻋﺔ ﺍﻟﻌﺎﻟﻴﺔ‪.‬‬

‫‪17‬‬
‫ﺇﺫﺍﺗﻢ ﺗﺜﺒﻴﺖ ﺍﻟﻤﺤﻮﻝ ﺍﻟﺤﺎﻟﻲ ﻓﻲ ﺍﻻﺗﺠﺎﻩ ﺍﻟﺼﺤﻴﺢ ﻭﺗﻢ ﺗﻮﺻﻴﻞ ﺍﻟﻮﺻﻼﺕ (‪ S1 )k‬ﻭ (‪ S2 )l‬ﺑﺸﻜﻞ ﺻﺤﻴﺢ ﻣﻊ‬
‫ﻣﺮﺣﻞﺍﻟﺘﺤﻜﻢ ‪ ،‬ﻓﺈﻥ ﺍﻷﻧﻮﺍﻉ ﺍﻟﺘﺎﻟﻴﺔ ﻣﻦﺃﻭﺿﺎﻉ ﺍﻻﺗﺼﺎﻝﺻﺎﻟﺤﺔ‪:‬‬

‫ﺍﻟﺘﻮﺻﻴﻞﻋﻨﺪ ﻣﺴﺎﺭ ﺍﻟﺠﻬﺪ ‪/ N - L‬‬


‫ﻭﺿﻊﺍﺗﺼﺎﻝ‬
‫ﻻﻡ‪L / N -‬‬ ‫ﻻﻡ‪L / N -‬‬ ‫‪.L‬‬
‫ﻥ‪L3 -‬‬ ‫ﻥ‪L2 -‬‬ ‫ﻥ‪L1 -‬‬ ‫‪0‬‬
‫‪L3 - L2‬‬ ‫‪L2 - L1‬‬ ‫‪L1 - L3‬‬ ‫‪1‬‬
‫‪N - L2‬‬ ‫‪N - L1‬‬ ‫‪N - L3‬‬ ‫‪2‬‬
‫‪L1 - L2‬‬ ‫‪L3 - L1‬‬ ‫‪L2 - L3‬‬ ‫‪3‬‬
‫ﻥ‪L1 -‬‬ ‫ﻥ‪L3 -‬‬ ‫ﻥ‪L2 -‬‬ ‫‪4‬‬
‫‪L1 - L3‬‬ ‫‪L3 - L2‬‬ ‫‪L2 - L1‬‬ ‫‪5‬‬
‫‪N - L3‬‬ ‫‪N - L2‬‬ ‫‪N - L1‬‬ ‫‪6‬‬
‫‪L2 - L3‬‬ ‫‪L1 - L2‬‬ ‫‪L3 - L1‬‬ ‫‪7‬‬
‫ﻥ‪L2 -‬‬ ‫ﻥ‪L1 -‬‬ ‫ﻥ‪L3 -‬‬ ‫‪8‬‬
‫‪L2 - L1‬‬ ‫‪L1 - L3‬‬ ‫‪L3 - L2‬‬ ‫‪9‬‬
‫‪N - L1‬‬ ‫‪N - L3‬‬ ‫‪N - L2‬‬ ‫‪10‬‬
‫‪L3 - L1‬‬ ‫‪L2 - L3‬‬ ‫‪L1 - L2‬‬ ‫‪11‬‬
‫↑‬
‫↑‬
‫↑‬
‫‪L3‬‬ ‫‪L2‬‬ ‫‪L1‬‬ ‫ﻣﻮﻗﻊﺍﻟﺘﺼﻮﻳﺮ ﺍﻟﻤﻘﻄﻌﻲ ﻓﻲ ﺍﻟﻤﺮﺣﻠﺔ‪:‬‬

‫ﺍﻟﺠﺪﻭﻝ‪:2‬ﻭﺿﻊ ﺍﺗﺼﺎﻝ‬

‫ﻣﻠﺤﻮﻇﺔ‪:‬‬

‫ﺇﺫﺍﺗﻢ ﺗﻮﺻﻴﻞ (‪ S1 )k‬ﻭ (‪ S2 )l‬ﺑﻄﺮﻳﻘﺔ ﺧﺎﻃﺉﺔ ﺃﻭ ﺗﻢ ﺗﺜﺒﻴﺖ ‪ CT‬ﻓﻲ ﺍﺗﺠﺎﻩ ﺧﺎﻃﺊ ‪ ،‬ﻳﺠﺐ ﺇﺿﺎﻓﺔ ﺭﻗﻢ ﻭﺿﻊ‬
‫ﺍﻻﺗﺼﺎﻝﺑﻤﻘﺪﺍﺭ ‪ .6‬ﺇﺫﺍ ﻛﺎﻧﺖ ﺍﻟﻨﺘﻴﺠﺔ ﺃﻋﻠﻰ ﻣﻦ ‪ ، 11‬ﻓﻴﺠﺐ ﻃﺮﺡ ‪ .12‬ﺗﺘﻮﺍﻓﻖ ﺍﻟﻨﺘﻴﺠﺔ ﻣﻊ ﺭﻗﻢ ﻭﺿﻊ ﺍﻻﺗﺼﺎﻝ‬
‫ﺍﻟﺬﻱﻳﺠﺐ ﺇﺩﺧﺎﻟﻪ‪.‬‬

‫‪18‬‬
‫ﺍﻟﺸﻜﻞ‪:5‬ﺍﺳﺘﺠﺎﺑﺔ ﺍﻟﺘﺤﻜﻢ ﺑﻌﺪ ﺗﺤﺪﻳﺪ ﻋﺎﻣﻞ‬ ‫‪5.1‬ﺗﺤﺪﻳﺪ ﻋﺎﻣﻞ ﺍﻟﻄﺎﻗﺔ ﺍﻟﻤﺴﺘﻬﺪﻑ‬
‫ﺍﻟﻘﺪﺭﺓﺍﻟﻤﺴﺘﻬﺪﻑ = ‪ ind 0.92‬؛ ‪ = L‬ﺇﻳﻘﺎﻑ ؛ ‪0‬‬
‫ﻳﻤﻜﻦﺿﺒﻂ ﻋﺎﻣﻞ ﺍﻟﻄﺎﻗﺔ ﺍﻟﻤﺴﺘﻬﺪﻑ ﺍﻟﻤﻄﻠﻮﺏ ﻣﻦ‬
‫= ‪PS‬‬
‫ﺍﻟﻐﻄﺎء‪ 0.9.‬ﺇﻟﻰ ﺍﻟﻬﻨﺪ‪ 0.8 .‬ﻓﻲ ‪ 0.01‬ﺧﻄﻮﺓ‪.‬‬
‫ﻳﻤﻜﻦﺭﺅﻳﺔ ﻃﺮﻳﻘﺔ ﺗﺸﻐﻴﻞ ﻫﺬﺍ ﺍﻟﺘﻌﺪﻳﻞ ﻓﻲ ﺍﻟﺸﻜﻞ ‪4‬‬
‫ﺭﺩﺍﻟﻔﻌﻞ ﺍﻟﺤﺎﻟﻲ‬

‫ﻭﺍﻟﺸﻜﻞ‪.5‬‬
‫ﺍﻟﻬﻨﺪ‬

‫ﻣﻔﺘﻮﺡ‬ ‫‪3‬‬

‫‪2‬‬
‫ﺇﺫﺍﻛﺎﻥ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻳﻌﻤﻞ ﺿﻤﻦ ﻧﻄﺎﻕ ﺍﻟﻨﻄﺎﻕ‬
‫ﺍﻟﻤﻮﺿﺢﻓﻠﻦ ﻳﺘﻢ ﺗﻨﺸﻴﻂ ﺃﻱ ﻋﻤﻠﻴﺎﺕ ﺗﺤﻮﻳﻞ‪.‬‬
‫ﺗﺠﺪﻳﺪ‬

‫ﺍﻟﺘﻴﺎﺭﺍﻟﻨﺸﻂ‬
‫ﻣﻐﻠﻖ‬
‫ﻭﻣﻊﺫﻟﻚ ‪ ،‬ﺇﺫﺍ ﻛﺎﻥ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻳﻌﻤﻞ ﺧﺎﺭﺝ ﻧﻄﺎﻕ‬
‫ﺍﻟﻨﻄﺎﻕ ‪،‬ﻓﺴﻴﺤﺎﻭﻝ ‪ RM 9606‬ﺃﻥ ﻳﻜﻮﻥ ﺿﻤﻦ‬
‫‪2-‬‬
‫ﻧﻄﺎﻕﺍﻟﻨﻄﺎﻕ ﻣﻊ ﺍﻟﺤﺪ ﺍﻷﺩﻧﻰ ﻣﻦ ﺍﻟﺘﺒﺪﻳﻞ‪.‬‬
‫‪3-‬‬
‫ﺗﻘﺴﻴﻢﻣﻘﻴﺎﺱ ﻭﺍﺣﺪ‬
‫ﻳﺘﻮﺍﻓﻖﻣﻊ ‪ * 0.65‬ﺃﺻﻐﺮ‬
‫ﻣﺮﺣﻠﺔﻣﻜﺜﻒ‬
‫ﻗﺒﻌﺔ‬ ‫ﺍﻟﺸﻜﻞ‪:4‬ﺍﺳﺘﺠﺎﺑﺔ ﺍﻟﺘﺤﻜﻢ ﺑﻌﺪ ﺗﺤﺪﻳﺪ ﻋﺎﻣﻞ‬
‫ﺍﻟﻘﺪﺭﺓﺍﻟﻤﺴﺘﻬﺪﻑ = ‪ 1‬؛ ‪ = L‬ﺇﻳﻘﺎﻑ ؛ ‪PS = 0‬‬
‫ﺭﺩﺍﻟﻔﻌﻞ ﺍﻟﺤﺎﻟﻲ‬
‫ﻓﻲﺍﻟﺸﻜﻞ ‪ ، 5‬ﻳﻤﻜﻦ ﺃﻳﻀﺎً ﺭﺅﻳﺔ ﺳﻠﻮﻙ ﻣﺮﺣﻞ‬ ‫ﺗﻘﺴﻴﻢﻣﻘﻴﺎﺱ ﻭﺍﺣﺪ‬
‫ﻳﺘﻮﺍﻓﻖﻣﻊ ‪ * 0.65‬ﺃﺻﻐﺮ‬ ‫ﺍﻟﻬﻨﺪ‬

‫ﺍﻟﺘﺤﻜﻢﺃﺛﻨﺎء ﻋﻤﻠﻴﺔ ﺍﻟﺘﻐﺬﻳﺔ ﺍﻟﺮﺍﺟﻌﺔ‪ .‬ﻻ ﻳﻨﻌﻜﺲ "ﺍﻟﺘﻮﺍء‬ ‫ﻣﺮﺣﻠﺔﻣﻜﺜﻒ‬

‫" ﻓﻲ ﺍﻟﻨﻄﺎﻕ )ﺍﻟﺨﻂ ﺍﻟﻤﻤﻴﺰ( ﻓﻲ ﻋﻤﻠﻴﺔ ﺍﻟﺘﻐﺬﻳﺔ‬ ‫‪3‬‬


‫ﺍﻟﺮﺍﺟﻌﺔﻭﻟﻜﻨﻪ ﻳﻤﺘﺪ ﻋﻨﺪ ﻧﻘﻄﺔ ﺗﻘﺎﻃﻊ ﺧﻂ ﻣﺮﻛﺰ‬ ‫ﻣﻔﺘﻮﺡ‬ ‫‪2‬‬
‫ﺍﻟﻄﺎﻗﺔﺍﻟﺘﻔﺎﻋﻠﻲ )ﺍﻟﻤﺤﻮﺭ( ﻣﻊ ﺧﻂ ﺗﺸﻐﻴﻞ ﺍﻟﺘﻐﺬﻳﺔ‬
‫ﺍﻟﻤﺮﺗﺪﺓ‪.‬‬ ‫ﺗﺠﺪﻳﺪ‬
‫ﺍﻟﺘﻴﺎﺭﺍﻟﻨﺸﻂ‬

‫ﻣﻐﻠﻖ‬
‫‪2-‬‬
‫ﻋﻦﻃﺮﻳﻖ ﺗﺤﻮﻳﻞ ﺍﻟﻨﻄﺎﻕ ﺇﻟﻰ ﺍﻟﻨﻄﺎﻕ ﺍﻟﺴﻌﻮﻱ )ﺍﻧﻈﺮ‬
‫‪3-‬‬
‫ﺍﻟﺸﻜﻞ‪ 7‬ﻓﻲ ﺍﻟﻘﺴﻢ ‪ ، (5.2‬ﻳﻤﻜﻦ ﺗﺠﻨﺐ ﺣﺪﻭﺙ ﻗﻮﺓ‬
‫ﺗﻔﺎﻋﻠﻴﺔﺣﺜﻴﺔّ ﺃﺛﻨﺎء ﻋﻤﻠﻴﺔ ﺍﻟﺘﻐﺬﻳﺔ ﺍﻟﺮﺍﺟﻌﺔ ﺗﻘﺮﻳﺒﺎً‪.‬‬
‫ﻗﺒﻌﺔ‬

‫ﻋﻨﺪﻣﺎﻳﺘﻢ ﺗﻌﻴﻴﻦ ﻭﺿﻊ ﻋﺎﻣﻞ ﺍﻟﻘﺪﺭﺓ ﺍﻟﺴﻌﻮﻱ‬


‫ﺍﻟﻤﺴﺘﻬﺪﻑ ‪،‬ﻳﻨﻌﻜﺲ ﻧﻄﺎﻕ ﺍﻟﺘﺤﻜﻢ ﻣﻦ ﺟﺎﻧﺐ‬
‫ﺍﻟﻌﺮﺽﺇﻟﻰ ﺟﺎﻧﺐ ﺍﻟﺘﻐﺬﻳﺔ ﺍﻟﻤﺮﺗﺪﺓ‪) .‬ﺍﻧﻈﺮ ﺍﻟﺸﻜﻞ ‪(10‬‬
‫‪.‬‬

‫‪19‬‬
‫ﺍﻟﺸﻜﻞ‪:7‬ﺍﺳﺘﺠﺎﺑﺔ ﺍﻟﺘﺤﻜﻢ ﺑﻌﺪ ﺗﺤﺪﻳﺪ ﻋﺎﻣﻞ‬ ‫‪5.2‬ﺍﻟﺘﺤﻮﻝ ﺍﻟﻤﺘﻮﺍﺯﻱ )‪(PS‬‬
‫ﺍﻟﻘﺪﺭﺓﺍﻟﻤﺴﺘﻬﺪﻑ = ‪ ind 0.92‬؛ ‪ = L‬ﺇﻳﻘﺎﻑ ؛‬
‫ﻳﺘﺴﺒﺐﻫﺬﺍ ﺍﻹﻋﺪﺍﺩ ﻓﻲ ﺣﺪﻭﺙ ﺇﺯﺍﺣﺔ ﻣﺘﻮﺍﺯﻳﺔ ﻟﻨﻄﺎﻕ‬
‫‪PS =-1.0‬‬
‫ﺍﻟﻨﻄﺎﻕﻛﻤﺎ ﻫﻮ ﻣﻮﺿﺢ ﻓﻲ ﺍﻟﺸﻜﻞ ‪ 4‬ﺣﺴﺐ ﺍﻟﻘﻴﻤﺔ‬
‫ﺍﻟﻤﺤﺪﺩﺓ‪.‬‬
‫ﺭﺩﺍﻟﻔﻌﻞ ﺍﻟﺤﺎﻟﻲ‬

‫ﺳﻮﻑﻳﺘﺤﻮﻝ ﺇﻟﻰ ﺍﻻﺗﺠﺎﻩ ﺍﻻﺳﺘﻘﺮﺍﺉﻲ ﺇﺫﺍ ﺗﻢ‬


‫ﺍﻟﻬﻨﺪ‬

‫ﺍﺳﺘﺨﺪﺍﻡﻋﻼﻣﺔ ﺍﻟﺠﻤﻊ ﻭﺇﻟﻰ ﺍﻻﺗﺠﺎﻩ ﺍﻟﺴﻌﻮﻱ ﺇﺫﺍ ﺗﻢ‬


‫ﺍﺳﺘﺨﺪﺍﻡﻋﻼﻣﺔ ﺍﻟﻄﺮﺡ‪.‬‬
‫ﻣﻔﺘﻮﺡ‬ ‫‪2‬‬
‫‪1‬‬
‫ﻳﻤﻜﻦﺗﻌﻴﻴﻦ ﺍﻟﻘﻴﻢ ﻣﻦ ‪ 2-‬ﺇﻟﻰ ‪ 4+‬ﻓﻲ ‪ 0.5‬ﺧﻄﻮﺓ‪.‬‬
‫ﺍﻟﺘﻴﺎﺭﺍﻟﻨﺸﻂ‬ ‫ﺗﺠﺪﻳﺪ‬ ‫ﻳﺘﻢﺗﻮﺿﻴﺢ ﺍﻟﺘﺄﺛﻴﺮﺍﺕ ﻣﻦ ﺧﻼﻝ ﺍﻟﻤﺜﺎﻟﻴﻦ ﻓﻲ ﺍﻟﺸﻜﻞ‬
‫‪6‬ﻭﺍﻟﺸﻜﻞ ‪.7‬‬
‫ﻣﻐﻠﻖ‬

‫‪23-‬‬ ‫ﺍﻟﺸﻜﻞ‪:6‬ﺍﺳﺘﺠﺎﺑﺔ ﺍﻟﺘﺤﻜﻢ ﺑﻌﺪ ﺗﺤﺪﻳﺪ ﻋﺎﻣﻞ‬


‫ﺗﻘﺴﻴﻢﻣﻘﻴﺎﺱ ﻭﺍﺣﺪ‬ ‫ﺍﻟﻘﺪﺭﺓﺍﻟﻤﺴﺘﻬﺪﻑ = ‪ 1‬؛ ‪ = L‬ﺇﻳﻘﺎﻑ ؛‬
‫ﻳﺘﻮﺍﻓﻖﻣﻊ ‪ * 0.65‬ﺃﺻﻐﺮ‬
‫ﻣﺮﺣﻠﺔﻣﻜﺜﻒ‬ ‫ﻗﺒﻌﺔ‬ ‫‪PS = +1.0‬‬
‫ﺭﺩﺍﻟﻔﻌﻞ ﺍﻟﺤﺎﻟﻲ‬
‫ﻋﺎﻣﻞﺍﻟﻘﺪﺭﺓ ﺍﻟﻤﺴﺘﻬﺪﻑ ﺍﻟﻤﺤﺪﺩ ﻫﻮ ﺍﻟﺤﺪ ﺍﻷﺩﻧﻰ‬ ‫ﺍﻟﻬﻨﺪ‬

‫ﻟﻨﻄﺎﻕﻧﻄﺎﻕ ﺍﻟﺘﺤﻜﻢ‪.‬‬
‫)ﻫﺬﺍ ﻫﻮ ﺍﻹﻋﺪﺍﺩ ﺍﻟﻤﻮﺻﻰ ﺑﻪ ﻋﻨﺪ ﺍﺳﺘﺨﺪﺍﻡ‬ ‫ﻣﻔﺘﻮﺡ‬ ‫‪3‬‬

‫ﺍﻟﻤﻮﻟﺪﺍﺕﻏﻴﺮ ﺍﻟﻤﺘﺰﺍﻣﻨﺔ ﺑﺎﻟﺘﻮﺍﺯﻱ‪(.‬‬


‫‪1‬‬
‫ﺍﻟﺘﻴﺎﺭﺍﻟﻨﺸﻂ‬
‫ﺗﺠﺪﻳﺪ‬

‫‪5.3‬ﺣﺪﻭﺩ )‪(L‬‬ ‫ﻣﻐﻠﻖ‬


‫‪1-‬‬

‫ﻳﻮﻓﺮﻫﺬﺍ ﺍﻹﻋﺪﺍﺩ ﺇﻣﻜﺎﻧﻴﺎﺕ ﺟﺪﻳﺪﺓ ﻟﻢ ﻳﻜﻦ ﻣﻦ‬ ‫‪2-‬‬

‫ﺍﻟﻤﻤﻜﻦﺗﺤﻘﻴﻘﻬﺎ ﻣﻦ ﻗﺒﻞ ﺑﺴﺒﺐ ﺍﻟﻤﺘﻄﻠﺒﺎﺕ‬ ‫‪3-‬‬


‫ﺗﻘﺴﻴﻢﻣﻘﻴﺎﺱ ﻭﺍﺣﺪ‬
‫ﺍﻟﻤﺘﻌﺎﺭﺿﺔ‪.‬‬ ‫ﻳﺘﻮﺍﻓﻖﻣﻊ ‪ * 0.65‬ﺃﺻﻐﺮ ﻣﺮﺣﻠﺔ‬
‫ﻣﻜﺜﻒ‬
‫ﻗﺒﻌﺔ‬
‫ﻧﻄﺎﻕﻗﻴﻢ ‪ L‬ﻫﻮ ‪ 2-‬ﺇﻟﻰ ‪ 2+‬ﻓﻲ ﺧﻄﻮﺍﺕ ‪ 0.5‬ﻭﺍﻹﻋﺪﺍﺩ‬
‫"‪ ."OFF‬ﺗﺤﺪﻳﺪ ﻗﻴﻤﺔ ﺍﻟﺤﺪ ‪ 1‬ﻭﻋﺎﻣﻞ ﺍﻟﻘﺪﺭﺓ‬ ‫ﻭﺑﺎﻟﺘﺎﻟﻲﻓﺈﻥ ﻋﺎﻣﻞ ﺍﻟﻘﺪﺭﺓ ﺍﻟﻤﺴﺘﻬﺪﻑ ﺍﻟﻤﺤﺪﺩ ﻫﻮ‬
‫ﺍﻟﻤﺴﺘﻬﺪﻑ‪ 1.0‬ﻟﻪ ﻧﻔﺲ ﺗﺄﺛﻴﺮ ﺍﻻﻧﺰﻳﺎﺡ ﺍﻟﻤﺘﻮﺍﺯﻱ‪.‬‬ ‫ﺍﻟﺤﺪﺍﻷﻋﻠﻰ ﻟﻨﻄﺎﻕ ﺍﻟﺘﺤﻜﻢ‪.‬‬
‫ﺑﺎﻟﻨﺴﺒﺔﻟﻌﺎﻣﻞ ﺍﻟﻘﺪﺭﺓ ﺍﻟﻤﺴﺘﻬﺪﻑ ﺑﺨﻼﻑ ‪، 1.0‬‬
‫ﺗﻮﺟﺪﺧﺎﺻﻴﺔ "ﻣﻠﺘﻮﻳﺔ" ﻛﻤﺎ ﻫﻮ ﻣﻮﺿﺢ ﻓﻲ ﺍﻟﺸﻜﻞ ‪.8‬‬

‫‪20‬‬
‫ﺍﻟﺸﻜﻞ‪:9‬ﺍﺳﺘﺠﺎﺑﺔ ﺍﻟﺘﺤﻜﻢ ﺑﻌﺪ ﺗﺤﺪﻳﺪ ﻋﺎﻣﻞ ﺍﻟﻘﺪﺭﺓ‬ ‫ﻟﺬﻟﻚ ‪،‬ﻳﺤﺪﺩ ﺍﻟﻘﻴﺪ ﺣﺪﺍً ﻣﻄﻠﻘﺎً ﻟﻠﻘﺪﺭﺓ ﺍﻟﺘﻔﺎﻋﻠﻴﺔ ‪،‬‬
‫ﺍﻟﻤﺴﺘﻬﺪﻑ= ‪ ind 0.92‬؛ ‪ PS = -1.0‬؛ ‪L = +1.0‬‬ ‫ﻭﺍﻟﺬﻱﻻ ﻳﻨﺘﻘﻞ ﺩﻭﻧﻪ ﻧﻄﺎﻕ ﺍﻟﺘﺤﻜﻢ‪.‬‬

‫ﺭﺩﺍﻟﻔﻌﻞ ﺍﻟﺤﺎﻟﻲ‬
‫ﺍﻟﻬﻨﺪ‬ ‫ﺍﻟﺸﻜﻞ‪:8‬ﺍﺳﺘﺠﺎﺑﺔ ﺍﻟﺘﺤﻜﻢ ﺑﻌﺪ ﺗﺤﺪﻳﺪ ﻋﺎﻣﻞ ﺍﻟﻘﺪﺭﺓ‬
‫‪4‬‬
‫ﺍﻟﻤﺴﺘﻬﺪﻑ= ‪ ind 0.92‬؛ ‪ PS = 0‬؛ ‪L = +1.0‬‬
‫ﻣﻔﺘﻮﺡ‬
‫‪3‬‬

‫ﺭﺩﺍﻟﻔﻌﻞ ﺍﻟﺤﺎﻟﻲ‬
‫ﺍﻟﻬﻨﺪ‬
‫ﺗﺠﺪﻳﺪ‬
‫‪4‬‬
‫ﺍﻟﻄﺎﻗﺔﺍﻟﻨﺸﻄﺔ‬ ‫ﻣﻔﺘﻮﺡ‬ ‫‪3‬‬
‫ﻣﻐﻠﻖ‬ ‫‪1-‬‬
‫‪2-‬‬
‫‪3-‬‬ ‫ﺗﺠﺪﻳﺪ‬

‫ﺗﻘﺴﻴﻢﻣﻘﻴﺎﺱ ﻭﺍﺣﺪ‬ ‫ﺍﻟﻄﺎﻗﺔﺍﻟﻨﺸﻄﺔ‬


‫ﻳﺘﻮﺍﻓﻖﻣﻊ ‪ * 0.65‬ﺃﺻﻐﺮ‬ ‫ﻣﻐﻠﻖ‬ ‫‪1-‬‬
‫ﻣﺮﺣﻠﺔﻣﻜﺜﻒ‬ ‫ﻗﺒﻌﺔ‬
‫‪2-‬‬

‫ﻳﻮﺿﺢﻫﺬﺍ ﺍﻟﻤﺜﺎﻝ‪:‬‬ ‫ﺗﻘﺴﻴﻢﻣﻘﻴﺎﺱ ﻭﺍﺣﺪ‬


‫ﻳﺘﻮﺍﻓﻖﻣﻊ ‪ * 0.65‬ﺃﺻﻐﺮ‬
‫ﻣﺮﺣﻠﺔﻣﻜﺜﻒ‬
‫• ﻓﻲﻧﻄﺎﻕ ﺍﻟﻄﺎﻗﺔ "ﺍﻟﻌﻠﻮﻱ" ‪ ،‬ﻳﺘﻢ ﺗﺤﺪﻳﺪ ﻋﺎﻣﻞ‬ ‫ﻗﺒﻌﺔ‬

‫ﺍﻟﻘﺪﺭﺓﺍﻟﻤﺤﺪﺩ ﻋﻠﻰ ﺃﻧﻪ ﻗﻴﻤﺔ ﺍﻟﺤﺪ ﺍﻷﺩﻧﻰ‪.‬‬


‫ﻫﺬﺍﺍﻹﻋﺪﺍﺩ ﻟﻪ ﺍﻟﺘﺄﺛﻴﺮﺍﺕ ﺍﻟﺘﺎﻟﻴﺔ‪:‬‬

‫• ﻳﺘﻢﺗﺠﻨﺐ ﺍﻟﺘﻌﻮﻳﺾ ﺍﻟﺰﺍﺉﺪ ﻓﻲ ﻧﻄﺎﻕ ﺍﻟﺤﻤﻞ‬ ‫• ﻳﺘﻢﺑﻠﻮﻍ ﻋﺎﻣﻞ ﺍﻟﻘﺪﺭﺓ ‪ ،‬ﻓﻲ ﺍﻟﻤﺘﻮﺳﻂ ‪ ،‬ﻓﻲ‬
‫ﺍﻟﻤﻨﺨﻔﺾ‪.‬‬ ‫ﻧﻄﺎﻕﺍﻟﻘﺪﺭﺓ "ﺍﻷﻋﻠﻰ"‪.‬‬

‫ﻫﺬﺍﺍﻹﻋﺪﺍﺩ ﻫﻮ ﺍﻹﻋﺪﺍﺩ ﺍﻟﻌﺎﺩﻱ ﻋﻨﺪ ﺍﻟﺘﺴﻠﻴﻢ‬ ‫• ﻳﺘﻢﺗﺠﻨﺐ ﺍﻟﺘﻌﻮﻳﺾ ﺍﻟﺰﺍﺉﺪ )ﺍﻟﺤﻤﻞ ﺍﻟﺴﻌﻮﻱ(‬
‫ﻣﻦﺍﻟﻤﺼﻨﻊ ﻭﻳﻤﺜﻞ ﺃﻓﻀﻞ ﺧﺎﺻﻴﺔ ﺗﺤﻜﻢ‬ ‫ﻓﻲﻧﻄﺎﻕ ﺍﻟﺤﻤﻞ ﺍﻟﻤﻨﺨﻔﺾ‪.‬‬
‫ﻣﻤﻜﻨﺔﻟﻤﻌﻈﻢ ﺍﻟﺘﻄﺒﻴﻘﺎﺕ‪.‬‬
‫ﻣﺰﻳﺞﻣﻨﺎﺳﺐ ﻣﻦ "ﺍﻟﺘﺤﻮﻝ ﺍﻟﻤﺘﻮﺍﺯﻱ" ﻭ "ﺍﻟﻘﻴﺪ"‬
‫ﻣﻮﺿﺢﻓﻲ ﺍﻟﺸﻜﻞ ‪.9‬‬
‫ﻳﻮﺿﺢﺍﻟﺸﻜﻞ ‪ 10‬ﺍﻟﺘﺎﻟﻲ ﺧﺼﺎﺉﺺ ﻧﻄﺎﻕ ﺍﻟﺘﺤﻜﻢ‬
‫ﻋﻨﺪﺿﺒﻄﻪ ﻟﻌﺎﻣﻞ ﻗﺪﺭﺓ ﻣﺴﺘﻬﺪﻑ ﺳﻌﻮﻱ‪ .‬ﻓﻲ‬

‫‪21‬‬
‫ﻓﻤﺜﻼ‪:‬‬
‫ﻣﺮﺣﻠﺘﺎﻥﻣﻄﻠﻮﺑﺘﺎﻥ = ﺗﺄﺧﻴﺮ ﻭﻗﺖ ﺍﻟﺘﺒﺪﻳﻞ ‪) 2 /‬‬ ‫ﻓﻲﻫﺬﻩ ﺍﻟﺤﺎﻟﺔ ‪ ،‬ﻻ ﻳﺘﻢ ﺇﻃﺎﻟﺔ ﻧﻄﺎﻕ ﺍﻟﺘﺤﻜﻢ ﻋﻨﺪ ﻣﺤﻮﺭ‬
‫ﺗﻘﻠﻴﻞﺑﻤﻘﺪﺍﺭ ﺍﻟﻨﺼﻒ( ﺃﻭ‬ ‫ﺍﻟﻄﺎﻗﺔﺍﻟﺘﻔﺎﻋﻠﻴﺔ ﻓﻲ ﺟﺎﻧﺐ ﺍﻟﺘﻐﺬﻳﺔ ﺍﻟﺨﻠﻔﻲ ‪ ،‬ﻭﻟﻜﻦ‬
‫‪3‬ﻣﺮﺍﺣﻞ ﻣﻄﻠﻮﺑﺔ = ﺗﺄﺧﻴﺮ ﻭﻗﺖ ﺍﻟﺘﺒﺪﻳﻞ ‪) 3 /‬‬ ‫ﻳﺘﻢﻋﻜﺴﻪ ﻣﻦ ﺟﺎﻧﺐ ﺍﻹﻣﺪﺍﺩ ﺇﻟﻰ ﺟﺎﻧﺐ ﺍﻟﺘﻐﺬﻳﺔ‬
‫ﺗﻘﻠﻴﻞﺑﻤﻘﺪﺍﺭ ﺍﻟﺜﻠﺜﻴﻦ(‪.‬‬ ‫ﺍﻟﻤﺮﺗﺪﺓ‪.‬‬
‫ﻣﻦﺃﺟﻞ ﺍﻟﺤﻔﺎﻅ ﻋﻠﻰ ﺗﺂﻛﻞ ﺟﻬﺎﺕ ﺍﻻﺗﺼﺎﻝ ﺇﻟﻰ ﺍﻟﺤﺪ‬
‫ﺍﻟﺸﻜﻞ‪:10‬ﺍﺳﺘﺠﺎﺑﺔ ﺍﻟﺘﺤﻜﻢ ﺑﻌﺪ ﺗﺤﺪﻳﺪ ﻋﺎﻣﻞ‬
‫ﺍﻷﺩﻧﻰ ‪،‬ﻳﺠﺐ ﺿﺒﻂ ﻭﻗﺖ ﺗﺄﺧﻴﺮ ﺍﻟﺘﺒﺪﻳﻞ ﻋﻠﻰ ﺃﻗﻞ‬
‫ﺍﻟﻘﺪﺭﺓﺍﻟﻤﺴﺘﻬﺪﻑ = ‪ 0.95‬ﻏﻄﺎء ؛ ‪ L = 1.0‬؛ ‪= 0‬‬
‫ﻣﻦ‪ 45‬ﺛﺎﻧﻴﺔ ﻓﻘﻂ ﻓﻲ ﺍﻟﺤﺎﻻﺕ ﺍﻻﺳﺘﺜﻨﺎﺉﻴﺔ‪ .‬ﻓﺘﺮﺓ‬
‫‪PS‬‬
‫ﺍﻟﺘﻔﺮﻳﻎ ‪،‬ﺍﻟﺘﻲ ﺗﻀﻤﻦ ﺗﻔﺮﻳﻎ ﺍﻟﻤﻜﺜﻔﺎﺕ ﺑﺎﻟﻜﺎﻣﻞ ﻗﺒﻞ‬
‫ﺗﺸﻐﻴﻠﻬﺎﻣﺮﺓ ﺃﺧﺮﻯ ‪ ،‬ﺗﺘﺠﺎﻭﺯ ﻭﻗﺖ ﺗﺄﺧﻴﺮ ﺍﻟﺘﺒﺪﻳﻞ )‬
‫ﺭﺩﺍﻟﻔﻌﻞ ﺍﻟﺤﺎﻟﻲ‬
‫ﺗﻘﺴﻴﻢﻣﻘﻴﺎﺱ ﻭﺍﺣﺪ‬
‫ﺍﻧﻈﺮﺍﻟﻘﺴﻢ ‪.(5.12‬‬
‫ﺍﻟﻬﻨﺪ‬
‫ﻳﺘﻮﺍﻓﻖﻣﻊ ‪ * 0.65‬ﺃﺻﻐﺮ‬
‫ﻣﺮﺣﻠﺔﻣﻜﺜﻒ‬
‫‪3‬‬
‫‪2‬‬

‫‪5.5‬ﺗﺤﺪﻳﺪ ﺍﻟﻤﺮﺣﻠﺔ ﺍﻟﺤﺎﻟﻴﺔ ﺍﻟﺘﻠﻘﺎﺉﻴﺔ )‪k‬‬ ‫ﻣﻔﺘﻮﺡ‬

‫‪" (c /‬ﺗﺸﻐﻴﻞ ‪ /‬ﺇﻳﻘﺎﻑ"‬ ‫ﺍﻟﺘﻴﺎﺭﺍﻟﻨﺸﻂ‬ ‫ﺗﺠﺪﻳﺪ‬

‫ﻳﺤﺘﻮﻱ‪ RM 9606‬ﻋﻠﻰ ﺗﻌﺮﻳﻒ ﺗﻠﻘﺎﺉﻲ ﻟـ ‪ ، c / k‬ﺃﻱ‬ ‫‪2-‬‬


‫ﺃﻧﻪﻳﺤﺴﺐ ﺗﻴﺎﺭ ﺍﻻﺳﺘﺠﺎﺑﺔ ﺍﻟﻤﻨﺎﺳﺐ ﻓﻲ ﺍﻟﻤﺮﺓ ﺍﻷﻭﻟﻰ‬ ‫ﻣﻐﻠﻖ‬ ‫‪3-‬‬
‫ﺍﻟﺘﻲﻳﺘﻢ ﻓﻴﻬﺎ ﺗﻨﺸﻴﻂ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ‪ .‬ﻳﺘﻜﺮﺭ ﻫﺬﺍ‬
‫ﺍﻹﺟﺮﺍءﺣﺘﻰ ﻳﺘﻢ ﺗﺤﺪﻳﺪ ﻣﻘﺪﺍﺭ ﺍﻟﻘﺪﺭﺓ ﺍﻟﺴﻌﻮﻳﺔ ﻟﻜﻞ‬
‫ﻣﺮﺣﻠﺔﻭﻳﺘﻢ ﺣﺴﺎﺏ ﻗﻴﻤﺔ ‪ .c / k‬ﻳﻤﻜﻦ ﺿﺒﻂ ﺧﺎﺻﻴﺔ‬ ‫ﻗﺒﻌﺔ‬
‫ﺍﻟﺘﻌﺮﻑﺍﻟﺘﻠﻘﺎﺉﻲ ﻋﻠﻰ ‪ c / k‬ﻋﻠﻰ "‪ "ON‬ﺃﻭ "‪."OFF‬‬

‫‪5.4‬ﺗﺒﺪﻳﻞ ﺗﺄﺧﻴﺮ ﺍﻟﻮﻗﺖ‬


‫ﻳﻤﻜﻦﺿﺒﻂ ﻓﺘﺮﺓ ﺗﺄﺧﻴﺮ ﻭﻗﺖ ﺍﻟﺘﺒﺪﻳﻞ ﺑﻴﻦ ﻗﻴﻢ ﻣﻦ ‪5‬‬
‫ﻋﻨﺪﻣﺎﻋﻠﻰ"ﻳﻌﻤﻞ ‪ RM 9606‬ﻣﻊ ﺗﻴﺎﺭﺍﺕ ﺍﻟﻤﺮﺣﻠﺔ‬
‫ﺇﻟﻰ‪ 500‬ﺛﺎﻧﻴﺔ ﻓﻲ ‪ 5‬ﺧﻄﻮﺍﺕ ﺛﺎﻧﻴﺔ‪ .‬ﻋﻨﺪﻣﺎ ﻳﺘﻢ‬
‫ﺍﻟﻤﺤﺴﻮﺑﺔﺗﻠﻘﺎﺉﻴﺎً‪ .‬ﻋﻨﺪﻣﺎ ﻳﻜﻮﻥ "‪"OFF‬ﻳﺠﺐ‬
‫ﺗﺸﻐﻴﻞﺃﻭ ﺇﻳﻘﺎﻑ ﺗﺸﻐﻴﻞ ﻣﺮﺣﻠﺔ ﻣﻜﺜﻒ ‪ ،‬ﻳﻨﺘﻈﺮ‬
‫ﺑﺮﻣﺠﺔﻗﻴﻤﺔ ‪ c / k‬ﻳﺪﻭﻳﺎً )ﺿﻤﻦ ﻭﺿﻊ ﺍﻟﺒﺮﻧﺎﻣﺞ ‪(6‬‬
‫ﻣﺮﺣﻞﺍﻟﺘﺤﻜﻢ ﺗﺄﺧﻴﺮ ﻭﻗﺖ ﺍﻟﺘﺒﺪﻳﻞ ﻗﺒﻞ ﺃﻥ ﺗﺘﻢ ﻋﻤﻠﻴﺔ‬
‫ﻭﻓﻘﺎًﻟﻠﺠﺪﻭﻝ ‪ 3‬ﻓﻲ ﺍﻟﺼﻔﺤﺔ ‪ 24‬ﺃﻭ ﻭﻓﻘﺎً ﻟﻠﻤﻌﺎﺩﻟﺔ ‪.1‬‬
‫ﺍﻟﺘﺒﺪﻳﻞ‪.‬ﺇﺫﺍ ﻛﺎﻧﺖ ﻫﻨﺎﻙ ﺣﺎﺟﺔ ﺇﻟﻰ ﻣﺰﻳﺪ ﻣﻦ‬
‫ﻛﻤﺎﻳﺠﺐ ﺇﺩﺧﺎﻝ ﺃﻭﺿﺎﻉ ﺍﻟﺒﺮﻧﺎﻣﺞ ‪) 7‬ﺗﺴﻠﺴﻞ ﺍﻟﺘﺒﺪﻳﻞ(‬
‫ﺍﻟﻤﺮﺍﺣﻞ ‪،‬ﻳﺘﻢ ﺗﻘﺼﻴﺮ ﻭﻗﺖ ﺍﻟﺘﺒﺪﻳﻞ ﻭﻓﻘﺎً ﻟﻌﺪﺩ‬
‫ﻭ‪) 8‬ﻋﺪﺩ ﺍﻟﻤﻮﺻﻼﺕ ﺍﻟﻤﺴﺘﺨﺪﻣﺔ( ﻳﺪﻭﻳﺎً ‪.‬‬
‫ﺍﻟﻤﺮﺍﺣﻞﺍﻟﻤﻄﻠﻮﺑﺔ‪.‬‬

‫‪22‬‬
‫‪5.6‬ﺍﻻﺳﺘﺠﺎﺑﺔ ﺍﻟﺤﺎﻟﻴﺔ )ﺝ ‪ /‬ﻙ(‬
‫ﻋﻨﺪﺿﺒﻂ ﺍﻟﺘﺤﺪﻳﺪ ﺍﻟﺘﻠﻘﺎﺉﻲ ﻟﺘﻴﺎﺭ ﺍﻟﻤﺮﺣﻠﺔ ﻋﻠﻰ‬ ‫ﻳﺤﺴﺐﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ‪ RM 9606‬ﺧﺎﺻﻴﺔ ﺍﻟﺘﺤﻜﻢ‬
‫"‪ ، "OFF‬ﻳﻤﻜﻦ ﺿﺒﻂ ﺗﻴﺎﺭ ﺍﻻﺳﺘﺠﺎﺑﺔ ﺑﻴﻦ ‪ 0.02‬ﻭ‬ ‫ﻣﻦﻋﺎﻣﻞ ﺍﻟﻘﺪﺭﺓ ﻭﺍﻟﺘﺤﻮﻝ ﺍﻟﻤﺘﻮﺍﺯﻱ ﻭﺍﻟﻘﻴﻮﺩ )ﻓﻲ‬
‫‪ A2.0‬ﻓﻲ ﺧﻄﻮﺍﺕ ‪ .A 0.01‬ﻳﻤﻜﻦ ﺃﺧﺬ ﺍﻹﻋﺪﺍﺩ‬ ‫ﺍﻟﺸﻜﻞ‪ 4‬ﺇﻟﻰ ﺍﻟﺸﻜﻞ ‪ 10‬ﺍﻟﻤﻮﺿﺢ ﻛﺨﻂ ﻣﻨﻘﻂ( ﻭﻟﻪ‬
‫ﺍﻟﺼﺤﻴﺢﻟﻨﻈﺎﻡ ﺟﻬﺪ ‪ 400‬ﻓﻮﻟﺖ ﻭﻣﺤﻮﻝ ﺗﻴﺎﺭ ﺑﺘﻴﺎﺭ‬ ‫ﻧﻄﺎﻕﺗﻔﺎﻭﺕ ﻳﺒﻠﻎ ‪ 0.65‬ﻣﺮﺓ ﺃﺻﻐﺮ ﻣﺮﺣﻠﺔ ﻓﻲ‬
‫ﺛﺎﻧﻮﻱ‪ 5A‬ﻣﻦ ﺍﻟﺠﺪﻭﻝ ‪.3‬‬ ‫ﺍﻻﺳﺘﻘﺮﺍءﻭﻛﺬﻟﻚ ﻓﻲ ﺍﻻﺗﺠﺎﻩ ﺍﻟﺴﻌﻮﻱ )ﻣﻠﺤﻮﻅ ﺑﺨﻂ‬
‫ﻋﺮﻳﺾ(‪ .‬ﻳﺤﻘﻖ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻧﻄﺎﻕ ﺍﻟﺘﺤﻜﻢ ﻫﺬﺍ‬
‫ﺑﺎﺳﺘﻤﺮﺍﺭﻋﻦ ﻃﺮﻳﻖ ﺍﻟﺘﺸﻐﻴﻞ ﻭﺇﻳﻘﺎﻑ ﺍﻟﺘﺸﻐﻴﻞ‬
‫ﻓﻲﺣﺎﻟﺔ ﺍﻟﻔﻮﻟﺘﻴﺔ ﺍﻷﺧﺮﻯ ﺃﻭ ﺍﻟﻤﺤﻮﻻﺕ ﺍﻟﺤﺎﻟﻴﺔ ﺍﻟﺘﻲ‬ ‫ﺑﺸﻜﻞﻣﻨﻬﺠﻲ‪ .‬ﻣﻦ ﺍﻟﻤﻔﺘﺮﺽ ﺃﻥ ﺗﻜﻮﻥ ﻣﺮﺍﺣﻞ‬
‫ﻟﻢﻳﺘﻢ ﺇﻋﻄﺎء ﺍﻟﺘﻴﺎﺭ ﺍﻷﺳﺎﺳﻲ ﺃﻭ ﺍﻟﺜﺎﻧﻮﻱ ﻟﻬﺎ ‪ ،‬ﻳﻤﻜﻦ‬ ‫ﺍﻟﻤﻜﺜﻔﺎﺕﺍﻟﻤﺘﺼﻠﺔ ﺫﺍﺕ ﺃﺑﻌﺎﺩ ﻛﺎﻓﻴﺔ‪.‬‬
‫ﺣﺴﺎﺏﺗﻴﺎﺭ ﺍﻻﺳﺘﺠﺎﺑﺔ ﻣﻦ ﺍﻟﻤﻌﺎﺩﻟﺔ ﺍﻟﻌﺎﻣﺔ‪:‬‬

‫ﻳﺘﻮﺍﻓﻖﺗﻴﺎﺭ ﺍﻻﺳﺘﺠﺎﺑﺔ ﻣﻊ ﻧﺼﻒ ﻋﺮﺽ ﻧﻄﺎﻕ‬


‫ﺍﻟﻤﻌﺎﺩﻟﺔ‪:1‬‬
‫ﺍﻟﺘﺴﺎﻣﺢ ‪،‬ﻭﺍﻟﺬﻱ ﻳﻤﻜﻦ ﺃﻥ ﻳﺘﻐﻴﺮ ﻓﻴﻪ ﺍﻟﺘﻴﺎﺭ ﺍﻟﺘﻔﺎﻋﻠﻲ‬
‫ﺱ‬ ‫ﺱ‬
‫≈‪×0.375‬‬ ‫ﺝ‪/‬ﻙ=‪×0.65‬‬ ‫ﺩﻭﻥﺗﺸﻐﻴﻞ ﺃﻭ ﺇﻳﻘﺎﻑ ﺗﺸﻐﻴﻞ ﻣﺮﺍﺣﻞ ﺍﻟﻤﻜﺜﻒ‪.‬‬
‫ﻳﻮ×ﻙ‬ ‫ﻳﻮ×‪×3‬ﻙ‬

‫ﺝ ‪ /‬ﻙ=ﺗﻴﺎﺭ ﺍﻻﺳﺘﺠﺎﺑﺔ )ﺃﻣﺒﻴﺮ( ﻟﻴﺘﻢ ﺿﺒﻄﻪ ﺱ=‬ ‫ﻫﺬﺍﺿﺮﻭﺭﻱ ﻟﻀﻤﺎﻥ ﻋﺪﻡ ﺗﺄﺭﺟﺢ ﺍﻟﻨﻈﺎﻡ‪ .‬ﻳﺘﻢ ﺗﺤﺪﻳﺪ‬
‫ﺗﺼﻨﻴﻒﺍﻟﻤﺮﺣﻠﺔ ﻣﻜﺜﻒ ﻓﻲ ‪ var‬ﻣﻦ ﺃﺻﻐﺮ‬ ‫ﺍﻟﻌﺮﺽﺍﻹﺟﻤﺎﻟﻲ ﻟﺸﺮﻳﻂ ﺍﻟﺘﺴﺎﻣﺢ ﺑﻄﺮﻳﻘﺔ ﺗﺘﻮﺍﻓﻖ‬
‫ﻣﺮﺣﻠﺔ)ﻟﻴﺲ ﺍﻟﻨﻈﺎﻡ ﺍﻟﻜﺎﻣﻞ(‬ ‫ﻣﻊﺗﻘﺮﻳﺒﺎً‪ 1.3 .‬ﺿﻌﻒ ﺍﻟﺘﻴﺎﺭ ﺍﻟﺘﻔﺎﻋﻠﻲ ﻷﺻﻐﺮ ﻣﺮﺣﻠﺔ‬
‫ﻣﻜﺜﻒ‪.‬‬
‫ﺟﻬﺪﺍﻟﺘﻴﺎﺭ ﺍﻟﻜﻬﺮﺑﺎﺉﻲ )‪ (V‬ﻋﻠﻰ ﺍﻟﺠﺎﻧﺐ ﺍﻷﺳﺎﺳﻲ‬ ‫ﻳﻮ=‬
‫ﻣﻦﺍﻟﻤﺤﻮﻝ ﺍﻟﺤﺎﻟﻲ‬
‫ﻧﺴﺒﺔﺍﻟﻤﺤﻮﻻﺕ‬ ‫ﻙ=‬
‫)ﺍﻟﺘﻴﺎﺭ ﺍﻻﺑﺘﺪﺍﺉﻲ ‪ /‬ﺍﻟﺜﺎﻧﻮﻱ(‬

‫‪23‬‬
‫ﺍﻟﺠﺪﻭﻝ‪:3‬ﺗﻴﺎﺭ ﺍﻻﺳﺘﺠﺎﺑﺔ ﺑﺠﻬﺪ ﺭﺉﻴﺴﻲ ‪ 400‬ﻓﻮﻟﺖ )ﻗﻴﻤﺔ ‪(c / k‬‬

‫∽‬ ‫ﺗﻌﺪﻳﻞ‪ c / k‬ﻟﺠﻬﺪ ﺍﻟﺘﻴﺎﺭ ﺍﻟﻜﻬﺮﺑﺎﺉﻲ ‪ 400‬ﻓﻮﻟﺖ ﺗﻴﺎﺭ ﻣﺘﺮﺩﺩ ‪،‬‬


‫)ﻟﻴﺲ ﺇﺟﻤﺎﻟﻲ ﺍﻟﺘﻘﻴﻴﻢ(ﻓﻲ ﻛﻔﺎﺭ‬ ‫‪50‬ﻫﺮﺗﺰ ﺗﺼﻨﻴﻒ ﺍﻟﻤﺮﺣﻠﺔ ﻷﺻﻐﺮ ﺑﻨﻚ ﻣﻜﺜﻒ‬ ‫ﺗﻴﺎﺭ‬
‫ﻣﺤﻮﻝ‬
‫‪100‬‬ ‫‪60 50 40 30 25 20 15 12،5 10 7،56،25‬‬ ‫‪5‬‬ ‫ﺃ ‪ /‬ﺃ ‪2،5‬‬
‫‪1،60‬‬ ‫‪1،20‬‬ ‫‪0،98‬‬ ‫‪0،80‬‬ ‫‪0،40‬‬ ‫‪30/5‬‬
‫‪1،50‬‬ ‫‪1،20‬‬ ‫‪0،90‬‬ ‫‪0،74‬‬ ‫‪0،60‬‬ ‫‪0،30‬‬ ‫‪40/5‬‬
‫‪1،44‬‬ ‫‪1،20‬‬ ‫‪0،96‬‬ ‫‪0،72‬‬ ‫‪0،59‬‬ ‫‪0،48‬‬ ‫‪0،24‬‬ ‫‪50/5‬‬
‫‪1،60‬‬ ‫‪1،20‬‬ ‫‪1،00‬‬ ‫‪0،80‬‬ ‫‪0،60‬‬ ‫‪0،49‬‬ ‫‪0،40‬‬ ‫‪0،20‬‬ ‫‪60/5‬‬
‫‪1،92‬‬ ‫‪1،60‬‬ ‫‪1،28‬‬ ‫‪0،96‬‬ ‫‪0،80‬‬ ‫‪0،64‬‬ ‫‪0،48‬‬ ‫‪0،39‬‬ ‫‪0،32‬‬ ‫‪0،16‬‬ ‫‪75/5‬‬
‫‪1،92‬‬ ‫‪1،44‬‬ ‫‪1،20‬‬ ‫‪0،96‬‬ ‫‪0،72‬‬ ‫‪0،60‬‬ ‫‪0،48‬‬ ‫‪0،36‬‬ ‫‪0،30‬‬ ‫‪0،24‬‬ ‫‪0،12‬‬ ‫‪100/5‬‬
‫‪1،92‬‬ ‫‪1،60‬‬ ‫‪1،28‬‬ ‫‪0،96‬‬ ‫‪0،80‬‬ ‫‪0،64‬‬ ‫‪0،48‬‬ ‫‪0،40‬‬ ‫‪0،32‬‬ ‫‪0،24‬‬ ‫‪0،20‬‬ ‫‪0،16‬‬ ‫‪0،08‬‬ ‫‪150/5‬‬
‫‪1،44‬‬ ‫‪1،20‬‬ ‫‪0،96‬‬ ‫‪0،72‬‬ ‫‪0،60‬‬ ‫‪0،48‬‬ ‫‪0،36‬‬ ‫‪0،30‬‬ ‫‪0،24‬‬ ‫‪0،18‬‬ ‫‪0،15‬‬ ‫‪0،12‬‬ ‫‪0،06‬‬ ‫‪200/5‬‬
‫‪1،92‬‬ ‫‪1،15‬‬ ‫‪0،96‬‬ ‫‪0،77‬‬ ‫‪0،58‬‬ ‫‪0،48‬‬ ‫‪0،38‬‬ ‫‪0،29‬‬ ‫‪0،24‬‬ ‫‪0،19‬‬ ‫‪0،14‬‬ ‫‪0،12‬‬ ‫‪0،10‬‬ ‫‪0،05‬‬ ‫‪250/5‬‬
‫‪1،60‬‬ ‫‪0،96‬‬ ‫‪0،80‬‬ ‫‪0،64‬‬ ‫‪0،48‬‬ ‫‪0،40‬‬ ‫‪0،32‬‬ ‫‪0،24‬‬ ‫‪0،20‬‬ ‫‪0،16‬‬ ‫‪0،12‬‬ ‫‪0،10‬‬ ‫‪0،08‬‬ ‫‪0،04‬‬ ‫‪300/5‬‬
‫‪1،20‬‬ ‫‪0،72‬‬ ‫‪0،60‬‬ ‫‪0،48‬‬ ‫‪0،36‬‬ ‫‪0،30‬‬ ‫‪0،24‬‬ ‫‪0،18‬‬ ‫‪0،15‬‬ ‫‪0،12‬‬ ‫‪0،09‬‬ ‫‪0،08‬‬ ‫‪0،06‬‬ ‫‪0،03‬‬ ‫‪400/5‬‬
‫‪0،96‬‬ ‫‪0،58‬‬ ‫‪0،48‬‬ ‫‪0،38‬‬ ‫‪0،29‬‬ ‫‪0،24‬‬ ‫‪0،19‬‬ ‫‪0،14‬‬ ‫‪0،12‬‬ ‫‪0،10‬‬ ‫‪0،07‬‬ ‫‪0،06‬‬ ‫‪0،05‬‬ ‫‪0،02‬‬ ‫‪500/5‬‬
‫‪0،80‬‬ ‫‪0،48‬‬ ‫‪0،40‬‬ ‫‪0،32‬‬ ‫‪0،24‬‬ ‫‪0،20‬‬ ‫‪0،16‬‬ ‫‪0،12‬‬ ‫‪0،10‬‬ ‫‪0،08‬‬ ‫‪0،06‬‬ ‫‪0،05‬‬ ‫‪0،04‬‬ ‫‪600/5‬‬
‫‪0،64‬‬ ‫‪0،38‬‬ ‫‪0،32‬‬ ‫‪0،26‬‬ ‫‪0،19‬‬ ‫‪0،16‬‬ ‫‪0،13‬‬ ‫‪0،10‬‬ ‫‪0،08‬‬ ‫‪0،06‬‬ ‫‪0،05‬‬ ‫‪0،04‬‬ ‫‪0،03‬‬ ‫‪750/5‬‬
‫‪0،48‬‬ ‫‪0،29‬‬ ‫‪0،24‬‬ ‫‪0،19‬‬ ‫‪0،14‬‬ ‫‪0،12‬‬ ‫‪0،10‬‬ ‫‪0،07‬‬ ‫‪0،06‬‬ ‫‪0،05‬‬ ‫‪0،04‬‬ ‫‪0،03‬‬ ‫‪0،02‬‬ ‫‪1000/5‬‬
‫‪0،32‬‬ ‫‪0،19‬‬ ‫‪0،16‬‬ ‫‪0،13‬‬ ‫‪0،10‬‬ ‫‪0،08‬‬ ‫‪0،06‬‬ ‫‪0،05‬‬ ‫‪0،04‬‬ ‫‪0،03‬‬ ‫‪0،02‬‬ ‫‪0،02‬‬ ‫‪1500/5‬‬
‫‪0،24‬‬ ‫‪0،14‬‬ ‫‪0،12‬‬ ‫‪0،10‬‬ ‫‪0،07‬‬ ‫‪0،06‬‬ ‫‪0،05‬‬ ‫‪0،04‬‬ ‫‪0،03‬‬ ‫‪0،02‬‬ ‫‪2000/5‬‬
‫‪0،19‬‬ ‫‪0،12‬‬ ‫‪0،10‬‬ ‫‪0،08‬‬ ‫‪0،06‬‬ ‫‪0،05‬‬ ‫‪0،04‬‬ ‫‪0،03‬‬ ‫‪0،02‬‬ ‫‪2500/5‬‬
‫‪0،16‬‬ ‫‪0،10‬‬ ‫‪0،08‬‬ ‫‪0،06‬‬ ‫‪0،05‬‬ ‫‪0،04‬‬ ‫‪0،03‬‬ ‫‪0،02‬‬ ‫‪3000/5‬‬
‫‪0،12‬‬ ‫‪0،07‬‬ ‫‪0،06‬‬ ‫‪0،05‬‬ ‫‪0،04‬‬ ‫‪0،03‬‬ ‫‪0،02‬‬ ‫‪4000/5‬‬
‫‪0،10‬‬ ‫‪0،06‬‬ ‫‪0،05‬‬ ‫‪0،04‬‬ ‫‪0،03‬‬ ‫‪0،02‬‬ ‫‪5000/5‬‬
‫‪0،08‬‬ ‫‪0،05‬‬ ‫‪0،04‬‬ ‫‪0،03‬‬ ‫‪0،02‬‬ ‫‪6000/5‬‬

‫ﺇﺫﺍﻛﺎﻥ ﺣﺠﻢ ﺍﻟﻤﺮﺣﻠﺔ ﺃﻭ ﺍﻟﻤﺤﻮﻝ ﺍﻟﺤﺎﻟﻲ ﺃﻭ ﺍﻟﺘﻴﺎﺭ ﺍﻟﻤﻘﺪﺭ ﻟﻨﻈﺎﻡ ﺍﻟﺘﺤﻜﻢ ﻻ ﻳﻔﻲ ﺑﺎﻟﻘﻴﻢ ﺍﻟﻤﻮﺿﺤﺔ ﻓﻲ ﺍﻟﺠﺪﻭﻝ‬
‫ﺃﻋﻼﻩ ‪،‬ﻓﻴﺠﺐ ﺗﻄﺒﻴﻖ ﺍﻟﻤﻌﺎﺩﻟﺔ ﺍﻟﻤﻮﺟﻮﺩﺓ ﻓﻲ ﺍﻟﺼﻔﺤﺔ ‪ 23‬ﻟﺘﺤﺪﻳﺪ ﻗﻴﻤﺔ ‪.c / k‬‬

‫‪24‬‬
‫‪5.8‬ﻋﺪﺩ ﺍﻟﻤﻼﻣﺴﺎﺕ ﺍﻟﻤﺴﺘﺨﺪﻣﺔ‬ ‫‪5.7‬ﺗﺒﺪﻳﻞ ﺍﻟﺘﺴﻠﺴﻞ‬
‫ﻋﻨﺪﺇﻳﻘﺎﻑ ﺗﺸﻐﻴﻞ ﺗﻌﺮﻳﻒ ‪ c / k‬ﺍﻟﺘﻠﻘﺎﺉﻲ ‪ ،‬ﻳﻤﻜﻦ‬ ‫ﻋﻨﺪﺗﺸﻐﻴﻞ ﺗﺤﺪﻳﺪ ‪ c / k‬ﺍﻟﺘﻠﻘﺎﺉﻲ ‪ ،‬ﻳﻜﻮﻥ ﻛﻞ‬
‫ﺑﺮﻣﺠﺔﺃﻱ ﻗﻴﻤﺔ ﺑﻴﻦ ‪ 1‬ﻭ ‪ .6‬ﻋﻠﻰ ﺳﺒﻴﻞ ﺍﻟﻤﺜﺎﻝ ‪ ،‬ﺇﺫﺍ‬ ‫ﺗﺴﻠﺴﻞﺗﺤﻮﻳﻞ ﺍﺧﺘﻴﺎﺭﻱ ﻣﻤﻜﻨﺎً‪.‬‬
‫ﻛﺎﻧﺖﻫﻨﺎﻙ ﺧﻤﺲ ﻣﺮﺍﺣﻞ ﻓﻲ ﺑﻨﻚ ﻣﻜﺜﻒ ‪ ،‬ﻓﺈﻥ‬
‫ﻫﺬﻩﺍﻟﻤﺮﺍﺣﻞ ﻣﺮﺗﺒﻄﺔ ﺑﻤﺨﺮﺟﺎﺕ ﺍﻟﺘﺤﻜﻢ ﻣﻦ "‪ "1‬ﺇﻟﻰ‬ ‫ﺷﺮﻁﺿﺮﻭﺭﻱ‪ :‬ﻋﻨﺪﻣﺎ ﻳﺘﻢ ﻓﺮﺯ ﻣﺠﻤﻮﻋﺎﺕ ﺍﻟﺘﺒﺪﻳﻞ‬
‫"‪ "5‬ﻭﻳﺘﻢ ﺑﺮﻣﺠﺔ ﻋﺪﺩ ﻣﺨﺮﺟﺎﺕ ﺍﻟﺘﺤﻜﻢ ﻋﻠﻰ "‪ "5‬ﻣﻦ‬ ‫ﺍﻻﺧﺘﻴﺎﺭﻳﺔﻭﻓﻘﺎً ﻟﺴﻌﺘﻬﺎ ‪ ،‬ﻓﺈﻥ ﻓﺮﻕ ﺍﻟﺴﻌﺔ ﺑﻴﻦ‬
‫ﺃﺟﻞﻣﻨﻊ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻣﻦ ﺗﻔﻌﻴﻞ ﻣﺨﺮﺟﺎﺕ ﺍﻟﺘﺤﻜﻢ‬ ‫ﻣﺠﻤﻮﻋﺘﻴﻦﻣﺘﺘﺎﻟﻴﺘﻴﻦ ﻗﺪ ﻻ ﻳﺘﺠﺎﻭﺯ ‪ 1.2‬ﺿﻌﻒ ﺳﻌﺔ‬
‫ﺍﻟﺘﻲﻟﻢ ﻳﺘﻢ ﺗﻮﺻﻴﻠﻬﺎ‪.‬‬ ‫ﺃﺻﻐﺮﻣﺮﺣﻠﺔ‪.‬‬

‫ﺇﺫﺍﺗﻢ ﺇﻳﻘﺎﻑ ﺗﺸﻐﻴﻞ ﺗﺤﺪﻳﺪ ‪ c / k‬ﺍﻟﺘﻠﻘﺎﺉﻲ ‪،‬‬


‫ﻻﻳﺆﺛﺮ ﺣﺠﻢ ﻣﺮﺍﺣﻞ ﺍﻟﻤﻜﺜﻒ ﻋﻠﻰ ﻫﺬﺍ ﺍﻹﻋﺪﺍﺩ‪.‬‬ ‫ﻓﻴﻤﻜﻦﺇﻋﺎﺩﺓ ﺗﻌﻴﻴﻦ ﺗﺴﻠﺴﻞ ﺍﻟﺘﺒﺪﻳﻞ )ﺑﺮﻧﺎﻣﺞ ﺍﻟﺘﺒﺪﻳﻞ‬
‫( ﺇﻟﻰ ﺍﻟﻤﺠﻤﻮﻋﺎﺕ ﺍﻟﺘﺎﻟﻴﺔ ﻟﻤﺮﺍﺣﻞ ﺍﻟﻤﻜﺜﻒ‪:‬‬

‫‪5.9‬ﺗﺤﺪﻳﺪ ﺍﻟﻤﺮﺍﺣﻞ ﺍﻟﺜﺎﺑﺘﺔ‬


‫ﻳﺴﻤﺢﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ‪ RM 9606‬ﺑﻤﻌﺎﻟﺠﺔ ﻣﺨﺮﺟﺎﺕ‬ ‫‪4 :4 :4 :3 :2:1‬‬ ‫‪4 :4 :4 :2 :1:1‬‬ ‫‪1 :1 :1 :1 :1:1‬‬
‫ﺍﻟﺘﺤﻜﻢﺍﻟﺜﻼﺛﺔ ﺍﻷﻭﻟﻰ ﻛﻤﺮﺍﺣﻞ ﺛﺎﺑﺘﺔ‪ .‬ﺍﻟﻤﺮﺍﺣﻞ ﺍﻟﺜﺎﺑﺘﺔ‬ ‫‪6 :6 :6 :3 :2:1‬‬ ‫‪8 :8 :4 :2 :1:1‬‬ ‫‪2 :2 :2 :2 :1:1‬‬
‫ﻫﻲﻣﺮﺍﺣﻞ ﻻ ﻳﺘﻢ ﺗﻀﻤﻴﻨﻬﺎ ﻓﻲ ﺩﻭﺭﺓ ﺍﻟﺘﺤﻜﻢ ﺍﻟﻌﺎﺩﻳﺔ‬ ‫‪4 :4 :4 :4 :2:1‬‬ ‫‪2 :2 :2 :2 :2:1‬‬ ‫‪4 :4 :2 :2 :1:1‬‬
‫ﻭﻟﻜﻦﻳﺘﻢ ﺗﺸﻐﻴﻠﻬﺎ ﻓﻮﺭﺍً ﺑﻌﺪ ﺗﺸﻐﻴﻞ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ‬ ‫‪8 :8 :8 :4 :2:1‬‬ ‫‪3 :3 :3 :3 :2:1‬‬ ‫‪3 :3 :3 :2 :1:1‬‬
‫ﻭﺗﻈﻞﺩﺍﺉﻤﺎً ﻗﻴﺪ ﺍﻟﺘﺸﻐﻴﻞ‪ .‬ﻳﺘﻢ ﺍﻟﺤﻔﺎﻅ ﻋﻠﻰ ﻓﺘﺮﺓ‬ ‫ﺃﺻﻐﺮﻣﺮﺣﻠﺔ ﻟﻠﻤﻜﺜﻒ ﻫﻲ ﺩﺍﺉﻤﺎً "‪ ، "1‬ﻭﺍﻟﻤﺮﺍﺣﻞ‬
‫ﺍﻟﺘﻔﺮﻳﻎﺍﻟﻤﺤﺪﺩﺓ‪ .‬ﺗﻢ ﺗﺠﺎﻫﻞ ﺇﻋﺪﺍﺩ ﻋﺎﻣﻞ ﺍﻟﻄﺎﻗﺔ‬ ‫ﺍﻟﻼﺣﻘﺔﺇﻣﺎ ﻫﻲ ﻧﻔﺴﻬﺎ )‪ (... 1 :1 :1‬ﺃﻭ ﺃﻛﺒﺮ‪ .‬ﻓﻲ‬
‫ﺍﻟﻬﺪﻑ‪.‬‬ ‫ﺍﻟﺴﻄﺮﺍﻟﺜﺎﻧﻲ ﺃﻋﻼﻩ ‪ ،‬ﻳﻤﻜﻦ ﺗﺤﻘﻴﻖ ﻧﺘﻴﺠﺔ ﺃﻛﺜﺮ ﺩﻗﺔ‬
‫ﺑﻨﻔﺲﻋﺪﺩ ﺗﺒﺪﻳﻞ ﺍﻟﻤﻮﺻﻼﺕ‪.‬‬

‫ﺍﻹﻋﺪﺍﺩﺍﺕﺍﻟﺘﺎﻟﻴﺔ ﻣﻤﻜﻨﺔ‪:‬‬
‫= ﻻ ﺗﻮﺟﺪ ﻣﺮﺍﺣﻞ ﺛﺎﺑﺘﺔ‬ ‫‪0‬‬ ‫ﻋﻨﺪﺇﻳﻘﺎﻑ ﺗﺸﻐﻴﻞ ﺗﺤﺪﻳﺪ ‪ c / k‬ﺍﻟﺘﻠﻘﺎﺉﻲ ‪ ،‬ﻳﺠﺐ‬
‫= ﺧﺮﺝ ﺍﻟﺘﺤﻜﻢ ‪ 1‬ﺛﺎﺑﺖ‬ ‫‪1‬‬ ‫ﺗﻮﺻﻴﻞﺃﺻﻐﺮ ﻣﺮﺣﻠﺔ ﻣﻜﺜﻒ )"‪ ("1‬ﺑﻤﺨﺮﺝ ﺍﻟﺘﺤﻜﻢ‬
‫= ﻣﺨﺮﺟﺎﺕ ﺍﻟﺘﺤﻜﻢ ‪ 1‬ﻭ ‪ 2‬ﺛﺎﺑﺘﺔ =‬ ‫‪2‬‬ ‫ﺍﻷﻭﻝﻟﻄﺮﻑ ﺍﻟﺘﻮﺻﻴﻞ‪ .‬ﺗﺘﺒﻊ ﺟﻤﻴﻊ ﺍﻟﻤﺮﺍﺣﻞ ﺍﻷﺧﺮﻯ‬
‫ﻣﺨﺮﺟﺎﺕﺍﻟﺘﺤﻜﻢ ﻣﻦ ‪ 1‬ﺇﻟﻰ ‪ 3‬ﺛﺎﺑﺘﺔ‬ ‫‪3‬‬ ‫ﺣﺴﺐﻗﺪﺭﺗﻬﺎ‪ .‬ﻓﻲ ﺣﺎﻟﺔ ﺍﺳﺘﺨﺪﺍﻡ ﺍﻟﻤﺮﺍﺣﻞ ﺍﻟﺜﺎﺑﺘﺔ ‪،‬‬
‫ﻳﺠﺐﺗﻮﺻﻴﻞ ﺃﺻﻐﺮ ﻣﺮﺣﻠﺔ ﺑﻌﺪ ﺁﺧﺮ ﻣﺮﺣﻠﺔ ﺛﺎﺑﺘﺔ‪.‬‬
‫ﺗﺴﻠﺴﻞﺍﻟﺘﺤﻮﻳﻞ ﻻ ﻳﺄﺧﺬ ﻓﻲ ﺍﻻﻋﺘﺒﺎﺭ ﺍﻟﻤﺮﺍﺣﻞ ﺍﻟﺜﺎﺑﺘﺔ‪.‬‬

‫‪25‬‬
‫‪5.13‬ﺿﺒﻂ ﺩﻭﺭﺍﻥ ﺍﻟﺘﺒﺪﻳﻞ ﺍﻟﺪﻭﺭﻱ ‪/‬‬ ‫‪5.10‬ﺗﻌﺮﻳﻒ ﺍﺗﺼﺎﻝ ﺗﺸﻐﻴﻞ ‪ /‬ﺇﻳﻘﺎﻑ‬
‫ﻏﻴﺮﺍﻟﺪﻭﺭﻱ‬
‫ﻣﺮﺣﻞﺍﻟﺘﺤﻜﻢ ﻟﺪﻳﻪ ﻣﻴﺰﺓ ﺗﺤﺪﻳﺪ ﺍﻻﺗﺼﺎﻝ ﺍﻟﺘﻠﻘﺎﺉﻲ‪.‬‬
‫ﻓﻲﺣﺎﻻﺕ ﻣﻌﻴﻨﺔ ﻋﻨﺪﻣﺎ ﺗﻜﻮﻥ ﻫﻨﺎﻙ ﻣﺮﺍﺣﻞ ﻣﻔﻠﺘﺮﺓ‬
‫ﻭﻏﻴﺮﻣﻔﻠﺘﺮﺓ ﺩﺍﺧﻞ ﻧﻈﺎﻡ ﻭﺍﺣﺪ ‪ ،‬ﻣﻦ ﺍﻟﻀﺮﻭﺭﻱ ﺍﻟﺘﺄﻛﺪ‬ ‫)ﺭﺍﺟﻊ ﺍﻟﻘﺴﻢ ‪(2.1‬‬
‫ﻣﻦﺃﻥ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻻ ﻳﻌﻤﻞ ﺑﺸﻜﻞ ﺩﻭﺭﻱ‪ .‬ﺑﺎﻟﻨﺴﺒﺔ‬
‫ﻋﻠﻰ‪:‬ﻳﻤﻜﻦ ﻗﺮﺍءﺓ ﺍﻻﺗﺼﺎﻝ ﺍﻟﺬﻱ ﻳﺘﻌﺮﻑ ﻋﻠﻴﻪ ﻣﺮﺣﻞ‬
‫ﻟﻤﺜﻞﻫﺬﻩ ﺍﻟﺘﻄﺒﻴﻘﺎﺕ ‪ ،‬ﻳﻤﻜﻦ ﺗﻌﻄﻴﻞ ﻫﺬﻩ ﺍﻟﻤﻴﺰﺓ‪.‬‬
‫ﺍﻟﺘﺤﻜﻢﺗﺤﺖ ﺭﻗﻢ ﺍﻟﻮﺿﻊ ‪ -15-‬ﻭﻓﻘﺎً ﻟﻠﺠﺪﻭﻝ ‪) .2‬ﻏﻴﺮ‬
‫ﺩﺍﺧﻞﻭﺧﺎﺭﺝ ﻟﻬﺎ ﺍﻟﻤﻌﺎﻧﻲ ﺍﻟﺘﺎﻟﻴﺔ‪:‬‬
‫ﻗﺎﺑﻞﻟﻠﺘﻐﻴﻴﺮ(‬

‫ﻋﻠﻰ‪:‬ﻋﺪﺩ ﺻﻐﻴﺮ ﻣﻦ ﺍﻟﻤﻔﺎﺗﻴﺢ ‪ ،‬ﻳﺘﻢ ﺗﻤﻜﻴﻦ ﺍﻟﺘﺒﺪﻳﻞ‬


‫ﺇﻳﻘﺎﻑ‪:‬ﻳﺠﺐ ﺑﺮﻣﺠﺔ ﺍﻻﺗﺼﺎﻝ ﻳﺪﻭﻳﺎً ﻭﻓﻘﺎً ﻟﻠﺠﺪﻭﻝ ‪.2‬‬
‫ﺍﻟﺪﻭﺭﻱﻋﻠﻰ ﺟﻤﻴﻊ ﺍﻟﻤﺴﺘﻮﻳﺎﺕ‪.‬‬
‫ﺇﻳﻘﺎﻑ‪:‬ﻻ ﺗﺒﺪﻳﻞ ﺩﻭﺭﻱ ؛ ﻳﺘﻢ ﺗﺸﻐﻴﻞ ﺍﻟﻤﺮﺍﺣﻞ ﺩﺍﺧﻞ‬
‫ﻛﻞﻣﺴﺘﻮﻯ‪.‬‬ ‫‪5.11‬ﻭﺿﻊ ﺍﻻﺗﺼﺎﻝ‬
‫ﻋﺎﺩﺓ ‪،‬ﻳﺠﺐ ﺿﺒﻂ ﻭﺿﻊ ﺍﻻﺗﺼﺎﻝ ﻋﻠﻰ ﺍﻟﺘﺸﻐﻴﻞ‬
‫‪5.14‬ﺿﺒﻂ ﻋﺘﺒﺔ ﺇﻧﺬﺍﺭ ﻋﺪﺩ ﺍﻟﺘﺒﺪﻳﻞ‬
‫ﺍﻟﺘﻠﻘﺎﺉﻲ‪.‬ﻭﻣﻊ ﺫﻟﻚ ‪ ،‬ﺇﺫﺍ ﻓﺸﻞ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻓﻲ‬
‫ﺗﺤﺪﻳﺪﻭﺿﻊ ﺍﻻﺗﺼﺎﻝ ﺑﻌﺪ ‪ 15‬ﺩﻗﻴﻘﺔ ﺑﺴﺒﺐ ﺗﻐﻴﻴﺮﺍﺕ‬
‫ﻣﻦﺃﺟﻞ ﺩﻋﻢ ﺻﻴﺎﻧﺔ ﺍﻟﻮﺣﺪﺓ ‪ ،‬ﻳﻮﻓﺮ ‪ RM 9606‬ﻋﺪﺍﺩﺍً‬ ‫ﺍﻟﺤﻤﻞﺍﻟﻌﺎﻟﻴﺔ ﺃﻭ ﺍﺧﺘﻼﻻﺕ ﺍﻟﻄﻮﺭ ‪ ،‬ﻓﻤﻦ ﺍﻟﻤﻤﻜﻦ‬
‫ﺩﺍﺧﻠﻴﺎًﻟﻜﻞ ﻣﺨﺮﺝ ﺗﺤﻮﻳﻞ‪.‬‬ ‫ﺍﻟﺪﺧﻮﻝﺇﻟﻰ ﻭﺿﻊ ﺍﻻﺗﺼﺎﻝ ﻳﺪﻭﻳﺎً ﻭﻓﻘﺎً ﻟﻠﺠﺪﻭﻝ ‪.2‬‬

‫ﺃﺛﻨﺎءﺍﻟﺘﺸﻐﻴﻞ ﺍﻟﻴﺪﻭﻱ ‪ ،‬ﻳﻤﻜﻦ ﻋﺮﺽ ﺍﻟﻌﺪﺩ ﺍﻟﺤﺎﻟﻲ‬


‫ﻟﻜﻞﻣﺮﺣﻠﺔ‪.‬‬
‫)ﺍﻧﻈﺮ ﺍﻟﻘﺴﻢ ‪.(6.2‬‬ ‫‪5.12‬ﺿﺒﻂ ﻭﻗﺖ ﺗﻔﺮﻳﻎ ﺍﻟﻤﻜﺜﻒ‬
‫ﺇﺫﺍﺗﻢ ﺍﺧﺘﻴﺎﺭ ﺍﻟﺤﺪ ﺍﻷﻗﺼﻰ ﻣﻦ ﺇﺟﺮﺍءﺍﺕ ﺍﻟﺘﺤﻮﻳﻞ ‪،‬‬
‫ﻓﺈﻥﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻳﻌﺮﺽ ﺍﻟﺤﺎﺟﺔ ﺇﻟﻰ ﺍﻟﺼﻴﺎﻧﺔ‪.‬‬ ‫ﻣﻦﺃﺟﻞ ﺍﻟﺘﺄﻛﺪ ﻣﻦ ﺃﻧﻪ ﺑﻌﺪ ﺇﻳﻘﺎﻑ ﺍﻟﺘﺸﻐﻴﻞ ‪ ،‬ﻻ ﻳﺘﻢ‬
‫ﺍﻟﻤﺮﺣﻠﺔﺍﻟﺘﻲ ﺗﺠﺎﻭﺯﺕ ﺍﻟﺤﺪ )ﻋﻠﻰ ﺳﺒﻴﻞ ﺍﻟﻤﺜﺎﻝ "" ﻟـ‬ ‫ﺗﺸﻐﻴﻞﻣﺮﺣﻠﺔ ﺍﻟﻤﻜﺜﻒ ﻣﺮﺓ ﺃﺧﺮﻯ ﻗﺒﻞ ﺗﻔﺮﻳﻎ‬
‫‪4‬ﺍﻟﻌﺎﺷﺮ‬ ‫ﺍﻟﻤﻜﺜﻒﺑﺸﻜﻞ ﻛﺎﻑ ٍ‪ ،‬ﻳﻤﻜﻦ ﺿﺒﻂ ﻭﻗﺖ ﺇﻳﻘﺎﻑ‬
‫ﺍﻟﻤﺮﺣﻠﺔ( ﻋﻠﻰ ﺍﻟﺸﺎﺷﺔ )ﺗﻘﺮﻳﺒﺎً ﻛﻞ ‪ 10‬ﺛﻮﺍﻥ(ٍ‪ .‬ﻓﻲ‬ ‫ﺍﻟﺘﺸﻐﻴﻞﻭﻓﻘﺎً ﻟﻼﺣﺘﻴﺎﺟﺎﺕ ﺍﻟﻤﺤﺪﺩﺓ )ﻭﺿﻊ ﺍﻟﺘﻔﺮﻳﻎ(‪.‬‬
‫ﻧﻔﺲﺍﻟﻮﻗﺖ ﻳﺘﻢ ﺍﻟﺘﻨﺒﻴﻪ‪ .‬ﺗﻢ ﺷﺮﺡ ﻛﻴﻔﻴﺔ ﺇﺧﻤﺎﺩ‬
‫ﺍﻹﻧﺬﺍﺭﻓﻲ ﺍﻟﻘﺴﻢ ‪.5.15‬‬
‫ﻳﻤﻜﻦﺿﺒﻂ ﻭﻗﺖ ﺍﻟﺘﻔﺮﻳﻎ ﺑﻴﻦ ‪ 5‬ﻭ ‪ 900‬ﺛﺎﻧﻴﺔ‪.‬‬

‫‪26‬‬
‫‪5.17‬ﻧﺴﺒﺔ ﻣﺤﻮﻝ ﺍﻟﺠﻬﺪ‬ ‫ﻳﺠﺐﻗﺴﻤﺔ ﺍﻟﻌﺪﺩ ﺍﻟﻤﻄﻠﻮﺏ ﻣﻦ ﺍﻟﻤﻔﺎﺗﻴﺢ ﻋﻠﻰ‬
‫‪1000‬ﻗﺒﻞ ﺇﺩﺧﺎﻟﻬﺎ‪ .‬ﻫﺬﺍ ﻳﻌﻨﻲ ﺃﻥ ﺇﺩﺧﺎﻝ ‪ 100‬ﻳﺜﻴﺮ‬
‫ﺇﺫﺍﺗﻢ ﺍﺳﺘﺨﺪﺍﻡ ﻣﺤﻮﻝ ﺍﻟﺠﻬﺪ ﺩﺍﺧﻞ ﺩﺍﺉﺮﺓ ﺍﻟﻘﻴﺎﺱ ‪،‬‬
‫ﺇﻧﺬﺍﺭﺍًﻋﻨﺪ ‪ 100000‬ﻣﻔﺘﺎﺡ ﻟﻤﺮﺣﻠﺔ ﻭﺍﺣﺪﺓ‪.‬‬
‫ﻓﻴﺠﺐﺇﺩﺧﺎﻝ ﻧﺴﺒﺔ ﻣﺤﻮﻝ ﺍﻟﺠﻬﺪ ﻣﻦ ﺃﺟﻞ ﻗﻴﺎﺱ‬
‫ﻋﺮﺽ‪ kvar‬ﺍﻟﻤﻔﻘﻮﺩ ﻟﻠﻮﺻﻮﻝ ﺇﻟﻰ ﻋﺎﻣﻞ ﺍﻟﻘﺪﺭﺓ‬
‫ﺍﻟﻤﺴﺘﻬﺪﻑﺑﺸﻜﻞ ﺻﺤﻴﺢ‪.‬‬ ‫ﻻﺗﺆﺛﺮ ﺇﺷﺎﺭﺍﺕ ﺇﻧﺬﺍﺭ ﺍﻟﻤﺮﺣﻠﺔ ﻋﻠﻰ ﺳﻠﻮﻙ ‪ /‬ﺃﺩﺍء‬
‫ﺍﻟﺘﺤﻜﻢﻓﻲ ﺍﻟﻤﺮﺣﻞ‪.‬‬
‫ﻳﺘﻢﺗﻌﻴﻴﻦ ﻧﺴﺒﺔ ﻣﺤﻮﻝ ﺍﻟﺠﻬﺪ ﺍﻷﺳﺎﺳﻲ ‪ /‬ﺍﻟﺜﺎﻧﻮﻱ‬
‫ﺑﻴﻦ‪ 1‬ﻭ ‪ .300‬ﻓﻲ ﺣﺎﻟﺔ ﻋﺪﻡ ﻭﺟﻮﺩ ﻣﺤﻮﻝ ﺟﻬﺪ ‪،‬‬
‫ﻳﺠﺐﺇﺩﺧﺎﻝ ﺍﻟﻘﻴﻤﺔ "‪."1‬‬ ‫‪5.15‬ﺇﻋﺎﺩﺓ ﺗﻌﻴﻴﻦ ﻋﺪﺍﺩ ﺍﻟﺘﺤﻮﻳﻞ‬
‫ﻓﻲﺍﻟﻮﺿﻊ ‪ -15-‬ﻳﻤﻜﻦ ﺇﻋﺎﺩﺓ ﺿﺒﻂ ﻋﺪﺍﺩﺍﺕ ﺍﻟﺘﺒﺪﻳﻞ‬
‫ﻛﻠﻴﺎًﺃﻭ ﻣﻨﻔﺼﻼً‪.‬‬
‫‪5.18‬ﺍﻹﻋﺪﺍﺩ ‪5‬ﺍﻟﻌﺎﺷﺮﻋﺘﺒﺔ ﺍﻟﺘﻮﺍﻓﻘﻴﺔ‬
‫ﻋﻨﺪﺍﺧﺘﻴﺎﺭ ﺍﻟﻮﺿﻊ ‪ -15-‬ﺗﻈﻬﺮ ﺍﻟﺸﺎﺷﺔ "‪."0‬‬
‫ﻳﺤﺘﻮﻱ‪ Control Relay RM 9606‬ﻋﻠﻰ ﻧﻈﺎﻡ‬ ‫ﺑﺎﺳﺘﺨﺪﺍﻡﺍﻷﺯﺭﺍﺭ "‪ "+‬ﻭ "‪ "-‬ﻳﻤﻜﻦ ﺍﺧﺘﻴﺎﺭ ﺭﻗﻢ ﺍﻟﻤﺮﺣﻠﺔ‬
‫ﻣﺮﺍﻗﺒﺔﺗﻮﺍﻓﻘﻲ ﻟـ ‪5‬ﺍﻟﻌﺎﺷﺮ‪7 ،‬ﺍﻟﻌﺎﺷﺮ‪11 ،‬ﺍﻟﻌﺎﺷﺮﻭ ‪13‬ﺍﻟﻌﺎﺷﺮ‬ ‫ﺑﻴﻦ‪ 1‬ﻭ ‪ 6‬ﺃﻭ "ﺍﻟﻜﻞ"‪ .‬ﺍﻟﺨﺮﻭﺝ ﻣﻦ ﻗﺴﻢ ﺍﻟﺒﺮﻣﺠﺔ ﻋﻦ‬
‫ﺍﻟﺘﻮﺍﻓﻘﻴﺎﺕ‪.‬ﺇﺫﺍ ﺗﻢ ﺗﺠﺎﻭﺯ ﺍﻟﻘﻴﻤﺔ ﺍﻟﻤﺤﺪﺩﺓ ‪ ،‬ﻓﻬﻨﺎﻙ‬ ‫ﻃﺮﻳﻖﺍﻟﻀﻐﻂ ﻋﻠﻰ ﺯﺭ "‪ "man / set‬ﻳﻌﻴﺪ ﺗﻌﻴﻴﻦ‬
‫ﺇﺷﺎﺭﺓﺇﻧﺬﺍﺭ ‪ ،‬ﺃﻱ ﻳﺘﻢ ﺇﻏﻼﻕ ﺟﻬﺔ ﺍﺗﺼﺎﻝ ﺍﻟﺘﻨﺒﻴﻪ‬ ‫ﻋﺪﺩﺍﻟﻤﺮﺣﻠﺔ ﺍﻟﻤﻌﺮﻭﺿﺔ‪ .‬ﻋﻦ ﻃﺮﻳﻖ ﺗﻌﻴﻴﻦ "ﻛﻞ" ﺗﺘﻢ‬
‫ﻭﻳﻀﻲءﻣﺆﺷﺮ ‪" LED‬ﺍﻟﻤﻨﺒﻪ" ﻃﺎﻟﻤﺎ ﺗﻢ ﺗﺠﺎﻭﺯ ﺍﻟﻘﻴﻤﺔ‬ ‫ﺇﻋﺎﺩﺓﺗﻌﻴﻴﻦ ﺟﻤﻴﻊ ﺍﻟﺘﻬﻢ‪.‬‬
‫ﺍﻟﻤﺤﺪﺩﺓ‪.‬ﻳﻮﻣﺾ ﻣﺆﺷﺮ ‪ "LED "Harmonic‬ﺣﺘﻰ‬
‫ﻳﺘﻢﺇﻃﻔﺎء ﺍﻟﻤﻨﺒﻪ‪ .‬ﻳﺘﻢ ﻋﺮﺽ ﺍﻟﺘﺮﺗﻴﺐ ﻭﺍﻟﻘﻴﻤﺔ‬ ‫ﺇﺫﺍﻛﻨﺖ ﻻ ﺗﺮﻏﺐ ﻓﻲ ﺇﻋﺎﺩﺓ ﺗﻌﻴﻴﻦ ﺃﻱ ﻋﺪﺍﺩ ﻳﺠﺐ‬
‫ﺍﻟﻘﺼﻮﻯﻟﻠﺘﻮﺍﻓﻘﻴﺎﺕ ﺍﻟﺘﻲ ﺗﻢ ﺗﺠﺎﻭﺯﻫﺎ ‪ ،‬ﺑﺪءﺍً ﻣﻦ ﺍﻟﺤﺪ‬ ‫ﺿﺒﻂ"‪ "0‬ﻗﺒﻞ ﺍﻟﻀﻐﻂ ﻋﻠﻰ ﺯﺭ "‪."man / set‬‬
‫ﺍﻷﻗﺼﻰﻟﻼﻧﺤﺮﺍﻑ ‪ ،‬ﺑﺎﻟﻀﻐﻂ ﺍﻟﻤﺘﻌﺪﺩ ﻋﻠﻰ ﺍﻟﺰﺭ "‬
‫ﺗﻌﻴﻴﻦ"‪ .‬ﻳﺠﺐ ﺍﻟﻀﻐﻂ ﻋﻠﻰ ﺯﺭ "‪ "Set‬ﺑﺸﻜﻞ ﻣﺘﻜﺮﺭ‬
‫ﺣﺘﻰﻳﻨﻄﻔﺊ ﻣﺆﺷﺮ ‪."LED "Harmonic‬‬ ‫‪5.16‬ﻧﺴﺒﺔ ﺍﻟﻤﺤﻮﻻﺕ ﺍﻟﺤﺎﻟﻴﺔ )‪(CT‬‬
‫ﻟﻌﺮﺽﺍﻟﺘﻴﺎﺭ ﺍﻟﻨﺸﻂ )‪ (IP‬ﻭﺍﻟﺘﻴﺎﺭ ﺍﻟﺘﻔﺎﻋﻠﻲ )‪(IQ‬‬
‫ﻭﺍﻟﺘﻴﺎﺭﺍﻟﻈﺎﻫﺮ )‪ (IS‬ﻛﻘﻴﻢ ﻓﻌﻠﻴﺔ ‪ ،‬ﻳﺠﺐ ﺇﺩﺧﺎﻝ ﺍﻟﻨﺴﺒﺔ‬
‫ﺑﻴﻦﺍﻟﺘﻴﺎﺭ ﺍﻷﻭﻟﻲ ﻭﺍﻟﺘﻴﺎﺭ ﺍﻟﺜﺎﻧﻮﻱ ﻟﻠﻤﺤﻮﻝ ﺍﻟﺤﺎﻟﻲ‬
‫ﺍﻟﻤﺴﺘﺨﺪﻡ‪.‬ﺇﺫﺍ ﻟﻢ ﻳﺘﻢ ﺗﻌﻴﻴﻦ ﻧﺴﺒﺔ ﺍﻟﻤﺤﻮﻝ ﺍﻟﺤﺎﻟﻲ ‪،‬‬
‫‪5.19‬ﺍﻹﻋﺪﺍﺩ ‪7‬ﺍﻟﻌﺎﺷﺮﻋﺘﺒﺔ ﺍﻟﺘﻮﺍﻓﻘﻴﺔ‬ ‫ﻓﻴﺠﺐﺿﺮﺏ ﺍﻟﻘﻴﻤﺔ ﺍﻟﻤﻌﺮﻭﺿﺔ ﺑﻨﺴﺒﺔ ‪ ، CT‬ﻭﻳﻤﻜﻦ‬
‫ﺇﺩﺧﺎﻝﺍﻟﻘﻴﻢ ﺑﻴﻦ ‪ 1‬ﻭ ‪7000‬‬
‫ﺍﻟﻌﺎﺷﺮ‬ ‫ﺗﺤﺪﻳﺪﺍﻟﻘﻴﻤﺔ ﺍﻟﻤﺤﺪﺩﺓ ﻟـ ‪7‬‬
‫ﻣﺘﻨﺎﺳﻖ‪.‬‬

‫)ﻋﻠﻰ ﺳﺒﻴﻞ ﺍﻟﻤﺜﺎﻝ‪.(200→1000A / 5A .‬‬

‫‪27‬‬
‫‪5.23‬ﻗﻤﻊ ﺇﻧﺬﺍﺭ ﻋﺎﻣﻞ ﺍﻟﻄﺎﻗﺔ‬ ‫‪5.20‬ﺍﻹﻋﺪﺍﺩ ‪11‬ﺍﻟﻌﺎﺷﺮﻋﺘﺒﺔ ﺍﻟﺘﻮﺍﻓﻘﻴﺔ‬
‫ﺍﻟﻌﺎﺷﺮ‬ ‫ﺗﺤﺪﻳﺪﺍﻟﻘﻴﻤﺔ ﺍﻟﻤﺤﺪﺩﺓ ﻟـ ‪11‬‬
‫ﻛﻤﺎﺗﻢ ﻭﺻﻔﻪ ﺑﺎﻟﻔﻌﻞ ‪ ،‬ﻳﺤﺎﻭﻝ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ‬ ‫ﻣﺘﻨﺎﺳﻖ‪.‬‬
‫ﺍﻟﻮﺻﻮﻝﺇﻟﻰ ﻧﻄﺎﻕ ﺍﻟﺘﺤﻜﻢ ﺍﻟﻤﺒﺮﻣﺞ ﺍﻟﺨﺎﺹ ﺑﻪ‪ .‬ﻭﻣﻊ‬
‫ﺫﻟﻚ ‪،‬ﺇﺫﺍ ﻟﻢ ﻳﻜﻦ ﺫﻟﻚ ﻣﻤﻜﻨﺎً ﺑﺴﺒﺐ ﻧﻘﺺ ﻣﺮﺍﺣﻞ‬ ‫‪5.21‬ﺍﻹﻋﺪﺍﺩ ‪13‬ﺍﻟﻌﺎﺷﺮﻋﺘﺒﺔ ﺍﻟﺘﻮﺍﻓﻘﻴﺔ‬
‫ﺍﻟﻤﻜﺜﻒﺍﻟﻤﺘﺎﺣﺔ ‪ ،‬ﻓﺴﻴﺘﻢ ﺇﺻﺪﺍﺭ ﺇﺷﺎﺭﺓ ﺇﻧﺬﺍﺭ ﺑﻌﺪ ﻋﺪﺓ‬
‫ﺍﻟﻌﺎﺷﺮ‬ ‫ﺗﺤﺪﻳﺪﺍﻟﻘﻴﻤﺔ ﺍﻟﻤﺤﺪﺩﺓ ﻟـ ‪13‬‬
‫ﺩﻗﺎﺉﻖ)ﺣﺴﺐ ﺣﺠﻢ ﺍﻻﺧﺘﻼﻑ(‪ .‬ﻓﻲ ﺣﺎﻟﺔ ﻭﺟﻮﺩ ‪-phi‬‬
‫ﻣﺘﻨﺎﺳﻖ‪.‬‬
‫‪ cos‬ﺑﺎﻟﺴﻌﺔ ﺧﺎﺭﺝ ﻧﻄﺎﻕ ﺍﻟﻨﻄﺎﻕ ‪ ،‬ﺗﻌﻤﻞ ﺇﺷﺎﺭﺓ‬
‫ﺍﻹﻧﺬﺍﺭﺃﻳﻀﺎً‪ .‬ﻋﻨﺪ ﺿﺒﻂ "‪ ، "OFF‬ﻳﺘﻢ ﺇﻳﻘﺎﻑ ﺍﻟﻤﻨﺒﻪ‪.‬‬
‫‪5.22‬ﺇﺷﺎﺭﺓ ﺍﻹﻧﺬﺍﺭ ﺍﻟﺘﻮﺍﻓﻘﻴﺔ ﺍﻟﻤﻔﺮﻃﺔ‬
‫ﺍﻟﺘﻴﺎﺭ‬
‫ﻣﺮﺣﻞﺍﻟﺘﺤﻜﻢ ‪ RM 9606‬ﻗﺎﺩﺭ ﻋﻠﻰ ﺗﺤﺪﻳﺪ ﺍﻟﻨﺴﺒﺔ‬
‫ﺑﻴﻦﺗﻴﺎﺭ ‪ RMS‬ﺍﻟﻤﻘﺎﺱ ﺑﺎﻟﻔﻌﻞ ﻭﺍﻟﺘﻴﺎﺭ ﺍﻻﺳﻤﻲ )‬
‫‪5.24‬ﻋﺮﺽ ﺇﺟﻤﺎﻟﻲ ‪kvar‬‬ ‫‪60-50‬ﻫﺮﺗﺰ( ﻟﻠﻤﻜﺜﻒ ‪ ،‬ﺇﺫﺍ ﺗﻢ ﺗﺠﺎﻭﺯ ﻫﺬﻩ ﺍﻟﻨﺴﺒﺔ‬
‫ﺑﻮﺍﺳﻄﺔﺍﻟﻌﺎﻣﻞ ﺍﻟﻤﺤﺪﺩ ﻟﻤﺪﺓ ﺩﻗﻴﻘﺔ ﻭﺍﺣﺪﺓ ﻋﻠﻰ‬
‫ﺑﺸﺮﻁﺇﺩﺧﺎﻝ ﻧﺴﺒﺔ ﺍﻟﻤﺤﻮﻝ ﺍﻟﺤﺎﻟﻲ ‪ ،‬ﺳﻴﻈﻬﺮ ﺇﺟﻤﺎﻟﻲ‬
‫ﺍﻷﻗﻞﺑﺴﺒﺐ ﺍﻟﺘﻮﺍﻓﻘﻴﺎﺕ ﻭ ﻧﺘﻴﺠﺔ ﻇﺎﻫﺮﺓ ﺍﻟﺮﻧﻴﻦ ‪،‬‬
‫‪ kvar‬ﺍﻟﻤﻜﺘﺸﻒ ﻋﻨﺪ ﺍﻟﺠﻬﺪ ﺍﻟﻤﻘﺎﺱ ﻋﻠﻰ ﺍﻟﺸﺎﺷﺔ ‪،‬‬
‫ﻳﻘﻮﻡﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﺑﺈﻳﻘﺎﻑ ﺗﺸﻐﻴﻞ ﺟﻤﻴﻊ ﺍﻟﻤﺮﺍﺣﻞ‬
‫ﻋﻨﺪﺍﻟﻀﻐﻂ ﻋﻠﻰ "‪ "Set‬ﻓﻲ ﺍﻟﻮﺿﻊ‬
‫ﺍﻟﺘﻲﺗﻢ ﺗﺸﻐﻴﻠﻬﺎ‪ .‬ﻓﻲ ﻧﻔﺲ ﺍﻟﻮﻗﺖ ﻳﺘﻢ ﺍﻟﺘﻨﺒﻴﻪ‪ .‬ﺑﻌﺪ‬
‫ﺃﺭﺑﻊﺩﻗﺎﺉﻖ ﺗﻘﺮﻳﺒﺎً ‪ ،‬ﻳﺘﻢ ﺗﺸﻐﻴﻞ ﻣﺮﺍﺣﻞ ﺍﻟﻤﻜﺜﻒ‬
‫‪.-24-‬‬
‫ﺍﻟﻤﻄﻠﻮﺑﺔﻣﺮﺓ ﺃﺧﺮﻯ‪ .‬ﺑﺎﻟﻀﻐﻂ ﻋﻠﻰ ﺯﺭ "‪ ، "Set‬ﻳﺘﻢ‬
‫ﻋﺮﺽﻗﻴﻤﺔ ﺍﻟﺬﺭﻭﺓ‪.‬‬

‫ﻳﻼﺣﻆ‪:‬‬
‫ﻋﻨﺪﺍﺳﺘﺨﺪﺍﻡ ﺍﻟﻤﺮﺍﺣﻞ ﺍﻟﻤﺼﻔﺎﺓ ﺣﺼﺮﻳﺎً ‪ ،‬ﻗﻢ‬
‫ﺑﺘﻌﻴﻴﻦﻫﺬﺍ ﺍﻟﺤﺪ ﻋﻠﻰ ﺃﻋﻠﻰ ﻗﻴﻤﺔ ﻣﻤﻜﻨﺔ )ﻣﻦ‬
‫ﺃﺟﻞﺗﻌﻄﻴﻠﻪ(‪.‬‬

‫‪28‬‬
‫‪.6‬ﺍﻟﻌﻤﻠﻴﺔ‬
‫‪6.1‬ﻃﺮﻕ ﺍﻟﻌﺮﺽ‬
‫ﻓﻲﺣﺎﻟﺔ ﻋﺪﻡ ﻭﺟﻮﺩ ﺗﻐﻴﻴﺮ ﻓﻲ ﺍﻟﺘﻴﺎﺭ ﺍﻟﻤﻘﺎﺱ ‪ ،‬ﻳﺘﻢ‬ ‫ﻋﺮﺽﻋﺎﻣﻞ ﺍﻟﻄﺎﻗﺔ ﻣﺴﺘﻘﻞ ﻋﻦ ﻋﻤﻠﻴﺔ ﻣﺮﺣﻞ‬
‫ﺇﻳﻘﺎﻑﺗﺸﻐﻴﻞ ﺟﻤﻴﻊ ﺍﻟﻤﺮﺍﺣﻞ ﺍﻟﻤﺘﺒﻘﻴﺔ ﻭﻳﻈﻬﺮ "‪= 0‬‬ ‫ﺍﻟﺘﺤﻜﻢﻭﻳﻤﻜﻦ ﺇﻋﺎﺩﺓ ﺑﺮﻣﺠﺘﻪ ﻓﻲ ﺃﻱ ﻭﻗﺖ‪ .‬ﻋﻠﻰ‬
‫‪ "I‬ﻋﻠﻰ ﺍﻟﺸﺎﺷﺔ‪.‬‬ ‫ﻳﻤﻴﻦﺍﻟﺸﺎﺷﺔ ﺍﻟﺮﻗﻤﻴﺔ ﺍﻟﻤﻜﻮﻧﺔ ﻣﻦ ﺃﺭﺑﻌﺔ ﺃﺣﺮﻑ‬
‫ﻭﻧﺼﻒ ‪،‬ﺗﻮﺟﺪ ﺛﻼﺛﺔ ﻣﺼﺎﺑﻴﺢ ‪ LED‬ﺗﺸﻴﺮ ﺇﻟﻰ ﻭﺿﻊ‬
‫ﺍﻟﻌﺮﺽﺍﻟﻨﺸﻂ ‪ ،‬ﺇﻣﺎ "‪ "cos phi‬ﺃﻭ "‪ "Ampere‬ﺃﻭ‬
‫‪6.1.2‬ﺭﺩ ﺍﻟﻔﻌﻞ ﺍﻟﺤﺎﻟﻲ‬ ‫"‪."Harmonic‬‬

‫ﻣﻌﺪﻝﺍﻟﺬﻛﺎء‬

‫ﻳﻤﻜﻦﺗﺤﺪﻳﺪ ﺧﻤﺴﺔ ﺃﻭﺿﺎﻉ ﻟﻠﻌﺮﺽ ﺑﺎﻟﻀﻐﻂ ﻋﻠﻰ‬


‫ﺍﻟﺰﺭﺍﻟﻤﻨﺎﺳﺐ‪:‬‬
‫ﺗﺸﻴﺮﺍﻟﺸﺎﺷﺔ ﺇﻟﻰ ﺍﻟﺠﺰء ﺍﻟﺤﺎﻟﻲ ﺍﻟﺘﻔﺎﻋﻠﻲ ﻓﻲ ﺩﺍﺉﺮﺓ‬
‫ﺍﻟﻤﺤﻮﻻﺕﺍﻟﺤﺎﻟﻴﺔ‪ .‬ﻋﻼﻣﺔ "‪ "+‬ﻟـ ‪ .ind‬ﺃﻭ "‪ "-‬ﻟﻠﻐﻄﺎء‪.‬‬ ‫‪6.1.1‬ﻣﻌﺎﻣﻞ ﺍﻟﻘﺪﺭﺓ‬
‫ﺣﺪﺩﻣﺎ ﺇﺫﺍ ﻛﺎﻥ ﺍﻟﺘﻴﺎﺭ ﺍﻟﺘﻔﺎﻋﻠﻲ ﺣﺜﻴﺎً ﺃﻡ ﺳﻌﻮﻳﺎً‪ .‬ﻳﻀﻲء‬
‫"ﺃﻣﺒﻴﺮ" ‪ .LED‬ﻣﻦ ﻫﺬﺍ ﺍﻟﻮﺿﻊ ﻟﻠﻌﺮﺽ ‪ ،‬ﻳﻤﻜﻦ‬ ‫ﻭﺿﻊﺍﻟﻌﺮﺽ "‪ "Power Factor‬ﻫﻮ ﺍﻟﻌﺮﺽ‬
‫ﻣﺮﺍﻗﺒﺔﺗﺄﺛﻴﺮ ﺍﻟﺘﻌﻮﻳﺾ ﻟﻤﺮﺍﺣﻞ ﺍﻟﻤﻜﺜﻒ ‪ ،‬ﻋﻠﻰ ﺳﺒﻴﻞ‬ ‫ﺍﻟﻘﻴﺎﺳﻲﻭﻳﻤﻜﻦ ﺗﻨﺸﻴﻄﻪ ﻣﻦ ﻭﺿﻊ ﻋﺮﺽ ﺁﺧﺮ‬
‫ﺍﻟﻤﺜﺎﻝﻋﻦ ﻃﺮﻳﻖ ﺇﺿﺎﻓﺔ ﺃﻭ ﺇﺯﺍﻟﺔ ﻣﺮﺍﺣﻞ ﺍﻟﻤﻜﺜﻒ‬ ‫ﺑﺎﻟﻀﻐﻂﻋﻠﻰ ﺍﻷﺯﺭﺍﺭ "‪ "IQ‬ﺃﻭ "‪ "IP‬ﺃﻭ "‪."Harm‬‬
‫ﻳﺪﻭﻳﺎً‪.‬ﺇﺫﺍ ﺗﻤﺖ ﺑﺮﻣﺠﺔ ﻧﺴﺒﺔ ﺍﻟﻤﺤﻮﻝ ﺍﻟﺤﺎﻟﻲ )‪(CT‬‬
‫ﻋﺒﺮﺍﻟﻮﺿﻊ ﺍﻟﻤﺤﺪﺩ ‪ ،‬ﻓﺴﻴﺘﻢ ﻋﺮﺽ ﺍﻟﺘﻴﺎﺭ ﺍﻟﺘﻔﺎﻋﻠﻲ‬ ‫ﺍﻟﺮﻣﻮﺯ"‪ "+‬ﻟـ ‪ .ind‬ﻭ "‪ "-‬ﻟﻠﻐﻄﺎء‪ .‬ﺗﺒﻴﻦ ﻣﺎ ﺇﺫﺍ ﻛﺎﻥ‬
‫ﺍﻟﻔﻌﻠﻲﻋﻠﻰ ﺍﻟﺠﺎﻧﺐ ﺍﻷﺳﺎﺳﻲ ﻣﻦ ‪ .CT‬ﺧﻼﻑ ﺫﻟﻚ ‪،‬‬ ‫ﻋﺎﻣﻞﺍﻟﻘﺪﺭﺓ ﺣﺜﻴﺎً ﺃﻡ ﺳﻌﻮﻳﺎً‪.‬‬
‫ﻳﺘﻢﻋﺮﺽ ﺍﻟﺠﺰء ﺍﻟﺤﺎﻟﻲ ﻭﻳﺠﺐ ﺿﺮﺑﻪ ﻓﻲ ﻧﺴﺒﺔ ‪CT‬‬
‫ﻟﻠﺤﺼﻮﻝﻋﻠﻰ ﺍﻟﻘﻴﻤﺔ ﺍﻟﻔﻌﻠﻴﺔ‪.‬‬ ‫ﻳﺸﻴﺮﻣﺆﺷﺮ ‪ "LED "Regen‬ﺇﻟﻰ ﺇﻋﺎﺩﺓ ﺗﻐﺬﻳﺔ ﺍﻟﻄﺎﻗﺔ‬
‫ﺍﻟﺘﻮﻟﻴﺪﻳﺔﺇﻟﻰ ﺍﻟﺘﻴﺎﺭ ﺍﻟﻜﻬﺮﺑﺎﺉﻲ‪ .‬ﻳﺘﻢ ﻗﻴﺎﺱ ﺍﻟﺘﻴﺎﺭﺍﺕ‬
‫ﺍﻟﻨﺸﻄﺔﻭﺍﻟﻤﺘﻔﺎﻋﻠﺔ ﺑﺸﻜﻞ ﻣﻨﻔﺼﻞ‪ .‬ﻗﻴﻤﺔ ﻋﺮﺽ‬
‫ﻋﺎﻣﻞﺍﻟﻘﺪﺭﺓ )‪ (cos phi‬ﻫﻲ ﻧﺘﻴﺠﺔ ﺣﺴﺎﺏ ﺭﻳﺎﺿﻲ ‪،‬‬
‫ﻭﺍﻟﺬﻱﻳﻀﻤﻦ ﺍﻟﺪﻗﺔ ﻋﻠﻰ ﺍﻟﻨﻄﺎﻕ ﺑﺄﻛﻤﻠﻪ ﻭﺻﻮﻻ ًﺇﻟﻰ‬
‫ﺍﻟﻘﻴﻢﺍﻟﻘﺮﻳﺒﺔ ﻣﻦ ‪ .0‬ﺍﻟﺤﺪ ﺍﻷﺩﻧﻰ ﻟﻠﺘﻴﺎﺭ ﺍﻟﻈﺎﻫﺮﻱ‬
‫ﺍﺿﻐﻂﻋﻠﻰ ﺃﺯﺭﺍﺭ "‪ "IQ‬ﺃﻭ "‪ "IP‬ﺃﻭ "‪ "Harm‬ﻟﻠﺨﺮﻭﺝ‬ ‫ﻟﻌﺮﺽﻋﺎﻣﻞ ﺍﻟﻘﺪﺭﺓ ﺍﻟﺼﺤﻴﺢ )‪ (cos phi‬ﻫﻮ ﺗﻘﺮﻳﺒﺎً‪.‬‬
‫ﻣﻦﻭﺿﻊ ﺍﻟﻌﺮﺽ ﻫﺬﺍ‪.‬‬ ‫‪0.02‬ﺃ‪ .‬ﻋﻨﺪﻣﺎ ﻳﻨﺨﻔﺾ ﺍﻟﺘﻴﺎﺭ ﺍﻟﻈﺎﻫﺮ ﺇﻟﻰ ﺃﻗﻞ ﻣﻦ‬
‫‪0.02‬ﺃ ﻟﺜﻼﺛﺔ ﻗﻴﺎﺳﺎﺕ ﻣﺘﺘﺎﻟﻴﺔ ‪ ،‬ﺗﻜﻮﻥ ﻣﺮﺣﻠﺔ‬
‫ﺍﻟﻤﻜﺜﻒﻭﺍﺣﺪﺓ‬

‫‪29‬‬
‫ﻳﺘﻢﻋﺮﺽ ﺍﻟﺠﺰء ﻭﻳﺠﺐ ﺿﺮﺑﻪ ﻓﻲ ﻧﺴﺒﺔ ‪ CT‬ﻟﻠﺤﺼﻮﻝ‬ ‫‪6.1.3‬ﺍﻟﺘﻴﺎﺭ ﺍﻟﻨﺸﻂ‬
‫ﻋﻠﻰﺍﻟﻘﻴﻤﺔ ﺍﻟﻔﻌﻠﻴﺔ‪.‬‬
‫ﺍﺿﻐﻂﻋﻠﻰ ﺃﺯﺭﺍﺭ "‪ "IQ‬ﺃﻭ "‪ "IP‬ﺃﻭ "‪ "Harm‬ﻟﻠﺨﺮﻭﺝ‬ ‫‪IP‬‬
‫ﻣﻦﺍﻟﺸﺎﺷﺔ‪.‬‬
‫ﺗﻌﺮﺽﺍﻟﺸﺎﺷﺔ ﺍﻟﺘﻴﺎﺭ ﺍﻟﻨﺸﻂ ﻋﻠﻰ ﺍﻟﺘﺬﺑﺬﺏ ﺍﻷﺳﺎﺳﻲ‬
‫‪6.1.5‬ﺍﻟﺘﻮﺍﻓﻘﻴﺎﺕ )‪5‬ﺍﻟﻌﺎﺷﺮ‪13 -‬ﺍﻟﻌﺎﺷﺮ(‬
‫ﻓﻲﺩﺍﺉﺮﺓ ﺍﻟﻤﺤﻮﻻﺕ ﺍﻟﺤﺎﻟﻴﺔ )‪ .(CT‬ﻳﻀﻲء "ﺃﻣﺒﻴﺮ"‬
‫‪.LED‬‬
‫ﺿﺮﺭﻭﺗﻠﻒ‬
‫ﻳﺘﻢﻋﺮﺽ ﺍﻻﺗﺠﺎﻩ ﺍﻟﺤﺎﻟﻲ ﺃﻳﻀﺎً ﻭﻫﻮ ﺃﻣﺮ ﻣﻔﻴﺪ ﺃﺛﻨﺎء‬
‫ﺍﻻﺧﺘﺒﺎﺭﺍﺕ‪.‬ﻳﻮﺿﺢ ﻣﺆﺷﺮ ‪ "LED "Regen‬ﺃﻥ ﺍﻟﻄﺎﻗﺔ‬
‫ﺍﻟﻌﺎﺷﺮ‬‫ﺗﻈﻬﺮﻫﺬﻩ ﺍﻟﺸﺎﺷﺔ ‪5‬ﺍﻟﻌﺎﺷﺮ‪7 ،‬ﺍﻟﻌﺎﺷﺮ‪11 ،‬ﺍﻟﻌﺎﺷﺮﻭ ‪13‬‬
‫ﺍﻟﺘﻮﻟﻴﺪﻳﺔﺍﻟﻨﺸﻄﺔ ﻳﺘﻢ ﺇﻋﺎﺩﺗﻬﺎ ﺇﻟﻰ ﺍﻟﺘﻴﺎﺭ ﺍﻟﻜﻬﺮﺑﺎﺉﻲ‪.‬‬
‫ﺍﻟﺘﻮﺍﻓﻘﻴﺎﺕﻋﻠﻰ ﺍﻟﺠﻬﺪ‪ .‬ﺗﻈﻬﺮ ﺍﻟﻘﺮﺍءﺓ ﺍﻟﺘﻮﺍﻓﻘﻴﺔ‬
‫ﺇﺫﺍﺗﻤﺖ ﺑﺮﻣﺠﺔ ﻧﺴﺒﺔ ‪ CT‬ﻓﻲ ﺍﻟﺘﺘﺎﺑﻊ ‪ ،‬ﻓﺴﻴﺘﻢ ﻋﺮﺽ‬
‫ﺍﻟﺴﺎﺑﻘﺔﻋﻠﻰ ﺍﻟﺸﺎﺷﺔ )‪ (٪‬ﻭﻳﻀﻲء ﻣﺆﺷﺮ‬
‫ﺍﻟﺘﻴﺎﺭﺍﻟﻨﺸﻂ ﺍﻟﻔﻌﻠﻲ ؛ ﻭﺇﻻ ﻳﺘﻢ ﻋﺮﺽ ﺍﻟﺠﺰء ﺍﻟﺤﺎﻟﻲ‬
‫‪ ."LED "Harmonic‬ﺑﺎﻟﻀﻐﻂ ﻋﻠﻰ ﺃﺯﺭﺍﺭ "‪ "+‬ﺃﻭ "‪"-‬‬
‫ﻭﻳﺠﺐﺿﺮﺑﻪ ﺑﻨﺴﺒﺔ ‪ CT‬ﻟﻠﺤﺼﻮﻝ ﻋﻠﻰ ﺍﻟﻘﻴﻤﺔ‬
‫ﻋﺪﺓﻣﺮﺍﺕ ﻋﻠﻰ ﺃﺟﺰﺍء ‪5‬ﺍﻟﻌﺎﺷﺮ‪7 ،‬ﺍﻟﻌﺎﺷﺮ‪11 ،‬ﺍﻟﻌﺎﺷﺮﻭ ‪13‬ﺍﻟﻌﺎﺷﺮ‬
‫ﺍﻟﻔﻌﻠﻴﺔ‪.‬‬
‫ﻳﺘﻢﻋﺮﺽ ﺍﻟﺘﻮﺍﻓﻘﻴﺎﺕ ﻻﺣﻘﺎً ﺇﻣﺎ ﺑﺘﺮﺗﻴﺐ ﺗﺼﺎﻋﺪﻱ ﺃﻭ‬
‫ﺗﻨﺎﺯﻟﻲ‪.‬ﻓﻤﺜﻼ‪ .‬ﺇﺫﺍ ﺗﻢ ﻋﺮﺽ "‪ "2.9 .5‬ﻓﻬﺬﺍ ﻳﻌﻨﻲ "‪5‬‬
‫ﺍﻟﻌﺎﺷﺮﺍﻟﺘﻮﺍﻓﻘﻴﺎﺕ = ‪." ٪2.9‬‬
‫ﺍﺿﻐﻂﻋﻠﻰ ﺃﺯﺭﺍﺭ "‪ "IQ‬ﺃﻭ "‪ "IP‬ﺃﻭ "‪ "Harm‬ﻟﻠﺨﺮﻭﺝ‬
‫ﻣﻦﺍﻟﺸﺎﺷﺔ‪.‬‬
‫ﺍﺿﻐﻂﻋﻠﻰ ﺯﺭ "ﺿﺮﺭ" ﻟﻠﺨﺮﻭﺝ ﻣﻦ ﺍﻟﻌﺮﺽ‪.‬‬
‫‪6.1.4‬ﺍﻟﺘﻴﺎﺭ ﺍﻟﻈﺎﻫﺮ‬

‫‪6.2‬ﺍﻟﺘﺸﻐﻴﻞ ﺍﻟﻴﺪﻭﻱ‬ ‫‪IP‬‬ ‫ﻣﻌﺪﻝﺍﻟﺬﻛﺎء‬

‫ﺭﺟﻞ‬ ‫ﻳﺆﺩﻱﺍﻟﻀﻐﻂ ﻋﻠﻰ ﺯﺭﻱ "‪ "IQ‬ﻭ "‪ "IP‬ﺇﻟﻰ ﺗﻨﺸﻴﻂ‬


‫ﺗﻌﻴﻴﻦ‬ ‫ﺍﻟﻌﺮﺽﻓﻲ ﻧﻔﺲ ﺍﻟﻮﻗﺖ‪ .‬ﻳﻀﻲء "ﺃﻣﺒﻴﺮ" ‪ .LED‬ﺇﺫﺍ‬
‫ﺗﻤﺖﺑﺮﻣﺠﺔ ﻧﺴﺒﺔ ‪ CT‬ﻓﻲ ﺍﻟﺘﺘﺎﺑﻊ ‪ ،‬ﻓﺴﻴﺘﻢ ﻋﺮﺽ‬
‫ﻋﻨﺪﺍﻟﻀﻐﻂ ﻋﻠﻰ ﺯﺭ "‪ "man / Set‬ﻷﻛﺜﺮ ﻣﻦ ‪3‬‬
‫ﺍﻟﺘﻴﺎﺭﺍﻟﻈﺎﻫﺮﻱ ﺍﻟﻔﻌﻠﻲ ﻋﻠﻰ ﺍﻟﺘﺬﺑﺬﺏ ﺍﻷﺳﺎﺳﻲ ﻓﻲ‬
‫ﺛﻮﺍﻥ ٍ‪،‬ﻳﺘﺤﻮﻝ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﺇﻟﻰ ﺍﻟﺘﺸﻐﻴﻞ ﺍﻟﻴﺪﻭﻱ‬
‫ﺩﺍﺉﺮﺓﺍﻟﻤﺤﻮﻝ ﺍﻟﺤﺎﻟﻲ )‪ (CT‬؛ ﻭﺇﻻ ﺍﻟﺘﻴﺎﺭ‬
‫ﻭﻳﺒﺪﺃﻣﺆﺷﺮ ‪" LED‬ﺍﻟﻴﺪﻭﻱ" ﻓﻲ ﺍﻟﻮﻣﻴﺾ‪ .‬ﻳﻤﻜﻦ‬
‫ﺗﺸﻐﻴﻞﺃﻭ ﺇﻳﻘﺎﻑ ﻣﺮﺍﺣﻞ ﺍﻟﻤﻜﺜﻒ ﺑﺎﻟﻀﻐﻂ ﻋﻠﻰ ﺯﺭ‬
‫"‪ "+‬ﺃﻭ "‪."-‬‬

‫‪30‬‬
‫ﻓﻲﺍﻟﻮﺿﻊ ﺍﻟﻴﺪﻭﻱ ‪ ،‬ﻳﺘﻢ ﺃﺧﺬ ﻭﻗﺖ ﺍﻹﻳﻘﺎﻑ ﺍﻟﻤﺒﺮﻣﺞ )‬ ‫ﻋﻨﺪﺍﻟﻀﻐﻂ ﻋﻠﻰ ﺍﻟﺰﺭ "‪ "+‬ﻣﺮﺓ ﻭﺍﺣﺪﺓ ‪ ،‬ﻳﻈﻬﺮ "‪"ON.1‬‬
‫ﻭﻗﺖﺍﻟﺘﻔﺮﻳﻎ( ﻓﻲ ﺍﻻﻋﺘﺒﺎﺭ ‪ ،‬ﺃﻱ ﻋﻨﺪ ﺗﺸﻐﻴﻞ ﻣﺮﺣﻠﺔ‬ ‫ﻋﻠﻰﺍﻟﺸﺎﺷﺔ ﺣﺘﻰ ﻳﺘﻢ ﺗﺸﻐﻴﻞ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻓﻲ‬
‫ﺗﻢﺇﻳﻘﺎﻑ ﺗﺸﻐﻴﻠﻬﺎ ﻣﺴﺒﻘﺎً ‪ ،‬ﻳﻜﻮﻥ ﻭﻗﺖ ﺇﻳﻘﺎﻑ‬ ‫ﺍﻟﻤﺮﺣﻠﺔﺍﻷﻭﻟﻰ ﺑﻌﺪ ﺗﻘﺮﻳﺒﺎً‪ 10 .‬ﺛﻮﺍﻥ ٍﺑﺸﺮﻁ ﻋﺪﻡ‬
‫ﺍﻟﺘﺸﻐﻴﻞﻫﻮ ﻧﻔﺲ ﻭﻗﺖ ﺍﻟﺘﻔﺮﻳﻎ‪ .‬ﺇﺫﺍ ﺗﻢ ﺗﺤﺪﻳﺪ‬ ‫ﺍﻟﻀﻐﻂﻋﻠﻰ ﺃﺯﺭﺍﺭ ﺃﺧﺮﻯ‪ .‬ﺇﺫﺍ ﺗﻢ ﺑﺎﻟﻔﻌﻞ ﺗﺸﻐﻴﻞ‬
‫ﺍﻟﻤﺮﺣﻠﺔﻋﻠﻰ ﺃﻧﻬﺎ ﻣﺮﺣﻠﺔ ﺻﻔﺮﻳﺔ )ﺑﺪﻭﻥ ﻃﺎﻗﺔ( ‪ ،‬ﻓﺈﻥ‬ ‫ﺍﻟﻤﺮﺣﻠﺔﺍﻷﻭﻟﻰ ‪ ،‬ﻓﺴﺘﻈﻬﺮ "‪ "OFF.1‬ﻋﻠﻰ ﺍﻟﺸﺎﺷﺔ‬
‫ﺍﻷﺭﻗﺎﻡﺍﻟﻤﻘﺎﺑﻠﺔ ﺗﺸﻴﺮ ﺇﻟﻰ ﺫﻟﻚ ﻋﻦ ﻃﺮﻳﻖ ﺍﻟﻮﻣﻴﺾ‪.‬‬ ‫ﺣﺘﻰﻳﺘﻢ ﺇﻳﻘﺎﻑ ﺗﺸﻐﻴﻞ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻋﻦ ﺍﻟﻤﺮﺣﻠﺔ‬
‫ﺍﻷﻭﻟﻰﺑﻌﺪ ﺗﻘﺮﻳﺒﺎً‪ 10 .‬ﺛﻮﺍﻧﻰ‪ .‬ﺛﻢ ﺳﺘﺘﻐﻴﺮ ﺍﻟﺸﺎﺷﺔ ﺇﻟﻰ‬
‫ﺁﺧﺮﻗﻴﻤﺔ ﻣﻌﺮﻭﺿﺔ‪.‬‬

‫ﺍﺿﻐﻂﻋﻠﻰ ﺯﺭ "‪ "Man / Set‬ﻟﻠﺨﺮﻭﺝ ﻣﻦ ﺍﻟﻮﺿﻊ‬


‫ﺍﻟﻴﺪﻭﻱ‪.‬‬
‫ﺃﺛﻨﺎءﺍﻻﻧﺘﻈﺎﺭ ‪ ،‬ﺳﻴﺘﻢ ﻋﺮﺽ ﻋﺪﺍﺩ ﺍﻟﺘﺒﺪﻳﻞ ﻓﻲ ﻫﺬﻩ‬
‫ﺍﻟﻤﺮﺣﻠﺔﻟﻠﺤﻈﺔ ﻗﺼﻴﺮﺓ‪ .‬ﻳﺘﻢ ﺿﺮﺏ ﺍﻟﻘﻴﻤﺔ ﺍﻟﻤﻌﺮﻭﺿﺔ‬
‫‪6.3‬ﺍﻹﻧﺬﺍﺭﺍﺕ‬
‫ﻓﻲ‪ 0.001‬ﻭﻳﺘﻢ ﺍﻹﺷﺎﺭﺓ ﺇﻟﻴﻬﺎ ﺑﻘﺪﺭ ﺍﻹﻣﻜﺎﻥ ﻋﻠﻰ ﺃﻧﻬﺎ‬
‫ﻳﺘﻢﺇﻏﻼﻕ ﺍﺗﺼﺎﻝ ﺍﻹﻧﺬﺍﺭ ﺍﻟﺨﺎﻟﻲ ﻣﻦ ﺍﻹﻣﻜﺎﻧﺎﺕ )ﺃ ‪ /‬ﺏ‬ ‫ﻋﺪﺩﻋﺸﺮﻱ‪ .‬ﻫﺬﺍ ﻳﻌﻨﻲ ﻋﻠﻰ ﺳﺒﻴﻞ ﺍﻟﻤﺜﺎﻝ‪:‬‬
‫( ﻋﻨﺪﻣﺎ ﻻ ﻳﺘﻢ ﺗﻄﺒﻴﻖ ﺟﻬﺪ ﺍﻟﺘﺸﻐﻴﻞ‪ .‬ﻓﻲ ﺣﺎﻟﺔ ﺟﻬﺪ‬
‫ﺍﻟﺘﺸﻐﻴﻞﺍﻟﺼﺤﻴﺢ ‪ ،‬ﻳﺘﻢ ﺇﻏﻼﻕ ﺟﻬﺔ ﺍﻻﺗﺼﺎﻝ ﺇﺫﺍ ﻛﺎﻥ‬ ‫"‪ "0.350‬ﻳﻌﺎﺩﻝ ‪ 350‬ﻣﻔﺘﺎﺡ ﺗﺤﻮﻳﻞ‪.‬‬
‫ﻫﻨﺎﻙﺇﻧﺬﺍﺭ‪ .‬ﻳﻤﻜﻦ ﺭﺅﻳﺔ ﺷﺮﻭﻁ ﺍﻹﻧﺬﺍﺭ ﻓﻲ ﺍﻟﻘﺴﻢ‬
‫‪6.3.1‬ﺇﻟﻰ ‪ 6.3.7‬ﺃﺩﻧﺎﻩ‪ .‬ﻳﻀﻲء "ﺍﻟﻤﻨﺒﻪ" ‪ LED‬ﻣﺎ‬ ‫ﺑﺎﻟﻀﻐﻂﻋﻠﻰ ﺍﻟﺰﺭ "‪ "+‬ﻋﺪﺓ ﻣﺮﺍﺕ ﺳﺘﻈﻬﺮ ﺍﻟﻤﺮﺍﺣﻞ ‪2‬‬
‫ﺩﺍﻣﺖﺣﺎﻟﺔ ﺍﻹﻧﺬﺍﺭ ﻣﻮﺟﻮﺩﺓ‪ .‬ﻋﻨﺪﻣﺎ ﻳﺘﻢ ﺇﺭﺳﺎﻝ ﺇﺷﺎﺭﺓ‬ ‫‪ 6-‬ﺑﺘﺮﺗﻴﺐ ﺗﺼﺎﻋﺪﻱ ﻋﻠﻰ ﺍﻟﺸﺎﺷﺔ‪ .‬ﻳﻤﻜﻦ ﺗﺸﻐﻴﻠﻬﺎ ‪/‬‬
‫ﺇﻧﺬﺍﺭ ‪،‬ﻳﺘﻢ ﻭﺿﻊ ﻋﻼﻣﺔ ﺍﻟﺘﻨﺒﻴﻪ ﻣﻮﺿﻊ ﺍﻟﺘﻨﻔﻴﺬ )‬ ‫ﺇﻳﻘﺎﻑﺗﺸﻐﻴﻠﻬﺎ ﺑﻨﻔﺲ ﺍﻟﻄﺮﻳﻘﺔ‪.‬‬
‫ﻭﻣﻴﺾ‪ "LEDs "Power Factor‬ﺃﻭ "‪ "Ampere‬ﺃﻭ‬
‫"‪.("Harmonic‬‬ ‫ﺑﺎﻟﻀﻐﻂﻋﻠﻰ ﺍﻟﺰﺭ "‪ "-‬ﻣﺮﺓ ﻭﺍﺣﺪﺓ ﻳﻈﻬﺮ "‪ "ON.6‬ﻋﻠﻰ‬
‫ﺍﻟﺸﺎﺷﺔﺣﺘﻰ ﻳﺘﻢ ﺗﺸﻐﻴﻞ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻋﻠﻰ ﺍﻟﻤﺮﺣﻠﺔ‬
‫ﺍﻟﺴﺎﺩﺳﺔﺑﻌﺪ ﺗﻘﺮﻳﺒﺎً‪ 10 .‬ﺛﻮﺍﻧﻰ‪ .‬ﺇﺫﺍ ﺗﻢ ﺗﺸﻐﻴﻞ‬
‫ﺗﻈﻞﻋﻼﻣﺎﺕ ﺍﻟﺘﻨﺒﻴﻪ ﻧﺸﻄﺔ ﺑﻌﺪ ﺍﻟﺘﻨﺒﻴﻪ ﺣﺘﻰ ﻳﺘﻢ‬ ‫ﺍﻟﻤﺮﺣﻠﺔﺍﻟﺴﺎﺩﺳﺔ ﺑﺎﻟﻔﻌﻞ ‪ ،‬ﻓﺴﺘﻈﻬﺮ "‪ "OFF.6‬ﻋﻠﻰ‬
‫ﺍﻟﺘﻌﺮﻑﻋﻠﻴﻬﺎ ﺑﺎﻟﻀﻐﻂ ﻋﻠﻰ ﺍﻟﺰﺭ "ﺗﻌﻴﻴﻦ"‪ .‬ﺑﻌﺪ ﺍﻹﻗﺮﺍﺭ‬ ‫ﺍﻟﺸﺎﺷﺔﺣﺘﻰ ﻳﺘﻢ ﺇﻳﻘﺎﻑ ﺗﺸﻐﻴﻞ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻋﻦ‬
‫ﻳﻨﻄﻔﺊﻣﺆﺷﺮ ﺍﻹﻧﺬﺍﺭ ﺍﻟﻮﺍﻣﺾ‪.‬‬ ‫ﺍﻟﻤﺮﺣﻠﺔﺍﻟﺴﺎﺩﺳﺔ ﺑﻌﺪ ﺗﻘﺮﻳﺒﺎً‪ 10 .‬ﺛﻮﺍﻧﻰ‪ .‬ﺛﻢ ﺳﺘﺘﻐﻴﺮ‬
‫ﺍﻟﺸﺎﺷﺔﺇﻟﻰ ﺁﺧﺮ ﻗﻴﻤﺔ ﻣﻌﺮﻭﺿﺔ‪ .‬ﺑﺎﻟﻀﻐﻂ ﻋﻠﻰ ﺍﻟﺰﺭ‬
‫"‪ "-‬ﻋﺪﺓ ﻣﺮﺍﺕ ﺳﺘﻈﻬﺮ ﺍﻟﻤﺮﺍﺣﻞ ‪ 1 - 5‬ﻋﻠﻰ ﺍﻟﺸﺎﺷﺔ‬
‫ﻻﺗﺆﺛﺮ ﺇﺷﺎﺭﺍﺕ ﺍﻹﻧﺬﺍﺭ ﻋﻠﻰ ﺳﻠﻮﻙ ‪ /‬ﺃﺩﺍء ﺍﻟﺘﺤﻜﻢ ﻓﻲ‬ ‫ﺑﺘﺮﺗﻴﺐﺗﻨﺎﺯﻟﻲ‪ .‬ﻳﻤﻜﻦ ﺗﺸﻐﻴﻠﻬﺎ ‪ /‬ﺇﻳﻘﺎﻑ ﺗﺸﻐﻴﻠﻬﺎ‬
‫ﺍﻟﻤﺮﺣﻞ‪.‬‬ ‫ﺑﻨﻔﺲﺍﻟﻄﺮﻳﻘﺔ‪.‬‬

‫‪31‬‬
‫‪6.3.1‬ﺇﻧﺬﺍﺭ ﻋﺎﻣﻞ ﺍﻟﻄﺎﻗﺔ‬
‫ﺑﻌﺪﺍﻟﺘﻌﺮﻑ ﻋﻠﻰ ﺍﻹﻧﺬﺍﺭ ‪ ،‬ﻳﺴﺘﻐﺮﻕ ﺍﻷﻣﺮ ﺗﻘﺮﻳﺒﺎً‪4 .‬‬ ‫ﺇﺫﺍﺗﻢ ﺗﺠﺎﻭﺯ ﺍﻟﻘﻴﻢ ﺍﻟﺤﺪﻳﺔ ﺍﻟﻤﺤﺪﺩﺓ ﻟـ "ﺍﻟﺘﺒﺪﻳﻞ" ﻭ "‬
‫ﺩﻗﺎﺉﻖﺣﺘﻰ ﻳﺘﻢ ﺗﺸﻐﻴﻞ ﻣﺮﺍﺣﻞ ﺍﻟﻤﻜﺜﻒ ﺍﻟﻼﺯﻣﺔ‬ ‫ﺇﻳﻘﺎﻑﺍﻟﺘﺸﻐﻴﻞ" ﻭﻻ ﻳﻤﻜﻦ ﺇﺟﺮﺍء ﺃﻱ ﺗﻐﻴﻴﺮ ﺁﺧﺮ ﻓﻲ‬
‫ﻣﺮﺓﺃﺧﺮﻯ‪.‬‬ ‫ﻣﺮﺍﺣﻞﺍﻹﺧﺮﺍﺝ ‪ ،‬ﺗﻌﻤﻞ ﺇﺷﺎﺭﺓ ﺍﻟﺘﻨﺒﻴﻪ )ﺑﺎﺳﺘﺜﻨﺎء ﺇﻧﺬﺍﺭ‬
‫‪ cos-phi‬ﺍﻟﺬﻱ ﻳﺘﻢ ﺇﻳﻘﺎﻑ ﺗﺸﻐﻴﻠﻪ ؛ ﺍﻧﻈﺮ ﺍﻟﻮﺿﻊ ‪23-‬‬
‫ﺑﺎﻟﻀﻐﻂﻋﻠﻰ ﺍﻟﺰﺭ "‪ ، "Set‬ﺗﻈُﻬﺮ ﺍﻟﺸﺎﺷﺔ ﺍﻟﻘﻴﻤﺔ‬ ‫‪ .(-‬ﺑﺎﻟﻀﻐﻂ ﻋﻠﻰ ﺯﺭ "‪ ، "Set‬ﺗﻮﻣﺾ ﻛﻤﻴﺔ ﺍﻟﻄﺎﻗﺔ‬
‫ﺍﻟﻘﺼﻮﻯﻟﻠﻌﺎﻣﻞ ﺍﻟﺬﻱ ﺗﺠﺎﻭﺯ ﺑﻪ ﺗﻴﺎﺭ ‪ RMS‬ﺍﻟﺘﻴﺎﺭ‬ ‫ﺍﻟﺴﻌﻮﻳﺔﻭﺍﻟﺘﻔﺎﻋﻠﻴﺔ ﺍﻟﻤﻔﻘﻮﺩﺓ ﻟﻠﻮﺻﻮﻝ ﺇﻟﻰ ﻋﺎﻣﻞ‬
‫ﺍﻻﺳﻤﻲ‪.‬‬ ‫ﺍﻟﻄﺎﻗﺔﺍﻟﻤﺴﺘﻬﺪﻑ ﻋﻠﻰ ﺍﻟﺸﺎﺷﺔ‪ .‬ﻳﺆﺩﻱ ﺍﻟﻀﻐﻂ ﻋﻠﻰ‬
‫ﺍﻟﺰﺭ"ﺿﺒﻂ" ﻣﺮﺓ ﺃﺧﺮﻯ ﺇﻟﻰ ﺇﻇﻬﺎﺭ ﻋﺎﻣﻞ ﺍﻟﻄﺎﻗﺔ‬
‫ﺑﺎﻟﻀﻐﻂﻋﻠﻰ ﺍﻟﺰﺭ "‪ "Set‬ﻣﺮﺓ ﺃﺧﺮﻯ ‪ ،‬ﺗﻈُﻬﺮ ﺍﻟﺸﺎﺷﺔ‬ ‫ﺍﻟﻔﻌﻠﻲﻋﻠﻰ ﺍﻟﺸﺎﺷﺔ ﻭﻟﻢ ﻳﻌﺪ ﻣﺆﺷﺮ ﺍﻹﻧﺬﺍﺭ "‪Factor‬‬
‫ﻋﺎﻣﻞﺍﻟﻄﺎﻗﺔ ﺍﻟﻔﻌﻠﻲ ﻭﻟﻢ ﻳﻌﺪ ﻣﺆﺷﺮ ﺍﻹﻧﺬﺍﺭ‬ ‫‪ "Power‬ﻳﻮﻣﺾ‪.‬‬
‫"‪ "Ampere‬ﻳﻮﻣﺾ‪) .‬ﺍﻧﻈﺮ ﺃﻳﻀﺎً ﺍﻟﻘﺴﻢ ‪، 5.23‬‬
‫ﺍﻟﺼﻔﺤﺔ‪(28‬‬

‫ﻳﻼﺣﻆ‪:‬‬
‫ﻧﺴﺒﺔﺍﻟﺘﻴﺎﺭ ﺍﻟﺰﺍﺉﺪ ﻫﻲ ﻗﻴﻤﺔ ﻣﺤﺪﺩﺓ‬ ‫‪6.3.2‬ﺍﻟﺘﻨﺒﻴﻪ ﺍﻟﺘﻮﺍﻓﻘﻲ‬
‫ﺭﻳﺎﺿﻴﺎًﻭﺑﺎﻟﺘﺎﻟﻲ ﻻ ﻳﻤﻜﻦ ﺗﻄﺒﻴﻘﻬﺎ ﻋﻠﻰ‬ ‫ﻋﻨﺪﻣﺎﻳﺘﻢ ﺗﺠﺎﻭﺯ ﻗﻴﻢ ﺍﻟﻌﺘﺒﺔ ﺍﻟﻤﺒﺮﻣﺠﺔ ‪ ،‬ﻳﻨﻄﻠﻖ‬
‫ﺍﻷﻧﻈﻤﺔﺍﻟﺘﻲ ﺗﻤﺖ ﺗﺼﻔﻴﺘﻬﺎ‪.‬‬ ‫ﺍﻹﻧﺬﺍﺭ‪.‬‬
‫ﺑﺎﻟﻀﻐﻂﻋﻠﻰ ﺯﺭ "‪ "Set‬ﻋﺪﺓ ﻣﺮﺍﺕ ‪ ،‬ﺗﻈﻬﺮ ﺍﻟﺸﺎﺷﺔ‬
‫‪6.3.4‬ﺇﻧﺬﺍﺭ ﺩﻭﺭﺍﺕ ﺍﻟﺘﺸﻐﻴﻞ‬ ‫ﺍﻟﺘﺮﺗﻴﺐﻭﺍﻟﻘﻴﻢ ﺍﻟﻘﺼﻮﻯ ﻟﻠﺘﻮﺍﻓﻘﻴﺎﺕ ﺍﻟﺘﻲ ﺗﻢ‬
‫ﺗﺠﺎﻭﺯﻫﺎﺑﺪءﺍً ﻣﻦ ﺍﻟﺤﺪ ﺍﻷﻗﺼﻰ ﻟﻼﻧﺤﺮﺍﻑ‪.‬‬
‫ﺇﺫﺍﺗﺠﺎﻭﺯﺕ ﻣﺮﺣﻠﺔ ﻣﺎ ﺍﻟﺤﺪ ﺍﻟﻤﻌﻴﻦ ﻟﻌﺪﺩ ﺩﻭﺭﺍﺕ‬
‫ﺍﻟﺘﺸﻐﻴﻞ ‪،‬ﻓﺈﻥ ﻋﺪﺩ ﺍﻟﻤﺮﺣﻠﺔ ﺍﻟﺘﻲ ﺗﺠﺎﻭﺯﺕ ﺍﻟﺤﺪ‬
‫ﻳﻮﻣﺾﻓﻲ ﺍﻟﺸﺎﺷﺔ ﻛﻞ ‪ 10‬ﺛﻮﺍﻥ ٍﺗﻘﺮﻳﺒﺎً )ﻋﻠﻰ ﺳﺒﻴﻞ‬ ‫ﻳﺠﺐﺍﻟﻀﻐﻂ ﻋﻠﻰ ﺍﻟﺰﺭ "‪ "Set‬ﺑﺸﻜﻞ ﻣﺘﻜﺮﺭ ﺣﺘﻰ‬
‫ﺍﻟﻤﺜﺎﻝ"‬ ‫ﻳﺘﻮﻗﻒﺍﻟﻤﻨﺒﻪ "‪ "Harmonic‬ﻋﻦ ﺍﻟﻮﻣﻴﺾ‪.‬‬
‫"ﻟﻠﻤﺮﺣﻠﺔ ﺍﻟﺴﺎﺩﺳﺔ(‪ .‬ﻛﻤﺎ ﻳﺘﻢ ﺇﺭﺳﺎﻝ ﺇﺷﺎﺭﺓ‬
‫ﺇﻧﺬﺍﺭ‪.‬ﻳﺼﻒ ﺍﻟﻘﺴﻢ ‪ 5.15‬ﻛﻴﻔﻴﺔ ﺇﻟﻐﺎء ﺇﺷﺎﺭﺓ ﺍﻹﻧﺬﺍﺭ‬
‫ﻫﺬﻩ‪.‬‬ ‫‪6.3.3‬ﺇﻧﺬﺍﺭ ﺍﻟﺘﻴﺎﺭ ﺍﻟﺰﺍﺉﺪ‬

‫ﺇﻧﺬﺍﺭ"‪6.3.5 "U = 0‬‬ ‫ﺇﺫﺍﺗﺠﺎﻭﺯﺕ ﺍﻟﻨﺴﺒﺔ ﺑﻴﻦ ﺗﻴﺎﺭ ‪ RMS‬ﺍﻟﻤﻘﺎﺱ ﺑﺎﻟﻔﻌﻞ‬


‫ﻓﻲﺣﺎﻟﺔ ﺣﺪﻭﺙ ﺍﻧﻘﻄﺎﻉ ﻓﻲ ﻣﺴﺎﺭ ﺟﻬﺪ ﺍﻟﻘﻴﺎﺱ ‪،‬‬ ‫ﻭﺍﻟﺘﻴﺎﺭﺍﻻﺳﻤﻲ ﻟﻠﻤﻜﺜﻒ ﺍﻟﻘﻴﻤﺔ ﺍﻟﻤﺒﺮﻣﺠﺔ ﻟﻤﺪﺓ‬
‫ﻳﻘﻮﻡﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﺑﺈﻳﻘﺎﻑ ﺗﺸﻐﻴﻞ ﺟﻤﻴﻊ ﺍﻟﻤﺮﺍﺣﻞ‬ ‫ﺩﻗﻴﻘﺔﻭﺍﺣﺪﺓ ‪ ،‬ﻳﻨﻄﻠﻖ ﺍﻹﻧﺬﺍﺭ ﻭﻳﺘﻢ ﺇﻳﻘﺎﻑ ﺗﺸﻐﻴﻞ‬
‫ﺑﻌﺪﺣﻮﺍﻟﻲ ﺛﺎﻧﻴﺔ ﻭﺍﺣﺪﺓ‪ .‬ﻭﻳﻌﺮﺽ "‪."U = 0‬‬ ‫ﺟﻤﻴﻊﺍﻟﻤﺮﺍﺣﻞ‪.‬‬

‫‪32‬‬
‫‪.7‬ﺍﻟﺒﻴﺎﻧﺎﺕ ﺍﻟﻔﻨﻴﺔ‬
‫ﻃﺮﻳﻘﺔﺍﻻﺗﺼﺎﻝ‪:‬‬ ‫ﻓﻲﻧﻔﺲ ﺍﻟﻮﻗﺖ ‪ ،‬ﻳﺘﻢ ﺇﻏﻼﻕ ﺟﻬﺔ ﺍﺗﺼﺎﻝ ﺍﻟﺘﻨﺒﻴﻪ‬
‫ﺍﺗﺼﺎﻝﻃﻮﺭ ‪ /‬ﻃﻮﺭ ﺃﻭ ﺍﺗﺼﺎﻝ ﻃﻮﺭ ‪/‬‬ ‫ﻭﻳﻀﻲءﻣﺆﺷﺮ ‪" LED‬ﺍﻟﻤﻨﺒﻪ" ﻃﺎﻟﻤﺎ ﺃﻧﻪ ﻻ ﻳﻮﺟﺪ ﺟﻬﺪ‬
‫ﻣﺤﺎﻳﺪ‬ ‫ﻣﻄﺒﻖﻋﻠﻰ ﺃﻃﺮﺍﻑ ﺇﺩﺧﺎﻝ ﺍﻟﻘﻴﺎﺱ ﻟﻤﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ‪.‬‬
‫ﺍﻟﺘﻴﺎﺭﻋﺒﺮ ﺍﻟﻤﺤﻮﻝ ﺍﻟﺤﺎﻟﻲ ﻓﻲ ﺍﻟﻤﺮﺣﻠﺔ ﺍﻻﺧﺘﻴﺎﺭﻳﺔ )‬
‫ﺍﻟﺸﻜﻞ‪ ، 3‬ﺍﻟﺼﻔﺤﺔ ‪.(11‬‬
‫ﺟﻬﺪﺍﻟﺘﺸﻐﻴﻞ‪:‬‬
‫‪6.3.6 "C = 0" -Alarm‬‬
‫ﺟﺎﺉﺰﻣﻄﻠﻘﺎ ً‪/‬‬ ‫ﻣﺤﻄﺔﺍﻟﺘﻴﺎﺭ ﺍﻟﻜﻬﺮﺑﺎﺉﻲ‬ ‫ﺇﻣﺪﺍﺩ‬
‫ﻗﻴﻢﺍﻟﻌﺘﺒﺔ‬ ‫ﺍﻟﺠﻬﺪﺍﺍﻟﻜﻬﺮﺑﻰ‬ ‫ﺍﻟﺠﻬﺪﺍﺍﻟﻜﻬﺮﺑﻰ‬ ‫ﺇﺫﺍﻟﻢ ﻳﺤﺪﺩ ﺍﻟﻤﺮﺣﻞ ﻣﺮﺣﻠﺔ ﻣﻜﺜﻒ ﺃﺛﻨﺎء ﻋﻤﻠﻴﺔ ﺗﺤﺪﻳﺪ‬
‫‪198‬ﻓﻮﻟﺖ∽ ‪ 440...‬ﻓﻮﻟﺖ∽‬ ‫‪220‬ﻓﻮﻟﺖ∽ﺇﻟﻰ ‪ 400‬ﻓﻮﻟﺖ∽‬
‫‪230‬ﻓﻮﻟﺖ∽ ‪/‬‬
‫ﺍﻟﻄﺮﻑﺍﻟﺘﻠﻘﺎﺉﻲ ﻭﺗﺤﺪﻳﺪ ﺍﻟﻤﺮﺣﻠﺔ ﺍﻟﺤﺎﻟﻴﺔ ‪ ،‬ﻳﺘﻢ‬
‫‪400‬ﻓﻮﻟﺖ∽‬
‫ﺇﺭﺳﺎﻝﺇﺷﺎﺭﺓ ﺇﻧﺬﺍﺭ ﻭﺗﻈﻬﺮ ﺍﻟﺸﺎﺷﺔ "‪."C = 0‬‬
‫ﺍﻧﺘﺒﺎﻩ‪ :‬ﺍﻟﻤﺤﻄﺎﺕ ﺍﻟﻄﺮﻓﻴﺔ ‪ 230‬ﻓﻮﻟﺖ ﻭ ‪ 400‬ﻓﻮﻟﺖ‬
‫ﻣﻮﺻﻮﻟﺔﺩﺍﺧﻠﻴﺎً‪.‬‬
‫ﺗﻜﺮﺍﺭ‪:‬‬ ‫ﺗﺘﻢﻋﻤﻠﻴﺔ ﺗﺤﺪﻳﺪ ﺍﻟﻬﻮﻳﺔ ﻋﻠﻰ ﺍﻟﺮﻏﻢ ﻣﻦ ﺍﻹﻧﺬﺍﺭ‪.‬‬
‫‪50‬ﻫﺮﺗﺰ ‪ 60 /‬ﻫﺮﺗﺰ )‪ 48‬ﺇﻟﻰ ‪ 62‬ﻫﺮﺗﺰ(‬

‫ﺍﺳﺘﻬﻼﻙ‪:‬‬ ‫ﺇﻧﺬﺍﺭ"‪6.3.7 "I = 0‬‬


‫ﺗﻘﺮﻳﺒﺎ‪ 11-9.‬ﻓﻮﻟﺖ ﺃﻣﺒﻴﺮ ﻋﻨﺪ ‪ 0‬ﺇﻟﻰ ‪ 6‬ﺟﻬﺎﺕ ﺍﺗﺼﺎﻝ‬
‫ﻟﻠﺘﺤﻜﻢﻓﻲ ﻭﺿﻊ ﺍﻟﺘﺸﻐﻴﻞ‬
‫ﻓﻲﺣﺎﻟﺔ ﺣﺪﻭﺙ ﺍﻧﻘﻄﺎﻉ ﻓﻲ ﺍﻟﻤﺴﺎﺭ ﺍﻟﺤﺎﻟﻲ ﻟﻤﺪﺓ ‪3‬‬
‫ﺛﻮﺍﻥ ٍﻋﻠﻰ ﺍﻷﻗﻞ ‪ ،‬ﻳﻘﻮﻡ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻓﻮﺭﺍً ﺑﺈﻳﻘﺎﻑ‬
‫ﺍﻟﻤﺴﺎﺭﺍﻟﺤﺎﻟﻲ‪:‬‬ ‫ﺗﺸﻐﻴﻞﻣﺮﺣﻠﺔ ﺍﻟﻤﻜﺜﻒ‪.‬‬
‫ﻟﻠﻤﺤﻮﻝﺍﻟﺤﺎﻟﻲ ‪∽1A / ...‬ﺇﻟﻰ ‪∽5A / ...‬‬
‫ﺍﻻﺳﺘﻬﻼﻙﻓﻲ ﺍﻟﻤﺴﺎﺭ ﺍﻟﺤﺎﻟﻲ‪:‬‬ ‫ﺇﺫﺍﻟﻢ ﻳﻜﻦ ﻫﻨﺎﻙ ﺗﻐﻴﻴﺮ ﻓﻲ ﺍﻟﺘﻴﺎﺭ ﻧﺘﻴﺠﺔ ﻟﺬﻟﻚ ‪ ،‬ﻳﺘﻢ‬
‫ﺍﻷﻋﻠﻰ‪ 1.8.‬ﻓﻮﻟﺖ ﺃﻣﺒﻴﺮ ﻋﻨﺪ ‪ 5‬ﺃ∽ﺍﻟﺘﺼﻨﻴﻒ ﺍﻟﺤﺎﻟﻲ ﻣﻦ‬
‫ﺇﻳﻘﺎﻑﺗﺸﻐﻴﻞ ﺍﻟﻤﺮﺍﺣﻞ ﺍﻟﺘﻲ ﻻ ﺗﺰﺍﻝ ﻗﻴﺪ ﺍﻟﺘﺸﻐﻴﻞ‪.‬‬
‫‪CT‬‬
‫ﻫﻨﺎﻟﻚﺭﻗﻢ ﺇﻧﺬﺍﺭ‪.‬‬
‫ﺍﺗﺼﺎﻻﺕﺍﻟﺘﺤﻜﻢ‪:‬‬
‫‪6‬ﺟﻬﺎﺕ ﺍﺗﺼﺎﻝ ﺗﺮﺣﻴﻞ ﺧﺎﻟﻴﺔ ﻣﻦ ﺍﻹﻣﻜﺎﻧﺎﺕ‬

‫‪33‬‬
‫ﻗﻄﻊ‪:‬‬ ‫ﺳﻌﺔﺗﺤﻤﻴﻞ ﺟﻬﺎﺕ ﺍﺗﺼﺎﻝ ﺍﻟﺘﺤﻜﻢ‪:‬‬
‫ﻣﻦﺧﻼﻝ ﺍﻟﻠﻮﺣﺔ ﺍﻷﻣﺎﻣﻴﺔ ﺑﻮﺍﺳﻄﺔ ﻣﻔﻚ ﺍﻟﺒﺮﺍﻏﻲ‬
‫ﺗﺒﺪﻳﻞﺍﻟﺠﻬﺪ‪:‬‬
‫‪.‬ﻛﺤﺪﺃﻗﺼﻰ ‪ VA‬ﺗﺤﻮﻳﻞ ﺍﻟﺘﻴﺎﺭ ﺣﺘﻰ ‪ 5‬ﺃﻣﺒﻴﺮ ﻛﺤﺪ‬
‫ﺃﺑﻌﺎﺩﺍﻟﻠﻮﺣﺔ ﺍﻷﻣﺎﻣﻴﺔ‪144 × 144 :‬‬
‫ﺃﻗﺼﻰ‪.‬ﺗﺤﻮﻳﻞ ﺍﻟﺤﻤﻞ ﺣﺘﻰ ‪ C( 1800‬ﺍﻟﺠﺰء‬
‫ﻣﻢ)ﺣﺘﻰ ‪(DIN 43700‬‬
‫‪ VDE0110‬ﺇﻟﻰ ‪ B( 250 VAC )acc.‬ﺍﻟﺠﺰء‬
‫ﻗﻄﻊﺍﻟﻠﻮﺣﺔ‪:‬‬ ‫‪ VDE0110‬ﺇﻟﻰ ‪380 VAC )acc.‬‬
‫‪ 138 ×138‬ﻣﻢ )ﺣﺘﻰ ‪(DIN 43700‬‬
‫ﺍﺗﺼﺎﻻﺕﺇﺷﺎﺭﺓ ﺧﻄﺄ‪:‬‬
‫ﺗﺼﺎﻋﺪﺍﻟﻌﻤﻖ‪:‬‬ ‫ﻗﺪﺭﺓﺍﻟﺘﺤﻤﻴﻞ ‪ 250‬ﻓﻮﻟﺖ∽ ‪ 3،‬ﺃ‬
‫‪40‬ﻣﻠﻢ‬
‫ﺭﺣﻠﺔﺑﺪﻭﻥ ﺟﻬﺪ‬
‫ﻭﺯﻥ‪:‬‬ ‫)ﻣﺮﺍﻗﺒﺔ ﺍﻧﺨﻔﺎﺽ ﺍﻟﺠﻬﺪ(‪:‬‬
‫ﻛﺎﻟﻴﻔﻮﺭﻧﻴﺎ‪ 0.9.‬ﻛﺠﻢ‬ ‫ﻟﻔﻘﺪﺍﻥﺍﻟﺠﻬﺪ ﻟﻤﺪﺓ ﺃﻃﻮﻝ ﻣﻦ ‪ 15‬ﻣﻠﻠﻲ ﺛﺎﻧﻴﺔ ‪ ،‬ﻳﺘﻢ‬
‫ﺍﻟﻤﻮﻗﻒﺍﻟﻤﺘﺼﺎﻋﺪ‪:‬‬ ‫ﺇﻳﻘﺎﻑﺗﺸﻐﻴﻞ ﺟﻤﻴﻊ ﻣﺮﺍﺣﻞ ﺍﻟﻤﻜﺜﻒ ﺍﻟﻤﺘﺼﻠﺔ‪ .‬ﺑﻌﺪ‬
‫ﺣﺴﺐﺍﻟﺮﻏﺒﺔ‬ ‫ﺍﺳﺘﻌﺎﺩﺓﺍﻟﺠﻬﺪ ‪ ،‬ﻳﻘﻮﻡ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﺑﺘﺒﺪﻳﻞ ﺍﻟﻤﺮﺍﺣﻞ‬
‫ﺍﻟﻤﻄﻠﻮﺑﺔ‪.‬‬
‫ﻣﺤﻄﺎﺕ‪:‬‬
‫ﻛﺘﻞﻣﻮﺻﻞ ﺍﻟﺘﻮﺻﻴﻞ )ﻣﺮﻓﻖ ﻣﻊ‬ ‫ﺍﻟﺮﺣﻠﺔﺍﻟﺤﺎﻟﻴﺔ ﺻﻔﺮ‪:‬‬
‫ﻣﺮﺣﻞﺍﻟﺘﺤﻜﻢ(‬ ‫ﻟﻔﻘﺪﺍﻥﺗﻴﺎﺭ ﺃﻃﻮﻝ ﻣﻦ ‪ 3‬ﺛﻮﺍﻥ ٍ‪ ،‬ﻳﺘﻢ ﺇﻳﻘﺎﻑ ﺗﺸﻐﻴﻞ‬
‫ﻣﺮﺍﺣﻞﺍﻟﻤﻜﺜﻒ ﺍﻟﻤﺘﺼﻠﺔ‪ .‬ﺑﻌﺪ ﺍﺳﺘﻌﺎﺩﺓ ﺍﻟﺘﻴﺎﺭ ‪ ،‬ﻳﻘﻮﻡ‬
‫ﻧﺴﻴﺞ‪:‬‬ ‫ﻣﺮﺣﻞﺍﻟﺘﺤﻜﻢ ﺑﺘﺒﺪﻳﻞ ﺍﻟﻤﺮﺍﺣﻞ ﺍﻟﻤﻄﻠﻮﺑﺔ‪.‬‬
‫‪IP20‬‬ ‫ﻣﺤﻄﺎﺕ‬
‫‪IP54‬‬ ‫ﻏﻼﻑ‬
‫)ﻋﻨﺪ ﺍﺳﺘﺨﺪﺍﻡ ﺣﻠﻘﺔ ﺍﻟﺨﺘﻢ(‬ ‫ﻋﻨﺎﺻﺮﺍﻟﺘﺸﻐﻴﻞ‪:‬‬
‫ﻟﻮﺣﺔﻣﻔﺎﺗﻴﺢ ﺫﺍﺕ ‪ 4‬ﺃﺯﺭﺍﺭ‬
‫ﺗﺼﻤﻴﻢ‪:‬‬
‫ﺑﺎﻟﻨﺴﺒﺔﺍﻟﻰ‪:‬‬ ‫ﻣﺆﺷﺮﺍﺕ‪:LED‬‬
‫‪EN 50081-1 -‬‬ ‫‪12‬ﻟﻴﺪ‬
‫‪EN 50082-2 -‬‬ ‫ﺷﺎﺷﺔﺭﻗﻤﻴﺔ ﻣﻜﻮﻧﺔ ﻣﻦ ‪ 4‬ﺃﺣﺮﻑ‬
‫‪EN61010 -‬‬ ‫ﻧﻄﺎﻕﺩﺭﺟﺔ ﺣﺮﺍﺭﺓ‪:‬‬
‫ﻓﺉﺔﺍﻟﺤﻤﺎﻳﺔ ﺍﻟﺜﺎﻧﻴﺔ )ﻓﻲ ﺣﺎﻟﺔ ﺍﺳﺘﺨﺪﺍﻡ ﻣﺴﺎﻣﻴﺮ‬ ‫‪ 20-‬ﺩﺭﺟﺔ ﻣﺉﻮﻳﺔ ﺇﻟﻰ ‪ 60+‬ﺩﺭﺟﺔ ﻣﺉﻮﻳﺔ‬

‫ﺍﻟﺘﺜﺒﻴﺖﺍﻟﻤﻌﺰﻭﻟﺔ( (ﺍﻟﺠﺰء ‪)VDE 0411 1‬‬


‫ﺍﻟﻤﻮﺍﺩﺍﻟﻀﻤﻴﻤﺔ‪:‬‬
‫ﺍﻻﻧﺼﻬﺎﺭ‪:‬‬ ‫ﺑﻼﺳﺘﻴﻚﺻﻨﺎﻋﻲ ﺃﺳﻮﺩ ‪ ،‬ﻣﻘﺎﻭﻡ ﻟﻠﻬﺐ ‪ ، UL-94‬ﻓﺉﺔ‬
‫ﺧﺎﺭﺟﻲ ‪،‬ﺑﺤﺪ ﺃﻗﺼﻰ‪ 4 .‬ﺍ‬ ‫‪V0‬‬

‫‪34‬‬
‫‪.8‬ﺍﺳﺘﻜﺸﺎﻑ ﺍﻷﺧﻄﺎء ﻭﺇﺻﻼﺣﻬﺎ‬

‫ﻥﺍﻟﻌﻤﻞﺍﻟﻜﺴﺎﻟﻰ‬ ‫ﺍﻷﺳﺒﺎﺏﺍﻟﻤﺤﺘﻤﻠﺔ‬ ‫ﻓﻮﺍﻟﻖ‬ ‫ﻧﻘﺎﻁﺍﻟﺒﻴﻊ‪.‬‬

‫ﺗﺤﻘﻖﻣﻤﺎ ﺇﺫﺍ ﻛﺎﻥ ﺟﻬﺪ ﺍﻟﺘﺸﻐﻴﻞ ﺍﻟﺼﺤﻴﺢ‬ ‫ﺇﻣﺎﺃﻧﻪ ﻻ ﻳﻮﺟﺪ ﺟﻬﺪ ﺃﻭ ﺗﻢ ﺗﻄﺒﻴﻖ‬ ‫ﻣﺮﺣﻞﺍﻟﺘﺤﻜﻢ ﻻ ﻳﻌﻤﻞ ‪ ،‬ﺗﻈﻞ‬ ‫‪1‬‬
‫ﻣﻄﺒﻘﺎًﻋﻠﻰ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ‪.‬‬ ‫ﺟﻬﺪﺧﺎﻃﺊ ﻋﻠﻰ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ‪.‬‬ ‫ﺍﻟﺸﺎﺷﺔﺍﻟﺮﻗﻤﻴﺔ ﻓﺎﺭﻏﺔ‪.‬‬

‫ﺗﺤﻘﻖﻣﻦ ﺟﻬﺪ ﺍﻟﺘﺸﻐﻴﻞ‪ .‬ﺇﺫﺍ ﻛﺎﻥ ﺍﻟﺠﻬﺪ ﺻﺤﻴﺤﺎً ‪،‬‬ ‫ﺍﻟﺠﻬﺪﺍﻟﻤﻄﺒﻖ ﻋﻠﻰ ﻣﺴﺎﺭ ﺍﻟﺠﻬﺪ‬ ‫‪.‬ﻳﻮﻣﺾﻋﻠﻰ ﺍﻟﺸﺎﺷﺔ ‪0‬‬ ‫‪2‬‬
‫ﻓﺎﺿﻐﻂﻋﻠﻰ ﺍﻷﺯﺭﺍﺭ "‪ "+‬ﻭ "‪ "-‬ﻭ "ﺿﺒﻂ" ﻟﻠﺘﻌﺮﻑ‬ ‫ﻟﺘﺮﺣﻴﻞﺍﻟﺘﺤﻜﻢ ﺻﻐﻴﺮ ﺟﺪﺍً‪.‬‬ ‫=‪U‬‬
‫ﻋﻠﻰﻫﺬﺍ ﺍﻟﺠﻬﺪ ﻛﺠﻬﺪ ﻣﻘﺪﺭ‪.‬‬

‫ﻋﻠﻰﺳﺒﻴﻞ ﺍﻟﻤﺜﺎﻝ ‪ ،‬ﺇﺫﺍ ﻇﻬﺮ "‪ "ON .1‬ﻋﻠﻰ‬ ‫ﻭﻗﺖﺍﻧﺘﻬﺎء ﺍﻟﺘﺄﺧﻴﺮ ﺣﻮﺍﻟﻲ‪10 .‬‬ ‫ﻻﻳﺴﺘﺠﻴﺐ ﺍﻟﺘﺘﺎﺑﻊ ﻟﻠﺘﺸﻐﻴﻞ‬ ‫‪3‬‬
‫ﺍﻟﺸﺎﺷﺔ ‪،‬ﻓﺎﻧﺘﻈﺮ ﺣﺘﻰ ﻳﺘﻢ ﺗﺸﻐﻴﻞ ﻣﺮﺣﻞ‬ ‫ﺛﻮﺍﻧﻰ‪.‬ﻟﻢ ﻳﻜﻦ‬ ‫ﺍﻟﻴﺪﻭﻱ‬
‫ﺍﻟﺘﺤﻜﻢﻓﻲ ﺍﻟﻤﺮﺣﻠﺔ ﺍﻷﻭﻟﻰ‪.‬‬ ‫ﻻﺣﻆ‪.‬‬ ‫ﻋﻠﻰﺍﻟﺮﻏﻢ ﻣﻦ ﺃﻥ ﻟﺪﻳﻬﺎ‬
‫ﻳﺠﺐﺍﻟﻀﻐﻂ ﻋﻠﻰ ﺍﻟﺰﺭ "‪ "Man‬ﻣﻤﺎ ﻳﺆﺩﻱ ﺇﻟﻰ‬ ‫ﻟﻢﻳﻜﻦ ﺍﻟﺘﺘﺎﺑﻊ ﻓﻲ ﺍﻟﻮﺿﻊ‬ ‫ﺍﻟﺠﻬﺪﻭﺍﻟﻌﺮﺽ ﺍﻟﺮﻗﻤﻲ ﻗﻴﺪ‬
‫ﻭﻣﻴﺾ"ﻳﺪﻭﻱ" ‪.LED‬‬ ‫ﺍﻟﻴﺪﻭﻱ‪.‬‬ ‫ﺍﻟﺘﺸﻐﻴﻞ‪.‬‬
‫ﺍﻓﺤﺺﺩﺍﺉﺮﺓ ﺍﻟﺘﺤﻜﻢ ﻭﻓﻘﺎً ﻟﻤﺨﻄﻂ ﺍﻟﺪﺍﺉﺮﺓ‬ ‫ﺩﺍﺉﺮﺓﺍﻟﺘﺤﻜﻢ ﻏﻴﺮ ﻣﺘﺼﻠﺔ‬ ‫ﻋﺮﺽﺍﻟﻤﺮﺣﻠﺔ‬ ‫‪4‬‬
‫ﻭﺍﻓﺤﺺﺍﻟﺼﻤﺎﻣﺎﺕ‪.‬‬ ‫ﺑﺸﻜﻞﺻﺤﻴﺢ ﺃﻭ‬ ‫ﻳﻀﻲءﻟﻜﻦ ﺍﻟﻤﻮﺻﻼﺕ ﻣﻜﺜﻒ‬
‫ﻻﻳﻮﺟﺪ ﺟﻬﺪ ﺗﺤﻜﻢ‬ ‫(‪)LED 1-6‬‬
‫ﻻﻳﻮﺟﺪ ﻣﺤﺎﻳﺪ ﻋﻠﻰ ﺍﻟﻤﻮﺻﻼﺕ‪.‬‬ ‫ﻟﻢﻳﺘﻢ ﺗﻔﻌﻴﻠﻬﺎ‬

‫ﺍﻧﺘﻈﺮﺣﺘﻰ ﻳﺴﺘﻘﺮ ﻣﺼﺪﺭ ﺍﻟﻄﺎﻗﺔ ﺃﻭ ﻗﻢ ﺑﺘﻌﻴﻴﻦ‬ ‫ﻣﺼﺪﺭﻃﺎﻗﺔ ﻏﻴﺮ ﻣﺴﺘﻘﺮ‬ ‫ﻣﺮﺣﻞﺍﻟﺘﺤﻜﻢ ﻻ ﻳﻜﻤﻞ‬ ‫‪5‬‬
‫ﻋﺎﻣﻞ‪ c / k‬ﻭﻭﺿﻊ ﺍﻻﺗﺼﺎﻝ ﻳﺪﻭﻳﺎً‪.‬‬ ‫)ﺗﻘﻠﺐ ﻣﻌﺎﻣﻞ ﺍﻟﻘﺪﺭﺓ(‪.‬‬ ‫ﺍﻟﺘﻠﻘﺎﺉﻲ‬
‫ﺇﺟﺮﺍءﺗﺤﺪﻳﺪ ﺍﻟﻬﻮﻳﺔ‬
‫ﺗﺤﻘﻖﻣﻦ ﺩﺍﺉﺮﺓ ﺍﻟﺘﺤﻜﻢ ﻭﻓﻘﺎً ﻟﻤﺨﻄﻂ‬ ‫ﺧﻄﺄﻓﻲ ﺩﺍﺉﺮﺓ ﺍﻟﺘﺤﻜﻢ )‬ ‫ﺃﺛﻨﺎءﺍﻟﺘﺸﻐﻴﻞ ﺍﻟﺘﻠﻘﺎﺉﻲ‬ ‫‪6‬‬
‫ﺍﻟﺪﺍﺉﺮﺓ ؛ﺗﺤﻘﻖ ﻣﻦ ﺍﻟﺼﻤﺎﻣﺎﺕ‪.‬‬ ‫ﺍﻟﻤﻮﺻﻼﺕﻻ ﺗﺘﺒﺪﻝ(‬ ‫ﻋﻤﻠﻴﺔﺍﻟﺘﻌﺪﻳﻞ‬
‫ﺗﺤﻘﻖﻣﻦ ﺗﻨﺸﻴﻂ ﺍﻟﻤﻜﺜﻔﺎﺕ ﺑﻌﺪ ﺍﻟﺘﺒﺪﻳﻞ‪.‬‬ ‫ﺍﻟﺼﻤﺎﻣﺎﺕﻟﻤﺮﺍﺣﻞ ﺍﻟﻤﻜﺜﻒ ﻣﻌﻴﺒﺔ ﺃﻭ‬ ‫ﻳﻮﻣﺾ"‪ "C = 0‬ﻋﻠﻰ‬
‫ﻣﻔﻘﻮﺩﺓ‪.‬‬ ‫ﺍﻟﺸﺎﺷﺔ‪.‬‬
‫ﺗﺤﻘﻖﻣﻤﺎ ﺇﺫﺍ ﻛﺎﻥ ﻣﻮﺿﻊ ﺍﻟﻤﺤﻮﻝ‬ ‫ﺍﻟﻤﺤﻮﻝﺍﻟﺤﺎﻟﻲ ﻓﻲ ﺍﻟﻤﻜﺎﻥ ﺍﻟﺨﻄﺄ‪.‬‬
‫ﺍﻟﺤﺎﻟﻲﻳﺘﻮﺍﻓﻖ ﻣﻊ ﻣﺨﻄﻂ ﺍﻟﺪﺍﺉﺮﺓ‪.‬‬

‫ﺍﺳﺘﺨﺪﻡﻣﻘﻴﺎﺱ ﺍﻟﺘﻴﺎﺭ ﺍﻟﻜﻬﺮﺑﺎﺉﻲ ﻟﻠﺘﺤﻘﻖ ﻣﻦ ﺍﻟﺘﻴﺎﺭ ﻋﻠﻰ ﺍﻟﺠﺎﻧﺐ‬ ‫ﺍﻧﻘﻄﻌﺖﺩﺍﺉﺮﺓ ﺍﻟﻤﺤﻮﻻﺕ ﺍﻟﺤﺎﻟﻴﺔ‬ ‫ﻳﻮﻣﺾ"‪ "I = 0‬ﻋﻠﻰ‬ ‫‪7‬‬
‫ﺍﻟﺜﺎﻧﻮﻱﻣﻦ ﺍﻟﺘﺼﻮﻳﺮ ﺍﻟﻤﻘﻄﻌﻲ ﺍﻟﻤﺤﻮﺳﺐ‪.‬‬ ‫ﺃﻭﻻ ﻳﻮﺟﺪ ﺗﻴﺎﺭ ﻳﺘﺪﻓﻖ ﻋﻠﻰ ﺍﻟﺠﺎﻧﺐ‬ ‫ﺍﻟﺸﺎﺷﺔ‪.‬‬
‫)ﺃﻧﺎ ﺩﻗﻴﻘﺔ< = ‪.(0.02A‬‬ ‫ﺍﻟﺜﺎﻧﻮﻱ‪.‬‬

‫)ﺃﻧﺎ ﺩﻗﻴﻘﺔ< = ‪(0.02A‬‬ ‫ﺍﻟﺘﻴﺎﺭﺍﻟﻤﺘﺪﻓﻖ ﻋﻠﻰ ﺍﻟﺠﺎﻧﺐ ﺍﻟﺜﺎﻧﻮﻱ‬


‫ﻗﻢﺑﺘﺮﻛﻴﺐ ﻣﺤﻮﻝ ﺗﻴﺎﺭ ﺃﺻﻐﺮ‪.‬‬ ‫ﻣﻦﺍﻟﺘﺼﻮﻳﺮ ﺍﻟﻤﻘﻄﻌﻲ ﺻﻐﻴﺮ ﺟﺪﺍً‪.‬‬

‫ﺗﺤﻘﻖﻣﻦ ﺍﻟﻤﺤﻮﻝ ﺍﻟﺤﺎﻟﻲ‪.‬‬ ‫ﺍﻟﻤﺤﻮﻝﺍﻟﺤﺎﻟﻲ‬


‫ﻣﻌﻴﺐ‪.‬‬

‫‪35‬‬
‫ﻥﺍﻟﻌﻤﻞﺍﻟﻜﺴﺎﻟﻰ‬ ‫ﺍﻷﺳﺒﺎﺏﺍﻟﻤﺤﺘﻤﻠﺔ‬ ‫ﻓﻮﺍﻟﻖ‬ ‫ﻧﻘﺎﻁﺍﻟﺒﻴﻊ‪.‬‬

‫ﺗﺤﻘﻖﻣﻦ ﺑﺮﻣﺠﺔ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﻭﻗﻢ ﺑﺘﻐﻴﻴﺮﻩ‬ ‫ﻋﻨﺪﺑﺮﻣﺠﺔ ﻣﻠﻒ‬ ‫ﻋﻠﻰﺍﻟﺮﻏﻢ ﻣﻦ ﺍﻟﺤﻤﻞ ﺍﻻﺳﺘﻘﺮﺍﺉﻲ‬ ‫‪8‬‬
‫ﺇﺫﺍﻟﺰﻡ ﺍﻷﻣﺮ‪.‬‬ ‫ﺗﻢﺿﺒﻂ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﺃﻭ ﻋﺎﻣﻞ ‪c / k‬‬ ‫ﻻﻳﺘﻢ ﺗﺸﻐﻴﻞ ﺃﻱ ﻣﺮﺍﺣﻞ‬
‫ﺃﻭﺗﺄﺧﻴﺮ ﻭﻗﺖ ﺍﻟﺘﺒﺪﻳﻞ ﺃﻭ ﻭﻗﺖ ﺍﻟﺘﻔﺮﻳﻎ‬ ‫ﻋﻨﺪﻣﺎﻳﻜﻮﻥ ﺍﻟﺘﺘﺎﺑﻊ ﻓﻲ ﺍﻟﻮﺿﻊ‬
‫ﺑﺪﺭﺟﺔﻋﺎﻟﻴﺔ ﺟﺪﺍً‪.‬‬ ‫ﺍﻟﺘﻠﻘﺎﺉﻲ‪.‬‬

‫ﺗﺤﻘﻖﻣﻦ ﺩﺍﺉﺮﺓ ﺍﻟﺘﺤﻜﻢ ﻭﻓﻘﺎً ﻟﻤﺨﻄﻂ ﺍﻟﺪﺍﺉﺮﺓ‬ ‫ﻓﻲﺍﻟﺘﺸﻐﻴﻞ ﺍﻟﺘﻠﻘﺎﺉﻲ ‪ ،‬ﻟﻢ ﻳﻜﻦ ﻋﺎﻣﻞ‬
‫ﻭﻛﺮﺭﺇﺟﺮﺍء ﺍﻻﺧﺘﺒﺎﺭ ﺍﻟﺘﻠﻘﺎﺉﻲ‪.‬‬ ‫‪ c / k‬ﺻﺤﻴﺤﺎً‬
‫ﻣﻜُﺘﺸَﻒَ‪.‬‬
‫ﻳﺠﺐﺗﻮﺻﻴﻞ ﺟﻤﻴﻊ ﺃﺩﻭﺍﺕ ﺍﻟﻘﻴﺎﺱ ﻓﻲ ﺍﻟﻤﺴﺎﺭ‬ ‫ﺗﻢﺗﻮﺻﻴﻞ ﻋﺪﺍﺩ ﻗﻴﺎﺱ ﺗﻴﺎﺭ ﻣﺨﺘﻠﻒ )‬
‫ﺍﻟﺤﺎﻟﻲﻓﻲ ﺳﻠﺴﻠﺔ‬ ‫ﻣﺜﻞﻣﻘﻴﺎﺱ ﺍﻟﺘﻴﺎﺭ( ﺑﺎﻟﺘﻮﺍﺯﻱ ﻣﻊ‬
‫ﻣﺮﺣﻞﺍﻟﺘﺤﻜﻢ ﺑﺎﻟﺠﺎﻧﺐ ﺍﻟﺜﺎﻧﻮﻱ‬
‫ﻟﻠﻤﺤﻮﻝﺍﻟﺤﺎﻟﻲ‪.‬‬

‫ﻣﻄﻠﻮﺏﺿﺒﻂ ﺃﺩﻕ ﻟﻤﺮﺍﺣﻞ ﺍﻟﻤﻜﺜﻒ‪.‬‬ ‫ﻣﺮﺍﺣﻞﺍﻟﻤﻜﺜﻒ ﻭﺍﺳﻌﺔ ﺟﺪﺍً‪.‬‬

‫ﺍﺿﺒﻂﻗﻴﻤﺔ ‪ c / k‬ﺑﺸﻜﻞ ﺻﺤﻴﺢ ﻭﻓﻘﺎً‬ ‫ﺗﻢﺗﻌﻴﻴﻦ ﻋﺎﻣﻞ ‪ c / k‬ﻣﻨﺨﻔﻀﺎً ﺟﺪﺍً‪.‬‬ ‫ﻓﻲﺍﻟﻮﺿﻊ ﺍﻟﺘﻠﻘﺎﺉﻲ ‪ ،‬ﺗﻜﻮﻥ‬ ‫‪9‬‬
‫ﻟﻠﺠﺪﻭﻝ‪.3‬‬ ‫ﺇﺣﺪﻯﺍﻟﻤﺮﺍﺣﻞ ﺑﺎﺳﺘﻤﺮﺍﺭ‬
‫ﺍﺿﺒﻂﻭﻗﺖ ﺗﺄﺧﻴﺮ ﺃﻋﻠﻰ‪.‬‬ ‫ﺗﻐﻴﻴﺮﺣﻤﻮﻟﺔ ﻋﺎﻟﻴﺔ ﺗﻢ ﺗﻌﻴﻴﻦ ﻭﻗﺖ‬ ‫ﺗﺸﻐﻴﻞﺃﻭ ﺇﻳﻘﺎﻑ )‬
‫ﺍﻟﺘﺄﺧﻴﺮﻣﻨﺨﻔﻀﺎً ﺟﺪﺍً‪.‬‬ ‫ﺍﻟﺼﻴﺪ(‪.‬‬
‫ﺇﻋﺎﺩﺓﻭﺿﻊ ﺍﻻﺗﺼﺎﻝ‪.‬‬ ‫ﻭﺿﻊﺍﻻﺗﺼﺎﻝ ﺍﻟﻤﺒﺮﻣﺞ ﺑﺸﻜﻞ ﻏﻴﺮ‬ ‫ﻋﺮﺽ"ﻣﻌﺎﻣﻞ ﺍﻟﻘﺪﺭﺓ )‪phi‬‬ ‫‪10‬‬
‫ﺻﺤﻴﺢ‪.‬‬ ‫‪ "(cos‬ﺃﻗﻞ ﻣﻦ ﻋﺎﻣﻞ ﺍﻟﻘﺪﺭﺓ‬
‫ﺗﺤﻘﻖﻣﻤﺎ ﺇﺫﺍ ﺗﻢ ﺗﻨﺸﻴﻂ ﻣﻮﺻﻼﺕ‬ ‫ﺧﻄﺄﻓﻲ ﺩﺍﺉﺮﺓ ﺍﻟﺘﺤﻜﻢ‪.‬‬ ‫ﺍﻟﻤﺴﺘﻬﺪﻑﺑﺎﻟﺮﻏﻢ ﻣﻦ ﺃﻥ‬
‫ﺍﻟﻤﻜﺜﻒ‪.‬‬
‫ﺗﺤﻘﻖﻣﻦ ﺍﻟﺼﻤﺎﻣﺎﺕ ﻭﺍﻟﺘﻼﻣﺴﺎﺕ ﺍﻟﺨﺎﺻﺔ‬ ‫ﺧﻄﺄﻓﻲ ﺩﺍﺭﺓ ﺍﻟﻤﻜﺜﻒ‪.‬‬ ‫ﺗﺘﺎﺑﻊﺍﻟﺘﺤﻜﻢ ﻟﺪﻳﻪ‬
‫ﺑﻤﻮﺻﻼﺕﺍﻟﻤﻜﺜﻒ ﻭﺭﺑﻤﺎ ﺍﻣﺘﺼﺎﺹ ﺍﻟﺘﻴﺎﺭ‪ .‬ﻗﻢ‬ ‫ﺗﺤﻮﻟﺖﻋﻠﻰ ﺟﻤﻴﻊ ﺍﻟﻤﺮﺍﺣﻞ‬
‫ﺑﻘﻴﺎﺱﺍﻟﺘﻴﺎﺭ ﻟﻜﻞ ﻣﺮﺣﻠﺔ ﻣﻦ ﻣﺮﺍﺣﻞ ﺍﻟﻤﻜﺜﻒ‬
‫ﺑﻤﻘﻴﺎﺱﺗﻴﺎﺭ ﻣﺜﺒﺖ ﻋﻠﻰ ﺍﻟﻤﺸﺒﻚ‪.‬‬

‫ﺍﺿﻐﻂﻋﻠﻰ ﺯﺭ "‪ "Set‬ﻭﺍﻗﺮﺃ ﺍﻟﻨﻘﺺ ﻓﻲ ﺍﻟﻄﺎﻗﺔ‬ ‫ﺍﻟﻨﻈﺎﻡﺍﻷﺻﻐﺮ‪.‬‬


‫ﻣﻦﺍﻟﺸﺎﺷﺔ‪.‬‬
‫ﻛﺮﺭﻋﻤﻠﻴﺔ ﺗﺤﺪﻳﺪ ﺍﻟﻬﻮﻳﺔ‪.‬‬ ‫ﻓﺸﻞﺗﻠﻘﺎﺉﻲ‬
‫ﺗﻌﺪﻳﻞ‪.‬‬
‫ﺍﺿﺒﻂﻋﺎﻣﻞ ‪ c / k‬ﻭﻓﻘﺎً ﻟﻠﺠﺪﻭﻝ‪.3‬‬ ‫ﺗﻢﺗﻌﻴﻴﻦ ﻋﺎﻣﻞ ‪ c / k‬ﻋﻠﻰ ﻗﻴﻤﺔ ﻋﺎﻟﻴﺔ ﺟﺪﺍً‪.‬‬ ‫ﻻﻳﻘﻮﻡ ﻣﺮﺣﻞ ﺍﻟﺘﺤﻜﻢ ﺑﺈﻳﻘﺎﻑ‬ ‫‪11‬‬
‫ﺗﺸﻐﻴﻞﺟﻤﻴﻊ ﺍﻟﻤﺮﺍﺣﻞ ﺃﺛﻨﺎء‬
‫ﺍﺿﻐﻂﻋﻠﻰ ﺯﺭ "ﺭﺟﻞ"‪.‬‬ ‫ﻣﺮﺣﻞﺍﻟﺘﺤﻜﻢ ﻓﻲ ﺍﻟﻮﺿﻊ ﺍﻟﻴﺪﻭﻱ‪.‬‬ ‫ﺃﻭﻗﺎﺕﺍﻧﺨﻔﺎﺽ ﺍﻟﺤﻤﻞ ﺃﻭ‬
‫ﺇﻳﻘﺎﻑﺗﺸﻐﻴﻞ ﺍﻟﻤﻨﺸﺄﺓ‪.‬‬
‫ﺍﻹﺻﺪﺍﺭ‪V2.10 ab SW 1.21‬‬

‫‪36‬‬
‫ﻳﻼﺣﻆ‪:‬‬

‫‪37‬‬
‫ﻣﺮﺣﻞﺍﻟﺘﺤﻜﻢ ﻓﻲ ﺍﻟﻘﺪﺭﺓ ﺍﻟﺘﻔﺎﻋﻠﻴﺔ ‪RM 9606‬‬
‫ﺑﺮﻧﺎﻣﺞﺍﻟﻤﺒﻴﻌﺎﺕ‬

‫ﺗﺨﻀﻊﻟﻠﺘﻐﻴﻴﺮ ﺍﻟﻔﻨﻲ ‪/ 05/06 / 7779 / ab V1.21 / V2.10‬‬


‫‪FRAKO55-02004‬‬
‫ﻣﻜﺜﻔﺎﺕﺍﻟﻘﺪﺭﺓ ﻷﻧﻈﻤﺔ ﺗﺼﺤﻴﺢ ﻣﻌﺎﻣﻞ‬
‫ﺍﻟﻘﺪﺭﺓﺫﺍﺕ ﺍﻟﺠﻬﺪ ﺍﻟﻤﻨﺨﻔﺾ‬
‫ﺃﻧﻈﻤﺔﺗﺼﺤﻴﺢ ﻋﺎﻣﻞ ﺍﻟﻘﺪﺭﺓ ﻣﻊ ﺍﻟﻤﻔﺎﻋﻼﺕ ﻭﺣﺪﺍﺕ ﻷﻧﻈﻤﺔ‬
‫ﺗﺼﺤﻴﺢﻣﻌﺎﻣﻞ ﺍﻟﻘﺪﺭﺓ ﺍﻟﻤﺮﺷﺤﺎﺕ ﺍﻟﻨﺸﻄﺔ‬

‫ﺗﻌﻮﻳﺾﺩﻳﻨﺎﻣﻴﻜﻲ ﻟﻠﺘﻮﺍﻓﻘﻴﺎﺕ ﻣﺮﺣﻼﺕ ﺍﻟﺘﺤﻜﻢ‬


‫ﻓﻲﺍﻟﻘﺪﺭﺓ ﺍﻟﺘﻔﺎﻋﻠﻴﺔ‬
‫ﺃﻧﻈﻤﺔﻣﺮﺍﻗﺒﺔ ﺍﻟﻄﻠﺐ ﺍﻟﻘﺼﻮﻯ‪ .‬ﺃﺩﻭﺍﺕ‬
‫ﺍﻟﻤﺮﺍﻗﺒﺔﺍﻟﺮﺉﻴﺴﻴﺔ‪ .‬ﺗﺨﺼﻴﺺ ﺍﻟﺘﻜﻠﻔﺔ‬

‫ﺃﻧﻈﻤﺔﺇﺩﺍﺭﺓ ﺍﻟﻄﺎﻗﺔ‬

‫ﺍﻟﺠﻮﺩﺓﻫﻲ ﺷﻌﺎﺭﻧﺎ ﺍﻟﺠﻮﺩﺓ ﻟﻬﺎ ﺍﺳﻢ‬


‫ﻧﺤﻦﺣﺎﺻﻠﻮﻥ ﻋﻠﻰ ﺷﻬﺎﺩﺍﺕ‬
‫‪ ISO9001‬ﻭ ‪ISO 14001‬‬

‫‪38‬‬