TITLE :______________________________________________
CLO3 Demonstrate an understanding and commit to professional ethics and responsibilities of engineering norms and sustainable energy in electrical wiring
during performance single phase domestic task. GENERIC
A3 Valuing (explain, display, express, report, respect, complete, work, organize, study, read, share & exc.) SKILL
PLO8 Ethics: Understand and commit to professional ethics and responsibilities and norms of technician practice
Total
03DET
21F102 MUHAMMAD IRFAN BIN
1 1 ROSLI
2
3
PRACTICAL SKILL ASSESSMENT RUBRIC PRACTICAL WORKS [1/2/3/4/5/6] DET 10022 – ELECTRICAL WIRING
Score description
Aspect
Not Achieved Not Yet Competent Competent Highly Competent Outstanding
1 2 3 4 5
Did not demonstrate proper Only demonstrated some Demonstrated some safety Demonstrated proper safety Demonstrated proper safety
Practice Proper safety practices safety practices practices after he/she was practices most of the times practices most of the times and
Safety reminded by the lecturer ensured they were practiced by
others in the group
Student was Student was able Student was able Student was able to Student was able to
Layout / Wiring UNABLE to draw with the draw with the accurate to draw with the accurate draw with the accurate draw with the accurate
Diagram / Circuits accurate measuring measuring measuring more than ½ but measuring with help of the measuring WITHOUT the help
Diagram less than ½ less than ¾ accuracy lecturer. of the lecturer
Fail to connect accessories Has great difficulty to Able to connect Able to connect Able to connect accessories
connect accessories accessories (measurement, accessories (measurement, (measurement, secure, level)
Accessories and (measurement, secure, secure, level) accurately secure, level) accurately accurately without any
Tools level) despite the assistance with some assistance from with minimum assistance assistance
given by the lecturer. lecturer from lecturer
Student UNABLE to Student ABLE to Student ABLE to Student ABLE to Student ABLE to install
install NONE of the wiring install of the wiring less install of the wiring than install of the wiring of the wiring according to the
correctly than 50% part of wiring & 50% but less than 75% part according to the schematic schematic diagram WITHOUT
more than 50% usage of of wiring. 50% correct diagram WITH the help of the help of the lecturer &
Wiring Installation
extra cable length of extra cable. the lecturer & Correct Correct length of extra cable.
length of extra cable.
Below 50% correct 50 to 70% correct Correct cable termination Strong termination on every Strong termination on every
termination. termination on every terminal. Cable terminal (Not loose). Cable terminal (Not loose). Cable that
Cable that join together . Cable that join together that join together NOT be that join together must be join together must be twisted.
NOT be twisted. More than NOT be twisted. Below twisted. 50% unsafe expose twisted 20% unsafe expose No unsafe expose LIVE
Wiring Termination 50% unsafe expose LIVE 50% unsafe expose LIVE LIVE conductor seen on LIVE conductor seen on conductor seen on every
conductor seen on conductor seen on termination. termination. termination.
termination. termination.
None part of the practical Only a small part of the Half of the practical The practical completed Practical successfully completed
completed within the time practical completed within completed within the time within the time frame in the given time frame
Time Frame frame. the time frame. frame WITH the help of the WITHOUT the help of the
lecturer. lecturer.
Student does not do the Student does the Student DOES PART of Student do Inspection & Student do Inspection &
Inspection & Testing Inspection & Testing the Inspection & Testing Testing correctly WITH the Testing correctly WITHOUT
Inspection & Testing correctly AT ALL correctly correctly & wiring circuit help of the lecturer the help of the lecturer
was partly operational
Circuit was Totally not Circuit was partly Circuit was partly Circuit was fully Circuit was fully Operational &
Circuit Operational Operational & not Completed BUT not Operational & partly Operational & partly Completed
& Completed Completed Operational Completed Completed Completed
Student able to achieve Student able to achieve Student able to achieve part Student able to achieve all Student able to achieve all
NONE of the intended PART of the intended of the intended results intended results with intended results with accurate
Recording & results results WITHOUT accurate WITH accurate readings, accurate readings and readings and Recording &
Interpreting the readings & Interpreting the Recording & Interpreting Recording & Interpreting Interpreting the result
result the result the result WITH the help of WITHOUT the help
result the lecturer of the lecturer
Clean-up procedures Clean-up procedures are Clean-up procedures are Clean-up Clean-up
Housekeeping/ are seldom used often missed generally used procedures are consistently procedures are most consistently
Cleanliness used used
Wired a 3 socket outlet 13A with ring circuit and one switch one pole one way
control one flourecent lamp by using consumer unit .
EQUIPMENT :
Consumer unit / S1
Ring circuit 3 X 13A SOCKET DFB
OUTLET
PROCEDURES :
MCB MCB
6A
32A
N E
Power Circuit
NO. Meter
Power Circuit - Ring Circuit section Readings ( ohm )
s/o s/o s/o
1 2 3
1. From Phase wire ‘L’ ( MCB 32A ) to every ‘L’ terminal 13A s/o 0.3 0.3 0.3
2. From Neutral wire ‘N’ to every terminal ‘N’ 13A socket outlet 0.4 0.3 0.4
3. From E.C.C to every ‘E’ terminal 13A socket outlet 0.3 0.3 0.3
b. Lighting Circuit
NO Meter Reading
CONTINUITY ( ohm )
1. Continuity L1 to L2 0.4
2. Continuity N1 to N2 0.4
3. Continuity E1 to E2 0.4
INSPECTION AND TESTING :
4. CONTINUITY OF THE PROTECTION WIRE / ECC TEST . Use your multimeter to do the
testing.