Trend Plot Waterfall Plot

Finding from trend plot and waterfall plot


VT-10132X / Y VT-10132X VT-10132Y
April 30th, 2021
a) Since both vibration (VT-10132X and VT-10132Y) reached to
Tripped at Vibration peak of extremely Vibration peak of extremely HH alarm set value (88 micrometer), 101-J was tripped
low frequency was low frequency was
11:20:29 suddenly appeared just suddenly appeared just by 2 out of 2 logic control.
before compressor trip. before compressor trip.

1X 2X 1X 2X b) The unbalance vibration (1X, 2X) was small and stable,


but the vibration of extremely low frequency was suddenly appeared
just before compressor trip.

Tripped at Tripped at
11:20:29 11:20:29

May 3rd, 2021


a) Since both vibration (VT-10132X and VT-10132Y) reached to
Tripped at Vibration peak of extremely Vibration peak of extremely
HH alarm set value (88 micrometer), 101-J was tripped
22:08:32 low frequency was low frequency was by 2 out of 2 logic control.
observed observed
before/after
1X compressor
2X trip. before/after compressor trip.
1X 2X
b) The unbalance vibration (1X, 2X) was small and stable,
but the vibration of extremely low frequency was confirmed
Tripped at 22:08:32 Tripped at 22:08:32 before/after compressor trip.

May 4th, 2021


a) Since both vibration (VT-10132X and VT-10132Y) reached
Tripped at Vibration peak of extremely Vibration peak of extremely to HH alarm set value (88 micrometer), 101-J was tripped
08:20:46 low frequency was
observed
low frequency was
observed
by 2 out of 2 logic control.
before/after
1X compressor
2X trip. before/after
1X compressor
2X trip.

b) The unbalance vibration (1X, 2X) was stable


without abnormal changing, but the vibration of extremely
Tripped at 08:20:46 Tripped at 08:20:46
low frequency was confirmed before / after compressor trip.

May 8th, 2021


a) Since both vibration (VT-10132X and VT-10132Y) reached to
Tripped at Tripped at 02:59:35 Tripped at 02:59:35 HH alarm set value (88 micrometer), 101-J was tripped
22:08:32 1X 2X 3X 1X 2X 3X by 2 out of 2 logic control.

4X 4X b) The peak for integral multiple of unbalance vibration (1X, 2X, 3X, 4X)
was observed and unstable before compressor trip.

c) The vibration peak of extremely low frequency was not observed.


Vibration peak of extremely Vibration peak of extremely
low frequency was not low frequency was not
observed. observed.

May 9th, 2021


a) The compressor was restarted on May 9th 2021,
Not received Not received Not received but it was tripped.
After trip of compressor, No.1 pinion rotor moved in the axial direction.

Table .2 Comparison of vibration data From April 30th to May 8th, 2021