Make sure your Adobe Acrobat Reader is up

SCHEMATIC FEATURES AND TIPS


to date in order to access the latest features
of this schematic.

GET
Adobe Acrobat Reader

SAVE
a copy of this schematic

THE BOOKMARKS PANEL WILL ALLOW YOU TO THE FUNCTION ISOLATION TOOLS ISOLATE
QUICKLY NAVIGATE TO POINTS OF INTEREST. CIRCUITS FOR TRACING HYDRAULIC LINES

Function Isolation Tools

Grids On/Off

All Circuits Off


STANDARD VIEW
All Circuits On

021 (Orange) (Pilot Pump Output)

032 (Red) (Main Pump Output)

577 (Lt Green) (Drain/Return Line)

Machine Views

Machine View - Front

Machine View - Rear

Implement Stack 021 (Orange) (Pilot Output)


CIRCUIT ISOLATED
CLICK HERE TO VIEW THE SCHEMATIC
UTILIZE HYPERTEXT TO NAVIGATE TO COMPONENTS AND THEIR MACHINE LOCA- SYMBOLS AND DEFINITIONS PAGE
TION QUICKLY. HYPERTEXT IS INDICATED BY TEXT THAT IS BLUE AND UNDERLINED. ELECTRICAL SYMBOLS

Pressure Temperature Level


Switch Switch Switch Circuit Breaker

BASIC HYDRAULIC SYMBOLS

Fluid Pump Spring


Variability
Conditioner or Motor (Adjustable)

HOTKEYS (Keyboard Shortcuts)

FUNCTION KEYS
Zoom In “CTRL” / “+”
Zoom Out “CTRL” / “-”
Fit to Page “CTRL” / “0” (zero)
Hand Tool “SPACEBAR” (hold down)
Find “CTRL” / “F”
WHEN ONLY ONE CALLOUT IS SHOWING ON A Search “CTRL” / “SHIFT” / “F”

MACHINE VIEW, CLICKING ON THIS BUTTON WILL


VIEW ALL CALLOUTS MAKE ALL OF THE CALLOUTS VISIBLE. THIS
Due to different monitor sizes and PDF reader
preferences there may be some variance in linked
BUTTON IS TYPICALLY LOCATED IN THE TOP RIGHT schematic locations. This document is best viewed at
CORNER OF EVERY MACHINE VIEW PAGE. a screen resolution of 1024 X 768.

© 2022 Caterpillar. All Rights Reserved. CAT, CATERPILLAR, LET’S DO THE


WORK, their respective logos, “Caterpillar Corporate Yellow”, the “Power Edge”
and Cat “Modern Hex” trade dress as well as corporate and product identity used
herein, are trademarks of Caterpillar and may not be used without permission.
SCHEMATIC SYMBOLS AND DEFINITIONS
VALVES INTERNAL PASSAGEWAYS PUMPS BASIC HYDRAULIC
ENVELOPES FLOW IN ONE
DIRECTION
FLOW ALLOWED IN
EITHER DIRECTION
PARALLEL
FLOW
CROSS
FLOW
FIXED DISPLACEMENT
COMPONENT SYMBOLS

One Position Two Position Three Position Unidirectional Bidirectional Pump


Infinite Two Three Variability
Positioning Position Position or Motor
PORTS VARIABLE DISPLACEMENT
NON- COMPENSATED

CYLINDERS Fluid Spring


(Adjustable)
Two-way Three-Way Four-Way Conditioner
Unidirectional Bidirectional
CONTROL
AB AB
Single Acting Double Acting
MOTORS Pressure
FIXED DISPLACEMENT Spring
P T P T Compensation
Normal Position Shifted Position Infinite Position

CHECK
Control
ACCUMULATORS Unidirectional Bidirectional
Valves
Line Restriction
(Variable)
VARIABLE DISPLACEMENT
Basic Spring Shuttle NON- COMPENSATED
Pilot
Symbol Loaded Line Restriction
Controlled Spring Loaded Gas Charged Restriction
(Fixed)

Unidirectional Bidirectional

PILOT CONTROL Line Restriction


MAIN AUX.

2-Section
RELEASED PRESSURE Variable and Pressure
ROTATING SHAFTS Compensated
Pump

External Return Internal Return Unidirectional Bidirectional


REMOTE SUPPLY PRESSURE Attachment Pump: Variable and
Pressure Compensated

Internal
Simplified Complete Supply Pressure Hydraulic Pneumatic
Energy Triangles

COMBINATION CONTROLS
LINES MEASUREMENT

Solenoid Solenoid Solenoid Solenoid and Servo Thermal Detent Crossing Joining
or Manual and Pilot Pilot or Manual Pressure Temperature Flow

MANUAL CONTROL FLUID STORAGE RESERVOIRS

Push-pull Lever Manual Shutoff General Manual Push Button Pedal Spring Vented Pressurized Return Above Fluid Level Return Below Fluid Level

HYDRAULIC SYMBOLS - ELECTRICAL ELECTRICAL SYMBOLS


G
M T

Pressure Temperature Level Flow


Transducer Transducer Generator Electric Pressure Pressure Switch Temperature Electrical
Switch Switch Switch Switch Circuit Breaker
(Fluid) (Gas / Air) Motor Switch (Adjustable) Switch Wire

BASIC ELECTRICAL COMPONENT SYMBOLS HARNESS AND WIRE SYMBOLS


Wire, Cable, or Harness Assembly Identification:
Fuse: A component in an electrical circuit that will open the circuit if too much current flows through it. Includes Harness Identification Letters and Harness
Connector Serialization Codes (see sample).
Switch (Normally Open): A switch that will close at a specified point (temp, press, etc.). The circle indicates
that the component has screw terminals and a wire can be disconnected from it.
AG-C4 L-C12
Switch (Normally Closed): A switch that will open at a specified point (temp, press, etc.). 111-7898 3E-5179
No circle indicates that the wire cannot be disconnected from the component. Part Number: for 1
Connector Plug
Ground (Wired): This indicates that the component is connected to a grounded wire. 2
The grounded wire is fastened to the machine.
Plug Receptacle
Pin or Socket Number
Ground (Case): This indicates that the component does not have a wire connected to ground.
It is grounded by being fastened to the machine. Harness Identification Letter(s): (A, B, C, AA, AB, AC, ...)
Harness Connector Serialization Code: The "C" stands for
"Connector" and the number indicates which connector in the
Reed Switch: A switch whose contacts are controlled by a magnet. A magnet closes the contacts of
harness (C1, C2, C3, ...)
a normally open reed switch; it opens the contacts of a normally closed reed switch.
L-C12
3E-5179
Sender: A component that is used with a temperature or pressure gauge.
The sender measures the temperature or pressure. 5A
T Its resistance changes to give an indication to the gauge of the temperature or pressure. Component
Fuse (5 Amps) 9X-1123 Part Number
Relay (Magnetic Switch): A relay is an electrical component that is activated by electricity. 325-AG135 PK-14
It has a coil that makes an electromagnet when current flows through it. Harness identification code:
This example indicates wire group 325, Wire Gauge*
The electromagnet can open or close the switch part of the relay. wire 135 in harness "AG". Wire Color
*Wire gauge is shown in AWG (American Wire Gauge)
Solenoid: A solenoid is an electrical component that is activated by electricity. but could also be shown in metric denoted with mm
It has a coil that makes an electromagnet when current flows through it.
The electromagnet can open or close a valve or move a piece of metal that can do work. 1 Deutsch connector: Typical representation
of a Deutsch connector. The plug contains all
2 sockets and the receptacle contains all pins.
Magnetic Latch Solenoid: An electrical component that is activated by electricity and held latched by a
permanent magnet. It has two coils (latch and unlatch) that make electromagnet 1 Sure-Seal connector: Typical representation
when current flows through them. It also has an internal switch that places of a Sure-Seal connector. The plug and receptacle
2 contain both pins and sockets.
the latch coil circuit open at the time the coil latches.

© 2022 Caterpillar. All Rights Reserved. CAT, CATERPILLAR, LET’S DO THE


WORK, their respective logos, “Caterpillar Corporate Yellow”, the “Power Edge”
and Cat “Modern Hex” trade dress as well as corporate and product identity used
herein, are trademarks of Caterpillar and may not be used without permission.
M0128464-02
December 2022

336 and 340 Excavator


Hydraulic System
ZFC1-UP
MZR1-UP
RDL1-UP
SYL1-UP
XBZ1-UP
WFK1-UP
GDZ1-UP
EFH1-UP
FKN1-UP
ZDP1-UP
WGK1-UP
NDW1-UP
DYJ1-UP

Volume 1 of 2: Main Schematic


Volume 2 of 2: Attachment

PUBLICATIONS.CAT.COM
© 2022 Caterpillar. All Rights Reserved. CAT, CATERPILLAR, LET’S DO THE WORK, their respective logos, “Caterpillar Corporate Yellow”, the “Power Edge”
and Cat “Modern Hex” trade dress as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.
Caterpillar: Non-Confidential
COMPONENT LOCATION
VOLUME 1 - MAIN SCHEMATIC

Schematic Machine
Description
Location Location
Accumulator Gp - Hydraulic (Charged) D-11 1
Accumulator Gp - Hydraulic (Uncharged) I-10 2
Cylinder Gp - Boom LH J-6 3
Cylinder Gp - Boom RH J-6 28
Cylinder Gp - Bucket J-9 4
Cylinder Gp - Stick J-8 5
Filter Gp - Oil (Drain) A-8 6
Filter Gp - Oil (Hydraulic Return) A-9 7
Motor Gp - Piston (Fan, Suction) C-9 8
Motor Gp - Swing C-11 9
Motor Gp - Travel (LH) C-16 10
Motor Gp - Travel (RH) C-14 11
Pump Gp - Hydraulic (Fan) C-4 12
Pump Gp - Main Hydraulic C-7 13
Sensor Gp - Pressure (Boom Cylinder Head End) I-6 14
Sensor Gp - Pressure (Boom Cylinder Rod End) I-7 26
Sensor Gp - Pressure (Bucket Cylinder Head End) I-6 15
Sensor Gp - Pressure (Bucket Cylinder Rod End) D-6 16
Sensor Gp - Pressure (Pump P1) D-7 17
Sensor Gp - Pressure (Pump P2) D-8 18
Sensor Gp - Pressure (Stick Cylinder Head End) I-7 19
Sensor Gp - Pressure (Stick Cylinder Rod End) D-11 20
Swivel Gp A-14 21
Valve Gp - Check (Return) I-12 22
Valve Gp - Check (Travel Pilot) E-11 23
Valve Gp - Main Control E-12 24
Valve Gp - Solenoid (Heavy Lift) I-4 25
Valve Gp - Solenoid (Fine Swing) A-11 27
COMPONENT LOCATION
VOLUME 2 - ATTACHMENT

Schematic Machine
Description
Location Location
Cylinder Gp - Boom LH J-6, H-5 51
Cylinder Gp - Boom RH J-5, H-4 88
Cylinder Gp - Quick Coupler D-6 89
Cylinder Gp - Stick (SLCV) J-3 53
Filter Gp - Oil Hydraulic (Combined Function Electric Relief) B-10 54
Filter Gp - Oil Hydraulic (Manual Relief) B-11 55
Filter Gp - Oil Hydraulic (One Way / One Pump) D-10 56
Motor Gp - Piston F-8 77
Motor Gp - Piston (Reversing Fan) E-7 57
Pump Gp - Gear (Medium Circuit) I-16 58
Sensor Gp - Pressure (Boom Cylinder Head End) (BLCV) I-5
59
Sensor Gp - Pressure (Boom Cylinder Head End) (Smart Boom) F-4
Sensor Gp - Pressure (Boom Cylinder Rod End) (BLCV) I-6
61
Sensor Gp - Pressure (Boom Cylinder Rod End) (Smart Boom) F-4
Sensor Gp - Pressure (Squeeze Head End) (Electric Relief) B-8 63
Sensor Gp - Pressure (Squeeze Head End) (Manual Relief) B-13 64
Sensor Gp - Pressure (Squeeze Rod End) (Electric Relief) B-8 65
Sensor Gp - Pressure (Squeeze Rod End) (Manual Relief) B-12 66
Sensor Gp - Pressure Pump 2 Output (QC) B-3 67
Valve As - Ball (Manual Relief) A-11 68
Valve Gp - Bank 2 (Medium Pressure) J-11 69
Valve Gp - Check (Quick Coupler) B-3 71
Valve Gp - Check (Smart Boom Float Up) E-5 72
Valve Gp - Check and Relief (SLCV) I-3 70
Valve Gp - Check LH (BLCV) J-7
73
Valve Gp - Check LH (Smart Boom Load Control) G-5
Valve Gp - Check RH (BLCV) J-5
75
Valve Gp - Check RH (Smart Boom Load Control) G-3
Valve Gp - Control (Smart Boom) F-3 78
Valve Gp - Main Control (Manual/Electric Relief) A-15 79
Valve Gp - Main Control (One Way / One Pump) E-11 80
Valve Gp - Shuttle (Smart Boom) G-2 81
Valve Gp - Solenoid (Aux Hydraulic Boost Flow) (QC) C-5 82
Valve Gp - Solenoid (Medium Pressure) H-15 83
Valve Gp - Solenoid (Smart Boom Float Down) G-2 84
Valve Gp - Solenoid Pressure Reducing (QC) C-5 85
Valve Gp - Solenoid Variable Relief 1 (Electric) B-10 86
Valve Gp - Solenoid Variable Relief 2 (Electric) A-8 87
TAP LOCATION
VOLUME 1 - MAIN SCHEMATIC

Tap Schematic
Description
Number Location
AA Pilot Pressure (Main Control Valve) E-12
BB Pilot Pressure (Main Pump) C-5
CC Case Drain Pressure A-5
DD Case Drain Pressure (Pump Gp - Fan) A-4
TAP LOCATION
VOLUME 2 - ATTACHMENT

Tap Schematic
Description
Number Location
MA Attachment Valve 4 Extend Pressure (Medium Circuit) H-14
MB Attachment Valve 4 Retract Pressure (Medium Circuit) H-13
MP Medium Pressure I-10
SP Stick Load Control Pressure J-1
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

(4) CYLINDER GP - BUCKET (5) CYLINDER GP - STICK (3) CYLINDER GP - BOOM (LH) (28) CYLINDER GP - BOOM (RH)
587-1189 587-1183 587-1231 587-1231
M0128464-02 VOL 1 of 2

BR2
J J
(Dimensions: 56 inches x 35 inches)

AR2

AL3 BL3 BR3 AR3


(26) SENSOR GP - PRESSURE (14) SENSOR GP - PRESSURE
BOOM CYLINDER ROD END BOOM CYLINDER HEAD END
AUX 344-7392 344-7392
RETURN MPV-T QC-T
NOTE F NOTE J NOTE K (22) VALVE GP -
CHECK (RETURN)
CV-T 490-3958 (15) SENSOR GP - PRESSURE HPi
I (25) VALVE GP - SOLENOID I
FAN-T SWG (2) ACCUMULATOR GP (BUCKET CYLINDER HEAD END)
2 SPEED HEAVY LIFT (HEAVY LIFT)
TRAVEL PRKG BK HYDRAULIC (UNCHARGED) 344-7392 SOLENOID
D (19) SENSOR GP - PRESSURE 524-0912
CONTROL CONTROL 567-8764
C (STICK CYLINDER HEAD END) A
HPi
AL2 AL1 344-7392 AR1 AR3
AL3 AR2

Pi5 SG Pi4 PAC AL3 AL2 AL1 AR1 BKHS AR2 AR3 BLCV-Pi
NOTE M
42 Page,

B 6 24 NOTE N P T
7 11 13 18 23 16 12
21 CV-Dr
HPi SHS

BPi Dr1 MU
H H

Dr2 Pi2 Dr3


A MU Pi3
T <UP> <IN> <OUT> <L> <BKWD> <BKWD> <CLOSE> <DOWN> <UP> <OUT>
Dr8
Dr4

CV-Pi7

TRAVEL(R)
Pi6

BUCKET

BOOM(1)

STICK(2)
Pi7 NOTE M

SWING

TRAVEL(L)

STR-TRAVEL
STICK(1)
BOOM(2)
G Dr6 G

Pi10

STK UNL
SWG PRI
IDENT ELEC DEVICE NAME
F F
24 STRAIGHT TRAVEL SOLENOID
Dr7 Dr10
23 LEFT TRAVEL FORWARD SOLENOID
<OUT> <IN> <R> <FWD> <FWD> <OPEN> <UP> <DOWN> <IN>
22 LEFT TRAVEL BACKWARD SOLENOID
Dr9 Pi9 Pi1 Dr5 21 RIGHT TRAVEL FORWARD SOLENOID
CV-Dr5 20 RIGHT TRAVEL BACKWARD SOLENOID
(24) VALVE GP - MAIN CONTROL NOTE M
512-2722 (STD) AA P2 P1 19 SWING RIGHT SOLENOID
504-1792 (HEAVY LIFT) P2S P1S
P2 P1 18 SWING LEFT SOLENOID
E 17 BUCKET CYLINDER RETRACT SOLENOID E
8 5 17
9 14 19 20 22 10 15 16 BUCKET CYLINDER EXTEND SOLENOID
Pi8 SRS BL3 SPi BL2 BL1 bST BR1 BR2 BKRS BR3 15 STICK CYLINDER EXTEND #2 SOLENOID
(23) VALVE GP - CHECK-E SLCV-Pi 14 STICK CYLINDER EXTEND #1 SOLENOID
6E-4701 BL3 NOTE R BL2 BL1 bST BR1 BR2 BR3
(16) SENSOR GP - PRESSURE 13 STICK CYLINDER RETRACT SOLENOID
(18) SENSOR GP - PRESSURE (17) SENSOR GP - PRESSURE
(BUCKET CYLINDER ROD END)
(PUMP P2) (PUMP P1)
344-7392
12 BOOM CYLINDER RETRACT SOLENOID
Psv 344-7392 344-7392
(1) ACCUMULATOR GP -
(20) SENSOR GP - PRESSURE 11 BOOM CYLINDER EXTEND #2 SOLENOID
(STICK CYLINDER ROD END)
D HYDRAULIC (CHARGED)
245-2975
344-7392 10 BOOM CYLINDER EXTEND #1 SOLENOID D

9 HYDRAULIC LOCK SOLENOID


8 SWING PRIORITY SOLENOID
7 SWING BRAKE SOLENOID
SWG
(10) MOTOR GP - TRAVEL (LH) (11) MOTOR GP - TRAVEL (RH) PRKG BK (9) MOTOR GP - SWING 6 TRAVEL SPEED SOLENOID
611-1187 611-1187 CONTROL 587-4946
TRAVEL MOTOR (LEFT) TRAVEL MOTOR (RIGHT) SWING MOTOR 5 STICK UNLOAD SOLENOID
(12) PUMP GP - HYDRAULIC
FAN-T FAN-P (8) MOTOR GP - PISTON (FAN, SUCTION) (FAN GROUP)
PG 598-7826 (FOR 340)
564-9802 (FOR 340)
A B 598-7820 (FOR 336)
C 564-9803 (FOR 336) C
Pi Pi SWG-Dr
DB
P1 P2 Psv MAIN HYDRAULIC
FAN-Dr
(13) PUMP GP - MAIN BB PUMP #2
ph2 A2
MU FAN-Dr HYDRAULIC a1 A1 ph1 a2 SOLENOID
NOTE B: FOR USE AS HEAVY LIFT
M L 568-3006
NOTE F: FOR USE AS AUXILIARY RETURN LINE
L1
SMB-T PA PB BLCV-Dr FAN PUMP NOTE J: FOR USE AS MEDIUM CIRCUIT
Dr(1) NOTE M NOTE M MAIN HYDRAULIC SOLENOID NOTE K: FOR USE AS QUICK COUPLER
Dr(1) NOTE N PUMP #1 SOLENOID
Dr(2) bST NOTE M: FOR USE AS SMART BOOM
Dr(2)
NOTE N: FOR USE AS BOOM LOWERING CHECK VALVE
G2 G1 G1 G2 CV-Dr3 SLCV-Dr FAN-P
a4 a5 NOTE P: FOR USE AS STICK LOWERING CHECK VALVE
NOTE M NOTE P B NOTE R: FOR DETAIL OF
B ADDITIONAL VALVE(1) WITH END COVER FOR ONE-WAY B
QC-Dr ONE PUMP
NOTE K DRAIN
FILTER LINE PATTERNS
P2 (LOWER) P1 (UPPER) P1 (LOWER) P2 (UPPER)
d P Pressure Line
HYDRAULIC CIRCUIT COLOR DESCRIPTIONS
A C Pilot / Load Sensing Pressure
CV-Dr PILOT CONTROL CIRCUIT
PUMP 1 OUTPUT
Drain / Return Lines
B D Dr HEAVY LIFT CONTROL CIRCUIT
TRAVEL LEFT CONTROL CIRCUIT
PA1 DE PB1 B1 ax S L2 L
FAN CONTROL CIRCUIT
Air Line
CV-T SUPPLY LINE

B' D' A Av DR Bv B STICK CONTROL CIRCUIT


Component Group

AL1 BR1 SWING CONTROL CIRCUIT


DRAIN / RETURN LINE
CALLOUTS

(6) FILTER GP - OIL (DRAIN)


SWING BRAKE CIRCUIT
A' C' CC
YY Taps (Pressure, Sampling, Sensor - by letter)

491-6075 DD PUMP 2 OUTPUT

BL1 d' P' AR1 TRAVEL SPEED CONTROL CIRCUIT


BUCKET CONTROL CIRCUIT
DL DL D Connectors (By letter)
TRAVEL RIGHT CONTROL CIRCUIT
Callout Number Component
BOOM CONTROL CIRCUIT (Machine Location from (52) VALVE GP - CONTROL Name

A SWG-Dr A
STRAIGHT TRAVEL CIRCUIT Component LocationsTable)
138-1234
FINE SWING
Part Number

BL2 AL2
(21) SWIVEL GP SOLENOID
2 SPEED 490-3995 (7) FILTER GP - OIL THIS SCHEMATIC IS FOR THE 336 AND 340 EXCAVATOR HYDRAULIC SYSTEM
DRAIN VOLUME 1 of 2: MAIN SCHEMATIC
TRAVEL (27) VALVE GP - SOLENOID (HYDRAULIC RETURN) Do not operate or work on this product unless you have
FILTER read and understood the instruction and warnings in the MEDIA NUMBER: M0128464-02
CONTROL (FINE SWING) 599-0905 relevant Operation and Maintenance Manuals and
relevant service literature. Failure to follow the instruc- SCHEMATIC PART NUMBER: 608-1285, CHANGE: 00, VERSION: HE
493-3208 NOTE B tions or heed the warnings could result in injury or
death. Proper care is your responsibility.
Components are shown installed on a fully operable machine with the key and engine off.
Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations.
Refer to the Parts Manual using a specific serial number prefix in SIS before ordering parts from this schematic.

16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

(69) VALVE GP - BANK-2 (51) CYLINDER GP - BOOM LH (88) CYLINDER GP - BOOM RH (53) CYLINDER GP - STICK
(MEDIUM CIRCUIT) 587-1231 587-1231 587-1183
A1 A2 Psv 310-0165 B
T2 Pi
M0128464-02 VOL 2 of 2

B SP
J J
(73) VALVE GP - CHECK LH (75) VALVE GP - CHECK RH
(BLCV) (BLCV)
(Dimensions: 56 inches x 35 inches)

518-1312 518-1312
<RET> B
Pa1 <EXT> Pb1 Pi SLCV-Pi
Pa1 Pb1
Dr S NOTE P
B B

B X2 Pi X2 Pi BLCV-Pi
B1 MPV-P X2 BLCV BLCV
<RET> B1 NOTE N
(58) PUMP GP - GEAR AL3
(MEDIUM CIRCUIT) X1 A Dr A Dr
X1 A Dr X1
493-3206
<EXT> A1 BR3
I I

S
DETAIL OF BOOM
(70) VALVE GP - CHECK
P
MPV-P LOWERING CHECK VALVE AND RELIEF (SLCV) A Dr
PLS AR3 518-1337
(61) SENSOR GP - (59) SENSOR GP -
MPV-T T1 PPS PRESSURE PRESSURE
NOTE J MP BLCV-Dr BL3
(BOOM CYLINDER (BOOM CYLINDER SLCV-Dr
42 Page,

NOTE N
ROD END) HEAD END) NOTE P
344-7392 344-7392
Pa1 Pb1
(83) MANIFOLD GP - SOL
(MEDIUM PRESSURE)
H 259-7430 MA MB BOOM LOWERING CHECK STICK LOWERING CHECK H
A2
B2 A1 B1 VALVE ATTACHMENT VALVE ATTACHMENT
ATTACHMENT VALVE #4 EXTEND ATTACHMENT VALVE #4 RETRACT
<EXT> <RET>
PRESSURE SOLENOID PRESSURE SOLENOID
(51) CYLINDER GP - BOOM LH (88) CYLINDER GP - BOOM RH
587-1231 587-1231 BLCV-Pi
P NOTE N

COVER

COVER
Pi6
MAIN CONTROL VALVE (81) VALVE GP - SHUTTLE

END

END
(73) VALVE GP - CHECK LH (75) VALVE GP - CHECK RH (SMART BOOM)
T Dr6 (SMART BOOM LOAD CONTROL) (SMART BOOM LOAD CONTROL) 164-6979
FAN-Dr (84) VALVE GP - SOLENOID
FAN-T 518-1312 518-1312 (BOOM FLOAT DOWN)
G 524-0911 G
MEDIUM CIRCUIT ATTACHMENT L A
B B
Pi X2 Pi T
X2 BLCV BLCV A1 CV-Dr5
COMBINED FUNCTION - MANUAL, ELECTRIC RELIEF, AND ONE-WAY/ONE PUMP ATTACHMENT NOTE M
X1 A Dr A Dr P
ATTACHMENT VALVE #1 EXTEND X1
PRESSURE SOLENOID Pi
ATTACHMENT VALVE #2 EXTEND ADDITIONAL VALVE (1)
PRESSURE SOLENOID WITH END COVER CV-Pi7
AR5 NOTE R NOTE M
B (59) SENSOR GP -
PRESSURE
F Dr2 AL5 AR5 MU Pi3 Dr3 (77) MOTOR GP - PISTON (BOOM CYL BLCV-Dr C F
Pi2 AR5
<EXT> 598-7826 (FOR 340) FAN-P HEAD) NOTE M
<EXT> 344-7392
Dr8 Dr4 AR3 (78) VALVE GP - CONTROL

COVER
AUX(1) (SMART BOOM) T
MAIN CONTROL VALVE Dr

END
W/ END COVER 522-7193
Pi7 FAN-P FAN-T
AUXILIARY(1)

Pi6 (61) SENSOR GP - PRESSURE


AUXILIARY(2)

(BOOM CYLINDER ROD)


Dr6 344-7392
(80) VALVE GP - MAIN CONTROL B A SMB-T
607-9626 B A NOTE M
607-9627 NOTE B
BR3
E (72) VALVE GP - CHECK Dr E
(SMART BOOM FLOAT UP)
FAN-Dr
L 297-0370
L1 (57) MOTOR GP - PISTON
CV-Dr3
(HYDRAULIC FAN)
Pi10 NOTE M
598-7823 (FOR 336)
SINGLE SINGLE (56) FILTER GP - HYDRAULIC OIL
(ONE-WAY/ONE PUMP) REVERSE FAN SMART BOOM
266-7913
Dr7 NOTE G ATTACHMENT ATTACHMENT
Dr10

<RET> <RET>
BL5 BR5 Dr5 AUX
D Dr9Pi9 D
RETURN
ATTACHMENT VALVE #1 RETRACT NOTE F NOTE B: FOR USE AS HEAVY LIFT
PRESSURE SOLENOID AR5 NOTE D: FOR DETAIL
(89) CYLINDER - QUICK COUPLER OF ADDITIONAL VALVE(1) FOR TCS
569-8001 NOTE E: FOR DETAIL
ATTACHMENT VALVE #2 RETRACT OF ADDITIONAL VALVE(2) FOR TCS
NOTE F: FOR USE AS AUXILIARY RETURN LINE
PRESSURE SOLENOID
NOTE G: FOR USE AS W/ HAMMER RETURN FILTER
(82) VALVE GP - SOLENOID NOTE J: FOR USE AS MEDIUM CIRCUIT
(AUX HYDRAULIC bST
DETAIL OF ADDITIONAL VALVE (2) DETAIL OF ADDITIONAL VALVE (1) ONE-WAY/ONE PUMP BOOST FLOW)
NOTE K: FOR USE AS QUICK COUPLER
NOTE M: FOR USE AS SMART BOOM
NOTE E NOTE D 524-0912 A NOTE N: FOR USE AS BOOM LOWERING CHECK VALVE
NOTE P: FOR USE AS STICK LOWERING CHECK VALVE
NOTE R: FOR DETAIL OF
ADDITIONAL VALVE(1) WITH END COVER FOR ONE-WAY/
C ONE PUMP C
(85) VALVE GP - SOLENOID
AND PRESSURE REDUCING P T HYDRAULIC CIRCUIT COLOR DESCRIPTIONS
B A QC-Dr
514-7723 FOR UQC (CW) PILOT CONTROL CIRCUIT
NOTE K PUMP 1 OUTPUT
SINGLE SINGLE 549-7972 FOR HQC (CPG) FAN CONTROL CIRCUIT

SINGLE
MEDIUM CIRCUIT ATTACHMENT
SINGLE
Pi2
QUICK COUPLER CONTROL CIRCUIT
DOUBLE DOUBLE SUPPLY LINE

DOUBLE DOUBLE STICK CONTROL CIRCUIT


TOOL CONTROL SYSTEM ATTACHMENT
(64) SENSOR GP - PRESSURE (63) SENSOR GP - PRESSURE SWING CONTROL CIRCUIT

SQUEEZE HEAD END (66) SENSOR GP - PRESSURE DRAIN / RETURN LINE


(SQUEEZE HEAD END)

COVER

COVER
ADDITIONAL
PUMP 2 OUTPUT

338-6971 SQUEEZE ROD END BOOM CONTROL CIRCUIT


338-6971 MAIN CONTROL VALVE

END

END
AL5 AR5 VALVE (1) 338-6971 (86) VALVE GP - (VARIABLE
RELIEF VALVE 1 SOL) P1
ADDITIONAL VALVE (2) NOTE D (55) FILTER GP - HYDRAULIC LINE PATTERNS
NOTE E OIL (MANUAL RELIEF) 297-0265 G Pressure Line
AL5 AR5 QUICK COUPLER
266-7913 SOLENOID #2 bST P2S Pilot / Load Sensing Pressure
B (54) FILTER GP - HYDRAULIC OIL (65) SENSOR GP - PRESSURE B
NOTE G R Drain / Return Lines
(ELECTRIC RELIEF) (SQUEEZE ROD END)
COVER

COVER

S1 S2 bST
AUX(2)

AUX(1)

266-7913 P1 QC-P Air Line


MAIN CONTROL VALVE 338-6971
END

END

NOTE G Component Group


AUX P2 G A(P) B(T) CALLOUTS
RETURN QUICK COUPLER
R SOLENOID #1 YY Taps (Pressure, Sampling, Sensor - by letter)

BL5 BR5 NOTE F DL DL D Connectors (By letter)


(67) SENSOR GP - PRESSURE (71) VALVE GP - CHECK
(87) VALVE GP - (VARIABLE QC-P
Callout Number Component

QC-T (HYDRAULIC PUMP 2 OUTLET) (QUICK COUPLER) (Machine Location from (52) VALVE GP - CONTROL Name

BL5 BR5 RELIEF VALVE 2 SOL) Component LocationsTable)


138-1234
P2
Part Number

297-0265 NOTE K 123-4750 123-4750


(68) VALVE AS - BALL
(MANUAL RELIEF)
(79) VALVE GP - MAIN CONTROL
442-0234
AUX QUICK COUPLER Do not operate or work on this product unless you have
read and understood the instruction and warnings in the

512-2723 RETURN AL5 AR5 BL5 BR5


relevant Operation and Maintenance Manuals and

ATTACHMENT
relevant service literature. Failure to follow the instruc-

504-1793 NOTE B NOTE F tions or heed the warnings could result in injury or
death. Proper care is your responsibility.
A A
AL5 AR5 BL5 BR5
THIS SCHEMATIC IS FOR THE 336 AND 340 EXCAVATOR HYDRAULIC SYSTEM
VOLUME 2 of 2: ATTACHMENT
MEDIA NUMBER: M0128464-02
COMBINED FUNCTION - MANUAL RELIEF ATTACHMENT COMBINED FUNCTION - ELECTRIC RELIEF ATTACHMENT SCHEMATIC PART NUMBER: 608-1285, CHANGE: 00, VERSION: HE
Components are shown installed on a fully operable machine with the key and engine off.
Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations.
Refer to the Parts Manual using a specific serial number prefix in SIS before ordering parts from this schematic.

16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
MACHINE - LEFT SIDE
VIEW ALL CALLOUTS

14

26

21

VIEW OF AREA “A”


(ROTATED FOR CLARITY)
3 27 9 24 8
5

4 28 A

11 10
MAIN CONTROL VALVE - FRONT
VIEW ALL CALLOUTS

15
AA

17
20

16
18

23
MAIN CONTROL VALVE - REAR
VIEW ALL CALLOUTS

2 25
19

22

1
PUMP GROUP - RIGHT SIDE
VIEW ALL CALLOUTS

13

DD

BB

CC
12
BOOM AND STICK STRUCTURE
VIEW ALL CALLOUTS

SP
XX
53
XX
70

51
75
59

88

73
FILTER GP - RIGHT SIDE
VIEW ALL CALLOUTS

57 MB 69 MP MA 64

58 79 55 68 XX
66
MACHINE - RIGHT
VIEW ALL CALLOUTS

86
77 63
80 54

87 65
MACHINE - TOP LEFT
VIEW ALL CALLOUTS

61 78 72 56

83
MAIN CONTROL VALVE - REAR
VIEW ALL CALLOUTS

71
67 84
85
81

82
QUICK COUPLER LINKAGE

89

You might also like