You are on page 1of 15

Make sure your Adobe Acrobat Reader is up

SCHEMATIC FEATURES AND TIPS


to date in order to access the latest features
of this schematic.

GET
Adobe Acrobat Reader

SAVE
a copy of this schematic

THE BOOKMARKS PANEL WILL ALLOW YOU TO THE FUNCTION ISOLATION TOOLS ISOLATE
QUICKLY NAVIGATE TO POINTS OF INTEREST. CIRCUITS FOR TRACING HYDRAULIC LINES

Function Isolation Tools

Grids On/Off

All Circuits Off


STANDARD VIEW
All Circuits On

021 (Orange) (Pilot Pump Output)

032 (Red) (Main Pump Output)

577 (Lt Green) (Drain/Return Line)

Machine Views

Machine View - Front

Machine View - Rear

Implement Stack 021 (Orange) (Pilot Output)


CIRCUIT ISOLATED
CLICK HERE TO VIEW THE SCHEMATIC
UTILIZE HYPERTEXT TO NAVIGATE TO COMPONENTS AND THEIR MACHINE LOCA- SYMBOLS AND DEFINITIONS PAGE
TION QUICKLY. HYPERTEXT IS INDICATED BY TEXT THAT IS BLUE AND UNDERLINED. ELECTRICAL SYMBOLS

Pressure Temperature Level


Switch Switch Switch Circuit Breaker

BASIC HYDRAULIC SYMBOLS

Fluid Pump Spring


Variability
Conditioner or Motor (Adjustable)

HOTKEYS (Keyboard Shortcuts)

FUNCTION KEYS
Zoom In “CTRL” / “+”
Zoom Out “CTRL” / “-”
Fit to Page “CTRL” / “0” (zero)
Hand Tool “SPACEBAR” (hold down)
Find “CTRL” / “F”
WHEN ONLY ONE CALLOUT IS SHOWING ON A Search “CTRL” / “SHIFT” / “F”

MACHINE VIEW, CLICKING ON THIS BUTTON WILL


VIEW ALL CALLOUTS MAKE ALL OF THE CALLOUTS VISIBLE. THIS
Due to different monitor sizes and PDF reader
preferences there may be some variance in linked
BUTTON IS TYPICALLY LOCATED IN THE TOP RIGHT schematic locations. This document is best viewed at
CORNER OF EVERY MACHINE VIEW PAGE. a screen resolution of 1024 X 768.

© 2023 Caterpillar. All Rights Reserved. CAT, CATERPILLAR, LET’S DO THE


WORK, their respective logos, “Caterpillar Corporate Yellow”, the “Power Edge”
and Cat “Modern Hex” trade dress as well as corporate and product identity used
herein, are trademarks of Caterpillar and may not be used without permission.
Caterpillar: Non-Confidential.
SCHEMATIC SYMBOLS AND DEFINITIONS
VALVES INTERNAL PASSAGEWAYS PUMPS BASIC HYDRAULIC
ENVELOPES FLOW IN ONE
DIRECTION
FLOW ALLOWED IN
EITHER DIRECTION
PARALLEL
FLOW
CROSS
FLOW
FIXED DISPLACEMENT
COMPONENT SYMBOLS

One Position Two Position Three Position Unidirectional Bidirectional Pump


Infinite Two Three Variability
Positioning Position Position or Motor
PORTS VARIABLE DISPLACEMENT
NON- COMPENSATED

CYLINDERS Fluid Spring


(Adjustable)
Two-way Three-Way Four-Way Conditioner
Unidirectional Bidirectional
CONTROL
AB AB
Single Acting Double Acting
MOTORS Pressure
FIXED DISPLACEMENT Spring
P T P T Compensation
Normal Position Shifted Position Infinite Position

CHECK
Control
ACCUMULATORS Unidirectional Bidirectional
Valves
Line Restriction
(Variable)
VARIABLE DISPLACEMENT
Basic Spring Shuttle NON- COMPENSATED
Pilot
Symbol Loaded Line Restriction
Controlled Spring Loaded Gas Charged Restriction
(Fixed)

Unidirectional Bidirectional

PILOT CONTROL Line Restriction


MAIN AUX.

2-Section
RELEASED PRESSURE Variable and Pressure
ROTATING SHAFTS Compensated
Pump

External Return Internal Return Unidirectional Bidirectional


REMOTE SUPPLY PRESSURE Attachment Pump: Variable and
Pressure Compensated

Internal
Simplified Complete Supply Pressure Hydraulic Pneumatic
Energy Triangles

COMBINATION CONTROLS
LINES MEASUREMENT

Solenoid Solenoid Solenoid Solenoid and Servo Thermal Detent Crossing Joining
or Manual and Pilot Pilot or Manual Pressure Temperature Flow

MANUAL CONTROL FLUID STORAGE RESERVOIRS

Push-pull Lever Manual Shutoff General Manual Push Button Pedal Spring Vented Pressurized Return Above Fluid Level Return Below Fluid Level

HYDRAULIC SYMBOLS - ELECTRICAL ELECTRICAL SYMBOLS


G
M T

Pressure Temperature Level Flow


Transducer Transducer Generator Electric Pressure Pressure Switch Temperature Electrical
Switch Switch Switch Switch Circuit Breaker
(Fluid) (Gas / Air) Motor Switch (Adjustable) Switch Wire

BASIC ELECTRICAL COMPONENT SYMBOLS HARNESS AND WIRE SYMBOLS


Wire, Cable, or Harness Assembly Identification:
Fuse: A component in an electrical circuit that will open the circuit if too much current flows through it. Includes Harness Identification Letters and Harness
Connector Serialization Codes (see sample).
Switch (Normally Open): A switch that will close at a specified point (temp, press, etc.). The circle indicates
that the component has screw terminals and a wire can be disconnected from it.
AG-C4 L-C12
Switch (Normally Closed): A switch that will open at a specified point (temp, press, etc.). 111-7898 3E-5179
No circle indicates that the wire cannot be disconnected from the component. Part Number: for 1
Connector Plug
Ground (Wired): This indicates that the component is connected to a grounded wire. 2
The grounded wire is fastened to the machine.
Plug Receptacle
Pin or Socket Number
Ground (Case): This indicates that the component does not have a wire connected to ground.
It is grounded by being fastened to the machine. Harness Identification Letter(s): (A, B, C, AA, AB, AC, ...)
Harness Connector Serialization Code: The "C" stands for
"Connector" and the number indicates which connector in the
Reed Switch: A switch whose contacts are controlled by a magnet. A magnet closes the contacts of
harness (C1, C2, C3, ...)
a normally open reed switch; it opens the contacts of a normally closed reed switch.
L-C12
3E-5179
Sender: A component that is used with a temperature or pressure gauge.
The sender measures the temperature or pressure. 5A
T Its resistance changes to give an indication to the gauge of the temperature or pressure. Component
Fuse (5 Amps) 9X-1123 Part Number
Relay (Magnetic Switch): A relay is an electrical component that is activated by electricity. 325-AG135 PK-14
It has a coil that makes an electromagnet when current flows through it. Harness identification code:
This example indicates wire group 325, Wire Gauge*
The electromagnet can open or close the switch part of the relay. wire 135 in harness "AG". Wire Color
*Wire gauge is shown in AWG (American Wire Gauge)
Solenoid: A solenoid is an electrical component that is activated by electricity. but could also be shown in metric denoted with mm
It has a coil that makes an electromagnet when current flows through it.
The electromagnet can open or close a valve or move a piece of metal that can do work. 1 Deutsch connector: Typical representation
of a Deutsch connector. The plug contains all
2 sockets and the receptacle contains all pins.
Magnetic Latch Solenoid: An electrical component that is activated by electricity and held latched by a
permanent magnet. It has two coils (latch and unlatch) that make electromagnet 1 Sure-Seal connector: Typical representation
when current flows through them. It also has an internal switch that places of a Sure-Seal connector. The plug and receptacle
2 contain both pins and sockets.
the latch coil circuit open at the time the coil latches.

© 2023 Caterpillar. All Rights Reserved. CAT, CATERPILLAR, LET’S DO THE


WORK, their respective logos, “Caterpillar Corporate Yellow”, the “Power Edge”
and Cat “Modern Hex” trade dress as well as corporate and product identity used
herein, are trademarks of Caterpillar and may not be used without permission.
Caterpillar: Non-Confidential.
M0133879-02
June 2023

350 and 350 MHPU Excavator


Hydraulic System
WDP1-UP
HDJ1-UP
XCZ1-UP
YDW1-UP
KTD1-UP
KMF1-UP
YHG1-UP

Volume 1 of 2: Main Schematic


Volume 2 of 2: Attachment Schematic

PUBLICATIONS.CAT.COM
© 2023 Caterpillar. All Rights Reserved. CAT, CATERPILLAR, LET’S DO THE WORK, their respective logos, “Caterpillar Corporate Yellow”, the “Power Edge”
and Cat “Modern Hex” trade dress as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.
Caterpillar: Non-Confidential
COMPONENT LOCATION
VOLUME 1 - MAIN SCHEMATIC
Schematic Machine
Description
Location Location
Accumulator Gp - Hydraulic Charged D-14 1
Cylinder Gp - Boom (Left) J-9 2
Cylinder Gp - Boom (Right) J-8 3
Cylinder Gp - Bucket J-12 4
Cylinder Gp - Stick J-11 5
Filter Gp - Oil (Hydraulic Return) A-11 6
Filter Gp - Oil (Pump) A-9 7
Filter Gp - Oil (Travel Motor) B-9 8
Motor Gp - Piston (Fan, Suction) B-5 9
Motor Gp - Swing J-1 10
Motor Gp - Travel (Left) J-4 11
Motor Gp - Travel (Right) J-2 12
Pump Gp - Main Hydraulic C-6 13
Pump Gp - Piston (Fan) C-5 14
Sensor Gp - Pressure (Boom Cylinder Head End) I-7 15
Sensor Gp - Pressure (Boom Cylinder Rod End) I-7 16
Sensor Gp - Pressure (Bucket Cylinder Head End) I-10 17
Sensor Gp - Pressure (Bucket Cylinder Rod End) I-9 18
Sensor Gp - Pressure (Hydraulic Pump #1 Outlet) C-7 19
Sensor Gp - Pressure (Hydraulic Pump #2 Outlet) C-9 20
Sensor Gp - Pressure (Stick Cylinder Head End) C-10 21
Sensor Gp - Pressure (Stick Cylinder Rod End) C-12 22
Sensor Gp - Pressure (Swing Motor (Left)) H-1 23
Sensor Gp - Pressure (Swing Motor (Right)) H-2 24
Swivel Gp H-3 25
Valve Gp - Auxiliary H-13 26
Valve Gp - Check (Hydraulic Return) F-4 27
Valve Gp - Main Control D-9 28
Valve Gp - Travel Counterbalance (Left) H-6 29
Valve Gp - Travel Counterbalance (Right) H-3 30
COMPONENT LOCATION
VOLUME 2 - ATTACHMENT SCHEMATIC
Schematic Machine
Description
Location Location
Accumulator Gp - Charged (Combined Function - Manual Relief with Hammer Return Filter) F-14 51
Accumulator Gp - Hydraulic Charged (One Way/One Pump with Hammer Return Filter Attachment) I-12 52
Cylinder Gp - Boom (Left) (Boom Lowering Control Valve) G-8
53
Cylinder Gp - Boom (Left) (Smart Boom) D-15
Cylinder Gp - Boom (Right) (Boom Lowering Control Valve) G-7
54
Cylinder Gp - Boom (Right) (Smart Boom) D-14
Cylinder Gp - Stick G-4 55
Filter Gp - Oil Hammer, Retrun (Combined Function - Manual Relief with Hammer Return Filter) E-14
56
Filter Gp - Oil Hammer, Retrun (One Way/One Pump with Hammer Return Filter Attachment) I-12
Motor Gp - Piston E-12 57
Pump Gp - Gear C-10 58
Sensor Gp - Pressure (Boom Cylinder Head End) F-7 59
Sensor Gp - Pressure (Squeeze Head End ) (Combined Function - Electric Relief) H-8
Sensor Gp - Pressure (Squeeze Head End ) (Combined Function - Manual Relief with Hammer Return Filter) F-16 60
Sensor Gp - Pressure (Squeeze Head End ) (Combined Function - Manual Relief) I-4
Sensor Gp - Pressure (Squeeze Rod End ) (Combined Function - Electric Relief) H-7
Sensor Gp - Pressure (Squeeze Rod End ) (Combined Function - Manual Relief with Hammer Return Filter) F-16 61
Sensor Gp - Pressure (Squeeze Rod End ) (Combined Function - Manual Relief) I-4
Valve As - Check (Quick Coupler) C-7 62
Valve Gp - Check and Relief (LH) (Boom Load Control) G-8 63
Valve Gp - Check and Relief (RH) (Boom Load Control) G-6 64
Valve Gp - Check and Relief (Stick Load Control) F-3 65
Valve Gp - Control (Medium Circuit) D-11 66
Valve Gp - Manual Auxiliary, Shutoff (Combined Function - Manual Relief with Hammer Return Filter) E-15
67
Valve Gp - Manual Auxiliary, Shutoff (Combined Function - Manual Relief) I-4
Valve Gp - Solenoid (Attachment Valve #1 Retract And Extend) B-12 68
Valve Gp - Solenoid (Boom Up Ele Check (Ec2)) C-16 69
Valve Gp - Solenoid (Quick Coupler) B-5 70
Valve Gp - Solenoid (Swing Drive) I-2 71
Valve Gp - Solenoid and Relief (Variable Relief Valve #1 Pressure) I-8 72
Valve Gp - Solenoid and Relief (Variable Relief Valve #2 Pressure) I-7 73
TAP LOCATION
VOLUME 1 - MAIN SCHEMATIC

Tap Schematic
Description
Number Location
AA Pressure Sensor Port Pump 1 C-8
BB Pressure Sensor Port Pump 2 C-8
CC Gauge Port For Drain A-7
DD Case Drain Pressure Port A-6
SOS Sampling Port C-7
TAP LOCATION
VOLUME 2 - ATTACHMENT SCHEMATIC

Tap Schematic
Description
Number Location
A1 Stick Lowering Control Pressure F-3
A2 Attachment Valve #1 Extend Pressure D-13
A3 Attachment Valve #1 Retract Pressure D-11
A4 Medium Circuit Pressure Port B-11
A5 Quick Coupler Pressure Port C-7
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
(11) MOTOR GP - TRAVEL (LEFT) (12) MOTOR GP - TRAVEL (RIGHT)
511-0317 511-0317
TRAVEL MOTOR (LEFT) TRAVEL MOTOR (RIGHT) (10) MOTOR GP - SWING
(4) CYLINDER GP - BUCKET (5) CYLINDER GP - STICK (2) CYLINDER GP - BOOM (LEFT) (3) CYLINDER GP - BOOM (RIGHT) 586-1334
592-6264 592-6195 592-6302 592-6302 Dr Dr
Dr Dr
SWING MOTOR
M0133879-02 VOL 1 of 2

J J
PG
Pbr Pbr
Dr
(Dimensions: 56 inches x 35 inches)

DB
BLOCK PRV-T

Dr5 MU
M
Pi Pi
Drm2 Dra
A3 B3 C3 D3
Am Bm L Br Br L Bm Am
B2 A2

I I
PA PB
A2 (15) SENSOR GP- PRESSURE
(18) SENSOR GP- PRESSURE BOOM CYLINDER HEAD END MA MB MB MA
BUCKET CYLINDER ROD END 338-6971
338-6971

Dr1 (17) SENSOR GP- PRESSURE A3 (16) SENSOR GP- PRESSURE A B


BUCKET CYLINDER HEAD END BOOM CYLINDER ROD END
338-6971 B3 338-6971 C2 D2
42 Page,

A(LOWER) B(UPPER) B(LOWER) A(UPPER)


(29) VALVE GP - TRAVEL
B2 B1 COUNTERBALANCE (LEFT) d P
CV-2 266-7843 A C (23) SENSOR GP - PRESSURE
BDRV A1 SWING MOTOR (LEFT)
B D 338-6971
(26) VALVE GP - AUXILIARY (30) VALVE GP - TRAVEL
527-7759 (BKWD) D1 A1 (FWD) COUNTERBALANCE (RIGHT) (24) SENSOR GP - PRESSURE
H Dr5 11 HL B' D' H
COMBINED FUNCTION - ELECTRIC RELIEF & 45 5 6 26 27 23 22 19 18 13 12 266-7843 SWING MOTOR (RIGHT)
(FWD) C1 B1 (BKWD)
COMBINED FUNCTION - MANUAL RELIEF A' C' 338-6971
SECTION FOR ATCH d' P' (25) SWIVEL GP

Pe3
Pe2 619-5240

AtL

BtL
Bo2 Ao2 Dr1 Ba2 Dr5 Pna2 Bc Ac PbL Ab Bb PTa Pz

Pe1 2 SPEED SWG


DRAIN
TRAVEL PRKG BK
FILTER
CONTROL CONTROL

AUXILIARY(1)
T
PRV-T
G pp1
G

P1
P1

STRAIGHT TRAVEL
BOOM 1
BUCKET

TRAVEL(R)
STICK 2
(27) VALVE GP - CHECK
(HYDRAULIC RETURN)
521-3213

CV-T
F R3 A C F
B

46

FAN-T
PP
Drm1

P2
Un1

BOOM 2

TRAVEL(L)
SWING
IDENT ELEC DEVICE NAME

AUXILIARY(2)
STICK 1
46 AUXILIARY(1) RETRACT SOLENOID
E E
Un2 P2 45 AUXILIARY(1) EXTEND SOLENOID
39 FAN PUMP SOLENOID
8 29 STICK1 CYLINDER RETRACT SOLENOID

2 SPEED A1
28 STICK1 CYLINDER EXTEND SOLENOID
27 STICK2 CYLINDER RETRACT SOLENOID
TRAVEL 26 STICK2 CYLINDER EXTEND SOLENOID
CONTROL 25 AUXILIARY(2) RETRACT SOLENOID
24 AUXILIARY(2) EXTEND SOLENOID
A2 Rs2 23 BUCKET CYLINDER RETRACT SOLENOID
HL 22 BUCKET CYLINDER EXTEND SOLENOID
Rs1 21 BOOM2 CYLINDER RETRACT SOLENOID
10 20 BOOM2 CYLINDER EXTEND SOLENOID
Acc 19 BOOM1 CYLINDER RETRACT SOLENOID
18 BOOM1 CYLINDER EXTEND SOLENOID
17 SWING RIGHT SOLENOID
Psv R1 R2 Dra PaL Aa Ba1 Bo Ao Dr2 Ab2 16 SWING LEFT SOLENOID

Bs
As

Btr
Atr
15 LEFT TRAVEL BACKWARD SOLENOID
D D
(1) ACCUMULATOR GP 14 LEFT TRAVEL FORWARD SOLENOID
HYDRAULIC CHARGED 13 RIGHT TRAVEL BACKWARD SOLENOID
245-2975
9
Dra 28 29 (28) VALVE GP - MAIN CONTROL 24 25 21 XBb2 20 17 16 15 14
12
11
RIGHT TRAVEL FORWARD SOLENOID
STRAIGHT TRAVEL SOLENOID
A3 MU 628-4024 (STD) 10 HYDRAULIC LOCK SOLENOID
SWG XBa1
628-4025 (TOOL CONTROL SYSTEM) D1 9 SWING BRAKE SOLENOID

PRKG BK Pa2 Dr2 D2 C1


8 TRAVEL SPEED SOLENOID
7 STICK 2 CUT SOLENOID
CONTROL
7 BDRV 6 BYPASS CUT 2 SOLENOID
A4 5 BYPASS CUT 1 SOLENOID
2 MAIN HYDRAULIC PUMP #2 SOLENOID
1 MAIN HYDRAULIC PUMP #1 SOLENOID
CV-2 C3
Pa1 Drm2 C2 L1

(22) SENSOR GP - PRESSURE (19) SENSOR GP - PRESSURE FAN-Dr


D3 P2 P1 (HYDRAULIC PUMP #1 OUTLET)
C STICK CYLINDER ROD END (20) SENSOR GP - PRESSURE L C
(21) SENSOR GP - PRESSURE 338-6971
(HYDRAULIC PUMP #2 OUTLET)
Drm2
338-6971
STICK CYLINDER HEAD END
338-6971 BB AA HYDRAULIC CIRCUIT COLOR DESCRIPTIONS
338-6971 (13) PUMP GP - MAIN HYDRAULIC (9) MOTOR GP - PISTON PILOT CONTROL CIRCUIT
(FAN, SUCTION)
SOS
MAIN PUMP 2 OUTPUT
Psv 627-1301 HEAVY LIFT CONTROL CIRCUIT
505-5180 TRAVEL LEFT CONTROL CIRCUIT
4 3 FAN PUMP OUTPUT
a1 A1 ph1 ph2 A2 a2 SUPPLY LINE
B A TRAVEL RIGHT CONTROL CIRCUIT
STICK CONTROL CIRCUIT
AUXILIARY CONTROL CIRCUIT

FAN-P FAN-T
SWING CONTROL CIRCUIT
DRAIN / RETURN LINE
2 1 39 SWING BRAKE CIRCUIT
MAIN PUMP 1 OUTPUT
TRAVEL SPEED CONTROL CIRUIT
BUCKET CONTROL CIRCUIT
FAN-P BOOM CONTROL CIRCUIT

DRAIN
FILTER a3
a4 B
B LINE PATTERNS B
Pressure Line

Pilot / Load Sensing Pressure


(8) FILTER GP - OIL (14) PUMP GP - PISTON (FAN) Drain / Return Lines
(TRAVEL MOTOR) 587-1312
FAN-Dr 592-1525 Air Line

Dr Component Group

Dr B ax S L2 L CALLOUTS
BLOCK YY Taps (Pressure, Sampling, Sensor - by letter)

CV-T DL DL D Connectors (By letter)


Dr2
CC DD
Callout Number
(Machine Location from (52) VALVE GP - CONTROL
Component
Name
Component LocationsTable)
138-1234
Dr1
Part Number

A (7) FILTER GP - OIL A


(PUMP)
592-1525 THIS SCHEMATIC IS FOR THE 350 AND 350 MHPU EXCAVATOR HYDRAULIC SYSTEM
Do not operate or work on this product unless you have VOLUME 1 of 2: MAIN SCHEMATIC
read and understood the instruction and warnings in the
relevant Operation and Maintenance Manuals and MEDIA NUMBER: M0133879-02
relevant service literature. Failure to follow the instruc-
(6) FILTER GP- OIL tions or heed the warnings could result in injury or SCHEMATIC PART NUMBER: 612-8584, CHANGE: 01, VERSION: HE
death. Proper care is your responsibility. Components are shown installed on a fully operable machine with the key and engine off.
HYDRAULIC RETURN
Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations.
591-8630 Refer to the Parts Manual using a specific serial number prefix in SIS before ordering parts from this schematic.

16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

C
MAIN CONTROL VALVE CV-T
M0133879-02 VOL 2 of 2

B MAIN CONTROL VALVE CV-T


J CV-T A C J
MAIN CONTROL VALVE
A C B
Bo2 Ao2 Bo Ao
B DB
(Dimensions: 56 inches x 35 inches)

Bo2 Ao2 Bo Ao SWING MOTOR


Ao
FAN-T A B
FAN-T FAN-T
(60) SENSOR GP - PRESS Dr
SQUEEZE HEAD END
338-6971 56
(72) VALVE GP - SOLENOID SINGLE SINGLE
AND RELIEF DRAIN
CV-T (VARIABLE RELIEF VALVE #1 DOUBLE DOUBLE (61) SENSOR GP - PRESS FILTER
MAIN CONTROL VALVE (52) ACCUMULATOR GP
A C HYDRAULIC CHARGED PRESSURE)
(73) VALVE GP -
SQUEEZE ROD END
I 566-7394 338-6971 C2 D2 I
B 615-5195 P1 SOLENOID AND RELIEF
(VARIABLE RELIEF A
B (71) VALVE GP - SOLENOID
Ao G VALVE #2 PRESSURE)
41 42 570-4550 (SWING DRIVE)
612-9707
FAN-T
(56) FILTER GP - OIL R P1
SINGLE HAMMER, RETRUN (67) VALVE GP - MANUAL
555-6291 AUXILIARY, SHUTOFF
SINGLE DOUBLE DOUBLE 389-2407
SINGLE
P2
42 Page,

SINGLE SINGLE
SINGLE
R

P2
FINE SWING ATTACHMENT
H H

(61) SENSOR GP - PRESS


SQUEEZE ROD END
(60) SENSOR GP - PRESS 338-6971
SQUEEZE HEAD END
338-6971

ONE WAY/ONE PUMP WITH HAMMER


ONE WAY/ONE PUMP ATTACHMENT COMBINED FUNCTION - ELECTRIC RELIEF COMBINED FUNCTION - MANUAL RELIEF
RETURN FILTER ATTACHMENT

(53) CYLINDER GP - BOOM (LEFT) (54) CYLINDER GP - BOOM (RIGHT)


G IDENT ELEC DEVICE NAME G
592-6302 592-6302 57 FAN MOTOR SOLENOID
56 FINE SWING SOLENOID
(63) VALVE GP - CHECK 52 BOOM UP ELE CHECK SOL (EC2)
(55) CYLINDER GP - STICK
AND RELIEF (LH) (64) VALVE GP - CHECK 50 QUICK COUPLER SOLENOID #2
(BOOM LOAD CONTROL) AND RELIEF (RH) 592-6195 49 QUICK COUPLER SOLENOID #1
577-2154 (BOOM LOAD CONTROL) MAIN CONTROL VALVE 48
ATTACHMENT VALVE #1 RETRACT
MAIN CONTROL VALVE CV-T MAIN CONTROL VALVE CV-T 577-2154
PRESSURE SOLENOID
A C A C 47
ATTACHMENT VALVE #1 EXTEND
PRESSURE SOLENOID
B B VARIABLE RELIEF VALVE #2
MAIN CONTROL VALVE 42
PRESSURE SOLENOID
PaL XBa1 VARIABLE RELIEF VALVE #1
Bo2 Ao2 Bo Ao B B (65) VALVE GP - CHECK AND RELIEF 41
PRESSURE SOLENOID
Pi Pi (STICK LOAD CONTROL)
B2 577-5912
FAN-T FAN-T
XBb2
(59) SENSOR GP - PRESSURE
F BLCV-Pi BOOM CYLINDER F
SLCV-Pi C3
HEAD END
338-6971 B
Pi

-
(60) SENSOR GP - PRESS FAN-Dr BDRV
SQUEEZE HEAD END (51) ACCUMULATOR GP L

+
338-6971 CHARGED

VG max-
367-8681

VG max+
3 X2
(61) SENSOR GP - PRESS 2 X2 A1
SQUEEZE ROD END 1 SLCV-Dr
338-6971 (56) FILTER GP - OIL X1 A Dr X1 A Dr
HAMMER, RETRUN
555-6291 57
B A BLCV-Dr

E A B E
A2 TANK A Dr
(67) VALVE GP - MANUAL
AUXILIARY, SHUTOFF FAN-T FAN-P
DOUBLE DOUBLE 389-2407 D3 SLCV-Dr SLCV-Pi
BLCV-Dr BLCV-Pi
SINGLE SINGLE TANK
(57) MOTOR GP - PISTON
598-7826

COMBINED FUNCTION - MANUAL RELIEF


WITH HAMMER RETURN FILTER ATTACHMENT REVERSE FAN ATTACHMENT
D BOOM LOWERING CONTROL VALVE ATTACHMENT STICK LOWERING CONTROL VALVE ATTACHMENT D

(54) CYLINDER GP - BOOM


(RIGHT)
T2 (66) VALVE GP - CONTROL
(53) CYLINDER GP - BOOM (LEFT)
(MEDIUM CIRCUIT)
592-6302 592-6302 A2 310-0165
SB-1 A3
B A
<RET> (62) VALVE AS - CHECK
52 <EXT> (QUICK COUPLER)
Pa1 Pb1
A 123-4750

MAIN PUMP
Dr
<RET> B1
A5
B (58) PUMP GP -GEAR
C Dr6 565-0290 HYDRAULIC CIRCUIT COLOR DESCRIPTIONS C
SOL1-T PILOT CONTROL CIRCUIT

(69) VALVE GP - SOLENOID <EXT> A1 ph2 49 50 FAN PUMP OUTPUT


MEDIUM PRESSURE CONTROL CIRCUIT

(BOOM UP ELE CHECK (EC2)) SUPPLY LINE


QUICK COUPLER CIRCUIT
297-0371 A S1 S2 STICK CONTROL CIRCUIT
MPV-P AUXILIARY CONTROL CIRCUIT
SWING CONTROL CIRCUIT
B2 PLS P MAIN PUMP P T DRAIN / RETURN LINE

MPV-P MAIN PUMP 1 OUTPUT


BOOM CONTROL CIRCUIT

QC-T
T1 PPS
M MPV-T A4 TANK S
(70) VALVE GP - SOLENOID
SWING MOTOR (QUICK COUPLER)
514-7723 FOR UQC (CW)
(68) VALVE GP - SOLENOID 549-7972 FOR HQC (CPG)
Pa1 Pb1 (ATTACHMENT VALVE #1
B RETRACT AND EXTEND) B
259-7430
SB-1 QC-T
LINE PATTERNS

MU A2 B2 A1 B1 C Pressure Line
MAIN CONTROL VALVE CV-T Pilot / Load Sensing Pressure
<EXT> <RET>
Drain / Return Lines
47 48 B
C Air Line
MAIN CONTROL VALVE CV-T
Component Group

B CALLOUTS
Dr6 YY Taps (Pressure, Sampling, Sensor - by letter)
Dr Pa2 DL DL D Connectors (By letter)
BLOCK
PRV-T T P Callout Number
(52) VALVE GP - CONTROL
Component

SOL1-P (Machine Location from Name

Dr5
Component LocationsTable)
138-1234 Part Number

A A
Drm2 Dra MPV-T FAN-T
SOL1-T SOL1-P
THIS SCHEMATIC IS FOR THE 350 AND 350 MHPU EXCAVATOR HYDRAULIC SYSTEM
Do not operate or work on this product unless you have
read and understood the instruction and warnings in the
VOLUME 2 of 2: ATTACHMENT SCHEMATIC

SMART BOOM ATTACHMENT MEDIA NUMBER: M0133879-02


relevant Operation and Maintenance Manuals and
relevant service literature. Failure to follow the instruc-

MEDIUM CIRCUIT ATTACHMENT QUICK COUPLER ATTACHMENT SCHEMATIC PART NUMBER: 612-8584, CHANGE: 01, VERSION: HE
tions or heed the warnings could result in injury or
death. Proper care is your responsibility. Components are shown installed on a fully operable machine with the key and engine off.
Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations.
Refer to the Parts Manual using a specific serial number prefix in SIS before ordering parts from this schematic.

16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
CHASSIS - FRONT VIEW
VIEW ALL CALLOUTS
9

28
22

24
18

23

21
26

17

10 15 16 25
MACHINE - RIGHT SIDE VIEW
VIEW ALL CALLOUTS

5
2

11

29

12 30
PUMP COMPARTMENT
VIEW ALL CALLOUTS
7
6
14 19 20 8

DD

13

27
SOS CC AA BB
CHASSIS - FRONT VIEW
VIEW ALL CALLOUTS

73 71 72
A3

69 59
CHASSIS - RIGHT SIDE VIEW
VIEW ALL CALLOUTS

51 60

A2
A4
57
66 52

56

58

A5
62 68 70 61 67
MACHINE - RIGHT SIDE VIEW
VIEW ALL CALLOUTS

63 53 55 A1

65

54

64

You might also like