EasyFix4 v. 4.9.
0 - Concrete 1fc181061
Project: Date: 2023-05-11 Page: 1/6
Subject: Organization:
Address: Address:
Calculations made by: Contact:
Checked by: ................................................................. 2023-05-11
Notes
Input data
Anchor type and size R-KEXII+rebar 20 (fyk ≥500MPa)
Premium pure epoxy resin for use with reinforcement bars
(fyk ≥500MPa)
Nominal depth (hnom) 150 mm (hef = 150 mm)
Base material Cracked concrete (C40/50) Temp. short/long None
Reinforcement Spacing ≥150 mm or spacing ≥100 mm with ≤Ø10
A concentrated reinforcement in both directions is present in the region
of the anchorage, which limits the crack width to wk~0.3mm.
Longitudinal edge reinf. Without edge reinforcement or stirrups
Installation Hammer drilling, Installation conditions: Dry concrete
Lever arm None
Steel profile None
Proof REDM + EOTA TR029
ETA-21/0244 v.30/12/2021
Working life of 50 years
Design loads
N -300 kN
Nsus 0 kN
Mx 0 kNm
Mx,sus 0 kNm
My 0 kNm
My,sus 0 kNm
Vx 1 kN
Vy 0 kN
Ms 0 kNm
sus - Sustained loads
National regulations, environmental and application conditions must be considered when designing the anchorage.
EasyFix4 v. 4.9.0 - Concrete 1fc181061
Project: Date: 2023-05-11 Page: 2/6
Subject: Organization:
Address: Address:
Calculations made by: Contact:
Resulting anchor forces
Anchor N V Vx Vy
1 0 kN 139.5 N 139.5 N 0 kN
2 0 kN 144.9 N 144.9 N 0 kN
3 0 kN 159.7 N 159.7 N 0 kN
4 0 kN 172.1 N 172.1 N 0 kN
5 0 kN 184.6 N 184.6 N 0 kN
6 0 kN 199.2 N 199.2 N 0 kN
Max. concrete compressive stress: 750 kPa
N - Tension force
V - Shear force
Vx - Shear force x
Vy - Shear force y
Shear load (REDM + EOTA TR029, Section 5.2.3)
Steel failure without lever arm
βV1 = 0.4%
calculated for anchor: 6
86.4 kN 1.5 57.6 kN 199 N
Steel failure with lever arm βV2 = N/A
National regulations, environmental and application conditions must be considered when designing the anchorage.
EasyFix4 v. 4.9.0 - Concrete 1fc181061
Project: Date: 2023-05-11 Page: 3/6
Subject: Organization:
Address: Address:
Calculations made by: Contact:
Concrete pry-out failure βV3 = 0.9%
37.18 kN 5 MPa 12 MPa 1.0 5 MPa 20 mm 118 mm 126025 mm²
422500 mm² 178 mm 355 mm 125 mm 0.911 1.0 0 mm 1.0
64 mm 0.734 0.734 2.0 1.834 1.084 180.86 kN 1.5
120.57 kN 1000 N
Concrete edge failure βV4 = 1.6%
33.01 kN 1.7 20 mm 0.11 0.069 150 mm 50 MPa 70313 mm²
316875 mm² 125 mm 0.9 1.0 1.0 64 mm 0.745 0.745
1.0 99.75 kN 1.5 66.5 kN 1000 N
National regulations, environmental and application conditions must be considered when designing the anchorage.
EasyFix4 v. 4.9.0 - Concrete 1fc181061
Project: Date: 2023-05-11 Page: 4/6
Subject: Organization:
Address: Address:
Calculations made by: Contact:
Utilisation
Tension Shear Combined
βN βV α βNα + βVα
N/A 1.6% N/A N/A
correct connection
Hints for the calculations and the program
- According to the current guidelines for the design of anchorages, the calculations in EasyFix4 base on the assumption
that the base plate is rigid, which means that redistribution of loads on the anchors due to elastic deformation of the base
plate is not taken into account. In the software, the recommended thickness of the base plate can be determined, however
the correctness of the installation of the rigid base plate must be checked and confirmed separately.
- The size of the holes in the base plate must not be larger than it is allowed in the table with installation parameters.
Otherwise, all gaps in the holes between the anchors and the fixed element must be filled, e.g. by filling the gaps with
resin of adequate compressive strength.
- Preparation of holes and installation of fasteners must be performed in accordance with the installation instruction,
taking into account the entered input data.
- The REDM calculation method assumes that the shear force is distributed to all anchors. For this purpose, please
complete all gaps in the holes between the anchors and the fixed element, e.g. by filling the gaps with resin of suitable
compressive strength.
- The information and data contained in EasyFix4 apply only to Rawlplug products. The results of the calculations carried
out with the use of the Software are based on data entered by the User, who is exclusively responsible for the correctness
of the input data and any errors. In addition, the User is exclusively responsible for the verification and recognition of the
calculation results by a competent person, in particular with regard to compliance with applicable standards and
regulations.
Installation data for R-KEXII+rebar 20 (fyk ≥500MPa)
Diameter Ø 20 mm
Hole diameter in substrate d0 26 mm
Min. hole depth in substrate h0 155 mm
Nominal depth hnom 150 mm
Calculated min. substrate thickness hmin 540 mm
Fixture thickness tfix 10 mm
Amount of resin per one mount (normal loss) 46 ml
Fill in the gaps between the anchors and the fixture element, for example, using resin with adequate compressive
strength.
National regulations, environmental and application conditions must be considered when designing the anchorage.
EasyFix4 v. 4.9.0 - Concrete 1fc181061
Project: Date: 2023-05-11 Page: 5/6
Subject: Organization:
Address: Address:
Calculations made by: Contact:
National regulations, environmental and application conditions must be considered when designing the anchorage.
EasyFix4 v. 4.9.0 - Concrete 1fc181061
Project: Date: 2023-05-11 Page: 6/6
Subject: Organization:
Address: Address:
Calculations made by: Contact:
Fixture shape
National regulations, environmental and application conditions must be considered when designing the anchorage.