You are on page 1of 1

Document kind Document identity Revision

Service instruction SC-I 020.10.20 B


Owner organization Document type Date of revision (yyyy-mm-dd) Status Page(s)

Motors & Generators Control points before dismantling 2013-10-18 Valid 1(1)
for induction machines
Division/Department Prepared by Approved by Security level

PG Service Bengt Stehagen PO Johansson Internal limited

Control phase
Control before dismantling

No. Component / Point Control of Document


Control point
Complete machine:
Visual inspection a Machines appearance SC-I 020.10.52
Faulty eccentric run on b Condition of shaft SC-I 020.10.66
shaft
Insulation resistance c Stator winding to earth and SC-I 020.10.54
between phases
Resistance element
Heaters

Winding resistance d Stator winding SC-I 020.10.56


Resistance element
Heaters

Short circuit test/locked e Bad connections and SC-I 020.10.70


rotor test hotspots
No load run test f Phase current SC-I 020.10.60
Bearing noise
Balance/Vibrations
SC-I 020.10.62
Shaft voltage g Shaft voltage SC-I 020.10.98
Accessories h Condition of accessories SC-I 020.10.68

2 Marking a Marking of mechanical According to


couplings position on shaft workshop standard
b End shields and documented
c Leads on works order
d Terminal box position
e Order number on tags

Rev. Date Prepared by Division/ Department Description


(yyyy-mm-dd)
A 2012-08-30 BS PG Service First version
B 2013-10-18 BS PG Service Separated control point and control of

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without
express authority is strictly forbidden.
Copyright 2011 ABB.