ORIGINAL
CE
RTIFICATE NUMBER: APL-DM-6-19-16

CALIBRATION CERTIFICATE
A. CUSTOMER INFORMATION
Company name : BUREAU VERITAS LTD
YAddress : 34378-00100
Location : ABC PLACE, NAIROBI
B. EQUIPMENT INFORMATION
Name : LEICA FLEXLINE TS06PLUS TOTAL STATION
Manufacturer : LEICA SEAL
Serial number : 202WW08562801
Model : TS06 PLUS
C. CERTIFICATE INFORMATION
Cal sticker number : APL.C1506
Cal Location : APL Lab
Cal Date : 04/06/2019

D. Calibration procedure: The Total station was calibrated as per APL Procedure
APL/TP/ODM/01 - Standard Calibration Procedure for optical distance measuring
instruments is in line with ISO17123-5 - Optics and optical instruments — Field procedures
for testing geodetic and surveying instruments.
E. Reference standard: Reference field co-ordinate system was used to calibrate the Total
Station.
F. Calibration Standard and Traceability:
Traceability certificate no.; 080154-1/17/15373
G. Environmental conditions: Calibration was carried out under controlled environmental
conditions as indicated below:
Temperature: 21.4°C ±1°C
Relative Humidity: 55.7 % ±10%

H. Results validation: This Certificate is valid until JUNE 2020

Calibration by : P. KIMANI
Signature :
Checked by : J. JUMA
Signature : Date : 05/06/2019

Authorized/Validated By : Charles O
Signatur : Date : 05/06/2019
e
FOR MANAGING DIRECTOR

Calibration certificate without signature and seal is not valid. This certificate has been issued without any alteration
and may not be reproduced other than in full except with the approval of the Managing Director, Avioteq Precision
Ltd.
This Certificate only relates to the calibration status of the item/equipment whose details appear above.
Page 2 of 2

CERTIFICATE NUMBER: APL-DM-6-19-16

I. CALIBRATION RESULTS

ANGULAR MEASUREMENTS (O) DISPLACEMENT (M)


STD UUT STD UUT
0.0 0.000 2.0 2.00
5.00 5.000 4.0 4.00
10.00 10.000 6.0 6.00
20.00 20.001 8.0 8.00
40.00 40.001 10.0 10.001
80.00 80.001 20.0 20.001
85.00 85.001 25.0 25.001

J. UNCERTAINTY STATEMENT:
The Expanded Uncertainty of the calibration results for the given range of measurement is
±0.002 m. The reported expanded uncertainty is stated as expanded uncertainty of the
measurement multiplied by a coverage factor K=2, providing a confidence level of
approximately 95%.
K. REMARKS AND OBSERVATIONS:
 The results were correct during the time of calibration, and will remain valid depending on
care and handling exercised during equipment use.
Issuance of this certificate indicates that the equipment calibrated complies with
specified requirements. When the equipment does not comply with requirement, no
certificate shall be issued instead a calibration report will be issued.
………………………………………………………. END ……………………………………………………