You are on page 1of 4

DESIGN OF ISOLATED FOOTING (BASED ON EBCS 7 AND 2)

INPUT DATA
[in kN-m units,others in their standard]
Material Quality and Workmanship

Concrete Grade C30 Steel Grade S300 Class of Works

Allowable Stress 200 Select bar diameter

Design Loads Footing with predetermined Column Dimension

Axial Load 650 value(s) of ratio X:Y side x

Moment X-X 0 ratio X:Y 1.5 side y

Moment Y-Y 55 0.21


s

OUTPUTS
[in kN-m units, unless it is indicated]

Partial safety factor and Design Constants


Concrete γC fck fcd fctd Design
1.50 24.00 13.60 1.14 eccentricities
Steel γS fyk fyd ρmin ex= 0.085
1.15 300 260.87 0.002 ey= 0.000

PROPORTIONING

FOOTING DIMENSIONS CONTACT EARTH PRESSURE DISTRIBUTION


from calculation/given (At the four corners)
side X side Y σA σB σC σD
2.43 1.62 200.00 200.00 130.82 130.82

STRUCTURAL DESIGN

EFFECTIVE DEPTH REQUIRED FOR:

(a) punching shear ,deff= 0.301


(b) wide beam shear ,deff= 0.405
Observation: the critical deff= 0.405

FOOTING THICKNESS (rounded to multipe of 50) = 500mm


Hence, modified critical deff = 0.429

MAXIMUM MOMENTS and area of reinforcement

Mmax Asreq (mm2) No. bar Asprov(mm2) spacing(c/c)


Mdy= 173.95 1589.24 11Φ14 1692.46 150
Mdx= 101.02 1735.91 12Φ14 1846.32 210

Result: provide Φ14 with spacing of 150mm(c/c) in the direction of X-axis


provide Φ14 with spacing of 210mm(c/c) in the direction of Y-axis. [Asmim is used]
I

Φ14

Column Dimensions

side x 0.3

side y 0.2

You might also like