Project: Tarea3_Simulacion_RGG
Variant: Orientacion ESTE
Tables on a building
System power: 738 Wp
Gestoso - España
Author
Project: Tarea3_Simulacion_RGG
Variant: Orientacion ESTE
PVsyst V7.2.8
VC1, Simulation date:
11/11/23 18:27
with v7.2.8
Project summary
Geographical Site Situation Project settings
Gestoso Latitude 43.35 °N Albedo 0.20
España Longitude -7.88 °W
Altitude 642 m
Time zone UTC+1
Meteo data
Gestoso
Meteonorm 8.0 (1995-2017), Sat=100% - Sintético
System summary
Grid-Connected System Tables on a building
System information
PV Array Inverters
Nb. of modules 6 units Nb. of units 1 Unit
Pnom total 738 Wp Pnom total 500 W
Pnom ratio 1.476
Results summary
Produced Energy 747.3 kWh/year Specific production 1013 kWh/kWp/year Perf. Ratio PR 79.17 %
Table of contents
Project and results summary 2
General parameters, PV Array Characteristics, System losses 3
Near shading definition - Iso-shadings diagram 4
Main results 5
Loss diagram 6
Special graphs 7
PVsyst V7.2.8
VC1, Simulation date:
11/11/23 18:27
with v7.2.8
General parameters
Grid-Connected System Tables on a building
PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane Nb. of sheds 3 units Transposition Perez
Tilt/Azimuth 14 / -90 ° Identical arrays Diffuse Perez, Meteonorm
Sizes Circumsolar separate
Sheds spacing 0.76 m
Collector width 0.66 m
Ground Cov. Ratio (GCR) 85.7 %
Top inactive band 0.01 m
Bottom inactive band 0.01 m
Shading limit angle
Limit profile angle 54.4 °
PV Array Characteristics
PV module Inverter
Manufacturer Photowatt Manufacturer Mastervolt
Model PW6-123 Compact Model Soladin 600
(Original PVsyst database) (Original PVsyst database)
Unit Nom. Power 123 Wp Unit Nom. Power 0.500 kWac
Number of PV modules 6 units Number of inverters 1 unit
Nominal (STC) 738 Wp Total power 0.50 kWac
Modules 1 String x 6 In series Operating voltage 65-130 V
At operating cond. (50°C) Pnom ratio (DC:AC) 1.48
Pmpp 661 Wp
U mpp 94 V
I mpp 7.1 A
Array losses
Thermal Loss factor DC wiring losses Module Quality Loss
Module temperature according to irradiance Global array res. 221 mΩ Loss Fraction 1.5 %
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC
Uv (wind) 0.0 W/m²K/m/s
PVsyst V7.2.8
VC1, Simulation date:
11/11/23 18:27
with v7.2.8
Iso-shadings diagram
PVsyst V7.2.8
VC1, Simulation date:
11/11/23 18:27
with v7.2.8
Main results
System Production
Produced Energy 747.3 kWh/year Specific production 1013 kWh/kWp/year
Performance Ratio PR 79.17 %
Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_Grid Energy injected into grid
T_Amb Ambient Temperature PR Performance Ratio
GlobInc Global incident in coll. plane
GlobEff Effective Global, corr. for IAM and shadings
PVsyst V7.2.8
VC1, Simulation date:
11/11/23 18:27
with v7.2.8
Loss diagram
1298 kWh/m² Global horizontal irradiation
PVsyst V7.2.8
VC1, Simulation date:
11/11/23 18:27
with v7.2.8
Special graphs
Diagrama entrada/salida diaria