PVsyst - Simulation report


Grid-Connected System

Project: Tarea3_Simulacion_RGG
Variant: Orientacion ESTE
Tables on a building
System power: 738 Wp
Gestoso - España

Author
Project: Tarea3_Simulacion_RGG
Variant: Orientacion ESTE

PVsyst V7.2.8
VC1, Simulation date:
11/11/23 18:27
with v7.2.8

Project summary
Geographical Site Situation Project settings
Gestoso Latitude 43.35 °N Albedo 0.20
España Longitude -7.88 °W
Altitude 642 m
Time zone UTC+1

Meteo data
Gestoso
Meteonorm 8.0 (1995-2017), Sat=100% - Sintético

System summary
Grid-Connected System Tables on a building

PV Field Orientation Near Shadings User's needs


Fixed plane Linear shadings Unlimited load (grid)
Tilt/Azimuth 14 / -90 °

System information
PV Array Inverters
Nb. of modules 6 units Nb. of units 1 Unit
Pnom total 738 Wp Pnom total 500 W
Pnom ratio 1.476

Results summary
Produced Energy 747.3 kWh/year Specific production 1013 kWh/kWp/year Perf. Ratio PR 79.17 %

Table of contents
Project and results summary 2
General parameters, PV Array Characteristics, System losses 3
Near shading definition - Iso-shadings diagram 4
Main results 5
Loss diagram 6
Special graphs 7

11/11/23 PVsyst Licensed to Page 2/7


Project: Tarea3_Simulacion_RGG
Variant: Orientacion ESTE

PVsyst V7.2.8
VC1, Simulation date:
11/11/23 18:27
with v7.2.8

General parameters
Grid-Connected System Tables on a building

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane Nb. of sheds 3 units Transposition Perez
Tilt/Azimuth 14 / -90 ° Identical arrays Diffuse Perez, Meteonorm
Sizes Circumsolar separate
Sheds spacing 0.76 m
Collector width 0.66 m
Ground Cov. Ratio (GCR) 85.7 %
Top inactive band 0.01 m
Bottom inactive band 0.01 m
Shading limit angle
Limit profile angle 54.4 °

Horizon Near Shadings User's needs


Free Horizon Linear shadings Unlimited load (grid)

PV Array Characteristics
PV module Inverter
Manufacturer Photowatt Manufacturer Mastervolt
Model PW6-123 Compact Model Soladin 600
(Original PVsyst database) (Original PVsyst database)
Unit Nom. Power 123 Wp Unit Nom. Power 0.500 kWac
Number of PV modules 6 units Number of inverters 1 unit
Nominal (STC) 738 Wp Total power 0.50 kWac
Modules 1 String x 6 In series Operating voltage 65-130 V
At operating cond. (50°C) Pnom ratio (DC:AC) 1.48
Pmpp 661 Wp
U mpp 94 V
I mpp 7.1 A

Total PV power Total inverter power


Nominal (STC) 1 kWp Total power 0.5 kWac
Total 6 modules Nb. of inverters 1 Unit
Module area 5.6 m² Pnom ratio 1.48

Array losses
Thermal Loss factor DC wiring losses Module Quality Loss
Module temperature according to irradiance Global array res. 221 mΩ Loss Fraction 1.5 %
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC
Uv (wind) 0.0 W/m²K/m/s

Module mismatch losses Strings Mismatch loss IAM loss factor


Loss Fraction 2.0 % at MPP Loss Fraction 0.1 % ASHRAE Param: IAM = 1 - bo(1/cosi -1)
bo Param. 0.05

11/11/23 PVsyst Licensed to Page 3/7


Project: Tarea3_Simulacion_RGG
Variant: Orientacion ESTE

PVsyst V7.2.8
VC1, Simulation date:
11/11/23 18:27
with v7.2.8

Near shadings parameter


Perspective of the PV-field and surrounding shading scene

Iso-shadings diagram

11/11/23 PVsyst Licensed to Page 4/7


Project: Tarea3_Simulacion_RGG
Variant: Orientacion ESTE

PVsyst V7.2.8
VC1, Simulation date:
11/11/23 18:27
with v7.2.8

Main results
System Production
Produced Energy 747.3 kWh/year Specific production 1013 kWh/kWp/year
Performance Ratio PR 79.17 %

Normalized productions (per installed kWp) Performance Ratio PR

Balances and main results

GlobHor DiffHor T_Amb GlobInc GlobEff EArray E_Grid PR


kWh/m² kWh/m² °C kWh/m² kWh/m² kWh kWh ratio
January 43.7 21.77 6.26 42.2 39.1 27.6 24.56 0.789
February 63.8 34.37 6.40 64.7 61.2 43.1 39.26 0.823
March 107.9 57.29 8.28 106.1 101.5 70.5 64.49 0.824
April 135.9 63.13 9.52 134.6 129.8 88.1 80.55 0.811
May 164.9 80.88 11.90 160.4 155.2 103.2 94.50 0.798
June 165.3 81.50 14.83 168.7 163.7 105.9 96.89 0.778
July 169.2 75.50 16.65 167.2 162.2 104.0 94.97 0.770
August 154.8 68.21 17.03 150.7 145.5 94.8 86.71 0.780
September 119.2 47.66 15.39 114.8 110.1 72.9 66.48 0.785
October 84.1 43.33 12.68 83.2 78.8 53.9 49.18 0.801
November 49.5 24.12 8.53 48.2 44.7 31.2 27.94 0.786
December 40.2 20.67 7.01 38.3 35.0 24.6 21.79 0.771
Year 1298.4 618.43 11.24 1279.1 1226.8 819.8 747.32 0.792

Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_Grid Energy injected into grid
T_Amb Ambient Temperature PR Performance Ratio
GlobInc Global incident in coll. plane
GlobEff Effective Global, corr. for IAM and shadings

11/11/23 PVsyst Licensed to Page 5/7


Project: Tarea3_Simulacion_RGG
Variant: Orientacion ESTE

PVsyst V7.2.8
VC1, Simulation date:
11/11/23 18:27
with v7.2.8

Loss diagram
1298 kWh/m² Global horizontal irradiation

-1.49% Global incident in coll. plane


0.00% Near Shadings: irradiance loss

-4.08% IAM factor on global

1227 kWh/m² * 6 m² coll. Effective irradiation on collectors

efficiency at STC = 13.22% PV conversion

907 kWh Array nominal energy (at STC effic.)


-1.18% PV loss due to irradiance level

-4.04% PV loss due to temperature

-1.50% Module quality loss

-2.10% Mismatch loss, modules and strings

-0.78% Ohmic wiring loss


823 kWh Array virtual energy at MPP

-8.80% Inverter Loss during operation (efficiency)

-0.47% Inverter Loss over nominal inv. power


0.00% Inverter Loss due to max. input current
0.00% Inverter Loss over nominal inv. voltage
0.00% Inverter Loss due to power threshold
0.00% Inverter Loss due to voltage threshold
747 kWh Available Energy at Inverter Output
747 kWh Energy injected into grid

11/11/23 PVsyst Licensed to Page 6/7


Project: Tarea3_Simulacion_RGG
Variant: Orientacion ESTE

PVsyst V7.2.8
VC1, Simulation date:
11/11/23 18:27
with v7.2.8

Special graphs
Diagrama entrada/salida diaria

Distribución de potencia de salida del sistema

11/11/23 PVsyst Licensed to Page 7/7