Project summary
Geographical Site Situation Project settings
SHREE CEMENT JHARKHAND Latitude 22.75 °N Albedo 0.20
India Longitude 85.86 °E
Altitude 173 m
Time zone UTC+5.5
Meteo data
SHREE CEMENT JHARKHAND
Meteonorm 8.1 (1991-2012), Sat=100% - Synthetic
System summary
Grid-Connected System Sheds on ground
System information
PV Array Inverters
Nb. of modules 7479 units Nb. of units 8 units
Pnom total 4076 kWp Pnom total 2800 kWac
Pnom ratio 1.456
Results summary
Produced Energy 5614835 kWh/year Specific production 1378 kWh/kWp/year Perf. Ratio PR 77.32 %
Table of contents
Project and results summary 2
General parameters, PV Array Characteristics, System losses 3
Near shading definition - Iso-shadings diagram 5
Main results 6
Loss diagram 7
Predef. graphs 8
P50 - P90 evaluation 9
Single-line diagram 10
30/10/23 PVsyst Licensed to Saatvik Green Energy Pvt Ltd (India) Page 2/10
Project: SHREE CEMENT JHARKHAND_4.07 MWp
Variant: SHREE CEMENT JHARKHAND_4.07 MWp
General parameters
Grid-Connected System Sheds on ground
PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane Nb. of sheds 330 units Transposition Perez
Tilt/Azimuth 23 / 0 ° Sizes Diffuse Perez, Meteonorm
Sheds spacing 5.00 m Circumsolar separate
Collector width 2.29 m
Ground Cov. Ratio (GCR) 45.8 %
Top inactive band 0.02 m
Bottom inactive band 0.02 m
Shading limit angle
Limit profile angle 17.4 °
PV Array Characteristics
PV module Inverter
Manufacturer Saatvik Green Energy Pvt. Ltd Manufacturer Sungrow
Model SGE545-144MHC_15092022 Model SG350-HX
(Custom parameters definition) (Original PVsyst database)
Unit Nom. Power 545 Wp Unit Nom. Power 350 kWac
Number of PV modules 7479 units Number of inverters 8 units
Nominal (STC) 4076 kWp Total power 2800 kWac
Modules 277 Strings x 27 In series Operating voltage 500-1450 V
At operating cond. (50°C) Pnom ratio (DC:AC) 1.46
Pmpp 3744 kWp Power sharing within this inverter
U mpp 1050 V
I mpp 3565 A
Array losses
Array Soiling Losses Thermal Loss factor DC wiring losses
Loss Fraction 3.0 % Module temperature according to irradiance Global array res. 4.8 mΩ
Uc (const) 29.0 W/m²K Loss Fraction 1.5 % at STC
Uv (wind) 0.0 W/m²K/m/s
LID - Light Induced Degradation Module Quality Loss Module mismatch losses
Loss Fraction 2.0 % Loss Fraction 2.0 % Loss Fraction 1.0 % at MPP
System losses
Unavailability of the system Auxiliaries loss
Time fraction 0.8 % Proportionnal to Power 15.0 W/kW
3.0 days, 0.0 kW from Power thresh.
3 periods
30/10/23 PVsyst Licensed to Saatvik Green Energy Pvt Ltd (India) Page 3/10
Project: SHREE CEMENT JHARKHAND_4.07 MWp
Variant: SHREE CEMENT JHARKHAND_4.07 MWp
AC wiring losses
Inv. output line up to injection point
Inverter voltage 800 Vac tri
Loss Fraction 0.00 % at STC
Inverter: SG350-HX
Wire section (8 Inv.) Alu 8 x 3 x 300 mm²
Average wires length 0m
30/10/23 PVsyst Licensed to Saatvik Green Energy Pvt Ltd (India) Page 4/10
Project: SHREE CEMENT JHARKHAND_4.07 MWp
Variant: SHREE CEMENT JHARKHAND_4.07 MWp
Iso-shadings diagram
Orientation #1
30/10/23 PVsyst Licensed to Saatvik Green Energy Pvt Ltd (India) Page 5/10
Project: SHREE CEMENT JHARKHAND_4.07 MWp
Variant: SHREE CEMENT JHARKHAND_4.07 MWp
Main results
System Production
Produced Energy 5614835 kWh/year Specific production 1378 kWh/kWp/year
Perf. Ratio PR 77.32 %
Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_Grid Energy injected into grid
T_Amb Ambient Temperature PR Performance Ratio
GlobInc Global incident in coll. plane
GlobEff Effective Global, corr. for IAM and shadings
30/10/23 PVsyst Licensed to Saatvik Green Energy Pvt Ltd (India) Page 6/10
Project: SHREE CEMENT JHARKHAND_4.07 MWp
Variant: SHREE CEMENT JHARKHAND_4.07 MWp
Loss diagram
1670 kWh/m² Global horizontal irradiation
+6.7% Global incident in coll. plane
30/10/23 PVsyst Licensed to Saatvik Green Energy Pvt Ltd (India) Page 7/10
Project: SHREE CEMENT JHARKHAND_4.07 MWp
Variant: SHREE CEMENT JHARKHAND_4.07 MWp
Predef. graphs
Daily Input/Output diagram
30/10/23 PVsyst Licensed to Saatvik Green Energy Pvt Ltd (India) Page 8/10
Project: SHREE CEMENT JHARKHAND_4.07 MWp
Variant: SHREE CEMENT JHARKHAND_4.07 MWp
Probability distribution
30/10/23 PVsyst Licensed to Saatvik Green Energy Pvt Ltd (India) Page 9/10
PVsyst V7.4.2
VC1, Simulation date:
30/10/23 16:58
with v7.4.2