You are on page 1of 8

Version 7.3.

PVsyst - Simulation report


Grid-Connected System

Project: Himachal Futuristic Communications Ltd_ Fab City Rd_Telangana


Variant: New simulation variant
No 3D scene defined, no shadings
System power: 1139 kWp
Jannaiguda - India

Author
Saatvik Green Energy Pvt Ltd (India)
Project: Himachal Futuristic Communications Ltd_ Fab City
Rd_Telangana
PVsyst V7.3.4
Variant: New simulation variant
VC0, Simulation date:
16/05/23 16:30 Saatvik Green Energy Pvt Ltd (India)
with v7.3.4

Project summary
Geographical Site Situation Project settings
Jannaiguda Latitude 17.20 °N Albedo 0.20
India Longitude 78.50 °E
Altitude 584 m
Time zone UTC+5.5

Meteo data
Jannaiguda
Meteonorm 8.1 (1996-2015), Sat=100% - Synthetic

System summary
Grid-Connected System No 3D scene defined, no shadings

PV Field Orientation Near Shadings User's needs


Fixed planes 2 orientations No Shadings Unlimited load (grid)
Tilts/azimuths 10 / 90 °
10 / -90 °

System information
PV Array Inverters
Nb. of modules 2090 units Nb. of units 7 units
Pnom total 1139 kWp Pnom total 875 kWac
Pnom ratio 1.302

Results summary
Produced Energy 1628154 kWh/year Specific production 1429 kWh/kWp/year Perf. Ratio PR 77.45 %

Table of contents
Project and results summary 2
General parameters, PV Array Characteristics, System losses 3
Main results 5
Loss diagram 6
Predef. graphs 7
P50 - P90 evaluation 8

16/05/23 PVsyst Licensed to Saatvik Green Energy Pvt Ltd (India) Page 2/8
Project: Himachal Futuristic Communications Ltd_ Fab City
Rd_Telangana
PVsyst V7.3.4
Variant: New simulation variant
VC0, Simulation date:
16/05/23 16:30 Saatvik Green Energy Pvt Ltd (India)
with v7.3.4

General parameters
Grid-Connected System No 3D scene defined, no shadings

PV Field Orientation
Orientation Sheds configuration Models used
Fixed planes 2 orientations Transposition Perez
Tilts/azimuths 10 / 90 ° Diffuse Perez, Meteonorm
10 / -90 ° Circumsolar separate

Horizon Near Shadings User's needs


Free Horizon No Shadings Unlimited load (grid)

PV Array Characteristics
PV module Inverter
Manufacturer Saatvik Green Energy (P) ltd Manufacturer Growatt New Energy
Model SGE545-144MBHC Model MAX 125KTL3-X LV
(Custom parameters definition) (Original PVsyst database)
Unit Nom. Power 545 Wp Unit Nom. Power 125 kWac
Number of PV modules 2090 units Number of inverters 7 units
Nominal (STC) 1139 kWp Total power 875 kWac
Modules 110 Strings x 19 In series Operating voltage 180-1000 V
At operating cond. (50°C) Pnom ratio (DC:AC) 1.30
Pmpp 1045 kWp Power sharing within this inverter
U mpp 719 V
I mpp 1454 A

Total PV power Total inverter power


Nominal (STC) 1139 kWp Total power 875 kWac
Total 2090 modules Number of inverters 7 units
Module area 5399 m² Pnom ratio 1.30
Cell area 4969 m²

Array losses
Array Soiling Losses Thermal Loss factor DC wiring losses
Loss Fraction 3.0 % Module temperature according to irradiance Global array res. 8.2 mΩ
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC
Uv (wind) 0.0 W/m²K/m/s

Serie Diode Loss LID - Light Induced Degradation Module Quality Loss
Voltage drop 0.7 V Loss Fraction 2.0 % Loss Fraction -0.3 %
Loss Fraction 0.1 % at STC

Module mismatch losses Strings Mismatch loss


Loss Fraction 2.0 % at MPP Loss Fraction 0.2 %

IAM loss factor


Incidence effect (IAM): User defined profile

0° 25° 45° 60° 65° 70° 75° 80° 90°


1.000 1.000 0.995 0.962 0.936 0.903 0.851 0.754 0.000

System losses

16/05/23 PVsyst Licensed to Saatvik Green Energy Pvt Ltd (India) Page 3/8
Project: Himachal Futuristic Communications Ltd_ Fab City
Rd_Telangana
PVsyst V7.3.4
Variant: New simulation variant
VC0, Simulation date:
16/05/23 16:30 Saatvik Green Energy Pvt Ltd (India)
with v7.3.4

System losses
Unavailability of the system
Time fraction 2.0 %
7.3 days,
3 periods

AC wiring losses
Inv. output line up to injection point
Inverter voltage 400 Vac tri
Loss Fraction 2.10 % at STC
Inverter: MAX 125KTL3-X LV
Wire section (7 Inv.) Alu 7 x 3 x 150 mm²
Average wires length 100 m

16/05/23 PVsyst Licensed to Saatvik Green Energy Pvt Ltd (India) Page 4/8
Project: Himachal Futuristic Communications Ltd_ Fab City
Rd_Telangana
PVsyst V7.3.4
Variant: New simulation variant
VC0, Simulation date:
16/05/23 16:30 Saatvik Green Energy Pvt Ltd (India)
with v7.3.4

Main results
System Production
Produced Energy 1628154 kWh/year Specific production 1429 kWh/kWp/year
Perf. Ratio PR 77.45 %

Normalized productions (per installed kWp) Performance Ratio PR

Balances and main results

GlobHor DiffHor T_Amb GlobInc GlobEff EArray E_Grid PR


kWh/m² kWh/m² °C kWh/m² kWh/m² kWh kWh ratio
January 150.3 48.13 23.27 149.5 141.3 140944 137558 0.808
February 156.6 55.07 26.24 155.9 148.1 144952 126277 0.711
March 194.9 69.04 29.72 193.7 184.5 176290 157009 0.712
April 192.9 72.46 31.95 191.6 182.7 172613 168198 0.771
May 193.4 87.24 33.53 192.1 183.2 173482 169165 0.773
June 151.7 89.03 29.27 150.6 143.1 140019 124062 0.723
July 128.6 77.37 27.44 127.5 120.8 119683 116801 0.804
August 138.4 82.24 26.40 137.2 130.2 129198 126066 0.807
September 136.1 74.48 26.31 135.0 128.1 126535 123461 0.803
October 140.5 72.66 26.35 139.4 132.1 130921 127751 0.805
November 136.7 54.82 24.14 135.6 128.0 127731 124639 0.807
December 138.3 54.51 22.91 137.4 129.5 130214 127167 0.812
Year 1858.5 837.05 27.30 1845.6 1751.7 1712581 1628154 0.774

Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_Grid Energy injected into grid
T_Amb Ambient Temperature PR Performance Ratio
GlobInc Global incident in coll. plane
GlobEff Effective Global, corr. for IAM and shadings

16/05/23 PVsyst Licensed to Saatvik Green Energy Pvt Ltd (India) Page 5/8
Project: Himachal Futuristic Communications Ltd_ Fab City
Rd_Telangana
PVsyst V7.3.4
Variant: New simulation variant
VC0, Simulation date:
16/05/23 16:30 Saatvik Green Energy Pvt Ltd (India)
with v7.3.4

Loss diagram
1858 kWh/m² Global horizontal irradiation

-0.69% Global incident in coll. plane


-2.15% IAM factor on global

-3.00% Soiling loss factor

1752 kWh/m² * 5399 m² coll. Effective irradiation on collectors

efficiency at STC = 21.15% PV conversion

2000668 kWh Array nominal energy (at STC effic.)


-0.03% PV loss due to irradiance level

-9.86% PV loss due to temperature

+0.25% Module quality loss

-2.00% LID - Light induced degradation

-2.15% Mismatch loss, modules and strings

-1.11% Ohmic wiring loss


-0.02% Mixed orientation mismatch loss
1713560 kWh Array virtual energy at MPP
-1.41% Inverter Loss during operation (efficiency)
-0.06% Inverter Loss over nominal inv. power
0.00% Inverter Loss due to max. input current
0.00% Inverter Loss over nominal inv. voltage
0.00% Inverter Loss due to power threshold
0.00% Inverter Loss due to voltage threshold
0.00% Night consumption
1688321 kWh Available Energy at Inverter Output

-1.02% AC ohmic loss

-2.57% System unavailability


1628154 kWh Energy injected into grid

16/05/23 PVsyst Licensed to Saatvik Green Energy Pvt Ltd (India) Page 6/8
Project: Himachal Futuristic Communications Ltd_ Fab City
Rd_Telangana
PVsyst V7.3.4
Variant: New simulation variant
VC0, Simulation date:
16/05/23 16:30 Saatvik Green Energy Pvt Ltd (India)
with v7.3.4

Predef. graphs
Daily Input/Output diagram

System Output Power Distribution

16/05/23 PVsyst Licensed to Saatvik Green Energy Pvt Ltd (India) Page 7/8
Project: Himachal Futuristic Communications Ltd_ Fab City
Rd_Telangana
PVsyst V7.3.4
Variant: New simulation variant
VC0, Simulation date:
16/05/23 16:30 Saatvik Green Energy Pvt Ltd (India)
with v7.3.4

P50 - P90 evaluation


Meteo data Simulation and parameters uncertainties
Source Meteonorm 8.1 (1996-2015), Sat=100% PV module modelling/parameters 1.0 %
Kind Monthly averages Inverter efficiency uncertainty 0.5 %
Synthetic - Multi-year average Soiling and mismatch uncertainties 1.0 %
Year-to-year variability(Variance) 5.4 % Degradation uncertainty 1.0 %
Specified Deviation
Climate change 0.0 %

Global variability (meteo + system) Annual production probability


Variability (Quadratic sum) 5.7 % Variability 93.1 MWh
P50 1628.2 MWh
P90 1508.8 MWh
P75 1565.4 MWh

Probability distribution

16/05/23 PVsyst Licensed to Saatvik Green Energy Pvt Ltd (India) Page 8/8