PVsyst - Simulation report


Grid-Connected System

Project: Ayu Maharani


Variant: Ayu Maharani
No 3D scene defined, no shadings
System power: 3270 Wp
Jl. Boulevard Grand Depok City, Grand Dahlia Cluster, Blok B - Indonesia

Author
Project: Ayu Maharani
Variant: Ayu Maharani

PVsyst V7.2.8
VC0, Simulation date:
02/03/23 14:18
with v7.2.8

Project summary
Geographical Site Situation Project settings
Latitude Blok B
Jl. Boulevard Grand Depok City, Grand Dahlia Cluster, -6.44 °S Albedo 0.20
Indonesia Longitude 106.83 °E
Altitude 85 m
Time zone UTC+7

Meteo data
Jl. Boulevard Grand Depok City, Grand Dahlia Cluster, Blok B
Meteonorm 8.0 (2010-2014), Sat=100% - Synthetic

System summary
Grid-Connected System No 3D scene defined, no shadings
Simulation for year no 25

PV Field Orientation Near Shadings User's needs


Fixed plane No Shadings Unlimited load (grid)
Tilt/Azimuth 15 / 0 °

System information
PV Array Inverters
Nb. of modules 6 units Nb. of units 1 Unit
Pnom total 3270 Wp Pnom total 3000 W
Pnom ratio 1.090

Results summary
Produced Energy 4502 kWh/year Specific production 1377 kWh/kWp/year Perf. Ratio PR 79.23 %

Table of contents
Project and results summary 2
General parameters, PV Array Characteristics, System losses 3
Main results 5
Loss diagram 6
Special graphs 7

02/03/23 PVsyst Licensed to Page 2/7


Project: Ayu Maharani
Variant: Ayu Maharani

PVsyst V7.2.8
VC0, Simulation date:
02/03/23 14:18
with v7.2.8

General parameters
Grid-Connected System No 3D scene defined, no shadings

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 15 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate

Horizon Near Shadings User's needs


Free Horizon No Shadings Unlimited load (grid)

PV Array Characteristics
PV module Inverter
Manufacturer JA Solar Manufacturer Huawei Technologies
Model JAM72S30_545_MR Model SUN2000-3KTL-L1
(Custom parameters definition) (Custom parameters definition)
Unit Nom. Power 545 Wp Unit Nom. Power 3.00 kWac
Number of PV modules 6 units Number of inverters 1 unit
Nominal (STC) 3270 Wp Total power 3.0 kWac
Modules 1 String x 6 In series Operating voltage 90-560 V
At operating cond. (50°C) Max. power (=>40°C) 3.30 kWac
Pmpp 3030 Wp Pnom ratio (DC:AC) 1.09
U mpp 228 V
I mpp 13 A

Total PV power Total inverter power


Nominal (STC) 3 kWp Total power 3 kWac
Total 6 modules Nb. of inverters 1 Unit
Module area 15.5 m² Pnom ratio 1.09

Array losses
Array Soiling Losses Thermal Loss factor DC wiring losses
Loss Fraction 3.0 % Module temperature according to irradiance Global array res. 188 mΩ
Uc (const) 20.0 W/m²K Loss Fraction 1.0 % at STC
Uv (wind) 0.0 W/m²K/m/s

Module Quality Loss Module mismatch losses Strings Mismatch loss


Loss Fraction 0.0 % Loss Fraction 2.0 % at MPP Loss Fraction 0.1 %

Module average degradation


Year no 25
Loss factor 0.02 %/year
Mismatch due to degradation
Imp RMS dispersion 0.4 %/year
Vmp RMS dispersion 0.4 %/year

IAM loss factor


Incidence effect (IAM): Fresnel smooth glass, n = 1.526

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000

02/03/23 PVsyst Licensed to Page 3/7


Project: Ayu Maharani
Variant: Ayu Maharani

PVsyst V7.2.8
VC0, Simulation date:
02/03/23 14:18
with v7.2.8

AC wiring losses
Inv. output line up to injection point
Inverter voltage 220 Vac mono
Loss Fraction 0.30 % at STC
Inverter: SUN2000-3KTL-L1
Wire section (1 Inv.) Copper 1 x 2 x 3 mm²
Wires length 3m

02/03/23 PVsyst Licensed to Page 4/7


Project: Ayu Maharani
Variant: Ayu Maharani

PVsyst V7.2.8
VC0, Simulation date:
02/03/23 14:18
with v7.2.8

Main results
System Production
Produced Energy 4502 kWh/year Specific production 1377 kWh/kWp/year
Performance Ratio PR 79.23 %

Normalized productions (per installed kWp) Performance Ratio PR

Balances and main results

GlobHor DiffHor T_Amb GlobInc GlobEff EArray E_Grid PR


kWh/m² kWh/m² °C kWh/m² kWh/m² kWh kWh ratio
January 122.0 71.48 24.61 111.8 103.9 294.9 285.6 0.781
February 137.6 80.06 24.47 130.5 122.3 347.0 337.8 0.792
March 139.9 85.30 25.05 138.5 130.2 368.3 358.4 0.791
April 144.7 77.93 25.10 150.3 141.7 399.2 389.1 0.792
May 139.7 81.08 25.58 150.6 142.0 401.8 391.7 0.795
June 138.1 69.38 24.97 152.8 144.8 408.9 398.9 0.798
July 147.8 72.11 24.63 162.3 153.9 434.3 423.8 0.799
August 155.1 80.33 25.13 165.0 156.3 440.0 429.3 0.795
September 157.1 79.75 25.05 159.3 150.4 422.2 411.9 0.791
October 167.7 98.37 25.66 161.9 152.2 429.3 418.8 0.791
November 140.4 86.62 24.92 130.1 121.5 345.5 336.2 0.790
December 136.0 86.43 24.92 124.5 115.9 329.9 320.5 0.787
Year 1725.9 968.84 25.01 1737.6 1635.1 4621.3 4501.9 0.792

Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_Grid Energy injected into grid
T_Amb Ambient Temperature PR Performance Ratio
GlobInc Global incident in coll. plane
GlobEff Effective Global, corr. for IAM and shadings

02/03/23 PVsyst Licensed to Page 5/7


Project: Ayu Maharani
Variant: Ayu Maharani

PVsyst V7.2.8
VC0, Simulation date:
02/03/23 14:18
with v7.2.8

Loss diagram
1726 kWh/m² Global horizontal irradiation
+0.7% Global incident in coll. plane

-2.99% IAM factor on global

-3.00% Soiling loss factor

1635 kWh/m² * 16 m² coll. Effective irradiation on collectors

efficiency at STC = 21.12% PV conversion

5354 kWh Array nominal energy (at STC effic.)


-0.56% Module Degradation Loss ( for year #25)
-0.92% PV loss due to irradiance level

-7.09% PV loss due to temperature

0.00% Module quality loss

-5.12% Mismatch loss, modules and strings


(including 3% for degradation dispersion

-0.62% Ohmic wiring loss


4621 kWh Array virtual energy at MPP
-2.34% Inverter Loss during operation (efficiency)
0.00% Inverter Loss over nominal inv. power
0.00% Inverter Loss due to max. input current
0.00% Inverter Loss over nominal inv. voltage
0.00% Inverter Loss due to power threshold
0.00% Inverter Loss due to voltage threshold
-0.10% Night consumption
4508 kWh Available Energy at Inverter Output

-0.14% AC ohmic loss


4502 kWh Energy injected into grid

02/03/23 PVsyst Licensed to Page 6/7


Project: Ayu Maharani
Variant: Ayu Maharani

PVsyst V7.2.8
VC0, Simulation date:
02/03/23 14:18
with v7.2.8

Special graphs
Daily Input/Output diagram

System Output Power Distribution

02/03/23 PVsyst Licensed to Page 7/7