You are on page 1of 11

1

Date: 08/01/2024

To

M/s Tuikual North Presbyterian Church


Aizawl

Dear Sir,

Sub: Order Acknowledgement for ONE (1) No “Firefox Elevators” as a brand of Firefox Elevators Pvt.Ltd.
electric traction elevator for your site at

We would like to reiterate the fact that you are dealing with the word leaders in elevators and escalator business.

We are glad to receive your valued order & wish to thank you for your acceptance of our proposal
for supply and installation of ONE (1) Number Firefox Elevator for your project.

Please find enclosed one copy of the agreement duly approved by our authorized official for your record.

Contract no.: FF/08-01-2024


Has been allocated against your order. You are requested to use this no. for future correspondence.

Besides above to streamline and provide best service please find below mentioned Escalation matrix of our
Team to whom you can contact for any communication & services.

Employee Name Designation Mobile Number Email id


Mahender Singh Operation Head 8447728220 sales@firefoxelevators.com
Shashi Chaudhary CRM 7065571919 sales@firefoxelevators.com
Roshan Nahata Director 7065575151 firefoxelevators@gmail.com
For any clarifications or additional information, please feel free to contact to undersigned. We
value your association with Firefox and assure you of our best service at all times.

Yours faithfully

Firefox Elevators Pvt. Ltd.

Assistant Manager-sales

2
To
Firefox Elevators Pvt. Ltd.

Khasra No.-903-910
Groundfloor, Rithala
Village, Delhi-110085

Subject: order for supply & installation of Firefox lift

Dear sir,

Bank name...................................... Towards the advance payment against subject orders.

1) This is to conform that we have issued the subject cheque against the neg No-…………………….
2) This is to conform that, Mr./MS/M/s ............. (cheque signature) has issued this cheque on
behalf of Mr./MS/M/s ..................................... (agreement signature).

(Signature of agreement signatory) (Signature of cheque signatory)

3
MAINTENANCE

Our quotation includes charges towards maintenance for Twelve months. The periods of this
maintenance shall commence from the date of completed installation and handing over of the
lift. The date of commencement of this service shall I remain firm irrespective of any delay in
building completion, availability of permanent power supply, inspection, taking over or
commencing use of the elevator.

Maintenance will consist of regular checkups and other necessary adjustment and lubrication
of the equipment by trained and competent personnel under our direction and supervision.
The required supplies and parts will be provided except such a part as may be necessary due
to negligence, misuse or accident not attributable to the manufacturing deficiencies of the
product. Upon your request, special inspection will be carried out should trouble develop
between regular inspection and you agree to notify us promptly of any such trouble. All work
will be performed during our regular working hours of our regular working days except for
emergency and minor adjustment callback service which will be provided during regular
working hours and also during the overtime hours. No work or service other than the
specifically mentioned is included or intended under the terms and condition of this contract.

It is agreed that you shall continue to be the exclusive owner of the equipment and
thereby the possession or control thereof.

We shall not be liable for any loss, damage, or delay due to any cause beyond our
reasonable control including but not limited to acts of government, strikes, explosion, theft,
floods, riots, civil commotion, war, malicious mischief or act of God. Under no circumstances
shall we be liable for consequential damage.

4
M/s Tuikual North Presbyterian Church Reg no.:FF/08-01-2024
Aizawl

Date:08-01-2024
Model code:01

Proposal of (1) Nos. Firefox elevators for your project

To be furnished erected in accordance with the following details:

Group 1, unit 1

Elevator No.-00100 KT0999


Number of Units 1
Civil Requirement
Clear inside Change as per site
shaft(required)
Clear inside shaft 2000mm X 2400mm (Change as per site)
(available)
Pit Depth 2000 mm
Minimum Floor to floor 2600 mm
Height
Travel Height 18 mtr
Headroom Height 4300mm
Intel Height required 2230 mm from finished floor level (2300 Height Possible
Subject to this)
Lockable storage room
(required)
Elevator Specification Machine Room Less
Number of persons 15
Rated Load 1020 Kg
Number of Stops 6
Number of Access Sides 1
Floor destinations G,1,2,3,4,5
Drive system Variable Current Voltage Frequency (VVVF)
Type of Controller Full Collective control –Simplex
Speed of travel 1 m/s
Car Size As per site availability
Door Width 1000mm
Door Height 2000 mm

5
Control Panel MONOBLOCK
Rope 8X19S FIBRE CORE SELF LUBRICATING -USHA MARTIN
Rated output motor 26 MPR

Car Design Car walls finish in Stainless Steel cabin with light fan
Car Doors SS
Cabin doors -SS Doors
Floor finish in Galaxy- Tiles

Car Opening panel


Attractive Car display and Push buttons with Music Card.
Door open/close and alarm

Car position indicator


Pre-announcing arrows for collective controls
Full segment display
Landing Doors
Fully Automatic doors
Door opening direction Center
Standard Features
Close loop control system
Self-diagnostic control
Overload detection
Automatic Evacuation to nearest floor (ARD)
Light curtain on car entrance
Auto fan off
Auto light off
Other selected features
Intercom
Out of service mode
Safety Torque Off
Fireman Control

Machine Traction Motor

6
FEATURES:

1. Direction & Position Indicator in Car


2. Emergency Alarm
3. Facia Plate
4. Fireman Switch
5. Full height infra-red safety curtains
6. Pit Ladder (if applicable)
7. Round tabular Handrail on the rear side of the car
8. Signal Fixtures
9. Emergency light with battery
10. Adjustable guide shoes
11. Micro movement LED based Buttons.
12. +10% To – 10% Volt Fluctuation withstand capacity
13. Load weighing device.
14. Over speed governor.
15. Automatic rescue device.
16. Automatic phase Reversal

We propose to furnish and erect the installation outlined in the forgoing proposal.

7
Lift solution Unit Price- Rs.15,90,000/- Plus GST
Group 1 Unit
Model No.: Standard

Total Amount: Fifteen Lakh Ninety Thousand Only. (Exclusive of Taxes)

The price/s quoted herein is /are Exclusive of all taxes (expect local body tax applicable in
DELHI state), as currently applicable, whether levied by the central government or the state
government. In the event of any amendment or variation in the rate or mythology for charging
the applicable taxes, and/or should be any new levies imposed in respect of this contract, the
entire burden of any additional levy shall be borne and payable by you demand at any time, in
addition to the price/s stated herein.

ALL RIGHTS RESERVED TO FIREFOX ELEVATORS

On behalf of Purchaser On behalf of Firefox Elevators Pvt. Ltd.

Name Signatory Name Signatory

8
WARRANTY: -

We Provide Twelve Months Warranty on our elevator (T&C apply).


The payment shall be made as mentioned below:
 25% advance at the time of confirmation of the order
 70% two weeks before dispatch of mechanical kit.
 5% on handover.

Notes:

 The above prices mentioned are exclusive of taxes; however, any statutoryvariation
shall be to your account.
 The legal possession of the lift will transfer to you only when full payment is madeas per the
above agreement
 The order once placed will not be refund in any case.
 This Offer is Valid till 30th JAN’2024.

9
DETAILS OF AFTER SALES SERVICE

DATED- 08-01-2024

Fast and prompt after sales service warranty on electrical parts on continuation of AMC (AMC charges
extra). Hassel free maintenance. Fixed maintenance cost.

CIVIL AND ELECTRICAL WORK ARE PROVIDE BY OWNER

 All civil work, 3 phase electric supply at machine room and single-phase electric supply in
elevator shaft and MCD/DDA permission and works shall be to your account.

1. 3 PHASE 4-wire cable 6Sq.mm copper/alum with 63 amp ELCB. and double earthling of 14
SWG copper wire 415VAC +OR~ 10%@50HZ+OR~3%
2. 16AMP MCCB For elevator lighting with ISI mark.
3. 16AMP MCCB for machine room & elevator shaft lighting with ISI mark.
4. One plug point and one bulb holder with switches in the elevator shaft on each floor.
5. (A) Lighting points in the M/C room with two switches.
(B) Plug point in the M/C room with one switch.
(C) Exhaust fan point with one switch.
(D) Electrical caution board two nos
6. Beam in the machine room.

On behalf of Purchaser On behalf of Firefox Elevators Pvt Ltd.

Name___________________ Name___________________________

Authorized Signatory
10