Observation: Reverse horn found not working on dumper (MP 28H 0743)
Corrective action Ensure availability of Stability drawing and third party certificates
Observation: Gas cutting set found without cylinder trolley, flash back arrestor,
regulators and without fire extinguisher
Observation: Safety guard found in damaged condition of chop saw cutting machine
Corrective action Gas cylinder shall be stored in upright position with proper securing
arrangements
LOCATION: Nandi Camp Date 18.12.2022 Status PENDING
Corrective action Proper storage and disposal of hazardous materials needs to be adopted
Corrective action Ensure joining of electrical cable with proper joining kit
Corrective action Electrical cable shall be properly routed, either underground or overhead
Observation: Single insulated cable found used for electrical connections and observed
improper jointing on cable
Corrective action Proper jointing of electrical cable to be adopted, Double insulated cable
to be ensured
Corrective action Standard electrical joints must be provided at working site for electrical
connections
LOCATION: Ch. 198+160 FLO Date 11.01.2023 Status PENDING
Corrective action Area around conveyor belt to be barricaded for restricting the movement
Observation: Limit switches, interlocking arrangements found not provided for pugmill
Corrective action Proper loading ramp with barricading and delineation to be provided
Observation: Shifting of material found without tagline and 6 nos of workmen found
without PPEs
Corrective action Ensure availability of tagline/guide rope during material shifting and
availability of job specific PPEs
LOCATION: Ch. 197+500 Date 03.02.2023 Status PENDING
Corrective action Ensure availability of valid TPI certification for all lifting tools and tackles
Observation: Improper storing of gas cylinder( Gas cylinder found kept with oil)
observed.