BSR 512:

topic 2
Dr Norehan Haji Mohd Noor
Senior Lecturer
Program of Building Surveying, UiTM Perak
4 Types @ sections:

1. Cold Water Services


2. Soil, waste & ventilation & Sanitary
Installation
1. Sanitary Appliances
2. Builder’s Work In Connection (BWIC)
Cold Water Services
1. All plumbing works – refer SMM2 Sect. Q page
94
2. Types of pipe used in Cold Water Supply
system; e.g;
Previously G.I pipe; and lately UPVC & HDPE.

3. UPVC uses;
• Class A for wiring /electrical installation
• Class B for above ground
• Class C for Below ground
• Class D for hot water installation
SEQUENCE OF TAKING OFF;
1.Location
a) Rising Main Pipe
 start from incoming METER to WATER TANK
 Pipe to Kitchen
 Pipe to garden tap

b) Down service pipe @ dropper pipe


– pipe from water tank to bathrooms

c) Branch pipe / distribution pipe


 pipe to connect all fittings, eg WC, WB, tub, shower
etc
d) Water Tank – type, size, etc
SEQUENCE OF TAKING OFF;

2. The Type of Pipe – UPVC, HDPE etc

3. Diameter of pipe – 15 mm dia, 20mm, 25mm, 32 mm, 40

4.Fixing of pipe
Laid in trenches
Chased in brick wall
Fixed in induct
Embedded in concrete
Fixed to wall
Free standing
SEQUENCE OF TAKING OFF;
5.Fittings
•bend
•Elbow
•Reducer bend or T
•Unequal junction
•Stock cock
•Stop valve
•Ball valve; etc

5.Accessories
Tank connector & all asseccories
Internal COLD WATER SERVICES
System
Service Pipe

1st floor Toile


t
Inlet Pipe Wash basin
(graviti flow)

Communication
Pipe
Ground floor
Toilet
Kitchen
meter

Main Pipe
Double Storey
Building
Internal COLD WATER SERVICES
System

Service Pipe

1st floor toilet


Sink
Inlet Pipe

Communication
Pipe Ground floor
toilet
meter kitchen

Main Pipe

Inlet / Riser Pipe to Water Tank


Tingkat atas bilik Paip agihan
air
Besen basuh
tangan

Tingkat bawah bilik


air
dapur

Paip awam

Droper Pipe / Distributor pipe from Tank


1st Floor Bathroom

WB

X = Stockcock or
Stock valve
Ground Floor
Bath room
Meter Kitchen

Public pipe

Schematic Plan 2D – Internal Cold


Water System For 2-storey House
INTERNAL Cold Water System

Storage Tank:

Standard of Capacity usually 'at least a day's use'


Function - For storage and use during disconnected /
absence of water supply.
Reduces the maximum flow rate in the public pipe.
Reduce high pressure in water flow in building pipes.
Type - FRP (panel) or HDPE (round) etc.
INTERNAL Cold Water System
Storage Tank:

Component:
 Incoming Pipe
 Dropper Pipe
 Overflow Pipe (Paip limpah / Paip Amaran)
 The size of Overflow pipe > size of Incoming Pipe
 Scour Pipe (Paip cuci)
 Tank Cover / Penutup tangki
Water Tank ( < 4,500 liter)

Injap bebola

75mm 50mm Paip limpah /


Injap paip amaran
penahan

Paip
masuk Paip keluar

Injap penahan
Paip cuci
Water Tank ( > 4,500 liter)
Paip masuk
Paras amaran
Paras limpah
50mm
Paras air 50mm
Paip amaran

Paip limpah

Kedudukan ‘discharge point’


paip limpah / amaran hendaklah
di tempat yang boleh kelihatan
• Storage Tank – FRP panel
• Storage Tank – HDPE
Sistem Paip Air Dalaman
• Tangki simpanan
kehendak-kehendak tangki simpanan
* kedap air
* disangga sewajarnya
* dilindungi dari ‘ corrossion’

penutup tangki simpanan


* kalis habuk dan nyamuk
* kedap udara
* kedudukan yang sesuai
untuk diperiksa/dibersihkan
Sistem Paip Air Dalaman
• Tangki simpanan

– Ketinggian melebihi 2m, perlu disediakan


tangga di dalam dan luar tangki dari jenis
aluminium atau keluli tahan karat.

– Penyokong (reinforcement member) dalam


tangki jenis panel hendaklah dari jenis keluli
tahan karat (stainless steel).
Sistem Paip Air Dalaman
Kapasiti tangki simpanan
Types of building Minimum nominal Storage capacity
Dwelling houses (rural) 450 litres (100 gallons)
Dwelling houses and flats (urban) 680 litres (150 gallons)
Multi-storey flats with high level 140 litres (30 gallons)
bulk storage cistern
Low cost housing (approved by 450 litres (100 gallons)
Government)
Hostels 180 litres (40 gallons) per resident
Day School 30 litres (6.5 gallons) per head per
session
Boarding School 180 litres (40 gallons) per resident
Others one day’s supply or as decided by the
State Director
Nota: kapasiti tersebut berdasarkan kepada MWA design guidelines. Terdapat
pihak berkuasa air yang telah mengemaskini dan menambah kapasiti minima.
Sistem Paip Air Dalaman
Pemasangan Paip

Paip melalui ruang duduk, kawasan awam, tandas, dsb.


hendaklah disembunyikan (concealed) dalam saluran atau
kekotak, dalam siling, plaster dinding dan sebagainya.
Di pasang pada ketinggian 600mm (2 kaki) dari aras lantai.
Tidak bersilang dengan pendawaian elektrik dan paip
sanitari.
Ujian tekanan sehingga 15 bar hendaklah dijalankan pada
sistem paip.
Sistem Paip Air Dalaman
Bahan-Bahan Paip
Penggunaannya bergantung kepada sifat air atau keadaan
tanah dimana ia ditanam.
Paip ‘stainless steel’ dan ‘copper’ sesuai untuk air panas
Paip plastik seperti ABS, uPVC dan HDPE lebih tahan
karat dan senang dipasang tetapi mudah rosak jika terdedah
kepada cahaya matahari
Penggunaan juga bergantung kepada kos dan kelulusan
Pihak Berkuasa Air
Penggunaan paip ‘galvanised iron’ (G.I) tidak digalakkan
lagi oleh kerana masalah karat (corrosion)
Sistem Paip Air Dalaman
Cold
Types Of Corrosion Pressure Shock Chemical Bending Hot Water
Water
Pipes Resistance Resistance Resistance Resistance (Flexibility) Plumbing
Plumbing
Easy
ABS V.Good General General Good (but spring Yes No
back)
Easy
UPVC V.Good General General Good (but spring Yes No
back)
Easy
HDPE V.Good General General Good (but spring Yes No
back)
STAIN-
LESS V.Good High Strong Good No Yes Yes
STEEL

COPPER V.Good High Strong Good No Yes Yes


Sistem Paip Air Dalaman
Penyambung
Jenis-jenis penyambung

 Cement solvent joint - AC


 Sambungan berbibir (flanged joint) – M.S
 Sambungan bersekeru (screwed joint) - GI
 Sambungan berpatri (welded joint) - MS
 Spigot socket, dll - CI
Sistem Paip Air Dalaman
Pepasangan (fittings)
Mesti diluluskan oleh PBA dan SIRIM
Contoh:
Pili (tap)
Injap penahan (stop valve)
Injap bebola (ball valve)
Sisten simbah (flushing cistern)
Injap simbah (flush valve)
dll.
Sistem Paip Air Dalaman
Injap penahan (stop valve)

Perlu dipasang dikedudukan seperti berikut:


 Sebelum miter air
 Inlet dan outlet tangki
 Tiap-tiap cabang paip
 Tiap-tiap inlet ke sisten simbah
 Tiap-tiap 5 pepasangan ( untuk penyenggaraan )

Mempunyai saiz yang sama dengan paip

Terletak dikedudukan yang sesuai dan senang digunakan


Sistem Paip Air Dalaman
Flush valve (injap simbah)

Boleh digunakan bagi menggantikan sisten simbah untuk


tandas awam, pejabat dsb.
 Tidak perlu tangki sisten
 Lebih kemas
 Paip dan injap tertutup (concealed)
 Memerlukan tekanan yang lebih tinggi dari sisten biasa (>3.25m
head)
 Kos lebih mahal
Sistem Paip Air Dalaman
Flush valve (injap simbah)

 Low pressure W/C flush valve (tanpa penggunaan pam)

Requirement W/C flush valve

a) Dynamic/operating head
3.25 m.
at the inlet of flush valve
b) Flow rate ( Q ) 1.8 litres/sec.
Sistem Paip Air Dalaman
Dual flushing cistern

Bagi menjimatkan air, kerajaan mewajibkan


penggunaan sisten simbah tidak melebihi 6.0 liter setiap
simbah bagi projek-projek baru.

Sisten 2 simbahan (dual flush) digalakkan untuk


digunakan iaitu 6liter/3liter.
Sistem Paip Air Dalaman
Bekalan ke Bangunan berbilang tingkat

Vent pipe
(Air Bleeding
Storage Storage
Tank 1 Tank 2 Pipe)

Paip agihan

Paip penghantaran
WB SH KT
WC

Tangki
Miter air sedutan Miter
pukal individu
Pam

legend:
MULTI-STOREY WC – water closet
Paip awam Injap sekat hala
WB – wash basin
SH – shower
KT – kitchen tap
Sistem Paip Air Dalaman
Bangunan melebihi 10 tingkat
Vent pipe
Storage Storage (Air Bleeding
Tank 1 Tank 2 Pipe)
Tangki pecah tekanan atau injap
Downpipe
mengurangkan tekanan diperlukan
bagi mengelakkan pepasangan
mengalami kerosakkan akibat tekanan
tinggi.
Meter individu di setiap tingkat.
PBA hanya baca meter pukal (bulk
meter) dan selenggaraan sehingga ke
meter pukal sahaja.
Miter
Paip penghantaran individu

Tangki sedutan
Miter air
pukal Pam

Paip awam
Injap sekat hala
Sistem Paip Air Dalaman
Bagi tekanan yang boleh
mencapai ke aras tinggi
bangunan tanpa sistem TANGKI SIMPANAN
(1 HARI)
pam, miter individu boleh SELENGGARAAN SELENGGARAAN
diletakkan di luar. OLEH JBA/PBA OLEH PEMILIK

MITER
INDIVIDU
PAIP JBA/PBA

Semua meter individu diletakkan di tingkat bawah.


Semua unit perlu mempunyai tangki individu untuk penggunaan sehari.
Sesuai untuk sistem gravity sahaja. (Kebiasaannya bangunan yang
4-tingkat ke bawah, seperti rumah kedai.)
Tangki penyuap
(feeder tank) untuk
‘flush valve’
Tangki Paip cuci &
simpanan paip limpah

Paip agihan ke
Paip agihan
injap simbah (flush
valve)
Paip masuk Tingkat 10

Tingkat 9
Tangki pecah
tekanan Tingkat 8

Tingkat 7

Tingkat 6

Tingkat 5

Tingkat 4

Tangki
sedutan Tingkat 3

Sistem pam
Tingkat 2

Tingkat 1
Miter pukal
Contoh sistem paip air dalaman yang mempunyai feeder tank
Paip utama
ke flush valve
Terima kasih