You are on page 1of 3

Calculations

(1) Self-excited Induction generator

Capacitance required to obtain;

1) Rated voltage of 240V at the given speed.

C= 66μF

2) Rated voltage of 240V at the rated frequency of 50 Hz.

| Ic | = | VCω |

Here as | Ic| = | Im |,

when V =240V, f = 50 Hz from the graph we can obtain Im = 2.35A

Also ω = 2πf =2π*50 =314.159 rads-1

2.35
Then, C=
240 * 314.159

= 31.2 μF

(2) Grid Connected Induction Generator

Efficiency

Input Power = Ґ*ω

Output Power  100%


Efficiency = InputPower

Sample Calculation

ω = 3050 rpm Wattmeter Reading = 0.302 kW Ґ= 1.9Nm

3050 * 2 * Ï
Input Power = 1.9 Nm * ( ) rad/s
60
= 606.85 W

302  100%
Efficiency =
606.85
= 49.77%
Power Factor
Re alPower
Power Factor = ApperantPower

Apparent Power = VI

Sample Calculations

V = 208V I =1.50A Reading = 0.302 kW

302
Power Factor =
208 * 1.50
= 0.97

Speed (rpm) Efficiency Power Factor


3000 0 0
3012 7.51 0.19
3020 14.98 0.36
3030 25.22 0.61
3040 35.39 0.76
3050 49.77 0.97