Isolated Footing by Limit State Method

Data Required/assumed
Safe Bearing Capacity of the soil = 100 KN/m2 P = 300 Kn
M20 fck = 30 N/mm2 Mx = 56 Kn-m
FE415 Fe = 415 N/mm2 My = 67 Kn-m
Depth of soil above footing = 2.5 m Zx = 2.60 m3
Provide Overal Depth of footing = 350 mm Zy = 2.60 m3
d = 300 mm net soil reaction = 95.23 KN/m2
Min Eff. depth required = 175 mm net soil reaction = 48
Footing dimensions Considering only loads
B = 2.5 m
L = 2.5 m
Column dimensions
a = 500 mm
b = 500 mm
Load from Column = 300 KN
Net soil reaction = 95.23 KN/m2
B. M. at the face of column =
x = 1 Mxx = 71.424 KN-m/m length
y = 1 Myy = 71.424 KN-m/m length

Xumax = 144 mm
Mulimit = 372.50 Kn-m
Mulimit>M, Hence Section is Under reinforced
Designing as Under reinforced section xu=0.87.fy.Ast/0.36.fck.b
Astx = 681.13 mm2
Asty = 681.13 mm2
Ast min = 420 mm2 Astlimit= 4307.44 mm2
Provide Astx 10 mm bar @ 110 mm C/C AstxW.S.M 766.76 mm2
Provide Asty 10 mm bar @ 110 mm C/C 44.6E+6 KN-M
681.13 mm2

Check for One Way Shear


681.13
Factored Shear Vu = 99.99 KN
Tv = 0.333 p= 0.227
Tc = 0.354 From Code Using formula
Tv<Tc, Hence safe

Check for Two Way Shear


Two way shear = 801.38
Tvv = 0.835
Allowable shear = 1.369
Tvv < Tcc hence safe

Check for bearing


Bearing stress at the contact of column and footing
= Axial load/area of column = 1.20 N/mm2
Permissible Bending Stress = 27.00 N/mm2
Bearing stress calculated < permissible bearing stress hence No Dowel to be used