Bearing Capacity Analysis of Spread Footings

B 1.5 m Footing width (= diameter for a circular foundation)
L 1.5 m Footing length
Df 1.5 m Footing depth
 0 deg Base Inclination 
 0 deg Ground Inclination
i 0 deg Inclination of the load on the foundation with respect to the vertical
c 30 kPa Soil cohesion
 30 deg Soil friction angle
 18 kN/m3 Soil unit weight
Dw 1 m Depth to groundwater
FS 1 Factor of safety

Bearing Capacity Factors Shape Factor Depth Factor Load Inclination Factor Base Inclination Factor Ground Inclination Factor


Nc 30.13963 sc 1.610529 dc 1.005483 ic 1 bc 1 gc 1
Nq 18.40112 sq 1.57735 dq 1.003957 iq 1 bq 1 gq 1
N 22.40249 s 0.6 d 1 i 1 b 1 g 1
4000
q 27 kPa
b 8.19 kN/m3 3500

3000
Results
2500
Allowable bearing capacity Allowable column load

qadm, kPa
qu 2333.548 kPa P 5189.733 kN Bmin 1 m 2000
qu(net) 2306.548 kPa Bmax 4 m 1500
qadm 2306.548 kPa
Run 1000
Footing Shape: Square
500 Footing Shape: Rectangular
Analysis Point
0
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5