SAMGONG-MITSUBISHI
SELFJECTOR
GENIUS-SERIES
This manual has been edited primarily to give instructions for processing mineral oils
such as fuel oils and lubricating oils.
The instruction manual is a guide book for using an automatic discharge type oil purifier,
the ƎSAMGONG-MITSUBISHI SELFJECTOR GENIUS SERIESƎ (hereinafter referred to as
the SELFJECTOR).
The SELFJECTOR is a centrifugal separator rotating at high speeds. Please read through
this manual and obtain a complete understanding of the contents of the manual before
using the SELFJECTOR.
Handle the SELFJECTOR safely and operate it in the right way to get the best service.
NOTE
The Part 4 manuals(Operation Manual 3) deal with the following types of the automatic control
system. When you purchase the SELFJECTOR controlled by one of these control system, the
associated operation manual of Part 4 will be supplied.
Prior to use, carefully read through the ƎPrecautions for SafetyƎ, and operate the SELFJECTOR in the
right way.
The precautions for safety in this instruction manual are intended for enabling the user to use the
SELFJECTOR safely and properly, and protecting the user from personal injury and damage. Carefully
read through the precautions until you have a complete understanding before performing and job or
procedure for operation or maintenance of the SELFJECTOR.
In this instruction manual, the precautions are headed by the following symbols. Since all of them
are important precautions associated with safety, be strictly observe them.
CAUTION: Indicates a hazardous situation which, if not heeded, may result in minor
! or moderate injury or damage to the machine or facilities.
NOTE: Indicates the items which should be done or which will be of help if kept in mind for
operating the machine or performing work.
CAUTION
!
The automatic control panel is a part of the equipment designed for automatic operation
of the SELFJECTOR. Improper handling of the panel could cause malfunctions and
jeopardize your safety. Before operation, maintenance and inspection of the panel,
thoroughly read through this manual and pay special heed to your safety when using the
panel.
y Do not attempt disassembly and reworking of the control panel without permission
of our company.
y Before proceeding with wiring, check to ensure that the input power supply to the
system is OFF.
There is danger of an electric shock.
y Connect the equipment to the hull in an electrically effective way by use of the
ground terminal of the panel.
(Make sure that the equipment is grounded.)
y Check to ensure that the rated voltage and frequency of the panel coincide with
those of the power supply.
The control panel is used for automatic purification of the feed oil by the Samgong-Mutsubishi
SELFJECTOR. It is so designed that, if a trouble like an abnormal oil leakage or sludge discharge
failure(fail to open the bowl) occurs during operation, the supply of the feed oil and then the
SELFJECTOR may be stopped automatically.
The control panel outputs feeding signal to the Multi-Monitor(MM), and has separated water discharged
in response to alarm(water detection) signal from the Multi-Monitor. If the number of times water
discharge is abnormally large, the control panel automatically shuts down the SELFJECTOR after
completion of the discharge process. For detailed information on the Water Detector Function(WD) of the
Multi-Monitor, refer to OPERATION MANUAL 2.
Table 4.-1
MAIN MODULE
Power
T / B Module
1. Display & CPU Module Supply
2. I/O BOARD
! CAUTION
Never mount/dismount the CPU & Display Module, I/O Module, T/B Module or Power Supply unit
while the power is on.
Fig. 4.-1 G
The front panel configuration and functions of the automatic control panel are described below.
5.4
5.6
5.2
5.6
5.1.③
5.1.①
5.1.②
Fig 5.-1
5.l. SWITCHES AND PUSH BUTTONS IN THE FRONT OF THE CONTROL PANEL
① CONT. SOURCE OFF / ON
As a switch on the auto control panel, it turns ON / OFF power source of the auto control panel.
② EM'CY STOP
As a push button on the auto control panel, it stops a purifier directly.
ྛ MM FUNCTION OFF/ON
This selector switch is used for ON/OFF control of feeding signal output from the control panel to
the Multi-Monitor.
When the "MM FUNCTION SWITCH" is off position, feeding signal is not outputted from the control
to the Multi-Monitor even if the SELFJECTOR is on feeding.
G
G
5.2. PUSH BUTTONS ON PFC-A
ྙ AUTO START
As a luminescent push button switch, it starts automatic purifying, and the indicating
AUTO lamp is on while automatic purifying is operating.
START G
G
ྚ AUTO STOP
As a luminescent push button switch, it pauses automatic purifying and stops the
AUTO purifier after discharging sludge completely.
STOP G
G
ྛ DIS. TEST
As a luminescent push button switch, it has a function to discharge sludge, and it can be
operated during feeding cycle of the purifier, and discharges sludge. Also, in the
DIS.T timer/counter setting mode, use this key to move the cursor to the left digit.
G
ྜ ALARM RESET
As a luminescent push button switch, it functions as a common alarm lamp and as an
ALARM alarm reset. The indicating lamp is on when an alarm is happened, and off
RESET when reset by a push after the alarm is removed.
G
ྜྷ MON.
As a push button switch, use this switch when you monitor the
MON proceeding condition of functions (timer, counter) which you want to execute.
G
G
ྞ SET
As a push button switch, use this switch together with "ENT" switch to set or to change
the value of a timer or a counter.
SET
G
G
G
SELFJECTOR Instruction Manual Operation Manual 3
5-2
G
ྟ ENT
As a push button switch, use this switch together with "SET" switch to set or to change
ENT the value of a timer or a counter.
G
G
ྠ Ÿ, ź
As a push button switch, use this switch to seek addresses of needed timer
or counter.
Ÿ ź
Table 5-1
Display &
I/O Module T/B Module Power Supply
CPU Module
It transmits the Connecting with I/O It supplies control
It changes or sets inputs of a sensor or a modules, there is a source of PFC which
the values of a timer switch to display & terminal block to conducts general
or a counter, indicates CPU module, controls enable to connect with controls of auto
the states of I/O and commands from yard cable. control panel.
control panel display & CPU module
generally. and outputs to T/B
module.
1) INPUT
ྙ MOTOR RUN : Stay ON during operation of the motor of the SELFJECTOR.
2) OUTPUT
ྙ SV1 : Comes on when solenoid valve for water for opening bowl is energized (for total discharge).
ྚ SV2 : Comes on when solenoid valve for water for closing bowl is energized.
ྛ SV3 : Comes on when solenoid valve for sealing water / replacement water is energized.
ྜ SV4 : Comes on when solenoid valve for feed valve is energized.
ྜྷ SV9 : Comes on when solenoid valve for water for opening bowl is energized (for partial discharge).
(GSH-1 Type only)
ྞٻڕٻڍڈڥڮڍٻComes on when series operation mode.
(Option Specification)
3) ALARM
ྙ LEAKAGE ALARM : Comes on when feed liquid or light liquid has accidentally flowed.
ྚ NO-DIS. ALARM : Comes on when sludge discharge is faulty.(GBC-1 Type option)
ྛ HIDENS ALARM : Comes on when error signal from Water Detector control unit is inputted.
(GSH-1 Type only)
ྜ T(H) : Comes on when the processing oil at the inlet of the purifier has a high temperature.
ྜྷ T(L) : Comes on when the processing oil at the inlet of the purifier has a low temperature.
ྞ VIB-AL : Comes on when the vibration switch is activated. (Detector : option)
ADDR. DATA
NOTE
ADDR. DATA
NOTE
1. This is convenient to know the elapsed time during purifying operation. For example, when
it is counted 1 time, indicator of DATA indicates 0001.
2. By pressing the “MON” button on automatic operation when “tP” is displayed on indicator
of ADDR, the operating status of the timers can be monitored in sequence.
3. As other buttons except “MON” button are not operated during monitoring, push “MON”
button again and change the values of timer or counter into another values or monitor the
other timer or counter.
ADDR. DATA
Unit : minute
ADDR. DATA
Unit : minute
.
NOTE
The counters which can be monitored in the both of 0.1 second and minute unit are as follow:
ITEM Counter No.
Intermittent water supply C014
Discharge interval C015
Monitoring time C022
Detection counter reset C026
Unit : °C
ADDR. DATA
Unit : °C
NOTE
If Temp. high or Temp. low alarm are unnecessary, set “PASS”
“PASS” is indicated by setting 201 °C.
Unit : °C
ADDR. DATA
Unit : °C
NOTE
As other button except “MON” button are not operated during monitoring , push “MON”
button again and change the values of timer or counter into another values on monitor the
other timer or counter.
Maximum setting value : from 0 °C to 200 °C
ADDR. DATA
ADDR. DATA
ADDR. DATA
The times to be set for the timers vary with following factors.
It is therefore necessary to set the timers to match the field conditions. When a test run and adjustments
are performed by Samgong service personnel, the timers are set to the proper values suitable for the
field conditions before handover. If changes occur in the properties of feed oil thereafter, refer to the
following explanations and change the set times properly.
Item Model SJ10G SJ20G SJ30G SJ50G SJ60G SJ70G SJ100G SJ120G SJ150G
NOTE
1. The times for sealing water and replacement water timers shown in the table assume that
the supply flow rate is 8L/min for the SJ10G-30G, 12L/min for the SJ50G-70G, 16L/min for
the SJ100G-120G, and 18L/min for the SJ150G. Be sure to measure he actual flow rate
and set the times to proper values.
2. There is not a washing process in the case of the fuel oil purifier.
Table 7-4 shows the general discharge intervals for processing fuel oil and lubricating oil. The table is
intended for general guidance.
Table 7-4
Fuel oils Lubricating oils
Fuel oil C Cross-head Trunk piston
Fuel oil A
(380mm2/s at 50°C) engine engine
Sludge discharge times
12 24 12 24
(times/day)
Discharge interval
120 60 120 60
(min)
Bowl washing times
0 0 2 4
(times/day)
Item Model SJ10G SJ20G SJ30G SJ50G SJ60G SJ70G SJ100G SJ120G SJ150G
NOTE
1. Timer setting for sealing water and replacement water in the above list are based on the
feed rate at 8 L/min for SJ10GH to 30GH, at 12 L/min for SJ50GH to 70GH, at 16 L/min for
SJ100GH and 120GH and at 18 L/min for SJ150GH. For practical setting, always measure
the flow rate actually and select proper values accordingly.
2. Fuel oil purifier have no regulating water feeding process and bowl washing processes.
NOTE 1 : For discharge intervals, refer to Table 7-7 standard discharge intervals for general guidance.
NOTE 2 : Please use C021 by fixing to 1.
NOTE 3 : In case of purifier operation by automatic type GSH-1, please set the setting values of the
timers T011, T012, T013, C022, C026 and C027 to 0.
NOTE
z Timer setting for sealing water and replacement water in the above list are based on the feed
rate at 8 L/min for SJ10GH to 30GH, at 12 L/min for SJ50GH to 70GH, at 16 L/min for SJ100GH
and 120GH and at 18 L/min for SJ150GH. For practical setting, always measure the flow rate
actually and select proper values accordingly.
z Prior to purifier operation, do the following setting.
Select the gravity disc to match the type of oil to be treated.(Refer to Operation Manual 2)
Fully Close the circulation line back pressure valve attached to the purifier and fully open
the shut off valve.
Set the Water Detector selector dial to Water / heavy liquid detector function position and
the Water Detection output switch to OFF. (Refer to Operation Manual 2)
The inside of the bowl can be cleaned after every few total discharge operation in order to remove
unevenly accumulated sludge and dirt.
Table 7-8 shows the standard bowl washing counters for general guidance in processing fuel and
lubricating oils.
Table 7-8
Fuel oils Lubricating oils
Fuel oil C Cross-head
Fuel oil A Trunk piston engine
(380mm2/s at 50˚C) engine
Bowl
washing 0 times 0 times 6 times 6 times
counter
NOTE
The Bowl washing count shown above is set so that washing interval will be 24 hours.
The Bowl washing interval is given by : (Except when the Bowl washing count is 0.)
G
! CAUTION
Refer to Table 7-3, 7-4 and make sure that each timer is set to appropriate values for actual
operating conditions(feed oil type, SELFJECTOR model number, and available water pressure
and etc.).
Specifically, the discharge interval time "C015" should be set to fit the sort of feed oil since the
timer influences the amount of sludge accumulated in the bowl.
(for the change of set timer, refer to Table 7-4).
When you perform setting change of an option function, please turn [OFF] the power supply of a
control panel for safety.
Make sure that the selection of the gravity disc is correct.
Make sure position of the switches in the Multi-Monitor(MM) is right.
Make sure the set pressure value of the operating water reducing valve is right. G
For the SELFJECTOR main unit and relevant valves refer to the separate "Operation Manual2".
During feeding operation, a sludge discharge test can be performed at any time irrespective of the
elapse feed time. When push button ƎDIS-TESTƎ on the automatic control panel is pressed, the
SELFJECTOR will enter the sludge discharge process in the same way as upon expiry of the
discharge interval timer (C021).
As soon as the sludge discharge process is completed, the SELFJECTOR will directly be restored
to the automatic operation.
! CAUTION
When the SELFJECTOR is shut down because of an emergency, No opening Bowl, abnormal
vibration or overload, it will stop operation without discharging the sludge accumulated in the
bowl. If the SELFJECTOR is directly restarted, the bowl might lose balance and cause a
hazardous situation. For this reason, be sure to disassemble the bowl and remove the sludge
according to ƎOperation Manual 2Ǝ before restarting operation.
! CAUTION
The automatic control panel is electrically interlocked with the starter. Therefore, the automatic
control panel is not operable unless the SELFJECTOR is started by the starter.
To operate the SELFJECTOR, without using the automatic control panel, manually operate the
individual solenoid valves.
In cases of emergency, press push button "EM'CY STOP" on the automatic control panel.
In any of the processes, the power supply to the SELFJECTOR will be cut off, and all the solenoid valves
will be closed to stop operation.
G
9.1. OPERATION PREPARATION
G
!
G
CAUTION
Refer to Table 7-5, 7-6, 7-7, 7-8 and make sure that each timer is set to appropriate values for actual
operating conditions (feed oil type, SELFJECTOR model number, and available water pressure and etc.).
Specifically, the discharge interval timer "C015" should be set to fit the sort of feed oil since the timer
influences the amount of sludge accumulated in the bowl.
(For the change of set timer, refer to Table 7-7).
For the SELFJECTOR main unit and relevant valves refer to the separate "Operation Manual 2".
Make sure that the gravity disc for HIDENS is installed in the SELFJECTOR.
Make sure that the circulation line back pressure valve is fully opened and shut off valve is fully closed
attached to the SELFJECTOR.
Make sure position of the switch in the Multi-Monitor(MM)is right.(Water detector selector dial, Water
detection output switch and etc).
Make sure the set pressure value of the operating water reducing valve is right.
G
9.2. HIDENS SYSTEM OPERATION
Step 1. Start the SELFJECTOR by separately installed starter.
G
Step 2. Set the power switch on the automatic control panel to "ON".
G
Step 3. Set the timer and counter in the panel.
G
Step 4. The ƎCONT. SOURCEƎ pilot lamp will come on.
Check the ammeter of the starter to confirm that the SELFJECTOR has reached the rated
speed. Thereafter, press push button ƎAUTO STARTƎ provided on the control panel.
G
Step 5. Each timer of purifier controller in the automatic control panel works in the following order to
perform continuous purifier operation.
(Refer to the attached Section Automatic Operation Flow and 9.7. Timing Chart as well.)
When T000 is timed up(When the Bowl washing counter C023 have expired).
Interval timer T000 will restart operation.
Output of the "Discharge process" signal to the Multi-Monitor is stopped.
When T000 is timed up.
The solenoid valve SV3 opens to supply the bowl washing water.
Solenoid valve SV2 will close to stop supplying the bowl closing water.
Bowl washing water timer T004 begins operating.
When T004 is timed up.
Solenoid valve SV3 will close to stop supplying the bowl washing water.
At the same time, solenoid valve SV1 will open to supply the bowl opening water
and open the bowl to discharge washing water.
Bowl opening water timer T001 will start operation.
When T001 is timed up.
Solenoid valve SV1 will close to stop supplying the bowl opening water.
Solenoid valve SV2 will open to supply the bowl closing water and close the bowl.
At the same time, interval timer T000 will start operation.
When T000 is timed up.
Solenoid valve SV3 will open to supply the regulating water.
NOTEG
The fuel oil purifier dose not require the supply of Regulating water.G
Regulating water timer T003 will start operation.
Interval timer T000 will restart operation.G
When T003 is timed up. G
Solenoid valve SV3 will close to stop supplying the regulating water.
When T000 is timed up
Solenoid valve SV2 will close to stop supplying the bowl closing water.
Interval timer T000 will restart operation.
When T000 is timed up(When the bowl washing counter C023 have not expired.).
Solenoid valve SV3 will open to supply the regulating water.
Regulating water timer T003 will start operation.
The ƎDischarge processƎ signal output to the Multi-Monitor will be stopped.
NOTEG
The fuel oil purifier dose not require the supply of Regulating water.G
Interval timer T000 will restart operation.
Gཛྷ ཝ
G G
When a water detection signal is received from the Multi-Monitor, (When the Monitoring timer C022
have not expired).
Operation of discharge interval timer C015 will be stopped temporarily.
(Lapsed time is held.)
Monitoring timer C022 will be reset.
Solenoid valve SV4 will close to close the feed valve.
Solenoid valve SV2 will stay open to supply the bowl closing water.
Interval timer T000 will restart operation.
The ƎfeedingƎ signal output to the Multi-Monitor will be stopped.
The ƎDischargingƎ signal will be output to the Multi-Monitor.G
When T000 is timed up.G
Solenoid valve SV3 will open to supply the replacement water.
Replacement water timer T012(for partial) will start operation.
When T012 is timed up.
Solenoid valve SV3 will close to stop supplying the regulating water.
Solenoid valve SV2 will stay open to supply the bowl closing water and close the bowl.
Interval time T000 will start operation.
When T000 is timed up.
Solenoid valve SV9 will open to supply the bowl opening water(for partial) to the bowl
and discharge sludge and separated water.
Opening bowl timer T011(for partial) will start operation.
When T011 is timed up.
Solenoid valve SV9 will close to stop supplying the bowl opening water(for partial).
Solenoid valve SV3 will open to supply regulating water.
Regulating water timer T013(for partial) will start operation.
Interval time T000 will start operation.
When T013 is timed up.
Solenoid valve SV3 will close to stop supplying the regulating water.
When T000 is timed up.
Solenoid valve SV2 will close to stop supplying the bowl closing water.
The ƎDischarge processƎ signal output to the Multi-Monitor will be stopped.
Interval timer T000 will restart operation.
When T000 is timed up.
(1) Operation of discharge interval timer C015 will be restarted.
(2) Monitoring timer C022 will start operation.
(3) During operation of discharge interval timer C015, the bowl opening water will be
intermittently supplied.
In other words, the following process will be repeated: Operation of C014 ĺ Expiry
of C014 ĺ Operation of T016(open SV2 to supply the bowl closing water) ĺ Expiry
of T016(closes SV2 to stop supplying the bowl closing water) ĺ Operation of C014.
(4) The ƎFeedingƎ signal will be output to the Multi-Monitor.
! CAUTION
When SJ10GH to SJ150GH types are used in the total discharge mode (purifier operation), select an
appropriate gravity disc that fits the specific gravity of feed liquid and install it in position.
Then, fully open the shut off valve and fully close the circulation line back pressure valve. After that, set the
Water Detector selector dial to No working position and the water detection output switch to OFF position.
When T000 is timed up(when the bowl washing counter C023 have expired.)
Interval timer T000 will restart operation. G
The ƎDischarge processƎ signal output to the Multi-Monitor will be stopped.
When T000 is timed up.
Solenoid valve SV3 will open to supply the bowl washing water.
Bowl washing timer T004 will start operation.
Solenoid valve SV2 will close to stop supplying the bowl closing water.G
ཛG G ཛྷ
When T000 is timed up(When the bowl washing counter C023 have not expired).
Solenoid valve SV3 will open to supply the sealing water.
Sealing water timer T003 will start operation.
Interval timer T000 will restart operation.
The ƎDischarge processƎ signal output to the Multi-Monitor will be stopped.
When T000 is timed up.
Solenoid valve SV2 will close to stop supplying the bowl closing water.
G
G
When push button ƎAUTO STOPƎ provided on the control panel is pressed, the SELFJECTOR will
automatically stop after going through the replacement water process and then discharging sludge.
(During feed operation, the feed oil supply is first stopped.)
G ! CAUTION
In the cases of emergency stop, defective discharge stop and overload stop, the SELFJECTOR
stops without discharging sludge accumulated within it.
When restarting, be careful.
Because it is very dangerous that the sludge within the bowl sometimes breaks the balance of
bowl. By all means, refer the Instruction Manual of SELFJECTOR itself, overhaul the bowl to
remove the sludge, then try to restart.
! CAUTION
Remove the cause of an alarm before pressing push button ƎALARM RESETƎ
Press push button ƎALARM RESETƎ provided on the control panel to reset the alarm circuit.
This alarm will be generated by the Leakage Monitor Function(LM) of the Multi-Monitor when the
light liquid side pressure falls due to outflow of the feed oil or processed oil toward the heavy
liquid side or sludge chute side of the SELFJECTOR during feeding operation. When this alarm
occurs, the SELFJECTOR will automatically stop operation after discharging sludge.
Table 10-1
Alarm Cause of alarm Process
Oil 1. The bowl failed to close because of a fault in the 1. Refer to the separate
leakage SELFJECTOR. "Maintenance Manual".
2. The bowl closing water was not supplied because 2. Repair or replace the valve
solenoid valve SV2 failed to open. with a non-defective one.
3. The required sealing water was not supplied because 3. same as above.
solenoid valve SV3 failed to open.
4. The required sealing water was not supplied because the 4. Adjust the setup time of the
set time of the sealing water timer "T003" was too short. timer.
5. solenoid valve SV2 or SV3 failed to open because of a 5. Replace the output module
defective output module in the control panel. with a spare one.
6. Defective Multi-Monitor(MM) 6. Refer to the separate
"Maintenance Manual".
7. Defective water or air system 7. Refer to the separate
"Maintenance Manual".
This alarm occurs when the Discharge Detector Function(DD) of the Multi-Monitor fails to detect
discharge despite the fact that a DISCHARGE SLUDGE signal was sent to the bowl opening
solenoid (SV1, SV9 (GSH-1 Type only)).
When this alarm occurs, the SELFJECTOR will stop operation immediately.
Table 10-2
This alarm occurs when the water detection count is abnormally high.
When the Multi-Monitor detects the water content in the bowl, its water detection signal is input to
the CPU board and a water discharge operation is effected, when the water detection setting
counter (C027) adds one time to the current count. C027 is reset every time the water detection
count reset timer(C026), which is repetitively actuated during automatic operation, expires. If the
water content of the feed oil is abnormally high, water detection is repeated within a short period of
time, C027 counts up to give an abnormal water content alarm. When this signal is issued, the
SELFJECTOR is automatically stopped after discharging sludge.
This alarm occurs when the temperature of the processing oil becomes higher or lower during
feeding operation than alarm setting value. Even if this alarm occurs, the SELFJECTOR will
continue to operate.
To clear the alarm, remove the cause of the alarm. Thereafter, press push button ″ALARM
RESET″ on the control panel.
This alarm occurs when the vibration switch is operated by occurrence of an abnormal vibration in
the SELFJECTOR.
As soon as the alarm occurs, the SELFJECTOR will stop operation immediately.
Disassemble and check the SELFJECTOR and remove the cause of the alarm. Thereafter, press
push button ″ALARM RESET″ on the control panel and perform the procedures to restart
operation.
Table 10-3
Alarm Cause of alarm Corrective Action
Abnormal vibration 1. Abnormal vibration of the bowl occurred 1. Refer to the separate
(VIB-AL) because of a fault in the SELFJECTOR. ″Maintenance Manual″.
3. The reset coil of the vibration switch was 3. Replace output module.
not operated.
Fig. 11-1
Fig. 11-2
z The attached drawing contains all of the optional detectors and circuits, some of which may not
be provided or used, depending on the specification for the SELFJECTOR you have purchased.
Refer to the drawing in the final drawing as well.
INSTRUCTION MANUAL
(OPERATION MANUAL 3)
G
G