You are on page 1of 7

Version 7.1.

PVsyst - Simulation report


Grid-Connected System

Project: Goianul nou mai


Variant: New simulation variant
No 3D scene defined, no shadings
System power: 5.39 kWp
Goianul Nou - Republic Of Moldova

Author
Project: Goianul nou mai
Variant: New simulation variant

PVsyst V7.1.0
Simulation date:
27/05/21 15:31
with v7.1.0

Project summary
Geographical Site Situation Project settings
Goianul Nou Latitude 47.11 °N Albedo 0.20
Republic Of Moldova Longitude 28.91 °E
Altitude 163 m
Time zone UTC+2

Meteo data
Goianul Nou
Meteonorm 7.3 (1991-2010), Sat=100% - Synthetic

System summary
Grid-Connected System No 3D scene defined, no shadings
Simulation for year no 1

PV Field Orientation Near Shadings User's needs


Fixed plane No Shadings Monthly values
Tilt/Azimuth 30 / -40 °

System information
PV Array Inverters
Nb. of modules 14 units Nb. of units 1 Unit
Pnom total 5.39 kWp Pnom total 5.00 kWac
Pnom ratio 1.078

Results summary
Produced Energy 6.62 MWh/year Specific production 1228 kWh/kWp/year Perf. Ratio PR 87.19 %
Solar Fraction SF 37.11 %

Table of contents
Project and results summary 2
General parameters, PV Array Characteristics, System losses 3
Main results 4
Loss diagram 5
Special graphs 6
Predef. graphs 7

27/05/21 PVsyst Licensed to Page 2/7


Project: Goianul nou mai
Variant: New simulation variant

PVsyst V7.1.0
Simulation date:
27/05/21 15:31
with v7.1.0

General parameters
Grid-Connected System No 3D scene defined, no shadings

PV Field Orientation Horizon


Orientation Models used Free Horizon
Fixed plane Transposition Perez
Tilt/Azimuth 30 / -40 ° Diffuse Perez, Meteonorm
Circumsolar separate

Near Shadings User's needs


No Shadings Monthly values

Jan. Feb. Mar. Apr. May June July Aug. Sep. Oct. Nov. Dec. Year
500 500 500 500 500 500 500 500 500 500 500 500 6000 kWh/mth

PV Array Characteristics
PV module Inverter
Manufacturer JA solar Manufacturer Huawei Technologies
Model JAM60-S20-385-MR Model SUN2000L-5KTL
(Original PVsyst database) (Original PVsyst database)
Unit Nom. Power 385 Wp Unit Nom. Power 5.00 kWac
Number of PV modules 14 units Number of inverters 1 Unit
Nominal (STC) 5.39 kWp Total power 5.0 kWac
Modules 2 Strings x 7 In series Operating voltage 90-500 V
At operating cond. (50°C) Max. power (=>40°C) 5.50 kWac
Pmpp 4918 Wp Pnom ratio (DC:AC) 1.08
U mpp 223 V
I mpp 22 A

Total PV power Total inverter power


Nominal (STC) 5 kWp Total power 5 kWac
Total 14 modules Nb. of inverters 1 Unit
Module area 26.2 m² Pnom ratio 1.08

Array losses
Thermal Loss factor DC wiring losses Module Quality Loss
Module temperature according to irradiance Global array res. 167 mΩ Loss Fraction -0.8 %
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC
Uv (wind) 0.0 W/m²K/m/s

Module mismatch losses Strings Mismatch loss Module average degradation


Loss Fraction 2.0 % at MPP Loss Fraction 0.1 % Year no 1
Loss factor 0.4 %/year
Mismatch due to degradation
Imp RMS dispersion 0.4 %/year
Vmp RMS dispersion 0.4 %/year

IAM loss factor


Incidence effect (IAM): Fresnel AR coating, n(glass)=1.526, n(AR)=1.290

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.999 0.987 0.962 0.892 0.816 0.681 0.440 0.000

27/05/21 PVsyst Licensed to Page 3/7


Project: Goianul nou mai
Variant: New simulation variant

PVsyst V7.1.0
Simulation date:
27/05/21 15:31
with v7.1.0

Main results
System Production
Produced Energy 6.62 MWh/year Specific production 1228 kWh/kWp/year
Performance Ratio PR 87.19 %
Solar Fraction SF 37.11 %

Normalized productions (per installed kWp) Performance Ratio PR

Balances and main results

GlobHor DiffHor T_Amb GlobInc GlobEff EArray E_User E_Solar E_Grid EFrGrid
kWh/m² kWh/m² °C kWh/m² kWh/m² MWh MWh MWh MWh MWh
January 32.7 19.82 -1.41 45.7 44.0 0.236 0.500 0.112 0.115 0.388
February 46.3 27.10 -0.38 58.0 56.3 0.300 0.500 0.133 0.157 0.367
March 95.0 50.65 4.58 111.5 108.8 0.564 0.500 0.184 0.365 0.316
April 133.8 65.88 10.68 145.4 142.0 0.715 0.500 0.222 0.474 0.278
May 174.7 84.97 17.03 180.3 176.3 0.861 0.500 0.255 0.584 0.245
June 188.0 74.90 20.15 185.1 181.2 0.869 0.500 0.251 0.595 0.249
July 193.3 82.42 23.09 197.0 192.8 0.916 0.500 0.258 0.634 0.242
August 165.6 63.81 22.51 178.1 174.3 0.830 0.500 0.234 0.575 0.266
September 112.2 56.13 16.02 130.1 127.2 0.630 0.500 0.208 0.405 0.292
October 72.7 34.08 10.93 91.8 89.4 0.453 0.500 0.162 0.277 0.338
November 37.4 22.61 5.25 50.7 48.8 0.255 0.500 0.119 0.127 0.381
December 23.8 15.04 -0.08 35.0 33.7 0.180 0.500 0.088 0.084 0.412
Year 1275.5 597.41 10.76 1408.6 1374.8 6.810 6.000 2.226 4.393 3.774

Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_User Energy supplied to the user
T_Amb Ambient Temperature E_Solar Energy from the sun
GlobInc Global incident in coll. plane E_Grid Energy injected into grid
GlobEff Effective Global, corr. for IAM and shadings EFrGrid Energy from the grid

27/05/21 PVsyst Licensed to Page 4/7


Project: Goianul nou mai
Variant: New simulation variant

PVsyst V7.1.0
Simulation date:
27/05/21 15:31
with v7.1.0

Loss diagram
1276 kWh/m² Global horizontal irradiation
+10.4% Global incident in coll. plane

-2.39% IAM factor on global

1375 kWh/m² * 26 m² coll. Effective irradiation on collectors

efficiency at STC = 20.61% PV conversion

7.41 MWh Array nominal energy (at STC effic.)


-0.20% Module Degradation Loss ( for year #1)
-1.14% PV loss due to irradiance level

-4.69% PV loss due to temperature

+0.75% Module quality loss

-2.12% Mismatch loss, modules and strings


(including 0% for degradation dispersion

-0.92% Ohmic wiring loss


6.81 MWh Array virtual energy at MPP
-2.73% Inverter Loss during operation (efficiency)
0.00% Inverter Loss over nominal inv. power
0.00% Inverter Loss due to max. input current
0.00% Inverter Loss over nominal inv. voltage
0.00% Inverter Loss due to power threshold
0.00% Inverter Loss due to voltage threshold
grid
-0.07% Night consumption
consumption
6.62 MWh Available Energy at Inverter Output

3.77 2.23 4.39 MWh Energy injected into grid

to user to user to grid


from grid from solar

27/05/21 PVsyst Licensed to Page 5/7


Project: Goianul nou mai
Variant: New simulation variant

PVsyst V7.1.0
Simulation date:
27/05/21 15:31
with v7.1.0

Special graphs
Daily Input/Output diagram

System Output Power Distribution

27/05/21 PVsyst Licensed to Page 6/7


Project: Goianul nou mai
Variant: New simulation variant

PVsyst V7.1.0
Simulation date:
27/05/21 15:31
with v7.1.0

Predef. graphs
System Output Power Tail Distribution

27/05/21 PVsyst Licensed to Page 7/7