GENERAL INFORMATION
1 Site Information
1.1 Address:*)
2 Customer References
4.2 Address:
5 Local regulations
5.1 Are there any special health and safety regulations that need to be
considered? Yes Casilla
Node✘ verificación
Casilla
N/Ade verificación
664
Casilla de664
verificación
If yes, note which ones: You can open the door with te combination, and you have to look the key
of the shelter at the noc
5.3 Are there any other local regulations, which will effect the installation
on this site? Yes ✘ Node verificación
Casilla N/Ade verificación
Casilla 664
Casilla de664
verificación
If yes, note which ones: Have to notificate to NOC
5.4 Other:
6 Site Access
6.1 Are there any special site accessibility requirements that need
to be considered? Yes Node✘ verificación
Casilla N/Ade verificación
Casilla 664
Casilla de 664
verificación
If yes, note which ones:
6.4 Do the visitors need to register and/or obtain working pass? Yes Node✘ verificación
Casilla N/A
Casilla Casilla de664
de verificación
664 verificación
If yes, note location of security office / Fire Command Center:
6.5 Are there any working hours restrictions? Yes Node✘ verificación
Casilla N/A
Casilla Casilla de664
de verificación
664 verificación
If yes, note allowed working hours:
6.6 Are there any other site access restrictions? *) Yes Node✘ verificación
Casilla N/A
Casilla de verificación
664
Casilla de664
verificación
If yes, note what:
6.7 Is use of GPS receiver instrument allowed at the site? Yes ✘ Casilla
Node verificación
N/A
Casilla Casilla de664
de verificación
664 verificación
Which are the geographical coordinates for the site? 18.511290° -72.289520°
6.8 Other:
4 (42)
7.1 Are the roads to the site suitable for material transportation and
working vehicles? *) Yes ✘ Node verificación
Casilla N/A
Casilla Casilla de664
de verificación
664 verificación
Is there any risk for leakage or flooding in the room? Yes Node✘ verificación
Casilla N/Ade verificación
Casilla 664
Casilla de664
verificación
Is the room fire protected? Yes Node✘ verificación
Casilla N/Ade verificación
Casilla 664
Casilla de664
verificación
Can the room be locked? Yes ✘ Node verificación
Casilla N/Ade verificación
Casilla 664
Casilla de664
verificación
1 Equipment Information
Fill in the type of equipment to be installed and data for the equipment in the table below:
2 Site Requirements
2.3 Power consumption: Needs two breacker to 8 amp for the new equipment AMM6P
2.4 Grounding requirements : The site needs one grounding bar to 0,50 mts x 0,10 mts on the tower to
ground of the new equipment to install, needs 10 meters of ground cable to conect the new equipment
with the proposal grounding bar
3.2 Note the route description to the equipment location area: You have to install the new equipment to 8 mts
at the tower existing
Are there any existing external alarms installed? Yes Node✘ verificación
Casilla N/A
Casilla de verificación
664Casilla de664
verific
If yes, which type of alarms?
3.4 Make a sketch of the equipment location area incl. any existing equipment on the Aerial Placing
Sketch.
Take all necessary measurements and note them on the Aerial Placing Sketch.
At extension and if existing Aerial Placing Information is used as basis, check and verify the
information on the drawing.
Select a location for the equipment to be installed and draw it on the Aerial Placing Sketch/Aerial
Placing Information.
Note all necessary installation measurements.
3.5 Other: The especifications are in the photo report, You can see this to more information.
✘ Casilla de verificación
Casilla de verificación
664Casilla de664
verific
7 (42)
4.6 Other:
5.1 Will an optical interface link be connected to the equipment? Yes Node verificación
Casilla N/A
Casilla de verificación
664
✘ Casilla de664
verific
5.2 Other:
6 Grounding
6.2 Mark the existing ground electrode on the Aerial Placing Sketch. At extension and if existing
Aerial Placing Information is used as basis, check and verify the information on the drawing.
Note all necessary installation measurements.
The especifications are in the photo report, You can see this to more information.
6.3 Other:
8 (42)
7 Transmission
7.1 Is there an existing outdoor cabinet for the transmission equipment? Yes ✘ Casilla
Node verificación
N/A
Casilla de verificación
664Casilla de664
verific
If yes, note following:
Outdoor cabinet type including standard for mounting brackets: Unknnow
Available depth for the equipment in the cabinet: 1 x 0,6
Available height for the equipment in the cabinet: 2,20 mts
Make a sketch of the space assigned in the outdoor cabinet for the transmission equipment in
the Equipment Allocation Sketch.
The especifications are in the photo report, You can see this to more information.
8 Distribution Frames (DFs)
8.2 Make a DF allocation sketch in the Equipment Allocation Sketch for each concerned DF type,
if this shall be documented.
8.3 Other:
9 (42)
9 Cable Routes
9.1 Are there any existing cable routes, which can be used? Yes ✘ Node verificación
Casilla N/A
Casilla de verificación
664Casilla de664
verific
If yes, note following:
Type: Ladder Dimensions: 0,40 x 9 mts
Available space:
9.3 Draw the cable routes on the Aerial Placing Sketch. At extension and if existing Aerial Placing
Information is used as basis, check and verify the information on the drawing.
Note all necessary installation measurements.
The especifications are in the photo report, You can see this to more information.
9.4 Other:
Type of site cables (power, traffic, external alarms, grounding, etc.) Required length (m)
Radio Cable 25 mts
Grounding Cable 10 mts
10.3 Other:
### Other
Take pictures to back up the notes, if allowed.
Fill in information about the pictures in the Picture Overview List
10 (42)
EXISTING MW NEW MW
Antenna 0.6, 15 GHz 0.6, 15 GHz
Number of antennas 1 1
Antenna Azimuth (Deg) 315 315
Antenna Elevation (Deg) Unknow Unknow
Antenna module type (GHz) 15 15
Antenna diameter (m) 0.6 0.6
Antenna height (m a g l) 8.9 8.3
Antenna Polarization V V
Antenna Mounting Minilink Support Minilink Support Existing
Waveguide length (m) 18 25
Antenna support type (mast) 2" diameter and 1 meter long 2" diameter and 1 meter long
Radio
Radio unit type Microwave ODU RAU ERICSSON
Radio unit sub-band 14795 - 15215 14795 - 15215
Number of radio units 1 1
Power Splitter
Type Asymmetric
Mounting type
Waveguide length (m)
Radio cable
Radio cable length (m) 18 25
19 (42)
1 Antenna Information
Fill in the type of antenna products to be installed and data for the antenna products
in table below:
2 Site Requirements
2.5 Other:
20 (42)
3.2 Note the route description to the antenna placement area: The new antenna is going to be instal
on the existing tower
Does a new antenna support structure need to be supplied? Yes Node✘ verificación
Casilla N/A
Casilla de verificación
664
Casilla de664
verific
Qty Dimensions
Guyed mast on ground
Self-supported tower on ground
Other structure on ground:
Qty Dimensions
Other:
3.4 Make a sketch of the antenna placement area including any existing equipment and existing or
new antenna support structure on the Aerial Placing Sketch.
Take all necessary measurements and note them on the Aerial Placing Sketch. At extension
and if existing Aerial Placing Information is used as basis, check and verify the information on
the drawing.
The especifications are in the photo report, You can see this to more information.
3.5 Mark type of antenna support necessary:
Qty Dimensions Weight
Tubes
Beams
Other:
3.6 Is use of GPS receiver instrument allowed at the site? Yes ✘ Node verificación
Casilla N/Ade verificación
Casilla 664
Casilla de664
verific
3.7 Which are the geographical coordinates for the antenna system? 18.511290° -72.289520°
Or if applicable, specify geographical coordinates for each antenna in the table below:
3.9 Check the compass direction towards a fixed construction e.g. the building and note it on
the Aerial Placing Sketch/Aerial Placing Information.
3.10 Establish suitable antenna locations and mark them on the Aerial Placing Sketch/Aerial Placing
Information.
Note all necessary installation measurements.
3.11 Are there any possible obstacles in the antenna directions? Yes Node✘ verificación
Casilla N/A
Casilla de verificación
664
Casilla de664
verific
If yes, make a note in the Protractor Sketch.
3.12 Other: The especifications are in the photo report, You can see this to more information.
23 (42)
4.1 Are there any existing feeder cable routes, which can be used? Yes ✘ Node verificación
Casilla N/A
Casilla de verificación
664
Casilla de664
verific
If yes, note following:
Type: Ladder Dimensions: 0,20 x 0,19
Available space:
4.2 Do new feeder cable routes need to be installed? Yes ✘ Node verificación
Casilla N/A
Casilla de verificación
664
Casilla de664
verific
If yes, note following:
Type: Dimensions:
4.3 Draw the feeder cable routes on the Aerial Placing Sketch. At extension and if existing Aerial
Placing Information is used as basis, check and verify the information on the drawing.
Note all necessary installation measurements.
The especifications are in the photo report, You can see this to more information.
4.4 NOTE! Calculate required feeder lengths and fill in site dependent feeder cables data
4.5 Indicate the location of the equipment room/outdoor cabinet on the Aerial Placing Sketch.
At extension and if existing Aerial Placing Information is used as basis, check and verify the
information on the drawing.
4.6 Other: The especifications are in the photo report, You can see this to more information.
5 Grounding
5.3 Mark the existing ground electrode, bonding bar and lightning conductor on the Aerial Placing Sketch.
At extension and if existing Aerial Placing Information is used as basis, check and verify
the information on the drawing
Note all necessary installation measurements.
5.4 Other: The especifications are in the photo report, You can see this to more information.
24 (42)
6.3 Other:
25 (42)
7 Other
Sketch (Protractor)
Comments: (e.g. obstacles seen from site within a radius of Casilla de100-500m
verificaciónor
664 1-5
Casilla dekm)
verificación 664
27 (42)
ame height of microwave antenna, the others two are up the microwave antenna
1 Equipment Information
Fill in the type of equipment to be installed and data for the equipment in the table below:
2 Site Requirements
2.2 Power requirements: Minilink TN needs to install two breakers of -48vdc and 8 Amp.
2.3 Power consumption: Needs two breacker to 8 amp for the new equipment AMM6P
2.5 Grounding requirements: You can use the existing grounding bar, you have to use 10 meters of grounding cable
2.6 Environment requirements: Operational temperature -50°C to+60°C (Outdoor full functionality)
Operational temperature -25°C to+55°C (Indoor full functionality)
2.8 Other:
34 (42)
3.2 Note the route description to the equipment room: The equipment is going to be install insite the
existing outdoor equipments
Will painting of walls, floor and/or ceiling be necessary? Yes Node✘ verificación
Casilla N/A
Casilla de verificación
664
Casilla de664
verificación
If yes, note where:
Are there any windows that might have to be covered? Yes Node verificación
Casilla N/A
Casilla de verificación
✘664
Casilla de664
verificación
Are there power outlets for tools? Yes No ✘ N/A
Casilla de verificación
Casilla de verificación
664
Casilla de664
verificación
Is there sufficient lighting? Yes Node verificación
Casilla N/A
Casilla de verificación
✘664
Casilla de664
verificación
Is the room tidy and clean? Yes Node verificación
Casilla N/A
Casilla de verificación
✘664
Casilla de664
verificación
If no, what needs to be taken care of?
Are there any existing external alarms installed? Yes Node✘ verificación
Casilla N/A
Casilla de verificación
664
Casilla de664
verificación
If yes, which type of alarms?
3.4 Make a sketch of the equipment room including any existing equipment on the Floor Plan Sketch.
Take all necessary measurements including ceiling height and note them on the Floor Plan Sketch.
At extension and if existing Floor Plan Drawing is used as basis, check and verify the information
on the drawing.
Select a location for the equipment to be installed and draw it on the Floor Plan Sketch/Floor
Plan Drawing.
Note all necessary installation measurements including installation height above floor level
if applicable.
3.5 Other: The especifications are in the photo report, You can see this to more information.
35 (42)
4.2 Are the AC-mains provided with Over Voltage Protection (OVP)? Yes Node verificación
Casilla N/A
Casilla de verificación
✘664
Casilla de664
verificación
If yes indicate type of OVP:
4.7 Other: The especifications are in the photo report, You can see this to more information.
36 (42)
5.1 Will an optical interface link be connected to the equipment? Yes Node verificación
Casilla N/A
Casilla de verificación
✘664
Casilla de664
verificación
5.2 Other:
6 Grounding
6.2 Is there an existing Main Earth Terminal (MET) in the equipment room,
which can be used? Yes ✘ Node verificación
Casilla N/A
Casilla de verificación
664
Casilla de664
verificación
If yes, note following:
Free positions: 5
Terminal screw dimensions: 0,40 x 0,10 mts
6.3 Mark the MET on the Floor Plan Sketch. At extension and if existing Floor Plan Drawing
is used as a basis, check and verify the information on the drawing.
Note all necessary installation measurements including installation height above floor level.
The especifications are in the photo report, You can see this to more information.
6.4 Other:
7 Transmission
7.1 Is there an existing rack/cabinet for the transmission equipment? Yes ✘ Casilla
Node verificación
N/A
Casilla de verificación
664
Casilla de664
verificación
If yes, note following:
Rack/cabinet type: no label
Rack/cabinet hole pattern:
Available depth for the equipment in the rack/cabinet: 1 x 0,60 mts
Available height for the equipment in the rack/cabinet: 1,70 mts
Make a sketch of the space assigned in the rack/cabinet for the transmission equipment in
the Equipment Allocation Sketch.
Make sure to include the transmission rack/cabinet on the Floor Plan Sketch.
7.2 Other: The especifications are in the photo report, You can see this to more information.
37 (42)
8.2 Make a DF allocation sketch in the Equipment Allocation Sketch for each concerned DF type,
if this shall be documented.
8.3 Other:
Is there a priority diagram for the equipment at the site? Yes Node verificación
Casilla N/A
Casilla de verificación
664
Casilla de664
verificación
9 Other: The especifications are in the photo report, You can see this to more information.
38 (42)
10.1 Are there any existing cable inlets, which can be used? Yes Node verificación
Casilla N/A
Casilla de verificación
✘664
Casilla de664
verificación
If yes, note following:
Dimensions: Inlet height:
Available cable glands:
10.3 Draw the cable inlets on the Floor Plan Sketch. At extension and if existing Floor Plan
Drawing/Cable Way Drawing is used as basis, check and verify the information on the drawing.
Note all necessary installation measurements including installation height above floor level.
The especifications are in the photo report, You can see this to more information.
10.4 Are there any existing cable routes, which can be used? Yes ✘ Casilla
Node verificación
N/A
Casilla de verificación
664
Casilla de664
verificación
If yes, note following:
Type: Ladder Height: 0,40 mts
Dimensions: 0,40 x 3 mts Available space: Enough
10.6 Draw the cable routes on the Floor Plan Sketch. At extension and if existing Floor Plan
Drawing/Cable Way Drawing is used as a basis, check and verify the information on the drawing.
Note all necessary installation measurements including installation height above floor level.
The especifications are in the photo report, You can see this to more information.
10.7 Other:
39 (42)
Type of site cables (power, traffic, external alarms, grounding, etc.) Required length (m)
Power DC ###
Grounding Cable ###
UTP cable 5
11.3 Other:
40 (42)