You are on page 1of 2

Check of shear capacity of footing as concrete

beam using edge distance as depth


2
3.14 ⋅ ((12 mm))
do ≔ 210 mm bv ≔ 1200 mm Ast ≔ ―――――― ⋅ 2 = ⎛⎝2.261 ⋅ 10 -4⎞⎠ m 2
4
⎛ 1⎞
β1 ≔ 1.1 ⋅ ⎜1.6 - do ⋅ ―⎟ = 1.529
⎝ m⎠ f'c ≔ 25 MPa
β2 ≔ 1 β3 ≔ 1

1

3 2
⎛ Ast ⋅ f'c ⎞ ―
3
Vuc ≔ β1 ⋅ β2 ⋅ β3 ⋅ bv ⋅ do ⋅ ⎜――― ⎟ ⋅ MPa = 108.661 kN
⎝ bv ⋅ do ⎠

Mz ≔ 13.2 kN ⋅ m

Mz
V ≔ ――――+ 7.6 kN = 106.6 kN
2
―⋅ 200 mm
3

V
―― = 0.981
Vuc

Footing check

Overturning:

Movr ≔ Mz + 7.6 kN ⋅ 300 mm + 5.2 kN ⋅ ((0.25 m)) = 16.78 kN ⋅ m

kN 1.9 m
Mr ≔ 0.9 ⋅ 1.9 m ⋅ 1.4 m ⋅ 0.3 m ⋅ 25 ―― ⋅ ――― = 17.057 kN ⋅ m
m3 2

⎛ kN ⎞
Vrslid ≔ 0.5 ⋅ ⎜1.9 m ⋅ 1.4 m ⋅ 0.3 m ⋅ 25 ―― ⎟ = 9.975 kN
⎝ m3 ⎠
Movr
e ≔ ―――――――――― = 0.841 m
kN
1.9 m ⋅ 1.4 m ⋅ 0.3 m ⋅ 25 ――
m3
⎛ 1.9 m ⎞
X ≔ 3 ⋅ ⎜――― - e⎟ = 0.327 m
⎝ 2 ⎠

⎛ kN ⎞
2 ⋅ ⎜1.9 m ⋅ 1.4 m ⋅ 0.3 m ⋅ 25 ―― ⎟
⎝ m3 ⎠
――――――――――― = 87.238 kPa
1.4 m ⋅ X