You are on page 1of 9

CLIENT CONTRACTOR

FIELD GATHERING SYSTEM


TRUNKLINES DETAILED ENGINEERING
STRUCTURAL CALCULATIONS FOR SAFETY WALL AND GRIFFIN ENERGY LTD. /
OMV (YEMEN BLOCK S2)
EXPLORATION GMBH MISC. COMPONENTS ZEN CHEMTECH / RISK WRITERS

Project Code: 03 Doc. No. YS2-03-C10017-TL-CAL-C-003 Rev 0 Page 1 of 32

STRUCTURAL CALCULATIONS FOR SAFETY WALL AND


MISCELLNEOUS COMPONENTS

0 8th March 2022 Issued for Design PPH GP MK

APPR. BY
REV DATE REVISION DESCRIPTION PRPD. BY CHKD. BY APPR. BY
CLIENT
1) Geometry

Safety Wall

A A

Plan View

Brick wall 2- 230 mm


1.5 m
460 X 230 mm Concrete Bond

Brick wall 1 -460 mm


1.5 m
Concrete Slab

Concrete Pedestal
1m
Concrete Footing

100 mm thick PCC Layer

Section A-A

1) Density of brick = 18 kN/m3


2) Density of concrete = 25 kN/m3
3) Thickness of brick wall 1 = 0.46 m
4) Thickness of brick wall 2 = 0.23 m
5) Height of brick wall 1 = 1.5 m
6) Height of brick wall 2 = 1.5 m
7) Width of pedestal (B) = 0.46 m
8) Height of pedestal (H) = 1 m
2) Weight Calculations
Calculations are for 1 m length

a) Weight of brick wall = (0.460 x 1.5+0.230*1.5) *1 * 18


= 18.63 kN

b) Weight of pedestal = 0.45 x 1 x 1 x 25


= 11.5 kN

c) Seismic Load = 0.0315 W


= 0.587 kN

3) Loading on Pedestal

Vertically Downward Weight = 30.13 kN


Moment on Pedestal = 0.880 kN-m
Shear Force = 0.587 kN

Design Forces
Vertically Downward Weight = 42.18 kN
Moment on Pedestal = 1.23 kN-m
Shear Force = 0.82 kN
Design of Pedestal
Design moment Mz = 1.232 kN-m
Design shear Vu = 0.822 kN

Please follow below design calculations


Width : bw = 460 mm

Depth : Db = 1000 mm

Concrete clear cover : c= 50 mm

Reinforcement : db = 12 mm

n= 10 nos
2
Ast = 1131.0 mm

Factored Moment acting on the section : Mu = 1.2 kN-m

Factored shear force acting on the section : Vu = 0.8 kN

2 Material Properties:
Concrete compressive strength f'c = 25 MPa

Reinforcement yield strength fy = 500 MPa

Stress block factor


b1 = If f'c < 28 MPa , b1 = 0.85
If 28MPa < f'c <55 Mpa , b1 = 0.85 - 0.05 x [(f'c -28MPa)/7Mpa]
If f'c>55 Mpa, b1 =0.65
b1 = 0.871429
The tension reinforcement ratio is given by

r = Ast/bw x d = 0.0026

Rn = r x fy x (1- 0.5 x r x fy/0.85 x f'c) = 1.262

Mn = Rn x bw x d2 = 517.46 kN-m

f= (Flexure) 0.9

f x Mn = Moment capacity = 465.72 kN-m

>Mu, Hence ok

3 Horizontal Reinforcement :

sqrt(fc')
Minimum steel ratio, ρmin = = 0.00250
4 fy

Provide 12 mm dia. Bars @ 100 mm C/C.

Provided Area = 1130.4 mm2

As,V
Actual steel ratio, ρactual = = 0.00260
bd1

Actual steel ratio > minimum, okay


460 mm

# 12 @ 100 mm C/C

1000 mm

Cross -Section Of pedestal


PROJECT DOCUMENT. NO. DATE

CLINET REVISION

CLAUSE NO. DESIGN CALCULATIONS Reference of ACI 318

DESIGN OF FOOTING
FACTOR = 1
DESIGN OF FOOTING FOR FOUNDATION F4
P= 42.18 kN
Mz= 1.23 kNm
Hx = 0.82 kN
Mx= 0.00 kNm
Hz = 0.00 kN

P= 42.18 kN
Mz= 1.23 kNm
Z
NGL Hx = 0.82 kN S

Hz = 0.00 kN

Mx= 0.00 kNm


(D-d) D L
X l X

b Z
d
R Q
B
B
Design Checks

The design checks for the following parametrs have been carried out and presented
i) Bearing pressure under the pad
ii) Requirement of reinforcement for the pad for flexure
iii) Check for One way and Punching shear

Basic Data

Grade of Concrete = M25


2
Chara. Yeild Strength of Reinforcement = 500 N/mm
Clear Cover to Footing Slab = 50.0 mm
Clear Cover to Pedestal = 50.0 mm

Soil Data:
Type of soil in foundation = HARD STRATA

Recommended Net Safe Bearing


= 100 kN/m2
Capacity of soil foundation

Foundation Size Chosen


Size of column

Breadth b = 0.460 m
Length l = 1.000 m
Size of Foundation Pad

Breadth B = 0.800 m
Length L = 1.000 m
Depth of the Pad d = 0.200 m
Total depth of foundation from GL D = 1.000 m

DESIGN:
Load data:

Vertical downward load (Unfactored load) V = 42.2 kN


Max.Moment at PL About Z-Z (Unfactored load) Mzz = 1.2 kNm
Max. Hori. Shear at PL in x direction (Unfactored load) Hx = 0.8 kN
Max. Moment at PL About X-X (Unfactored load) Mxx = 0.0 kNm
Max. Hori. Shear at PL in y direction (Unfactored load) Hz = 0.0 kN

Check for Base Pressure:

3
Volume of foundation concrete = 0.53 m
Weight of concrete = 13.2 kN
Downward load (maximum) = 42.2 kN
Weight of soil = 5.2 kN
Total downward load W = 60.5 kN

Max moment at base Mzz = 1.64 kNm


Max moment at base Mxx = 0.000 kNm
eccentricity ez = Mzz/W = 0.027 m
ez/B = 0.034
eccentricity ex = Mxx/W = 0.000 m
ex/L = 0.000
IF "ex<=(B/6) & ey<=(L/6)"

W  6ex 6ey 
Maximum Soil Pressure at Point Q "qmax" = X 1 + + 
BL  B L 
2
= 91.1 kN/m
2
< 100 kN/m
HENCE SAFE
Design of Foundation Pad (About Z-Z)

V M
d

d/2 d/2

B
53.9 kN/m2

84.6 kN/m2
R B C D E Q
PRESSURE DISTRIBUTION DIAGRAM

Pressure at point C = 78.1 kN/m2


Overhang distance x = 0.170 m
Depth of Pad d = 200 mm
Therefore, effective depth deff = 150 mm

Critical section for moment will be at the face of the column

Factored Bending Moment at face of column (1.4 load safety factor)


= 1.67 kNm/m
Pressure at Point E = 83.83 kN/m2
SF at a distance d from pedestal V = 1.68 kN
Factored SF (1.4 load safety factor) VU = 2.36 kN

Please follow below design calculations


Width : bw = 800.000 mm

Depth : Db = 1000.0 mm

Concrete clear cover


c =: 50 mm

Reinforcement : db = 12 mm

Spacing 200 mm
2
Ast = 565.2 mm

Factored Moment acting on the section : Mu = 1.67 kN-m

Factored shear force acting on the section : Vu = 2.36 kN

2 Material Properties:
f'c strength
Concrete compressive = 25 MPa
Reinforcement yieldfystrength
= 500 MPa

Stress block factor


b1 = If f'c < 28 MPa , b1 = 0.85
If 28MPa < f'c <55 Mpa , b 1 = 0.85 - 0.05 x [(f'c -28MPa)/7Mpa]
If f'c>55 Mpa, b 1 =0.65
b1 = 0.9

The tension reinforcement ratio is given by


r = Ast/bw x0.0007
d=
Rn = r x fy x (1- 0.5 x 0.371
r x fy/0.85 x f'c) =
2
Mn = Rn x bw x d = 264.43 kN-m
f = (Flexure) 0.9
f x Mn = Moment capacity
237.98= kN-m

>Mu, Hence ok

3 Check for Shear :


l (normal weight concrete) = 1
= 0.17 x l x f'c
0.5
Concrete ShearVcstrength x bw x d =641.9

f= (Shear) 0.8

f x Vc = Shear capacity = 481.44 kN


> 2.36 kN SAFE

Maximum shear stress= 0.25(fck)0.5 tc = 1.25 N/mm2


Pressure at Point B = 57.50 kN/m2
Pressure at Point D = 80.95 kN/m2
Punching shear V = 6.818663 kN
Factored shear force VU = 10.22799 kN
Punching shear stress tp = 0.02 N/mm2
< 1.25 HENCE OK

So, provide # 12 mm @ 200 mm C/C bars for footing and #12 @ 150 mm C/C bars for slab