You are on page 1of 24

GNSS-UT @ KM45.

943 - BARREL UNDER EARTH BANK


STAAD RESULTS

DRY WET
CONDITION BOX EMPTY BOX FULL

MEMBER END TOP END BOT END VER MID VER END TOP END BOT END VER MID VET
MOMENT SUPPORT 4.313 4.648 4.313 0 4.304 4.518 4.304 0
CENTRE 4.96 5.169 3.644 0 4.969 5.094 3.683 0
SUPPORT 4.313 4.648 4.648 0 4.304 4.518 4.518 0

SF SUPPORT 14.836 15.707 2.384 0 14.836 15.38 2.245 0


CENTRE 0 0 0 0 0 0 0 0
SUPPORT 14.836 15.707 3.19 0 14.836 15.38 2.609 0
Axial force 2.384 0 14.836 0 2.245 0 14.836 0
@ c/c + @ c/c
DESIGN OF TOP MEMBER

DRY WET

BENDING MOMENT AT 'A' = 4.313 t-m 4.304 t-m


BENDING MOMENT AT 'B' = 4.313 t-m 4.304 t-m
BENDING MOMENT AT 'C' = 4.96 t-m 4.969 t-m

SHEAR FORCE AT 'A' = 14.836 t 14.836 t


SHEAR FORCE AT 'B' = 14.836 t 14.836 t

AXIAL FORCE = 2.384 t 2.245 t

LENGTH OF MEMBER = 2.500 m 2.5 m


THICKNESS OF MEMBER = 350 mm 350 mm
CLEAR COVER = 40 mm 40 mm
DIA.OF MAIN REINFORCEMENT = 16 mm 16 mm

DIA.OF DIST.REINFORCEMENT = 10 mm 10 mm

GRADE OF CONCRETE = M 30 M 30

AT SUPPORT :
OPTION 1 OR 2 = 1 1
t = 1300 kg/cm² 1300 kg/cm²
j = 0.861 0.861
Q = 17.985 17.985

AT CENTRE :
OPTION 1 OR 2 = 1 1
t = 1300 kg/cm² 1300 kg/cm²
j = 0.861 0.861
Q = 17.985 17.985

A B
DRY A
4.313 4.313

C
4.96
2.5

A B
WET A
4.30 4.30

C
4.969
2.5
AT SUPPORT :

END SUPPORT

MAX. DESIGN MOMENT ( DRY ) = 4.313 t-m


MAX. AXIAL FORCE = 2.384 t
EFFECTIVE DEPTH = 302 mm

MOMENT DUE TO AXIAL FORCE = C*X

X = ( 302 - 0.5 x 350


= 127 mm.

MOMENT DUE TO AXIAL FORCE = 0.303 t-m

RESULTANT MOMENT ( M + C X ) = 4.616 t-m

MAX. DESIGN MOMENT ( WET ) = 4.304 t-m


MAX. AXIAL FORCE = 2.245 t
EFFECTIVE DEPTH = 302 mm

MOMENT DUE TO AXIAL FORCE = C*X

MOMENT DUE TO AXIAL FORCE = 0.285 t-m

RESULTANT MOMENT ( M + C X ) = 4.589 t-m

EFFECTIVE DEPTH REQUIRED = 4.616 x 1E5


17.985 x 100

= 16.02 cm. < 30.2

AREA OF STEEL AT END SUPPORT = 4.616 x 1 E 5


t x j x 30.2
( t = 1300 j = 0.861 )
= 13.65 cm²
Ast provided = 16 @ 100 c/c + 0 @ 100 c/c = 20.106 cm2

MID SUPPORT

MAX. DESIGN MOMENT ( DRY ) = 4.313 t-m


MOMENT DUE TO AXIAL FORCE = 0.303 t-m

RESULTANT MOMENT ( M + C X ) = 4.616 t-m

MAX. DESIGN MOMENT ( WET ) = 4.304 t-m


MOMENT DUE TO AXIAL FORCE = 0.285 t-m

RESULTANT MOMENT ( M + C X ) = 4.589 t-m

EFFECTIVE DEPTH REQUIRED = 4.616 x 1E5


17.985 x 100

= 16.02 cm. < 30.2

AREA OF STEEL AT MID SUPPORT = 4.616 x 1 E 5


t x j x 30.2
( t = 1300 j = 0.861 )
= 13.65 cm²

REQUIRED STEEL AT SUPPORT ( I.e., at Top ) = 13.65 cm²

Ast provided = 16 @ 100 c/c + 0 @ 100 c/c = 20.106 cm2


c/c
AT CENTRE :

MAX. DESIGN MOMENT ( DRY ) = 4.96 t-m


MOMENT DUE TO AXIAL FORCE = 0.303 t-m

RESULTANT MOMENT ( M + C X ) = 5.263 t-m

MAX. DESIGN MOMENT ( WET ) = 4.969 t-m


MOMENT DUE TO AXIAL FORCE = 0.285 t-m

RESULTANT MOMENT ( M + C X ) = 5.254 t-m

EFFECTIVE DEPTH REQUIRED = 5.254 x 1E5


17.985 x 100

= 17.11 cm. < 30.2

AREA OF STEEL = 5.254 x 1 E 5


t x j x 30.2
( t = 1300 j = 0.861 )
= 15.54 cm²
Ast provided = 16 @ 100 c/c + 0 @ 100 c/c = 20.106 cm2

DISTRIBUTION STEEL:

MINIMUM STEEL= 0.350 % (AS PER CL.8.1 OF IS 3370 PART II-2009)

MINIMUM STEEL= 0.350 %

MINIMUM STEEL ( 0.350 * 350 /2 )*100 / 1000

= 6.125 cm²

ON EACH FACE= 6.125 cm²

AREA OF STEEL= 6.125 cm²

PROVIDE 10 DIA @ 100 C/C ( Ast = 7.86 cm² )


SHEAR:

CRITICAL SECTION FOR SHEAR IS AT 'd' FROM THE FACE OF THE SUPPORT

d = ( 302 + 350 / 2 ) / 1000

d = 0.477 m

( i ) DRY CONDITION 14.836


9.175

0.773 0.477

1.250
14.836

2.5

MAX. SHEAR FORCE AT CRITICAL SECTION = 9.175 t

( ii ) WET CONDITION 14.84


9.175

0.773 0.477

1.250
14.84

2.5

MAX. SHEAR FORCE AT CRITICAL SECTION = 9.175 t

MAXIMUM SHEAR FORCE = 9.175 t

SHEAR STRESS= 9.175 * 1000 / ( 100 * 30.2 ) = 3.04 Kg/cm2

Ast provided = 20.106 cm2

100*As/b*d = 100 * 20.106 / ( 100 * 30.2 ) = 0.666 %

FROM TABLE 23 OF IS 456:2000

PERMISSIBLE SHEAR STRESS FOR THE ABOVE 100*As/b*d = 4.099 Kg/cm2

HENCE, NO SHEAR REINFORCEMENT IS REQUIRED


DESIGN OF BOTTOM MEMBER

DRY WET

BENDING MOMENT AT 'A' = 4.648 t-m 4.518 t-m


BENDING MOMENT AT 'B' = 4.648 t-m 4.518 t-m
BENDING MOMENT AT 'C' = 5.169 t-m 5.094 t-m

SHEAR FORCE AT 'A' = 15.707 t 15.380 t


SHEAR FORCE AT 'B' = 15.707 t 15.38 t

AXIAL FORCE = 0t 0t

LENGTH OF MEMBER = 2.500 m 2.500 m


THICKNESS OF MEMBER = 350 mm 350 mm
CLEAR COVER = 40 mm 40 mm
DIA.OF MAIN REINFORCEMENT = 16 mm 16 mm

DIA.OF DIST.REINFORCEMENT = 10 mm 10 mm

GRADE OF CONCRETE = M 30 M 30

AT SUPPORT :
OPTION 1 OR 2 = 1 1
t = 1300 kg/cm² 1300 kg/cm²
j = 0.861 0.861
Q = 17.985 17.985

AT CENTRE :
OPTION 1 OR 2 = 1 1
t = 1300 kg/cm² 1300 kg/cm²
j = 0.861 0.861
Q = 17.985 17.985

A B
DRY A
4.648 4.648

C
5.169
2.5

A B
WET A
4.52 4.52

C
5.094
2.5
AT SUPPORT :

END SUPPORT

MAX. DESIGN MOMENT ( DRY ) = 4.648 t-m


MAX. AXIAL FORCE = 0t
EFFECTIVE DEPTH = 302 mm

MOMENT DUE TO AXIAL FORCE = C*X

X = ( 302 - 0.5 x 350 )


= 127 mm.

MOMENT DUE TO AXIAL FORCE = 0.000 t-m

RESULTANT MOMENT ( M + C X ) = 4.648 t-m

MAX. DESIGN MOMENT ( WET ) = 4.518 t-m


MAX. AXIAL FORCE = 0t
EFFECTIVE DEPTH = 302 mm

MOMENT DUE TO AXIAL FORCE = C*X

MOMENT DUE TO AXIAL FORCE = 0.000 t-m

RESULTANT MOMENT ( M + C X ) = 4.518 t-m

EFFECTIVE DEPTH REQUIRED = 4.648 x 1E5


17.985 x 100

= 16.08 cm. < 30.2 cm.

AREA OF STEEL AT END SUPPORT = 4.648 x 1 E 5


t x j x 30.2
( t = 1300 j = 0.861 )
= 13.75 cm²
Ast provided = 16 @ 100 c/c + 0 @ 100 c/c = 20.106 cm2

MID SUPPORT

MAX. DESIGN MOMENT ( DRY ) = 4.648 t-m


MOMENT DUE TO AXIAL FORCE = 0.000 t-m

RESULTANT MOMENT ( M + C X ) = 4.648 t-m

MAX. DESIGN MOMENT ( WET ) = 4.518 t-m


MOMENT DUE TO AXIAL FORCE = 0.000 t-m

RESULTANT MOMENT ( M + C X ) = 4.518 t-m

EFFECTIVE DEPTH REQUIRED = 4.648 x 1E5


17.985 x 100

= 16.08 cm. < 30.2 cm.

AREA OF STEEL AT MID SUPPORT = 4.648 x 1 E 5


t x j x 30.2
( t = 1300 j = 0.861 )
= 13.75 cm²

REQUIRED STEEL AT SUPPORT ( I.e., at Top ) = 13.75 cm²


Ast provided = 16 @ 100 c/c + 0 @ 100 c/c = 20.106 cm2
c/c
AT CENTRE :

MAX. DESIGN MOMENT ( DRY ) = 5.169 t-m


MOMENT DUE TO AXIAL FORCE = 0.000 t-m

RESULTANT MOMENT ( M + C X ) = 5.169 t-m

MAX. DESIGN MOMENT ( WET ) = 5.094 t-m


MOMENT DUE TO AXIAL FORCE = 0.000 t-m

RESULTANT MOMENT ( M + C X ) = 5.094 t-m

EFFECTIVE DEPTH REQUIRED = 5.094 x 1E5


17.985 x 100

= 16.95 cm. < 30.2 cm.

AREA OF STEEL = 5.094 x 1 E 5


t x j x 30.2
( t = 1300 j = 0.861 )
= 15.07 cm²
Ast provided = 16 @ 100 c/c + 0 @ 100 c/c = 20.106 cm2

DISTRIBUTION STEEL:

MINIMUM STEEL= 0.350 % (AS PER CL.8.1 OF IS 3370 PART II-2009)

MINIMUM STEEL= 0.350 %

MINIMUM STEEL ( 0.350 * 350 /2 )*100 / 1000

= 6.125 cm²

ON EACH FACE= 6.125 cm²

AREA OF STEEL= 6.125 cm²

PROVIDE 10 DIA @ 100 C/C ( Ast = 7.86 cm² )


SHEAR:

CRITICAL SECTION FOR SHEAR IS AT 'd' FROM THE FACE OF THE SUPPORT

d = ( 302 + 350 / 2 ) / 1000

d = 0.477 m

( i ) DRY CONDITION 15.707


9.713

0.773 0.477

1.250
15.707

2.5

MAX. SHEAR FORCE AT CRITICAL SECTION = 9.713 t

( ii ) WET CONDITION 15.38


9.511

0.773 0.477

1.250
15.38

2.5

MAX. SHEAR FORCE AT CRITICAL SECTION = 9.511 t

MAXIMUM SHEAR FORCE = 9.713 t

SHEAR STRESS= 9.713 * 1000 / ( 100 * 30.2 ) = 3.22 Kg/cm2

Ast provided = 20.106 cm2

100*As/b*d = 100 * 20.11 / ( 100 * 30.2 ) = 0.666 %

FROM TABLE 23 OF IS 456:2000

PERMISSIBLE SHEAR STRESS FOR THE ABOVE 100*As/b*d = 4.099 Kg/cm2

HENCE, NO SHEAR REINFORCEMENT IS REQUIRED


DESIGN OF END VERTICAL MEMBER

DRY WET

BENDING MOMENT AT 'A' = 4.313 t-m 4.304 t-m


BENDING MOMENT AT 'B' = 4.648 t-m 4.518 t-m
BENDING MOMENT AT 'C' = 3.644 t-m 3.683 t-m

SHEAR FORCE AT 'A' = 2.384 t-m 2.245 t-m


SHEAR FORCE AT 'B' = 3.19 t-m 2.609 t-m

AXIAL FORCE = 14.836 t 14.836 t

LENGTH OF MEMBER = 1.2 m 1.2 m


THICKNESS OF MEMBER = 350 mm 350 mm
CLEAR COVER = 40 mm 40 mm
DIA.OF REINFORCEMENT = 16 mm 16 mm

DIA.OF REINFORCEMENT = 10 mm 10 mm

GRADE OF CONCRETE = M 30 M 30

OPTION 1 = IN CONTACT WITH WATER


OPTION 2 = AWAY FROM WATER

AT SUPPORT :
OPTION 1 OR 2 = 1 1

t = 1300 kg/cm² 1300 kg/cm²


j = 0.861 0.861
Q = 17.985 17.985

AT CENTRE :
OPTION 1 OR 2 = 1 1

t = 1300 kg/cm² 1300 kg/cm²


j = 0.861 0.861
Q = 17.985 17.985

DRY WET

4.313 A 4.30 A

3.644 C 3.68 C

B B
4.648 4.52
( i ) DRY CONDITION

MAX. DESIGN MOMENT = 4.648 t-m

DIRECT STRESS ( cc,cal ) = 14.836 / 1.0 * 0.35

= 42.389 t/m²

cc = 10 N/mm²
= 1000 t/m²

STRESS DUE TO BENDING= M/Z WHERE Z = b*d2/6

Z = 0.0204

cbc,cal = 4.648 / 0.0204

= 227.657

cbc PERMISSIBLE = 750

cc,cal + cbc,cal < 1


cc cbc

42.389 + 227.657
1000 750

0.0424 + 0.3035 = 0.346 < 1

( ii ) WET CONDITION

MAX. DESIGN MOMENT = 4.52 t-m

DIRECT STRESS ( cc,cal ) = 14.84 / 1.0 * 0.35

= 42.389 t/m²

cc = 10 N/mm²
= 1000 t/m²

STRESS DUE TO BENDING= M/Z WHERE Z = b*d2/6

Z = 0.0204

cbc,cal = 4.52 / 0.0204

= 221.290

cbc PERMISSIBLE = 750

cc,cal + cbc,cal < 1


cc cbc

42.389 + 221.290
1000 750

0.0424 + 0.2951 = 0.337 < 1


TOP SUPPORT :

MAX. DESIGN MOMENT ( DRY ) = 4.313 t-m


MAX. AXIAL FORCE = 14.84 t
EFFECTIVE DEPTH = 302 mm

MOMENT DUE TO AXIAL FORCE = C*X

X = ( 302 - 0.5 x 350 )


= 127 mm.

MOMENT DUE TO AXIAL FORCE = 1.884 t-m

RESULTANT MOMENT ( M + C X ) = 6.197 t-m

MAX. DESIGN MOMENT ( WET ) = 4.304 t-m


MAX. AXIAL FORCE = 14.84 t
EFFECTIVE DEPTH = 302 mm

MOMENT DUE TO AXIAL FORCE = C*X

X = ( 302 - 0.5 x 0 )
= 127 mm.

MOMENT DUE TO AXIAL FORCE = 1.884 t-m

RESULTANT MOMENT ( M + C X ) = 6.188 t-m

EFFECTIVE DEPTH REQUIRED = 6.197 x 1E5


17.985 x 100

= 18.56 cm. < 30.2 cm.

AREA OF STEEL = 6.197 x 1 E 5


t x j x 30.2
( t = 1300 j = 0.861 )
= 18.33 cm²
Ast provided = 16 @ 100 c/c + 0 @ 230 c/c = 20.106 cm2

BOTTOM SUPPORT :

MAX. DESIGN MOMENT ( DRY ) = 4.648 t-m


MAX. AXIAL FORCE = 14.84 t
EFFECTIVE DEPTH = 302 mm

MOMENT DUE TO AXIAL FORCE = 1.884 t-m

RESULTANT MOMENT ( M + C X ) = 6.532 t-m

MAX. DESIGN MOMENT ( WET ) = 4.518 t-m


MAX. AXIAL FORCE = 14.84 t
EFFECTIVE DEPTH = 302 mm

MOMENT DUE TO AXIAL FORCE = 1.884 t-m

RESULTANT MOMENT ( M + C X ) = 6.402 t-m

EFFECTIVE DEPTH REQUIRED = 6.532 x 1E5


17.985 x 100

= 19.06 cm. < 30.2 cm.

AREA OF STEEL = 6.532 x 1 E 5


t x j x 30.2
( t = 1300 j = 0.861 )
= 19.32 cm²
REQUIRED STEEL AT SUPPORTS = 19.32 cm²

Ast provided = 16 @ 100 c/c + 0 @ 230 c/c = 20.106 cm2


c/c
AT CENTRE :

MAX. DESIGN MOMENT ( DRY ) = 3.644 t-m


MAX. AXIAL FORCE = 14.84 t
EFFECTIVE DEPTH = 302 mm

MOMENT DUE TO AXIAL FORCE = 1.884 t-m

RESULTANT MOMENT ( M + C X ) = 5.528 t-m

MAX. DESIGN MOMENT ( WET ) = 3.683 t-m


MAX. AXIAL FORCE = 14.84 t
EFFECTIVE DEPTH = 302 mm

MOMENT DUE TO AXIAL FORCE = 1.884 t-m

RESULTANT MOMENT ( M + C X ) = 5.567 t-m

EFFECTIVE DEPTH REQUIRED = 5.567 x 1E5


17.985 x 100

= 17.53 cm. < 30.2 cm.

AREA OF STEEL = 5.567 x 1 E 5


t x j x 30.2
( t = 1300 j = 0.861 )
= 16.47 cm²

REQUIRED STEEL AT CENTRE = 16.47 cm²


Ast provided = 16 @ 100 c/c + 0 @ 230 c/c = 20.106 cm2
DISTRIBUTION STEEL:

MINIMUM STEEL= 0.350 % (AS PER CL.7.1 OF IS 3370 PART II-1965)

MINIMUM STEEL= 0.350 % ( CONSIDERING 100% )

MINIMUM STEEL ( 0.350 * 350 /2 )*100 / 1000

= 6.125 cm²

PROVIDE 10 DIA @ 100 C/C ( Ast = 7.86 cm² )


CHECK FOR SHEAR:-

CRITICAL SECTION FOR SHEAR IS AT 'd' FROM THE FACE OF THE SUPPORT

d = ( 302 + 350 / 2 ) / 1000

d = 0.477 m

3.19 2.61

0.477 0.477
0.974 0.680
0.687 0.645
0.210 0.168
1.2 1.2

2.384 2.25

MAX. SHEAR FORCE AT CRITICAL SECTION (DRY) = 0.974 t

MAX. SHEAR FORCE AT CRITICAL SECTION (WET) = 0.680 t

MAXIMUM SHEAR FORCE = 0.974 t

SHEAR STRESS= 0.974 * 1000 / ( 100 * 30.2 ) = 3.23 Kg/cm2

Ast provided = 16 100 0 230 = 20.106 cm2

100*As/b*d = 100 * 20.11 / ( 100 * 30.2 ) = 0.666 %

FROM TABLE 23 OF IS 456:2000

PERMISSIBLE SHEAR STRESS FOR THE ABOVE 100*As/b*d = 3.565 Kg/cm2

HENCE, NO SHEAR REINFORCEMENT IS REQUIRED


DESIGN OF END VERTICAL MEMBER

DRY WET

BENDING MOMENT AT 'A' = 0 t-m 0 t-m


BENDING MOMENT AT 'B' = 0 t-m 0 t-m
BENDING MOMENT AT 'C' = 0 t-m 0 t-m

SHEAR FORCE AT 'A' = 0 t-m 0 t-m


SHEAR FORCE AT 'B' = 0 t-m 0 t-m

AXIAL FORCE = 0.000 t 0t

LENGTH OF MEMBER = 1.2 m 1.2 m


THICKNESS OF MEMBER = 300 mm 300 mm
CLEAR COVER = 40 mm 40 mm
DIA.OF REINFORCEMENT = 16 mm 16 mm

DIA.OF REINFORCEMENT = 12 mm 12 mm

GRADE OF CONCRETE = M 30 M 30

OPTION 1 = IN CONTACT WITH WATER


OPTION 2 = AWAY FROM WATER

AT SUPPORT :
OPTION 1 OR 2 = 1 1

t = 1300 kg/cm² 1300 kg/cm²


j = 0.861 0.861
Q = 17.985 17.985

AT CENTRE :
OPTION 1 OR 2 = 1 1

t = 1300 kg/cm² 1300 kg/cm²


j = 0.861 0.861
Q = 17.985 17.985

DRY WET

0 A 0.00 A

0 C 0.00 C

B B
0 0.00
( i ) DRY CONDITION

MAX. DESIGN MOMENT = 0 t-m

DIRECT STRESS ( cc,cal ) = 0 / 1.0 * 0.3

= 0.000 t/m²

cc = 10 N/mm²
= 1000 t/m²

STRESS DUE TO BENDING= M/Z WHERE Z = b*d2/6

Z = 0.0150

cbc,cal = 0 / 0.0150

= 0.000

cbc PERMISSIBLE = 750

cc,cal + cbc,cal < 1


cc cbc

0.000 + 0.000
1000 750

0.0000 + 0.0000 = 0.000 < 1

( ii ) WET CONDITION

MAX. DESIGN MOMENT = 0.00 t-m

DIRECT STRESS ( cc,cal ) = 0.00 / 1.0 * 0.3

= 0.000 t/m²

cc = 10 N/mm²
= 1000 t/m²

STRESS DUE TO BENDING= M/Z WHERE Z = b*d2/6

Z = 0.0150

cbc,cal = 0.00 / 0.0150

= 0.000

cbc PERMISSIBLE = 750

cc,cal + cbc,cal < 1


cc cbc

0.000 + 0.000
1000 750

0.0000 + 0.0000 = 0.000 < 1


TOP SUPPORT :

MAX. DESIGN MOMENT ( DRY ) = 0 t-m


MAX. AXIAL FORCE = 0.000 t
EFFECTIVE DEPTH = 252 mm

MOMENT DUE TO AXIAL FORCE = C*X

X = ( 252 - 0.5 x 300 )


= 102 mm.

MOMENT DUE TO AXIAL FORCE = 0.000 t-m

RESULTANT MOMENT ( M + C X ) = 0.000 t-m

MAX. DESIGN MOMENT ( WET ) = 0 t-m


MAX. AXIAL FORCE = 0.00 t
EFFECTIVE DEPTH = 252 mm

MOMENT DUE TO AXIAL FORCE = C*X

X = ( 252 - 0.5 x 0 )
= 102 mm.

MOMENT DUE TO AXIAL FORCE = 0.000 t-m

RESULTANT MOMENT ( M + C X ) = 0.000 t-m

EFFECTIVE DEPTH REQUIRED = 0.000 x 1E5


17.985 x 100

= 0.00 cm. < 25.2 cm.

AREA OF STEEL = 0.000 x 1 E 5


t x j x 25.2
( t = 1300 j = 0.861 )
= 0.00 cm²
Ast provided = 18 @ 200 c/c + 0 @ 200 c/c = 12.723 cm2

BOTTOM SUPPORT :

MAX. DESIGN MOMENT ( DRY ) = 0 t-m


MAX. AXIAL FORCE = 0.00 t
EFFECTIVE DEPTH = 252 mm

MOMENT DUE TO AXIAL FORCE = 0.000 t-m

RESULTANT MOMENT ( M + C X ) = 0.000 t-m

MAX. DESIGN MOMENT ( WET ) = 0.000 t-m


MAX. AXIAL FORCE = 0.00 t
EFFECTIVE DEPTH = 252 mm

MOMENT DUE TO AXIAL FORCE = 0.000 t-m

RESULTANT MOMENT ( M + C X ) = 0.000 t-m

EFFECTIVE DEPTH REQUIRED = 0.000 x 1E5


17.985 x 100

= 0.00 cm. < 25.2 cm.


AREA OF STEEL = 0.000 x 1 E 5
t x j x 25.2
( t = 1300 j = 0.861 )
= 0.00 cm²

REQUIRED STEEL AT SUPPORTS = 0.00 cm²

Ast provided = 18 @ 200 c/c + 0 @ 200 c/c = 12.723 cm2


AT CENTRE :

MAX. DESIGN MOMENT ( DRY ) = 0 t-m


MAX. AXIAL FORCE = 0.00 t
EFFECTIVE DEPTH = 252 mm

MOMENT DUE TO AXIAL FORCE = 0.000 t-m

RESULTANT MOMENT ( M + C X ) = 0.000 t-m

MAX. DESIGN MOMENT ( WET ) = 0 t-m


MAX. AXIAL FORCE = 0.00 t
EFFECTIVE DEPTH = 252 mm

MOMENT DUE TO AXIAL FORCE = 0.000 t-m

RESULTANT MOMENT ( M + C X ) = 0.000 t-m

EFFECTIVE DEPTH REQUIRED = 0.000 x 1E5


17.985 x 100

= 0.00 cm. < 25.2 cm.

AREA OF STEEL = 0.000 x 1 E 5


t x j x 25.2
( t = 1300 j = 0.861 )
= 0.00 cm²

REQUIRED STEEL AT CENTRE = 0.00 cm²


Ast provided = 18 @ 200 c/c + 0 @ 200 c/c = 12.723 cm2
DISTRIBUTION STEEL:

MINIMUM STEEL= 0.350 % (AS PER CL.7.1 OF IS 3370 PART II-1965)

MINIMUM STEEL= 0.350 % ( CONSIDERING 100% )

MINIMUM STEEL ( 0.350 * 300 /2 )*100 / 1000

= 5.250 cm²

PROVIDE 12 DIA @ 200 C/C ( Ast = 5.66 cm² )


CHECK FOR SHEAR:-

CRITICAL SECTION FOR SHEAR IS AT 'd' FROM THE FACE OF THE SUPPORT

d = ( 252 + 300 / 2 ) / 1000


@ c/c + @ c/c
d = 0.402 m

0 0.00

0.402 0.402
#DIV/0! ###
#DIV/0! #DIV/0!
#DIV/0! #DIV/0!
1.2 1.2

0 0.00

MAX. SHEAR FORCE AT CRITICAL SECTION (DRY) = #DIV/0! t

MAX. SHEAR FORCE AT CRITICAL SECTION (WET) = #DIV/0! t

MAXIMUM SHEAR FORCE = #DIV/0! t

SHEAR STRESS= #DIV/0! * 1000 / ( 100 * 25.2 ) = #DIV/0! Kg/cm2

Ast provided = 18 200 0 200 = 12.723 cm2

100*As/b*d = 100 * 12.72 / ( 100 * 25.2 ) = 0.505 %

FROM TABLE 23 OF IS 456:2000

PERMISSIBLE SHEAR STRESS FOR THE ABOVE 100*As/b*d = 3.000 Kg/cm2

#DIV/0!
UNDER EARTH

13.65 #REF! 13.65 #REF! #REF! #REF! #REF! #REF! #REF! 13.65 #REF! 13.65
19.32 19.32
#REF! #REF! #REF!

16.47 #REF! #REF! #REF! 16.47

#REF! #REF! #REF!


19.32 19.32
#REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF!