SUMMARY OF PRICE SCHEDULE COST

CONSTRUCTION OF FIRE STATION AND RESIDENTIAL QUARTERS


AT ASLALI, AHMEDABD.

Sr. Total Quoted Amount


Items
No. Rs.

A CIVIL WORK 45,641,329.90

B ELECTRICAL WORK 6,370,681.00

TOTAL 52,012,010.90

I/We am/are willing to carry out work at % above/below (should be written in figures and words)
the estimated amount mentioned above. Amount of my/our tender works out as under

Estimated Amount put to tender Rs.5,20,12,010.90 Estimated Amount put to tender Rs. 5,20,12,010.90
Add % above Rs Deduct % below Rs
Total Rs Net Rs
In words In words

Signature of Contractor
City Engineer
Date
AMC

Page 1 Summary Sheet


BILL OF QUANTITIES FOR FIRE STATION AT ASLALI, AHMEDABAD.
Item
Description Quantity Unit Rate Rs. Amount Rs.
No.

(1) (2) (3) (4) (5) (6)


Excavation and Filling Work
1 Excavation in all sorts of Hard Soil including soft
murram, for any activity but not limited for,
foundation of wall, columns, Ground beams, raft,
ducts, pipe trenches, U.G. Tank, Compound walls,
steps, drains and all other miscellaneous
excavation etc. as per specifications including
shoring shuttering, bailing out surface water,
pumping of water, including backfilling in all types
foundation trenches, compacting and consolidating
etc complete, rate includes conveyance charges of
remaining surplus earth from site as directed with
the any lead in the city as directed by Clerk-of-
Work.

Up to 1.5 Mt. Depth 2495.00 cum 106.50 265,717.50

From 1.5 Mt to 3.0 Mt depth 761.00 cum 111.42 84,790.62

From 3.0 Mt to 5.0 Mt depth 360.00 cum 116.02 41,767.20

Filling

2 Filling in plinth with sand under floors including


watering, ramming, consolidating and dressing etc.
complete. 556.00 cum 220.00 122,320.00

Cement Concrete Work


3 Providing and laying Plain cement concrete 1:4:8
(1 cement : 4 coarse sand : 8 hand broken stone
aggregate 40mm nominal size) and curing
complete excluding cost of formwork in foundation
and plinth 647.00 cum 1689.00 1,092,783.00

Reinforced Cement Concrete Work


4 Providing and laying controlled cement concrete M-
250 and curing complete including cost of
formwork and excluding the cost of reinforcement
for reinforced concrete work in:

(A) Foundations, footings, base of columns, and


mass concrete. 84.00 Cu.M. 4007.00 336,588.00
(B) Walls from top of foundations/level up to floor
two level. 201.00 Cu.M. 4484.00 901,284.00
(C) Slabs, landing shelves, Balconies, lintels,
beams, girders, and cantilever, up to floor two
level. 365.00 Cu.M. 4676.00 1,706,740.00

5 Providing and laying controlled cement concrete


M-
200 work and curring etc.complete including cost
of formwork but excluding the cost reinforcement
for reinforced concrete workat all levels in

Item
Description Quantity Unit Rate Rs. Amount Rs.
No.

Page 2 Abstract Sheet


(1) (2) (3) (4) (5) (6)
RCC Walls 224.00 cum 4112.00 921,088.00
RCC beams 869.00 cum 3974.00 3,453,406.00
RCC slabs 749.68 cum 3974.00 2,979,228.32
RCC Columns 151.00 cum 4278.00 645,978.00
Staircase 61.00 cum 4365.00 266,265.00
6 Charges for making holes in RCC walls
Diameter of holes from 300 to 1500 mm clear and
above 12.00 No. 6000.00 72,000.00

Reinforcement Steel Work


7 Provindig Thermo Mechanically Treated bars (TMT
BARS) confirming to IS 1786/Fe 415 for R.c.c
Works includings brndings, binding and placing in
position complete. 280575.00 Kg 36.50 10,240,987.50

Brick Masonary
8 Brick work using common burnt clay building
bricks having crushing strength not less than 35
kg/sq.cm in cement mortar 1:5 (1Cement : 5 fine
sand) -

A in foundation upto plinth 71.00 cum 1479.00 105,009.00

9 Brick work using burnt clay building bricks for


conventional brickwork having crushing strength
not less than 35 kg/sq.cm in cement mortar 1:5
(1Cement : 5 fine sand) -
B for all levels in super structure 565.00 cum 1556.00 879,140.00
10 Half Brick work using burnt clay conventional
building bricks for exposed brick work having
crushing strength not less than 35 kg/sq.cm in
cement mortar 1:4 (1Cement : 4 coarse sand)
-
B for all levels 4406.00 Sq.Mt. 280.00 1,233,680.00
-
WATER PROOFING
11 Providing and laying integral cement based water
proofing treatment avrage120 mm thick including
preparation of surface as required for treatment of
roof,balconies,terraces and making necessary vata
at the junction of Wall and floor wherever required
as directed by Engineer In Charge and consisting
of following operation .For Payment only Flat Area
Considered.Including ten years performance of
guarantee bond to be given.

1644.00 Sq.Mt. 400.00 657,600.00


Applying and grouting a slurry coat of neat cement
using 2.75 kg/Sq.Mt. Of cement admixed with
proprietary water proofing compound conforming to
IS .2645 over tha RCC slab including cleaning the
surface before treatment.
-

Item
Description Quantity Unit Rate Rs. Amount Rs.
No.

(1) (2) (3) (4) (5) (6)

Page 3 Abstract Sheet


Laying cement concrete using broken
bricks/brickbats25 mm to 100 mm size with 50% of
cement mortar 1:5 ( 1 cement , 5 coarse
sand)admixed with proprietary water proofing
compound conforming to IS 2645 over 20 mm thick
layer of cement mortar of mix 1:5 (1
-
After two days of proper curing applying a second
coat of cement slurry admixed with proprietary
water proofing compound confirming to IS 2645
-
Finishing the surface with 20 mm thick jointles
cement mortar mix 1:4 ( 1 cement, 4 coarse sand)
admixed with proprietary water proofing compound
conforming to IS: 2645 and finally finishing the
surface with trowel with neat cement slurry and
making of -
The whole terrace so finished shall be flooded with
water for a minimum period of two weeks for curing
and for final test.all above operations to be done in
order and as directed and specified by Engineer -
In- charge -
12 Providing, Filling cinder or any such similar light
weight material at any lead incl. watering
consolidating etc.complete as per direction of
engineer incharge. 798.00 Cu.M. 375.00 299,250.00
-
Wood work and joinery
13 Providing and fixing 35 mm th. Shutters for doors
windows & clearstory windows incl. wood frames
as specified 10 cm. x 7cm. size incl. Indian teak
wood frames 10 cm to 7 cm. size incl. anodised
alluminium fixtures and fastenings including primer
coat of approved quality and two coats of oil paint
etc. complete.
-
B Fully panelled 234.00 Sq.Mt. 3338.00 781,092.00
C Partly panelled partly glazed 73.00 Sq.Mt. 3121.00 227,833.00
14 Providing and fixing flush door shutters soild
coreconstruction with frame of firstclass hard wood
with cross band & face veneer or plywood face
panels etc. incl. Anodised alluminium butt hinges
with necessary screws,
-
(B) Non decorative type & block board core
anodised alluminium butt hinges ib flush door
shutters -
35mm thick 14.00 Sq.Mt. 1569.00 21,966.00
15 providing and fixing glazed louverd glass window
and ventilator with teak wood frame 10 cm x 7 cm.
Size incl. 3 coats of oil painting to wood work etc.
complete. 461.00 Sq.Mt. 2473.00 1,140,053.00
-

Item
Description Quantity Unit Rate Rs. Amount Rs.
No.

(1) (2) (3) (4) (5) (6)


Steel, Aluminium and Iron Works

Page 4 Abstract Sheet


16 providing and fixing M.S. flats to wooden/aluminium
frames of windows etc. with M.S. flats if requierd at
required spacing and frame alround square and
nuts or by screws
-
(a) plain grill 420.00 K.g. 50.00 21,000.00
-
17 Providing and Fixing 30 mm th. Approved standed
brand factory made PVC rigid foam panaled door
shutter manufactured by made from Ms tube 19
Gauge th. Size 19X 9 mm for styles and 15 X 15
mm top & bottom rail covered with heat molded
PVC C chanal of 5mm thick sheet and 30 X 50 mm
wide to foam styles and 5 mm th. and 75 mm PVC
sheet for top rail, rock rail and bottom rail on ethier
side and 5 mm th., 20 mm wide cross PVC sheet
as gape insert for top rail and bottom rail, paneling
of 5 mm th. PVC sheet filled in the MS frame
welded/ shield to the styles and rails manufacture
applications and directions of engineer in charge
fixed to frames with three nos stainless steel
hinges (four inch long) incl. medium grade
hardeware all octroi, tax charges etc. complete.
(Approved rate)

48.00 Sq. M. 2213.00 106,224.00


18 Providing and Fixing Approved standed brand
factory made PVC door frame size 50 X 47 mm
with a wall th. 5mm made out of extruded 5 mm
rigid pvc foam sheet mitered at corners as jointed
with 2 no. of 150 mm long brackets of 15 X 15
M.S. square tube the vertical door profiles to be
reinforced with 19 X 9 mm M.S. square tube of 19
Gauge, EPDM rubber gasket weather seal seal to
be provided through out the frame. The door frame
to be fixed to the wall using M.S. screws of 65/100
mm size etc. complete as per manufacturers
specifications and direction of engineering in chare
incl. medium grade aluminum hardware all all
octroi, tax charges etc. complete.(Approved rate)

95.00 Rmt 301.00 28,595.00

19 Providing & fixing in position collaspsible steel


shutter with vertical channels of 20x10x2 mm
braced with flat iron diagonals of 20x5mm size with
top and bottom rails of T iron 40 x 40 x 6mm with
38 mm Dia. Steel pulleys complete with bolts, nuts,
locking arrangement, stoppers, handles, including
applying a priming coat of red lead paint.
9.00 Sq.Mt. 2575.00 23,175.00

Item
Description Quantity Unit Rate Rs. Amount Rs.
No.

(1) (2) (3) (4) (5) (6)


Paving and floor finishes

Page 5 Abstract Sheet


20 Providing and laying white glazed tiles 6mm thick
in flooring , treads of steps & landing laid on a bed
of 12 mm tk. Cement mortar1:3 (1Cement :
3coarse sand) and flush pointing in white cement
slurry 539.00 Sq.Mt. 649.00 349,811.00
21 Providing & laying 10 mm thick vitrified tiles with a
size 600 mm X 600 mm in flooring, treads of steps
and landing on a bed of 12mm thk. Cement mortar
1:3 (1 cement:3 coarse sand finished with flush
pointing in approved coloured cement Slurry)
780.00 Sq.Mt. 1345.00 1,049,100.00
22 Providing & laying polished kota stone slab of
various sizes ,miror polished flooring over
20mm(avg.) thk. Base of cement mortar 1:6(1
cement: 6 coarse sand) laid over and jointed with
grey cement slurry incl. Rubbing and polishing etc.
complete.
25mm thick 1867.00 Sq.Mt. 713.00 1,331,171.00
23 Providing & laying polished kota stone slab 25 mm
thk. In skirtings, window sills, planter top and risers
of steps on 10mm(avg.) thk. Base of cement
mortar 1:3(1 cement: 3 coarse sand) laid over and
jointed with grey cement slurry incl. Rubbing and
polishing etc. complete.
20.00 Sq.Mt. 739.00 14,780.00
24 Providing and laying white glazed tiles 6 mm tk. In
skirting, risers of steps and dedo on 10 mm th.
Cement plaster 1:3 ( 1 cement : 3 coarse sand ) &
jointed with white cement slurry etc. complete
681.00 Sq.Mt. 656.00 446,736.00
25 Providingand laying China mosaic flooring using
broken pieces of white and coloured glazed tiles
as per design including bedding in cement mortar
1 : 6 (1 cement : 6 coarse sand) and white
cement pointing complete

1150.00 Sq.Mt. 220.00 253,000.00


26 providing & laying cement cocrete flooring 1:2:4
laid in one layer finished with a floating coat of
neat 880.00 Sq.Mt. 182.00 160,160.00
cement(50 MM Thck)
27 Providing & laying rough kota stone slab of various
sizes flooring over 20mm(avg.) thk. Base of
cement mortar 1:6(1 cement: 6 coarse sand) laid
over and jointed with grey cement slurry incl.
Rubbing and polishing etc. complete.
104.00 Sq.Mt. 555.00 57,720.00
28 Provoding and laying precast concerete paver
block flooring with 90mm thk. M-60 strength and
colur precast concrete paver block of approved
make and colour in road & parking filling of joints,
making bed surface of min. 75 mm const. Sand
smooth etc. complete 817.00 Sq.Mt. 550.00 449,350.00
29 providing & laying Mosaic tiles flooring 20 to 25mm
thick over 20mm(avg.) base of cement
mortar1:6)under Pergo wooden flooring in
gymnasium. 300.00 Sq.Mt. 400.00 120,000.00

Item
Description Quantity Unit Rate Rs. Amount Rs.
No.

Page 6 Abstract Sheet


(1) (2) (3) (4) (5) (6)
30 Providing and fixing in floor ,Laminated flooring of
Armstrong, pergo or euivalent company. Colours
and design as approved by the architect in
Gymnasium Area. 300.00 Sq.Mt. 1030.00 309,000.00

White washings,colour washings distempring


and other finishes
31 Providing and appling 3 coats of white wash to all
surfaces as per Detailed specifications including
necessary scaffolding,scrapping etc. complete.if
additional coats are required to obtain uniform
finish the same shall be carried out at no extra
cost. as directed by the clerk- of- work.at alllift,
levels and leads.
32907.00 Sq.Mt. 3.10 102,011.70
32 Wall painting (two coats) with solvent based flat
paint of approve brand and manufacture on new
wall surface to give an even shade incl. Throughly
brushing the surface free from mortar droppings
and othere foreign matter and sand prepared
smooth etc. complete. 20.00 Sq.Mt. 41.60 832.00
33 Finishing wall with waterproofing cement paint of
on wall surface (two coats) to give an approved
brand and manufacture and of required shape
even shade after throughly brushing the surface to
remove all dirt and remains of loose powdered
materials. 208.00 Sq.Mt. 25.40 5,283.20

Painting and polishing


34 Painting two coats including priming coat on
external surfaces of rain water, soil, waste and vent
pipes & fittings with ready mixed bituminuous paint
brushing, black anti corrosive to give an even
shade incl. Cleaning of all dirt, dust and other
foreign matter.

(B) 75 mm dia 25.00 Rmt. 8.90 222.50


(C) 100 mm dia 250.00 Rmt. 11.10 2,775.00
35 Providing and applying two coat of Anti-funges and
Anti-moss Acrylic co polymer based exterior paint
including providing and apply one coat of primer
recommended by paint menufacturar on smooth
finished or sand-faced surfaces at all levels &
heights. With two or more coats (up to finish) of
approved make and shade on new work to give an
even shade. Rate includes cost of providing, and
erecting all necessary scaffolding,prepare &
cleaning the wall surfece, brushes, removal of the
same after completion of work, cleaning all
surfaces like floor, Door - Window etc Complete as
per directed by Clerk-Of-Work for all Lifts, level,
leads.NS.

2391.00 Sq.Mt. 87.00 208,017.00


36 Polishing with French polish on new wood-wood
base surface to give an even surface incl. Clening
the surface to all dirts, dust and sand papered
smooth & incl. A coat of wood filler.
25.00 Sq.Mt. 55.80 1,395.00

Page 7 Abstract Sheet


Item
Description Quantity Unit Rate Rs. Amount Rs.
No.

(1) (2) (3) (4) (5) (6)

Miscellaneous building items


37 Providing and fixing Sintex Water Tank of
approved capacity on prepared floor as directed
by engineer 15000.00 Ltrs 3.50 52,500.00
incharge at site.

38 Anti termite treatment as per IS 6313 dosages


and application procedures shall confirm to
manufractures instructions.
Providing and injecting Chemical emulsion with
Chloropirifos emulsifiable concentrate 1 % in
column pots, wall trenches,treatment to back fill
R.C.C walls and column top surface of plinth
filling,junction of wall and floor ,external perimeter
of building, over DPC ,under aprons and
foundations and other critical areas.Plinth area to
be measured. 10 years Guarantee to be given by
the agency
1286.00 Sq.Mt. 63.90 82,175.40
39 Providing and Fixing in Positions Slidinng M.S.
Gate As Per Size&Design complete with bolts,
nuts, locking arrangement, stoppers handles
including applying a priming coat of red lead paint.
1435.00 Kg 200.00 287,000.00
40 Providing & constructing 20 mm wide & full depth
Expansion joint including providing 20mm th
Expansion board ( Shalitex or equivelant brand )
painted with bitumen on both sides and filling the
joint with polysulphide sealent material (20mm x
30mm ) or equivalent, fixing M.S. Dowell bar
painted with bitumen upto full length & one
side 25mm pvc(1.5mm thick) rigid pipe with
plug as per the given detailed drawing and
Directed by Clerk- of-Work.etc complete for all
level and leads.
121.00 Rmt. 300.00 36,300.00

Page 8 Abstract Sheet


41 Providing & fixing of aluminium composite panel
supported on Aluminium Section Grid of size
38mm X 25mm weight 0.33 Kg per Rmt. of Jindal
section & Grid work supported to the wall by
means of M.S/Aluminium Clamps. Aluminium
Composite Panel of make
Alstrong/Aludecor/Timex/Inobond of
4.0 mm thick made out of two aluminium skin of
0.25 mm thick which are precoated and thermally
bonded to each side of non toxic polythelene core.
Adhesion achieved by combination of chemical &
mechanical actions there by provide exceptional
resistance to delamination. This aluminium
composite panel shall be fabricated in tray form &
fixed to the aluminium grid by aluminium cleats.
Gap between two trays shall be filled with 8 dia/10
dia backer road and top layer shall be covered by
Ultraproof of GE or 789 0f Dowcorning.alongwith
backing coat plaster of 15 mm th. in cement : 1 : 4
to obtain true line & plumb.(RA-15)

865.00 Sq.Mt. 3000.00 2,595,000.00

Item
Description Quantity Unit Rate Rs. Amount Rs.
No.

(1) (2) (3) (4) (5) (6)


DEMOLOTION & DISMANTING
42 Demolition and disposal of unserviceable materials
with all leads and lifts
(i) Lime concrete Cu.M 122.40 -
(II) Unreinforced cement concrete 10.00 Cu.M 1407.00 14,070.00
43 Demolition of brick work and stone masonry
including stacking of serviceable materials and
disposal of unserviceable materials with all leads
and lifts
(II) In cement mortar 100.00 Cu.M 127.30 12,730.00
44 Demolition of terrace incl. stacking of serviceable
materials and disposal of unservicable materialswith
all lead lift.
(I) Brick tile covering 10.00 Sq.M 14.80 148.00
45 Dismantling tiled or stone floors laid in mortar
including stacking of serviceable material and
disposal of uservicalble material with all lead and
lifts 100.00 Sq.M 11.20 1,120.00
46 Dismantling steel work including dismembering and
stacking the materials with all leads and lifts.
20.00 Kg. 0.90 18.00
47 The dismantling doors windows ventilatlation etc.
(wood or steel ) shutters including chowkhats
architraves hold fasts and other attachments etc.
complete and stacking them within all lead & lifts

(I) Not exceeding 3 Sq.M. in area 35.00 Sq.m 43.90 1,536.50


48 Dismantling santary, fitting, lime washbasin, W.C.
pan indian and eqropian type flushing tank etc..
Stacking the materials with all lead and lift.
10.00 Each 95.00 950.00

Page 9 Abstract Sheet


49 Scraping oil paint from steel and other metal
surface and making the surface even (with hand
scraping) 10.00 Sq.M 11.40 114.00

Page 10 Abstract Sheet


Item
Description Quantity Unit Rate Rs. Amount Rs.
No.

(1) (2) (3) (4) (5) (6)

Plaster and Pointing Wrok


50 Providing and laying, 20 mm thick double coat
“Mala” plaster to the Internal side of walls, Beams,
Columns, pardi , ceiling , chajja & RCC walls etc in
the proportion of cement mortar 1:4 for first coat
(12 mm thick) and cement mortar 1:2 for second
coat (8 mm thick) to all types and shapes of bricks,
stones or RCC surfaces at all respective levels in
line, level and plumb including normal straps,
grooves, drip moulds, embossed bands, jambs,
etc. complete and including roughening the
surfaces with necessary scaffolding, curing,
cleaning the floor after application, providing &
fixing chicken wire mesh of 24 gauge of 300 mm
width at the junction of brick work & RCC work
including fixing with nails, rawl plugs etc before
applying plaster as per drawing/instruction of Clerk-
Of-Work etc. complete. For all levels, hights and
leads of works.

32907.00 Sq.Mt. 135.00 4,442,445.00


51 Providing and laying, 20 mm thick double coat
“Mala” plaster OR "sand face(Tippani)" plaster to
the External side of walls, Beams, Columns, pardi
& RCC walls etc in the proportion of cement
mortar 1:4 for first coat (12 mm thick) and cement
mortar 1:2 for second coat (8 mm thick) to all types
and shapes of bricks, stones or RCC surfaces at all
respective levels in line, level and plumb including
normal straps, grooves, drip moulds, embossed
bands, jambs, etc. complete and including
roughening the surfaces with necessary
scaffolding, curing, cleaning the floor after
application, providing & fixing chicken wire mesh of
24 gauge of 300 mm width at the junction of brick
work & RCC work including fixing with nails, rawl
plugs etc before applying plaster as per
drawing/instruction of Clerk- Of-Work etc.
complete. For all levels, hights and leads of
works.No holes in wall will be permitted for
scaffolding. Only Double stage scaffloding is to be
used.

2391.00 Sq.Mt. 135.00 322,785.00

51 Providing and laying 20mm thick waterproof plaster


in two coats (12mm+8mm) in cement mortar (1:4)
mix with recommended waterproofing compound in
adequate quantity, all tools and tackels and
scaffolding, curing etc. complete.
461.10 Sq.Mt. 170.00 78,387.14

Page 11 Abstract Sheet


Item
Description Quantity Unit Rate Rs. Amount Rs.
No.

(1) (2) (3) (4) (5) (6)


Water supply,plumbing,drainage and sanitary
fittings:
52 Providing and fixing to wall ceiling and floor
galvanised mild steel tubes (medium grade) of the
following nominal bore tube fitting and clamps inc.
making good the wall,ceilling and floor .

50mm dia G.I. Pipe 9.00 Rmt 384.00 3,456.00


40mm dia G.I. Pipe 150.00 Rmt 283.00 42,450.00
25mm dia G.I. Pipe 200.00 Rmt 193.00 38,600.00
15mm dia G.I. Pipe 125.00 Rmt 112.00 14,000.00
53 providing and fixing cast iron spigot and socket
soil, waste and ventilating pipes of the following
nominal
size.
B. 75mm Dia. 150.00 Rmt 615.00 92,250.00
C. 100 mm Dia 200.00 Rmt 712.00 142,400.00
54 providing and fixing in position cowl vent to pipes

B. 75mm Dia. 12.00 no. 269.00 3,228.00


C. 100 mm Dia 12.00 no. 368.00 4,416.00
55 Providing and fixing 40mm dia. gun metal check or
non return full way wheel valve in pipeline of
approved quality etc. complete as directed by
Engineer Incharge. 5.00 Nos. 628.00 3,140.00
56 Providing and fixing 25mm dia. gun metal check or
non return full way wheel valve in pipeline of
approved quality etc. complete as directed by
Engineer Incharge. 3.00 Nos. 349.00 1,047.00
57 Providing and laying (two level or slopes) and
jointing with stiff mixture of cement mortar in
proportion 1:1 salt glazed stoneware pipes of
following internal diameters inc. testing of pipes
and joints etc. complete with necessary formwork
and curing complete.
150mm dia 90.00 Rmt 143.00 12,870.00
100mm dia 46.00 Rmt 104.00 4,784.00
58 Providing & fixing C.I.(spun) "Nanhi trap" of the
following nominal diameter of self cleaning design
with C.I.screwed down or hinged grating inc. Cost
of cutting and making good the walls and floors
100mm inlet and 50 mm outlet etc. complete as
directed by engineer in charge.
45.00 Nos. 252.00 11,340.00
59 Providing & fixing washdown type water closet
(Indian type) W.C. PAN size 580mm (earth work,
bed concreting., foot rests and trap to be measured
and paid for seperately.
A) Vitreous china pattern.
(1) Long pattebn white colour 4.00 Nos. 530.00 2,120.00

Page 12 Abstract Sheet


Item
Description Quantity Unit Rate Rs. Amount Rs.
No.

(1) (2) (3) (4) (5) (6)


60 Providing & fixing Wall-mounted European Closet
Suite P-Trap (White/Light Coloured) with Dual
Flush Tank , PVC pan connector, seat & lid (heavy
duty) including C.I. Brackets, C.P. brass hinges, All
Internal fittings complete with rubber buffers, C.P.
nuts, bolts, ChaKi, etc making holes in walls &
floors, & finishing for ready to use.The rate
includes Providing & fixing 15mm Angle Valve as
per product detail with braided hose pipe as per
product detail, including cutting and making good
the wall where required.( Ewc wall
hung-p(white/light coloured), or equivalent, Chair
bracket : equivalent brand make, rag bolts, Dual
Flush Cistern : equivalent, Angle cock: equivalent,
Braided hose as per Design)

38.00 Nos. 3500.00 133,000.00


61 Providing and fixing 100 mm size 'P' or 'S' trap
including jointing the trap with soil pipe in cement
mortar 1:1.
A) Vitreous china pattern. 45.00 Nos. 163.00 7,335.00
62 Providing & fixing wash basin with single hole for
piller tap with C.I. Or M.S. brackets painted white
incl cutting holes and making good the same but
excluding fitting.
(i) Viterious China
in white/colour washbasin 40.00 Nos. 814.60 32,584.00
63 Providing and fixing G.I.inlet connections for flush
pipe with W.c. Pan. 48.00 Nos. 19.70 945.60
64 Providing and fixing C.P. brass wste for wash basin
or sink. 28.00 Nos. 88.00 2,464.00
65 Providing & fixing 600 mm x 450 mm bevelled
edge mirror of superior glass mounted on 6mm
thick A.C.sheet or plywood sheet and fixed to
wooden plugs with C.P. brass screws and
washers. 36.00 Nos. 491.00 17,676.00
66 Providing and fixing 15mm dia. brass polished
bright screw down bib taps in pipeline of approved
quality etc. complete as directed by Engineer
Incharge 50.00 Nos. 135.00 6,750.00
67 Providing & fixing piller taps,capstan head screw
down high screw,shanks & back nuts.
20mm dia 28.00 Nos. 227.00 6,356.00
68 Providing & fixing chromium plated brass half turn
flush cock of approved quality incl. Fixing in pipe
line etc. complete.
(I) 20 mm dia 17.00 Nos. 320.00 5,440.00
(II) 25 mm dia 17.00 Nos. 349.00 5,933.00
(III) 32 mm dia 11.00 Nos. 378.00 4,158.00
69 Providing & fixing S.W. Gully trap with C.I grating
brick masonary chamber andd water tight C.I cover
with frame of 300mm x 300 mm size(inside) with
standard weight.(square mouth trap)

100 mm x 100mm size p-type 20.00 Nos. 809.00 16,180.00

Item
Description Quantity Unit Rate Rs. Amount Rs.
No.

Page 13 Abstract Sheet


(1) (2) (3) (4) (5) (6)
150mm x 100 mm size p or r type 15.00 Nos. 815.00 12,225.00

70 Providing and fixing Liquid shop desposer stand in


toilet area. 10.00 Nos. 125.00 1,250.00

71 Providing and Fixing Full height mirror


(1800x900mm) bevelled edge mirror of superior
glass mounted on 6mm thick A.C.sheet or plywood
sheet and fixed to wooden plugs with C.P. brass
screws and washers. in general toilet.
36.00 Nos. 750.00 27,000.00

72 Providing and laying to level and slopes and


jointing reinforced concrete non-pressure pipes I.S.
class NP 2 of the following internal diameter with
collars and butt ends prepared for collar joints
including testing of joints complete(24.22)SOR-
2008-2009
[B] 150mm 125.00 Metre 258.00 32,250.00
[C] 250mm 25.00 Metre 383.00 9,575.00
[D] 300mm 50.00 Metre 451.00 22,550.00

73 Construction manhole with R.C.C. top slab in 1:2:4


(1 cement :2 coarse sand :4 graded stone
aggregate 20mm nominal size) foundation
concrete 1;3:6 mix (1 cement : 3 coarse sand :6
brickbats 40-
50mm thick with cement mortar 1:5 (1 cement :5
coarse sand) finished with a floating coat of neat
cement and making channel in cement concrete
1:2:4 ( 1cement : 2 coarse sand : 4 Stone
aggregate
20 mm nominal size ) finished smooth complete
including curing and testing

(a) inside size 900mm x 1200 mm and 1.5m deep


including C.I. cover with frame size 650mm
diameter total weight of cover and frame to be not
less than 128kgs. (wt of cover 64kg. And wt. Of
frame 64kg.)
with 230mm thick wall of brick masonry using
bricks having crushing strength not less than 35
kg/sq.cm. In cement mortar 1:5 (1 cement : 5
coarse sand)
(ii) B type depth1.50 meter for 150mm diameter
sewer 12.00 No. 13479.00 161,748.00

74 (i) Extra rate for constructing B.B. masonry for


every additional depth of O.I.M. or part thereof over
item 24.27 [i] depth from 0.9m to 1.5m
(i) Extra rate for constructing B.B. masonry only for
every additional depth of 0.1m or part thereof over
item
(ii) for depth from 1.50 to 2.25m 12.00 No. 302.00 3,624.00
75 Providing and fixing cast iron steps of size 500mm
x 150mm x 22.5 and pointing with two coats
of 192.00 No. 109.00 20,928.00
anticorrosive paint etc. complete

Item
Description Quantity Unit Rate Rs. Amount Rs.
No.

Page 14 Abstract Sheet


(1) (2) (3) (4) (5) (6)
76 Providing & Fixing CI manhole cover
0.60mtX0.45mt size having weight not less than 35
KG. 12.00 No. 1058.00 12,696.00
External & Landscaping work

77 Supplying and fixing reinforced concrete heavy


duty non-pressure pipes of 300 mm dia with collars
for culverts carrying heavy traffic as per Indian
railway station specification including the setting
the pipes in C.M. 1:2 watering and laying ( to level
or slopes) of class NP3 of the following internal
diameters(RA- 20)
143.00 R.M 990.00 141,570.00
78 Providing supplying and fixing precast concrete
road side kerb block of 300 mm x300mm x100mm
as per the approved drawing and design cement
concrete precast block shall be cast from M-20
grade concrete the rate including necessary cutting
of asphalt road excavation in all types of soil and
metal etc.and removing the excavated stuff
complet rate also include filling the gap of curb with
sand consolidation etc. complte and levelled
including painting of joints with cement concrete in
cement mortart 1:2 and racking of joints as per
design etc. complte the rate shall including painting
of kerb with white washing of theee coats etc.
complte.(RA-22)

825.00 R.M 85.00 70,125.00


79 Providing & Laying vaccum dewatering flooring
method for RCC road with broom finish or with
power driven trowel finish surface of conc. The
conrete is 1:2:4 of 10cm thickness and 8 mm TMT
at 200 c/c(RA-24) 1825.00 Sq.m 550.00 1,003,750.00
80 Providing soak pit as per detailed drawing,
including excavating sand filling brick bats with dry
masonry work at top including covering the top with
stone including providing vatas in C.M. 1:3 with
finishing curing etc. complete as directed.
2.00 no. 100000 200,000.00
81 Constructing storm water chamber, including
excavating and sand filling, with bricks having
crushing strength not less than 35kg/cm2 in CM
1.5., including C.I. cover with grating, with frame
(light duty) 610 mm x 610mm internal dimensions
total weight of cover with frame to be not less than
38kg (wt. of cover 23kg. and wt. of frame 15kg)
foundation concrete 1:5:10 inside plaster 15mm
thick with cement mortar 1:3 finished smooth with a
floating coat of neat cement on walls and bed
concrete etc. complete

10.00 no. 6500.00 65,000.00


[a] Inside dimensions 610mm x 610mm and depth
up to 1200 mm

Item
Description Quantity Unit Rate Rs. Amount Rs.
No.

(1) (2) (3) (4) (5) (6)

Page 15 Abstract Sheet


82 Providing and constructing, Underground (U/G)
sump for rain water, of specified capacity, on
specified location, for all depths, in controlled CC of
M-200 grade with bottom slab, top slab and RCC
walls, including cost of form work and
reinforcement, with inside and outside plaster in
CM
1 :3 and water proofing treatment as per IWP
specification, including injection, grouting, etc.
complete. The rate includes for providing and fixing
specified nos. 0.6 m. x 0.6 m. size 35 Kg. CI
manhole cover/s at top, including wash out pipe
line and inlet and outlet connections etc. complete.

200000.00 litre 5.5 1,100,000.00


83 Constructing Septic Tank, 2.10m X 0.9m X 1.3m
liquid depth, as shown and mentioned in the
detailed plumbing drawings and structural
drawings. 2.00 no. 32000 64,000.00
84 Supplying and fixing Kirlosker or equivalent make
open well horizontal monoset submersible pump of
following specifications with suction and delivery of
50 mm or 65 mm dia of approved make with all
connections making foundation with suitable motor,
full automatic star-delta starter, complete panel,
ammeter, voltmeter, etc., dry running and single
phasing prevention devices, etc. complete.

2.00 no. 17500 35,000.00

(A) Approx. 1.5 H.P., 300 lpm at 30 mt head


85 Providing and fixing, 15 mm. dia. GI hydrant, for
gardening, at required distance, with 25 mm. dia.
wheel valve / ball valve of approved make, as
recommended or equivalent and GI pipe piece to
provide the hydrant, 300 mm. above dressed
ground level, including excavation, making
connections with main lines, specials, if required
etc. complete, as directed.
5.00 no. 758 3,790.00

86 Borewell work
1 Drilling by rotary mud flush method in all type of
alluvial soil, the drilling shall be done by mud flush
rotary equipment and stores to be provided by the
contractor. Bore shall be round and shall stand
unceased for at least 72 hours.

a 180 mt depth & 350 mm dia 180.00 Rmt 432.00 77,760.00

2 LOWERING OF PIPES
Pipes shall be lowered in such a manner as not to
damage either the pipes or mud wall of the bore if
pipes are dropped or mud wall damaged casing
heading of sand then cost of bore shall be
recovered from contractor
a 150 mm dia ERW pipe 4.70 mm thick ISI make
180.00 Rmt 1700.00 306,000.00

Item
Description Quantity Unit Rate Rs. Amount Rs.
No.

(1) (2) (3) (4) (5) (6)

Page 16 Abstract Sheet


Pipes shall be lowered in such a manner as not to
damage either the pipes or mud wall of the bore if
pipes are dropped or mud wall damaged casing
heading of sand then cost of bore shall be
recovered from contractor.
A 50 mm upvc dia column pipe of heavy quality as
per 150.00 Rmt 240.00 36,000.00
IsI requirement & of approved quality

4 Labour for cutting of slot on pipes. 35.00 Rmt 150.00 5,250.00


i) 63 mm x 5.7 mm x 4.7 mm as per ISI 8100 -

5 A) CEMENT SEALING : 1.00 Unit 12000.00 12,000.00


Cement sealing shall be provided in the annual
space between the wall of naked bore hole & outer
surface of piping to prevent saline water from
upped acquire to lower acquire by gravel packing
etc. cement sealing shall be done with cement
slurry (including cost of cement) injected by mud
pump through air line pipe at desired depth of
about 20 feet and sounding of gravel should be
taken perfectly.

6 GRAVEL PACKING : 10.00 Cmt 1550.00 15,500.00


Gravel packing shall be done slowly and slowly,
gravel should be from hard rock durable and
uniform in size duly screed by mechanical vibrator.
Gravel packing should be continue till filter is
constructed around the pipes so as to see that no
sand flow into the wall under operational condition
of the well.

7 DEVELOPMENT : 3.00 hr 5900.00 17,700.00

A) The development of bore by air compressor


should be done in such a way that each water
bearing zone is developed in deaning order
separate by compressed air pumping etc. a
discharging shall be sand free.

8 Electrical logging and water analysis for selection


of water bearing zone and its possibility.
1.00 Job 13900.00 13,900.00

9 Cost of providing and fixing ball plug wall,cap. MS


clamps chappals etc 1.00 Job 12300.00 12,300.00

10 Providing & fixing KSB make 12.5 H.P. & 16 stage


Submersible Pump & Accessaries 1.00 Nos 42000.00 42,000.00

11 Providing & fixing 2.5 sqmm cable of finolex make


150.00 Rmt 84.00 12,600.00

Item
Description Quantity Unit Rate Rs. Amount Rs.
No.

(1) (2) (3) (4) (5) (6)


12 Providing & fixing pump pannel of standard make
with necessary cables 1.00 Nos 11000.00 11,000.00

Page 17 Abstract Sheet


87 Rain harvesting work
1 Excavation for foundation upto 1.5M depth
including sorting out and stacking of useful
materials and disposing of the excavated stuff up
to 50 meter lead.
Loose or soft soil 64.00 cum 38.60 2,470.40
Dense or hard Soil 0.00 cum 49.40 -
2 Excavation for foundation for depth from 1.5 mt. to
3.0 mt. including sorting out and stacking of useful
materials and disposing of the excavated stuff up
to 50 meter lead.
Loose or soft soil 23.00 cum 42.80 984.40
Dense or hard Soil 0.00 cum 53.60 -
3 Excavation for foundation for depth from 3.0 mt. to
5.0 mt. including sorting out and stacking of useful
materials and disposing of the excavated stuff up
to 50 meter lead.
Loose or soft soil 33.00 cum 47.00 1,551.00
Dense or hard Soil 0.00 cum 57.80 -
4 Add extra for disposdig off the excavated stuff of
above item for lead of:
(A) 50 mt. To 100 mt. 22.00 cum 51.12 1,124.64
(B) 100 mt. To 200 mt. 22.00 cum 51.12 1,124.64
(C ) 200 mt. To 300 mt. 22.00 cum 51.12 1,124.64
5 Providing and laying Plain cement concrete 1:3:6
(1 cement : 3 coarse sand : 6 hand broken stone
aggregate 40mm nominal size) and curing
complete excluding cost of formwork in :

(A) Foundation and plinth 5.00 cum 1536.00 7,680.00


6 Supplying & filling FINE sand in filter beds for
preparation of filter bed upto average 5.0 mt.depth
below surrounding average ground level including
cost of sand, transporation for all leads, loading
unloading, spereading in layers as specified below.
loose thick ness at all depths dressing and levelling
dewatering sub soil or rain water if any etc.

5.00 cum 375.00 1,875.00


7 Supplying & filling GRAVEL in filter beds for
preparation of filter bed upto average 7.0 mt.depth
below surrounding average ground level including
cost of gravel, transporation for all leads, loading
unloading, spereading in layers as specified below.
loose thick ness at all depths dressing and levelling
dewatering sub soil or rain water if any etc.

(A) 3 to 6 mm 1.00 cum 1050.00 1,050.00


(B) 6 to 20 mm 2.00 cum 1050.00 2,100.00
(C ) 20 to 40 mm 2.00 cum 1050.00 2,100.00
(D) 40 to 60 mm 2.00 cum 1050.00 2,100.00

Item
Description Quantity Unit Rate Rs. Amount Rs.
No.

(1) (2) (3) (4) (5) (6)


8 Supplying & filling BOULDERS around central
water trough in a layer of 200 mm thick. In fillter
bed
2.00 cum 525.00 1,050.00

Page 18 Abstract Sheet


9 Filling available excavated earth (excluding rock) in
plinth, sides of foundation etc. in layers not
exceeding 20 cm. In depth consolidating each
deposited layer by ramming and watering.

35.00 cum 24.80 868.00


10 providing, lowering, laying & jointing in true line
and level 110 mm dia 4 kg/cm2 working pressure
rigid PVC pips for filter bed to bore well line fitted
consealed including all necessary fitting such as
bend, shoe bend etc. including testing of pipes &
joints fixing the same with PVC clips at 2.00 meters
c/c & jointed wih adhesive solvent cement including
the cost of all materials, fixing air and water tight
testing the line etc. complete as directed.

(a) 150 MM DIA. 20.00 RMT 295.50 5,910.00

Total for all Items 45641329.90

Page 19 Abstract Sheet


BOQ FOR ELECTRIFICATION OF FIRE ATATION AT
ASLALI

Section
Electrical Works Amount
No.
1 Internal Wiring 1,995,400.00
2 Distribution Boards 512,920.00
3 Cable Trench 461,250.00
4 Cable Tray ( Not Applicable ) NA
5 MV Cabling 387,810.00
6 Cable Termination 8,376.00
7 MV Switchgear 105000.00
8 Light Fixtures and Fans 1,440,925.00
9 Earthing 79,400.00
10 Lightning Arrestor ( Not Applicable ) NA
11 Telephone & Data Distribution 409,200.00
12 P.A. System 115,350.00
13 Street lighting 445,000.00
14 Miscellaneous 410,050.00
TOTAL FOR ELECTRIFICATION 6,370,681.00

REBET @ %

NET TOTAL ELECTRICAL WORKS 6,370,681.00

Page 20 Abstract Sheet


SECTION
DESCRIPTION QTY UNIT Rate Total
NO.

1.0 Internal Wiring


All the wiring, outlet points shall be done in a
surface / concealed manner with ISI approved
medium duty, rigid FR PVC, ISI conduit of
minimum 25 mm. dia. using 650 V FRLS copper
conductor wire, modular switches with suitable
plate, PVC / Metal back box with brass chromium /
cadmium plated machine screws etc.

1.1 Point Wiring


1.1.1 Wiring for the following light points with 1.5
sq.mm FRLS flexible copper conductor 1100
volts grade wires of approved make in
concealed or surface mounted 25 mm dia
medium guage PVC Conduit including providing
and fixing of 6 amps single pole rocker operated
flush mounted switch of approved quality colour
make & design in 2 mm thick GI box and
earthing of fixtures and the outlet box with 1.5
sq.mm PVC insulated copper conductor
stranded flexible "FRLS" wire.

a Primary Light point controlled by one single way 6


A switch.
530.00 no 800.00 424,000.00
b Primary light point controlled by one SP MCB 30.00 no 650.00 19,500.00
c Secondary light point controlled by same
switch / MCB 120.00 no 400.00 48,000.00
1.1.2 Wiring for the 2 way controlled light
points with 1.5 sq.mm FRLS flexible copper
conductor 1100 volts grade wires of
approved make in concealed or surface
mounted 25 mm dia medium guage PVC
Conduit including providing and fixing of 2
Nos. 6 amps 2 way rocker rocker operated
flush mounted switch of approved quality
colour make & design in 2 mm thick GI box
and earthing of fixtures and the outlet box
with 1.5 sq.mm PVC insulated copper
conductor stranded flexible "FRLS" wire.

a Primary light point controlled by two, two way 6 A


switch 13.00 no 1,200.00 15,600.00
b Secondary light point controlled by same switch
12.00 no 750.00 9,000.00

Page 21 Abstract Sheet


1.1.3 Wiring for the Ceiling Fan points with 1.5
sq.mm FRLS flexible copper conductor
1100 volts grade wires of approved make
in concealed or surface mounted 25 mm
dia medium guage PVC Conduit including
providing fan hook box, 6 amps switch and
300 watts electronic hum free fan regulator
of approved quality colour make & design in
2 mm thick GI box and earthing of
fixtures and the outlet box with 1.5 sq.mm
PVC insulated copper conductor stranded
flexible "FRLS" wire.
200.00 no 1,000.00 200,000.00
1.1.4 Wiring for the 250 volts single phase
and neutral 6 amps switched socket outlet
with 2.5 sq.mm FRLS flexible copper
conductor 1100 volts grade wires of
approved make in concealed or surface
mounted 25 mm dia medium guage PVC
Conduit including providing and fixing of 6
amps 5 pin switch socket outlet of approved
quality colour make & design in 2 mm thick
GI box and earthing of fixtures and the
outlet box with 1.5 sq.mm PVC insulated
copper conductor stranded flexible "FRLS"
wire.
a One 6 A x 5 pin 250 Volt socket outlet point
controlled by one 6 A switch located on board. 230.00 no 300.00 69,000.00
b 6 A x 5 pin 250 Volt switched socket outlet point at
convenient location. 550.00 no 850.00 467,500.00
1.1.5 Wiring for the 250 volts single phase
and neutral 16 amps switched socket
outlet with 2.5 sq.mm FRLS flexible copper
conductor 1100 volts grade wires of
approved make in concealed or surface
mounted 25 mm dia medium guage PVC
Conduit including providing and fixing of 16
amps 5 pin switch socket outlet of approved
quality colour make & design in 2 mm thick
GI box and earthing of fixtures and the
outlet box with 1.5 sq.mm PVC insulated
copper conductor stranded flexible "FRLS"
wire. 60.00 no 950.00 57,000.00
1.1.6 DO - as 1.1.5 but with4 sq.mm wire for phase &
Neutral & 2.5 sq. mm for Earthing 90.00 no 1,150.00 103,500.00
1.1.7 -Do- as 1.1.6 but With 20 Amp DP switch and
socket at different location 5.00 no 1,200.00 6,000.00

Page 22 Abstract Sheet


1.1.8 Wiring for thesingle phase and neutral
20 amps polycarbonate industrial 3 pin (IP
65/66) socket outlet with 20 amps double
pole MCB in a poly carbonate enclosure
with 4 sq.mm FRLS flexible copper
conductor 1100 volts grade wires of
approved make in concealed or surface
mounted 25 mm dia medium guage PVC
Conduit including providing and fixing of 16
amps socket in poly carbonate enclosure and
earthing of third pin of the socket and
withDP MCB of approved quality colour make
& design in 2 mm thick GI box /
polycarbonate enclosure and earthing of
fixtures and the outlet box with 2.5 sq.mm
PVC insulated copper conductor stranded
flexible "FRLS" wire. 4.00 no 1,200.00 4,800.00
1.1.9 Wiring for the Three phase and neutral
32 amps polycarbonate industrial 5 pin (IP
65/66) socket outlet with 32 amps Four pole
MCB in a poly carbonate enclosure with 4
x 4 sq.mm FRLS flexible copper conductor
1100 volts grade wires of approved make
in concealed or surface mounted 25 mm
dia medium guage PVC Conduit including
providing and fixing of 32 amps socket in poly
carbonate enclosure and neutral & earthing
pin of the socket and with FP MCB of
approved quality colour make & design in 2
mm thick GI box / polycarbonate enclosure
and earthing of fixtures and the outlet box
with 2 nos. of 2.5 sq.mm PVC insulated
copper conductor stranded flexible "FRLS"
wire.
5.00 no 4,000.00 20,000.00
1.1.10 Wiring for the Exhaust fan point with 1.5
sq.mm FRLS flexible copper conductor 1100
volts grade wires of approved make in
concealed or surface mounted 25 mm dia
medium guage PVC Conduit including providing
and fixing of 6 amps flush mounted switch at the
normal switch level in 2 mm thick GI box and 6
amps 3 pin flush mounted socket out of near
exhaust fan and earthing of exhaust fan through
the third pin of the socket outlet of approved
quality colour make & design in 2 mm thick GI
box and earthing of fixtures and the outlet box
with 1.5 sq.mm PVC insulated copper
conductor stranded flexible "FRLS" wire.
80.00 no 900.00 72,000.00

Page 23 Abstract Sheet


1.1.11 Wiring for the Bell point with 1.5 sq.mm
FRLS flexible copper conductor 1100 volts
grade wires of approved make in concealed or
surface mounted 25 mm dia medium guage PVC
Conduit including providing and fixing of 6 amps
flush mounted Bell switch in 2 mm thick GI box of
approved quality colour make & design in 2 mm
thick GI box and earthing of fixtures and the
outlet box with 1.5 sq.mm PVC insulated
copper conductor stranded flexible "FRLS" wire.

40.00 no 900.00 36,000.00


1.1.12 Supply and laying of 25 mm rigid PVC pipe of 1.6-
1.8 mm thickness 2,000.00 rmt 33.00 66,000.00

1.3 RACEWAYS & JUNCTION BOX


Providing and fixing 2 mm thick steel sheet factory
fabricated post galvanized raceway with internal
partition of the following sizes including providing
removable 3 mm thick GI cover, knock out holes
and fixing accessories earthing with 8 SWG
copper earth wire complete as required including
floor supports, bends, access boxes, tap off boxes
and cross over as per specification and site
requirement.

1.3.1 SITC of 100mm x 50 mm PVC Raceway with all


Accessary &Hardware. 25.00 mtr 500.00 12,500.00

1.4 MAINS : ( not for Point wiring )


1.4.1 Supplying and Laying of mains with Cu. PVC
insulated flexible wire with ISI and FIA approval for
650 V/ 1100 V with earth wires of Cu. PVC
insulated flexible wires with ISI approval for 650 V/
1100 V as earth wires to be drawn in Suitable dia
rigid PVC Pipe of Heavy Guage

1.4.1.1 Supplying and Laying of 4 nos. of 25 sq mm Cu.


flexible wires with 2 nos 6 sqmm Cu. flexible wires
to be drawn in 1 nos. of 65 mm dia Pipe
30.00 mtr 2,000.00 60,000.00
1.4.2 Supplying and Laying of mains with FRLS Cu.
PVC insulated flexible wire with ISI and FIA
approval for 650 V/ 1100 V with earth wires of
FRLS Cu. PVC insulated flexible wires with ISI
approval for 650 V/ 1100 V as earth wires to be
drawn in Suitable dia rigid PVC Pipe of Heavy
Guage
1.4.2.1 Supplying and Laying of 4 nos. of 10 sq mm Cu.
flexible wires with 2 nos 6 sqmm Cu. flexible wires
to be drawn in 2 nos. of 40 mm dia Pipe
50.00 mtr 500.00 25,000.00
1.4.2.2 Supplying and Laying of 4 nos. of 6 sq mm Cu.
flexible wires with 1 nos 4 sqmm Cu. flexible wires
to be drawn in 40 mm dia Pipe 50.00 mtr 400.00 20,000.00
1.4.2.3 Supplying and Laying of 2 nos. of 10 sq mm Cu.
flexible wires with 1 nos 6 sqmm Cu. flexible wires
to be drawn in 40 mm dia Pipe 50.00 mtr 270.00 13,500.00
1.4.2.4 Supplying and Laying of 2 nos. of 6 sq mm Cu.
flexible wires with 1 nos 4 sqmm Cu. flexible wires
to be drawn in 40 mm dia Pipe 50.00 mtr 225.00 11,250.00

Page 24 Abstract Sheet


1.4.2.5 Supplying and Laying of 2 nos. of 4 sq mm Cu.
flexible wires with 1 nos 2.5 sqmm Cu. flexible
wires to be drawn in 25 mm dia Pipe 50.00 mtr 175.00 8,750.00
1.4.2.6 Supplying and Laying of 2 nos. of 2.5 sq mm Cu.
flexible wires with 1 nos 2.5 sqmm Cu. flexible
wires to be drawn in 25 mm dia Pipe 50.00 mtr 100.00 5,000.00
1.4.2.7 Supply & Laying of 1.5 sq mm x 3 core round
flexible wire in prelaid pipe / Raceway. 70.00 mtr 50.00 3,500.00
1.4.2.8 Supply & Laying of 2.5 sq mm x 3 core round
flexible wires in prelaid pipe / Raceway. 50.00 mtr 70.00 3,500.00
1.4.2.9 Supply & Laying of 4 sq mm x 4 core round
flexible wires in prelaid pipe / Raceway. 100.00 mtr 120.00 12,000.00
1.4.2.10 Supply & Laying of 6 sq mm x 3 core round
flexible wires in prelaid pipe / Raceway. 1,350.00 mtr 150.00 202,500.00
Sub Total 1.0..... 1,995,400.00
2.0 Distribution Board
Supply, Assembling, grouting, levelling Connecting
& testing D.B of IP 43 of specified make.

2.1 Distribution Board-TPN


2.1.1 Supply, Erecting, testing and commissioning of
only TPN D.B. PPI type with space for FPMCB as
incoming and space for DPELMCB and 12
SPMCB as outgoing per phase (i.e. 16 way per
phase D.B.) 1.00 no 7,500.00 7,500.00
2.1.2 Supply, Erecting, testing and commissioning of
only TPN D.B. PPI type with space for FPMCB as
incoming and space for DPELMCB and 8 SPMCB
as outgoing per phase (i.e. 12 way per phase D.B.)
5.00 no 6,500.00 32,500.00
2.1.3 Supply, Erecting, testing and commissioning of
only TPN D.B. PPI type with space for FPMCB as
incoming and space for DPELMCB and 4 SPMCB
as outgoing per phase (i.e. 8 way per phase D.B.)
4.00 no 4,500.00 18,000.00
2.1.4 Supply, Erecting, testing and commissioning of
only TPN D.B. PPI type with space for FPMCB as
incoming and space for DPELMCB and 2 SPMCB
as outgoing per phase (i.e. 6 way per phase D.B.)
1.00 no 4,000.00 4,000.00
2.2 Distribution Board-SPN
2.2.1 Supply, Erecting, testing and commissioning of
SPN D.B. PPI type with space for DPELMCB as
incoming and 12 SPMCB as outgoing per phase
(i.e. 16 way D.B.) 3.00 no 2,500.00 7,500.00
2.2.2 Supply, Erecting, testing and commissioning of
SPN D.B. PPI type with space for DPELMCB as
incoming and 8 SPMCB as outgoing per phase
(i.e. 12 way D.B.) 39.00 no 1,800.00 70,200.00
2.2.3 Supply, Erecting, testing and commissioning of
SPN D.B. PPI type with space for DPELMCB as
incoming and 4 SPMCB as outgoing per phase
(i.e. 8 way D.B.) 1.00 no 1,500.00 1,500.00
2.2.4 Supply, Erecting, testing and commissioning of
SPN D.B. PPI type with space for DPELMCB as
incoming and 2 SPMCB as outgoing per phase
(i.e. 6 way D.B.) 1.00 no 1,200.00 1,200.00
2.3 MCB
2.3.1 6 to 32 A SP MCB 528.00 no 160.00 84,480.00
2.3.2 40 A SP MCB 1.00 no 310.00 310.00
2.3.3 63 A SP MCB 1.00 no 310.00 310.00
2.3.4 6 to 32 A DP MCB 39.00 no 440.00 17,160.00
2.3.5 40 A DP MCB 4.00 no 700.00 2,800.00

Page 25 Abstract Sheet


2.3.6 63 A DP MCB 2.00 no 700.00 1,400.00
2.3.7 25 A / 100 mA DP ELMCB 21.00 no 2,150.00 45,150.00
2.3.8 32 A / 100 mA DP ELMCB 63.00 no 2,150.00 135,450.00
2.3.9 40 A / 100 mA DP ELMCB 8.00 no 2,400.00 19,200.00
2.3.10 63 A / 100 mA DP ELMCB 3.00 no 2,780.00 8,340.00
2.3.11 25 A FP MCB 3.00 no 950.00 2,850.00
2.3.12 32 A FP MCB 3.00 no 950.00 2,850.00
2.3.13 40 A FP MCB 3.00 no 1,380.00 4,140.00
2.3.14 63 A FP MCB 1.00 no 1,380.00 1,380.00
2.3.15 Dual Channel Timer equivalent to Theben Make
TR612 TOP 2.00 no 1,500.00 3,000.00
2.3.16 20 Amp DP Dinrail Mouned Contactor Equivalent 2.00 no 2,500.00 5,000.00
2.3.17 40 Amp DP Dinrail Mouned Contactor Equivalent
to MDS make Cat. No. 004068 2.00 no 3,000.00 6,000.00
2.3.18 Sheet steel enclouser for DP MCB 41.00 no 200.00 8,200.00
2.3.19 Sheet steel enclouser for FP MCB 10.00 no 250.00 2,500.00
2.3.20 100 Amp. MCCB ( 25 KA ) with the Enclauser &
Both Side Cable end Box with the Handle with
Spreader Link 2.00 no 10,000.00 20,000.00
Sub Total 2.0..... 512,920.00
3.0 Cable Trench
3.1 Excavation and back filling of cable trenches
required for laying the cables directly buried in the
ground. This includes supplying and providing
cable markers at an interval of 10 meters. The
depth shall be app 1mtr and the width shall be as
per requirement 130.00 mt3 100.00 13,000.00
3.2 Supplying and spreading fine sand for a thickness
of 100 mm. and providing and laying bricks on all
the three sides. 130.00 rmt 25.00 3,250.00
3.3 Supplying all material for preparing Man hole of
600 x 600 or 600 mm round hole 15.00 no 12,000.00 180,000.00
3.4 Supplying all material for preparing Man hole of
750 x 750 or 750 mm round hole 3.00 no 12,500.00 37,500.00
3.5 Excavation and doing masionary work with plaster
on all the wall three sides and providing metal
RCC pre-cast slabs 35.00 mt3 6,500.00 227,500.00
Sub Total 3.0..... 461,250.00
5.0 Cables
Supplying & laying of following 1100 volt grade
XLPE insulated PVC sheathed aluminium /
Copper conductor armoured cables as per
specification in existing trenches, cable trays,
ducts, over bed of sand, clamped to wall with
suitable clamps including, saddles fixing bolts,
connecting testing and commissioning with
identification tags at every 10 mtr. & Both ends..

5.1 35 sq.mm x 3.5 c Al. cable 50.00 mt 366.00 18,300.00


5.2 25 sq.mm x 4 c Al. cable 200.00 mt 340.00 68,000.00
5.3 25 sq.mm x 4 c Cu. cable 30.00 mt 1,150.00 34,500.00
5.4 16 sq.mm x 4 c Al. cable 150.00 mt 290.00 43,500.00
5.5 16 sq.mm x 4 c Cu. cable 30.00 mt 747.00 22,410.00
5.6 10 sq.mm x 4 c Cu. Cable 100.00 mt 326.00 32,600.00
5.7 6 sq.mm x 4 c Cu. Cable 400.00 mt 383.00 153,200.00
5.8 4 sq.mm x 4 c Cu. Cable 50.00 mt 306.00 15,300.00
Sub Total 5.0..... 387,810.00
6.0 Cable Termination

Page 26 Abstract Sheet


Cable end termination of the following XLPE
insulated PVC sheathed aluminium/copper
conductor armoured cables of 1100 volt grade
including supplying and fixing of bimettalic Long
neck crimping lugs, Brass glands with earthing.

6.1 35 sq.mm x 3.5 c Al. cable 4.00 no 128.00 512.00


6.2 25 sq.mm x 4 c Al. cable 6.00 no 156.00 936.00
6.3 25 sq.mm x 4 c Cu. cable 6.00 no 166.00 996.00
6.4 16 sq.mm x 4 c Al. cable 8.00 no 150.00 1,200.00
6.5 16 sq.mm x 4 c Cu. cable 6.00 no 160.00 960.00
6.6 10 sq.mm x 4 c Cu. Cable 8.00 no 124.00 992.00
6.7 6 sq.mm x 4 c Cu. Cable 24.00 no 100.00 2,400.00
6.8 4 sq.mm x 4 c Cu. Cable 4.00 no 95.00 380.00
Sub Total 6.0..... 8,376.00
7.0 MV Switchgear & Power Panels
Design, fabrication, assembling, supply,
installation, testing and commissioning of Main LT
panel, Main Distribution Panels, Sub Distribution
panels and Final Distribution panels suitable for
415 V, 3 phase, 50 Hz, 4 wire power supply
system.
All large panels shall be provided with lifting
hooks. Distribution panels shall be fabricated in
accordance with the specifications.

1.0 Supporting rigid steel framework.


2.0 Cubicle type, 14 gauge CRCA sheet steel
enclosed.
3.0 Complete with interconnections and distribution
bus bars.
4.0 Proper bonding to earth.
5.0 Painting/lettering on Breakers and distribution
boards, the location they serve, providing on
each panel its circuit diagram.
6.0 Providing cable clamps / supports within
distribution boards cable alley.
7.0 TPN ACB’s / MCCB’s shall mean 3 pole ACB’s /
MCCB’s with adequate size of neutral link.

8.0 All MCB’s shall be of minimum 10 KA breaking


capacity.
9.0 The breaking capacity of MCCB’s are mentioned
panel wise. All MCCB’s shall be with thermal
magnetic releases upto 250 amps and
miroprocessor based
above 250 amps capacity, unless specified
otherwise.
10.0 All motor feeders MCCBs shall be of motor duty.

11.0 Distribution panels shall be Powder Coated with


Siemens gray paint shade no. RAL-7032 of IS-5.

12.0 Degree of protection for following type of


distribution panel enclosure shall be as per
IS:13947-1993.
a. IP 52 for indoor panels.
b. IP 54 for kitchen and laundry panels.
c. IP 55 for outdoor panels.
13.0 All MCCB’s shall be provided with operating
mechanism for door interlock & with the roraty
handle.

Page 27 Abstract Sheet


14.0 Current density of aluminium shall be 1 sq mm for
1.0 amps for rated current of bus bars and current
density of copper shall be 1 sq.mm for 1.25 amps
for rated current of bus bars.

15.0 Tinned copper earth bus as specified in the BOQ


shall be provided through out the length of each
board.
16.0 All measuring instruments (Meters) shall be of
digital electronic with LED of approved make and
compatible with BAS.
17.0 All hinged door shall be earthed through 2.5 sq
mm tinned braided copper wire.
18.0 All panels shall have provision of the following:

a. Pad locking of Switch board doors.


b. Pad locking of MCCB’s handles in “OFF” Position.

19.0 Additional set of C.T.s, potential free contacts,


connectors, contactors with wiring etc are to be
provided for BAS including space required for
various transducers
in Main Switch Board sections. Only transducers
shall be supplied by BAS contractor.

20.0 All MCB’s used for protection of resistive and


lightly inductive load shall be type “B”
characteristic and inductive (motor) load shall be
of type “C” characteristic
and discharge lamps and UPS etc. shall be of type
D characteristic.
21.0 All incoming and outgoing air circuit breakers shall
be placed on middle portion of the vertical in
single tier formation.
22.0 All PTs / control transformer shall be provided with
centre tap earth secondary.
23.0 G.A. Drawing should be checked & Finalised by
consultant before fabrication.

7.1.1 SITC of Residencial Common Area Panel 1.00 no 55,000.00 55,000.00


Incoming :
100 Amp FP MCCB With Rotary Handle ( 16 KA )
: 1 No.
Metering : - 1 no. of Load Manager equivalent to
Schneider make PM 210 with Appropriate CT of
class 0.5 & Control Fuse
1 no. of Digital type V, A, F meter with Appropriate
CT of class 0.5 & Control Fuse Equivalent to
Conserve Make ELF 3259
RYB-On-Off LED type Indicating Lamp / incoming

Busbar : Set of FP copper busbars of 100 amp


EC. grade & adequate Capacity insulated with
Heat shrinkable insulating sleeve & should be
tinned at all joints.
Outgoing :-
40 amp FP MCB :- 2 nos (10 KA).
32 amp FP MCB :- 1 nos (10 KA).

Page 28 Abstract Sheet


Drilling by rotary mud flush method in all type of
alluvial soil, the drilling shall be done by mud flush
rotary equipment and stores to be provided by the
contractor. Bore shall be round and shall stand
unceased for at least 72 hours.

6 - 32 amp DP MCB :- 2 nos (10 KA).


Panel should be as per SLD
7.1.2 SITC of Fire Station Panel 1.00 no 50,000.00 50,000.00
Incoming :
100 Amp FP MCCB With Rotary Handle ( 16 KA )
: 1 No.

Metering : - 1 no. of Load Manager equivalent to


Schneider make PM 210 with Appropriate CT of
1 no. of Digital type V, A, F meter with Appropriate
CT of class 0.5 & Control Fuse Equivalent to
Conserve Make ELF 3259

RYB-On-Off LED type Indicating Lamp / incoming

Busbar : Set of FP copper busbars of 100 amp


EC. grade & adequate Capacity insulated with
Heat shrinkable insulating sleeve & should be
tinned at all joints.
Outgoing :-
63 amp FP MCB :- 2 nos (10 KA).
40 amp FP MCB :- 1 nos (10 KA).
6 - 32 amp FP MCB:- 7 nos(10kA)
Panel should be as per SLD
Sub Total 7.0..… 105,000.00
8.0 Light Fixtures & Fans
8.1 A Supply, Install, Tesing and commissiong of light
fixtures with Control Gear, lamps and fans with all
necessary internal wiring.( Scope includes the
necessary hardware for the installation of the Light
Fixture concealed / Surface mounted)

8.1.1 1 x 28 W Mirolta type light fixture with lamp


equivalent to Philips make TGW 204/ 1 x TL5 28
Watt. 400.00 no 633.00 253,200.00
8.1.2 1 x 28 W Box Type fixture with electronic Hi-
frequency ballast with 28W T5 tube equivalent to
Philips make TMS 122 / 128
150.00 no 1,150.00 172,500.00
8.1.3 2 x 28 W Box Type fixture with electronic Hi-
frequency ballast with 28W T5 tube equivalent to
Philips make TMS 122 / 228 35.00 no 1,587.00 55,545.00
8.1.4 2 x 28 W M/O Type fixture with electronic Hi-
frequency ballast with 28W T5 tube equivalent to
Philips make TCS 398 / 228 D6 HF 5.00 no 3,623.00 18,115.00
8.1.5 1 x 11 W CFL MIROLTA type fixture with CFL
equivalent to Philips make FMS 200/111
80.00 no 518.00 41,440.00
8.1.6 1x 18 watt CFL down light fitting with the Lamps &
Choke equivalent to Philips make FCS 100 / 118
5.00 no 920.00 4,600.00
8.1.7 1 x 36 W IP65 Type fixture with electronic Hi-
frequency ballast with 36W T8 tube equivalent to
Philips make TCW 300 / 136 HF
20.00 no 2,358.00 47,160.00

8.1.8 2x 18 watt CFL Wall light fitting with the Lamps &
Choke equivalent to Wipro make WCP15218

Page 29 Abstract Sheet


50.00 no 2,500.00 125,000.00
8.1.9 1 x 150 Watt MH Type IP65 Flood Light Fitting
with the 150 Watt MH Lamp Equivalent to Philips
Make Cat. No. MWF 230 / 150 with control Gear
5.00 no 4,773.00 23,865.00
8.1B Street Light Fixture
8.1B.1 Supply, installation, testing and commisioning of
IP 65 protected 250 W MH / SON type fixtures
aesthetically designed, made of pressure die cast
alluminium housing ( LM6 grade ), Pot Optic
reflector with heat resistant toughned glasscover &
with a specially designed ribbed profile, High IP 65
: Lamp Compartment confirm to IP65 ingress
protection fully compliance with IEC598 &
Applicable IS standard for Road Lighting
luminaires use with SON-T PLUS PIA 250W lamp
with 33200 LUMENS LAMP/ 250 w MH with lamp
and control gear & complete to be fixed on the
street light poles should be of top mounting type
with toughened glass complete in all respect as
per specification integral type equivalent to Philips
Make Cat. No. Broadway-II CRP330 / SON-T 250
Watt.
8.00 no 7,200.00 57,600.00
8.1B.2 Supply, installation, testing and commisioning of
IP 65 protected 250 W MH / SON type fixtures
aesthetically designed, made of pressure die cast
alluminium housing ( LM6 grade ), Pot Optic
reflector with heat resistant toughned glasscover &
with a specially designed ribbed profile, High IP 65
: Lamp Compartment confirm to IP65 ingress
protection fully compliance with IEC598 &
Applicable IS standard for Road Lighting
luminaires use with SON-T PLUS PIA 250W lamp
with 33200 LUMENS LAMP/ 250 w MH with lamp
and control gear & complete to be fixed on the
street light poles should be of top mounting type
with toughened glass complete in all respect as
per specification integral type equivalent to Philips
Make Cat. No. Broadway-II CRP330 / SON-T 150
Watt.
15.00 no 6,900.00 103,500.00
8.1B.3 Supply, installation, testing and commisioning of
IP 65 protected 150 W MH / type CDMT METAL
HALIDE fixtures aesthetically designed, made of
pressure die cast alluminium housing ( LM6 grade
), Pot Optic reflector with heat resistant toughned
glasscover & with a specially designed ribbed
profile, High IP 65 : Lamp Compartment confirm to
IP65 ingress protection fully compliance with
IEC598 & Applicable IS standard for Road Lighting
luminaires use with CDM-T PLUS PIA 150W lamp
with 33200 LUMENS LAMP/ 150 w MH with lamp
and control gear & complete to be fixed on the
street light poles should be of top mounting type
with toughened glass complete in all respect as
per specification integral type equivalent to Philips
Make Cat. No. BERLIN CDS570/CDM-T 150 Watt.

5.00 no 20,000.00 100,000.00

Page 30 Abstract Sheet


8.2 Supply, Installation, testing and commissioning of
Fans ( Energy saving ) without fan regulator.

8.2.1 36" dia sweep high speed high breeze ceiling fans
white in colour. 5.00 no 1,250.00 6,250.00
8.2.2 48" dia sweep high speed high breeze ceiling fans
white in colour. 200.00 no 1,450.00 290,000.00
8.2.3 56" dia sweep high speed high breeze ceiling fans
white in colour. 5.00 no 1,650.00 8,250.00
8.2.4 Additional fan rod made out of 10 guage painted
GI pipe with all required accessories for fan 30.00 Rmt 50.00 1,500.00
8.4 Exhaust Fans :

8.4.1 SITC of light duty 225 mm. diameter propeller 5.00 no 1,400.00 7,000.00
8.4.2 SITC of light duty 305 mm. diameter propeller
exhaust fans with louvers 80.00 no 1,500.00 120,000.00
8.4.3 SITC of heavy duty 450 mm. diameter propeller
exhaust fans 3.00 no 1,800.00 5,400.00
Sub Total 8.0..... 1,440,925.00
9.0 Earthing
9.1 Providing and laying of following tined copper / GI
plate electrode, with 2 Nos 50 x 6 mm copper
strips from earth plate electrode to inspection
chamber, 50 mm dia medium class GI pipe, CI
funnel with 20 gauge GI wire mesh, masonry
chamber 1000 x 500 mm with concrete base C I
heavy duty / chequered plate manhole cover with
frame painted with bitumastic paint and packing
with mixture of charcoal and common salt around
plate electrode including digging of pit upto
permanent moisture level and as per soil condition
but not less than 3 meters and back filling as
required.

9.1.1 600 x 600 x 3.15 mm cu.plate no 10,000.00


9.1.2 450 x 450 x 3.15 mm cu. plate no 8,500.00
9.1.3 600 x 600 x 3.15 mm GI plate no 7,500.00
9.1.4 450 x 450 x 3.15 mm GI plate 4.00 no 6,500.00 26,000.00
9.2 Earth wire/strips :
Supply and laying cu. earthing strips for
interconnecting the earthing stations, panels, DB's
etc. in built up trenches, on walls/ceiling, buried in
ground generally as specified and shown on
drawings complete with : fixing accessories

Corrosion protection of buried conductors with


bituminous coating and covered with PVC tapes.

9.2.1 50 x 6 mm cu. Tape mtr 1,050.00


9.2.2 32x 6 mm cu. Tape mtr 450.00
9.2.3 25 x 3 mm GI. Tape 150.00 mtr 300.00 45,000.00
9.2.4 No.8 gauge bare cu. earth wire 150.00 mtr 50.00 7,500.00
9.3 Earth Link : 40mm x 6 mm earth link fixed by 2.00 no 450.00 900.00
Sub Total 9.0..... 79,400.00
11.0 Telephone Distribution
Providing and installing of all conduiting and
structured cabling for telephone system including
providing and fixing of the following:
1.0 All necessary specials and fittings

2.0 Approved cover plates for inspection, junction


and outlet boxes.
3.0 2 mm thick outlet boxes and junction boxes.

Page 31 Abstract Sheet


4.0 All fixing accessories such as clips, nails, screws
etc.
5.0 Providing and fixing approved saddles, hooks and
grouting the same as required, in the case of all
exposed conduit work.
6.0 Embedding conduits and accesssories in wall,
floors etc. during construction and / or cutting
chases and making good as necessary in the
case of all concealed conduit work.

11.1 Supply, installation, testing and commissioning of


Krone make Protector panel with swivel input stub
and splice chamber as required, for the incoming
P & T lines. The panel shall have provision for
both top and bottom cable feeding. The
conductors in the swivel stub and splice chamber
shall have 24 AWG conductors and satisfy the
fuse link requirement. 5 Nos. test cards shall also
be provided.

1.1 50 pair protector panel 1.00 no 1,000.00 1,000.00


11.2 Supply and installation, testing and commissioning
following size KRONE make telephone tag block in
lockable 16 gauge sheet steel enclosure complete
as required.
11.2.1 10 pair Krone type tag block 1.00 no 250.00 250.00
11.2.2 20 pair Krone type tag block 1.00 no 500.00 500.00
11.2.3 50 pair Krone type tag block 2.00 no 1,500.00 3,000.00
Supply, installation, connection, testing and
11.1 PVC & HDPE Conduits
11.1.1 Supply & laying of 25 mm dia. rigid PVC conduit of
2.0-2.2 mm thick heavy gauge with all accessories.
1,600.00 mtr 42.00 67,200.00
11.1.2 Supply & laying of 40 mm dia. rigid PVC conduit of
2.1 -2.3 mm thick medium gauge with all
accessories. 200.00 mtr 90.00 18,000.00
11.1.3 Providing and laying the following HDPE pipe of 6
Kg/ Cm2 working pressure laid in ground including
cost of digging, 150 mm sand all around the pipe,
brick protection and back filling including all
accessories i.e. bends, reducers, flanges of
approved make and design complete as required.

a. 25 mm OD with 2.3 mm wall thickness 100.00 mtr 60.00 6,000.00


11.2 Cabling
Supply, installation, testing and commisioning
of the following 0.51 dia Tinned Copper un
armoured telephone cables.

11.2.1 10 pair unarmoured telephone cable mtr 150.00


11.2.2 20 pair unarmoured telephone cable mtr 250.00
11.2.3 50 pair unarmoured telephone cable 200.00 mtr 600.00 120,000.00
11.4 Telephone Point Wiring

Page 32 Abstract Sheet


Supply and laying of specified make 0.51 mm dia
Tinned copper telephone wire of specified make
to be done in prelaid PVC pipe of 25 mm
dia/raceway of specified make, but without the
cost of pipe or raceway. (the wire is to be drawn
from Krone connector )

11.4.1 5 pair telephone wire 1,800.00 mtr 50.00 90,000.00


11.4.2 2 pair telephone wire 1,600.00 mtr 40.00 64,000.00
11.4.3 Supply, installation, testing and commissioning of
4 pair Category 6 UTP cable consisting of 23
AWG solid copper conductors and as per the
specification. The cable should have flexible
jacket and ripcord for easy stripability.
100.00 mtr 40.00 4,000.00
11.5 Telephone Outlet Point
Supply and installation of flush mounted Category
6 T 568 A or B outlet. The plastic shall be high
impact, flame-retardant UL rated thermoplastic.
Dust cover / Blank shall be provided to protect
unused face plate openings. Termination cap and
plastic cover shall be provided to protect jack
wiring.
11.5.1 one telephone point to be done with telephone
outlet socket RJ-11 (jack type) and box of the
specified make. 90.00 no 350.00 31,500.00
11.5.2 one Data I/O point to be done with data outlet
socket of RJ-45 and Face Plate, box of the
specified make. 5.00 no 750.00 3,750.00
Sub Total 11.0..... 409,200.00
12.0 P. A. Syatem
12.1 SITC of 4 channel hi-fi music playing system (2-
cassette playing facility, Auto-reverse, recording
facility) with 3-CD changer, amplifier, including
mounting rack. The music system should have
facility to receive & broadcast the automatic
emergency fire alarm anouncements generated by
Fire alarm control panel & should be capable to
connect with the EPABX system for
announcement purpose. These fire alarm
anouncements should override the ongoing music
playback. (Philips / Bosch make).
1.00 no 15,000.00 15,000.00
12.2 SITC of 6W- 8 ohms 6" dia ceiling mounted music
speakers with line matching transformer for 100/70
V output line, with bottom grill. (Philips make LDB
8353 + B377or equivalent from specified
make).(Philips / Bosch make)
5.00 no 750.00 3,750.00
12.3 SITC of 6W- 8 ohms wall mounted Projection
music speakers with line matching transformer for
100/70 V output line. (Philips / Bosch make)
10.00 no 1,000.00 10,000.00
12.4 SITC OF microphone with press to call switch for
Public address system, (Philips / Bosch make)
1.00 no 1,500.00 1,500.00
12.5 SITC of local volume control -cum ON-OFF switch
with flush mounting metal boxes, mounting plate
matching with electrical switches (Same make as
switch) 1.00 no 350.00 350.00
12.6 Supply & Laying of 2 Core X 1sq.mm Shielded
wire with 25 mm dia PVC Pipe With all
accessories. ( For Fire & P.A. ) 150.00 mtr 40.00 6,000.00

Page 33 Abstract Sheet


12.7 Supply & Laying of RG 6 TV wire with PVC Pipe
With all accessories. 1,100.00 mtr 40.00 44,000.00
12.8 SITC of the TV Socket with with the Concealed
box, Face plate etc… 85.00 no 350.00 29,750.00
12.9 SITC of the 4 way Splitter 10.00 no 500.00 5,000.00
Sub Total 12.0..… 115,350.00
13 Street Lighting
13.1 Supply & installation of 11Mtr (Approx 36') high
(coloured and primered in minimum 2 coats of PU
based paint in approved colour and shade) made
out of M.S. tubular pole of dia 194 mm top swaged
with base plate with stiffner, primered and painted
street light pole The column shall also be provided
with flush door at the bottom with proper
strengthening to the cutout of the door opening. A
junction/ looping box with Heavy duty 3 phase
connector shall be built into the pole with single
arm bracket from the 42 to 60 mm dia pipe with
Suitable size of M.S. sleeve /reducer duly welded
at the end of the arm, The total play should not be
more than 10 mm as per drawing.

11.00 no 20,000.00 220,000.00


1) 8 way connector and 6A MCB
2) 50 mm diameter GI pipe for each cable entry.
Pipe length is up to 3.5 mtr. Per cable
3) Wiring up to the light fixture from the junction
box using 3nos x 1.5 sq.mm. flexible copper wires
/ Fixture of specified make.
4) Concrete coping with base plate with stiffner.

5) Sprial/Coil Type Earthing from the 8 swg Cu.


Wire of 2.5 mtr. With the suitable size pipe with
clamps and painting.
6) Radium stip of two colour at suitable height

7) Excavation & back filling for erection of poles.


Debris to be removed from the site to suitable
location as per the instruction of the engineer
incharge
13.2 Supply & installation of 9Mtr (Approx 31') high
(coloured and primered in minimum 2 coats of PU
based paint in approved colour and shade) made
out of M.S. tubular pole of dia 194 mm top swaged 15.00 no 15,000.00 225,000.00

Page 34 Abstract Sheet


1) 8 way connector and 6A MCB
2) 50 mm diameter GI pipe for each cable entry.
Pipe length is up to 3.5 mtr. Per cable
3) Wiring up to the light fixture from the junction
box using 3nos x 1.5 sq.mm. flexible copper wires
/ Fixture of specified make.
4) Concrete coping with base plate with stiffner.

5) Sprial/Coil Type Earthing from the 8 swg Cu.


Wire of 2.5 mtr. With the suitable size pipe with
clamps and painting.
6) Radium stip of two colour at suitable height

7) Excavation & back filling for erection of poles.


Debris to be removed from the site to suitable
location as per the instruction of the engineer
incharge
Sub Total 13.0..... 445,000.00
14.0 Miscellaneous
14.1 Supplying & Erecting conventional type Carbon
Dioxide fire extinguishers of ISI approved of 2.0
kgs 10.00 no 2,000.00 20,000.00
14.2 Suppplying & Erecting automatic emergency light
with maintenance free battery for 20 watts tube.
4.00 no 1,300.00 5,200.00
14.3 Supplying & Erecting Rubber mat 1.1 KV 1000 x
2000 x 6 mm 2.00 no 2,000.00 4,000.00
14.4 Providing and erecting danger notice board for
medium voltage installation to be erected as per
I.S. The board should be 150 x 150 mm.
4.00 no 1,500.00 6,000.00
14.5 Providing printed instruction chart both in English
& REGIONAL LANGUAGE & duly framed out on
glass for treatment of person suffering from
Electric shock. 4.00 no 1,000.00 4,000.00
14.6 S & L only PVC medium gauge in concealed
manner with GI pulling wire of 25 mm dia with all
accessories. 250.00 mtr 33.00 8,250.00
14.7 S & L only PVC medium gauge in concealed
manner with GI pulling wire of 32 mm dia with all
accessories. 200.00 mtr 55.50 11,100.00
14.8 S & L only PVC medium gauge in concealed
manner with GI pulling wire of 40 mm dia with all
accessories. 100.00 mtr 81.00 8,100.00
14.9 S & L only PVC medium gauge in concealed
manner with GI pulling wire of 50 mm dia with all
accessories. 100.00 mtr 117.00 11,700.00
14.10 Supplying , fabricating and installation of various
sizes MS race way / junction
boxes/clamps/hangers for Cable Tray, Light
Fixture made out ot 14 guage
sheet/Angle/Flat/rod/ channel etc with all
necessary accessories like bend, juncation boxes,
coupler, Anchor fastner, Bolt Nuts, etc.. & work
from MS structure for other work with anchor
fastner and necessary hardware with necessary
welding has to be done to complete the job from
ISA / ISMC / PLATE. The job also includes to
paint the structure with two coats of red oxide and
two coats color of enamel paint as approved and
recommended by consultant. Complete in all
respect
500.00 Kg. 60.00 30,000.00

Page 35 Abstract Sheet


14.11 Providing & laying. Double walled corrugated
pipes (DWC) of polyethylene(conforming to IS
14930 II ) Anti Rodent type with necessary
connecting accessories of same material at
required depth for laying of cable. below ground
/ road surface for enclosing cable and backfilling
the same to make ground as per original.
.
(A)50 mm dia 50.00 mt 110.00 5,500.00
(B)90 mm dia 100.00 mt 162.00 16,200.00
(C)120 mm dia. 800.00 mt 225.00 180,000.00
14.12 SITC of Water Tight Junction Box of Hensel make
Cat. No. KG9003IN or equivalent. With necessary
clamp for mounting of the J.B. ( All the cable / wire
connections to the JB shall be with the Water tight
Glands only ) 30.00 no 2,000.00 60,000.00
14.13 Liason / Follow UP with Supply Co.
Filling the necessary application to supply co.
following up and getting the supply filling the
necessary test report to the supply co. inclusive.
All official fees including security deposits will be
paid by the client and out of pocket expenses shall
be of contractor. 1.00 Lot 40,000.00 40,000.00
Sub Total 14.0..... 410,050.00

Total Amount 6,370,681.00