Professional Documents
Culture Documents
Instant Sensible [Btu/hr] Delayed Sensible [Btu/hr] Latent [Btu/hr] Total [Btu/hr] Percent of Total [%]
Envelope
Roof - 0 - 0 0.0
Other - Roof - 0 - 0 0.0
Ceiling - 0 - 0 0.0
Glass - Conduction 10,866 - - 10,866 5.6
Glass - Solar - 15,623 - 15,623 8.0
Door - 66 - 66 0.0
Wall - 7,110 - 7,110 3.6
Below-grade Wall - 0 - 0 0.0
Partition - -978 - -978 -0.5
Other - Wall - 0 - 0 0.0
Exterior Floor - 0 - 0 0.0
Interior Floor - 0 - 0 0.0
Slab - 0 - 0 0.0
Other - Floor - 0 - 0 0.0
Infiltration 4,794 - 604 5,399 2.8
Subtotal 15,660 21,821 604 38,085 19.5
Internal Gains
People 32,020 6,239 42,866 81,124 41.6
Lights 0 0 - 0 0.0
Return Air - Lights 0 - - 0 0.0
Equipment 0 0 0 0 0.0
Subtotal 32,020 6,239 42,866 81,124 41.6
Systems
Zone Ventilation 32,773 - 3,185 35,958 18.5
Transfer Air 0 - 0 0 0.0
DOAS Direct to Zone 0 - 0 0 0.0
Return Air - Other 0 - - 0 0.0
Supply Fan Heat 12,531 - - 12,531 6.4
Power Generation Equipment 0 0 - 0 0.0
Refrigeration 0 - 0 0 0.0
Water Use Equipment 0 - 0 0 0.0
HVAC Equipment Loss 0 0 - 0 0.0
Subtotal 45,304 0 3,185 48,489 24.9
Total
Sizing Factor Adjustment 0 - - 0 0.0
Time Delay Correction - 27,119 - 27,119 13.9
Grand Total 92,984 55,179 46,655 194,818 100.0
System Load Summary AHU 00 COOLING
Instant Sensible [Btu/hr] Delayed Sensible [Btu/hr] Latent [Btu/hr] Total [Btu/hr] Percent of Total [%]
Envelope
Roof - 0 - 0 0.0
Other - Roof - 0 - 0 0.0
Ceiling - 31,346 - 31,346 13.4
Glass - Conduction 10,511 - - 10,511 4.5
Glass - Solar - 3,522 - 3,522 1.5
Door - 3,195 - 3,195 1.4
Wall - 13,391 - 13,391 5.7
Below-grade Wall - 0 - 0 0.0
Partition - 7,434 - 7,434 3.2
Other - Wall - 0 - 0 0.0
Exterior Floor - 0 - 0 0.0
Interior Floor - 0 - 0 0.0
Slab - 0 - 0 0.0
Other - Floor - 0 - 0 0.0
Infiltration 4,710 - 833 5,543 2.4
Subtotal 15,222 58,888 833 74,943 32.1
Internal Gains
People 32,020 1,721 42,866 76,607 32.8
Lights 0 0 - 0 0.0
Return Air - Lights 0 - - 0 0.0
Equipment 0 0 0 0 0.0
Subtotal 32,020 1,721 42,866 76,607 32.8
Systems
Zone Ventilation 32,757 - 5,253 38,010 16.3
Transfer Air 0 - 0 0 0.0
DOAS Direct to Zone 0 - 0 0 0.0
Return Air - Other 0 - - 0 0.0
Supply Fan Heat 16,480 - - 16,480 7.1
Power Generation Equipment 0 0 - 0 0.0
Refrigeration 0 - 0 0 0.0
Water Use Equipment 0 - 0 0 0.0
HVAC Equipment Loss 0 0 - 0 0.0
Subtotal 49,237 0 5,253 54,490 23.3
Total
Sizing Factor Adjustment 0 - - 0 0.0
Time Delay Correction - 27,426 - 27,426 11.7
Grand Total 96,479 88,035 48,952 233,466 100.0
System Load Summary AHU 02 COOLING
Instant Sensible [Btu/hr] Delayed Sensible [Btu/hr] Latent [Btu/hr] Total [Btu/hr] Percent of Total [%]
Envelope
Roof - 0 - 0 0.0
Other - Roof - 0 - 0 0.0
Ceiling - 0 - 0 0.0
Glass - Conduction 12,131 - - 12,131 5.0
Glass - Solar - 0 - 0 0.0
Door - 2,296 - 2,296 1.0
Wall - 37,822 - 37,822 15.7
Below-grade Wall - 0 - 0 0.0
Partition - 32,000 - 32,000 13.3
Other - Wall - 0 - 0 0.0
Exterior Floor - 0 - 0 0.0
Interior Floor - 0 - 0 0.0
Slab - 0 - 0 0.0
Other - Floor - 0 - 0 0.0
Infiltration 3,417 - 761 4,178 1.7
Subtotal 15,548 72,119 761 88,429 36.6
Internal Gains
People 32,020 0 42,866 74,886 31.0
Lights 0 0 - 0 0.0
Return Air - Lights 0 - - 0 0.0
Equipment 0 0 0 0 0.0
Subtotal 32,020 0 42,866 74,886 31.0
Systems
Zone Ventilation 25,187 - 5,773 30,960 12.8
Transfer Air 0 - 0 0 0.0
DOAS Direct to Zone 0 - 0 0 0.0
Return Air - Other 0 - - 0 0.0
Supply Fan Heat 18,104 - - 18,104 7.5
Power Generation Equipment 0 0 - 0 0.0
Refrigeration 0 - 0 0 0.0
Water Use Equipment 0 - 0 0 0.0
HVAC Equipment Loss 0 0 - 0 0.0
Subtotal 43,291 0 5,773 49,065 20.3
Total
Sizing Factor Adjustment 0 - - 0 0.0
Time Delay Correction - 28,956 - 28,956 12.0
Grand Total 90,860 101,075 49,400 241,335 100.0
System Load Summary AHU 03 COOLING
Instant Sensible [Btu/hr] Delayed Sensible [Btu/hr] Latent [Btu/hr] Total [Btu/hr] Percent of Total [%]
Envelope
Roof - 0 - 0 0.0
Other - Roof - 0 - 0 0.0
Ceiling - 25,937 - 25,937 11.4
Glass - Conduction 11,571 - - 11,571 5.1
Glass - Solar - 4,651 - 4,651 2.0
Door - 683 - 683 0.3
Wall - 12,915 - 12,915 5.7
Below-grade Wall - 0 - 0 0.0
Partition - 6,641 - 6,641 2.9
Other - Wall - 0 - 0 0.0
Exterior Floor - 0 - 0 0.0
Interior Floor - 0 - 0 0.0
Slab - 0 - 0 0.0
Other - Floor - 0 - 0 0.0
Infiltration 4,684 - 775 5,459 2.4
Subtotal 16,255 50,828 775 67,857 29.8
Internal Gains
People 32,020 2,518 42,866 77,403 34.0
Lights 0 0 - 0 0.0
Return Air - Lights 0 - - 0 0.0
Equipment 0 0 0 0 0.0
Subtotal 32,020 2,518 42,866 77,403 34.0
Systems
Zone Ventilation 32,758 - 4,751 37,509 16.5
Transfer Air 0 - 0 0 0.0
DOAS Direct to Zone 0 - 0 0 0.0
Return Air - Other 0 - - 0 0.0
Supply Fan Heat 15,894 - - 15,894 7.0
Power Generation Equipment 0 0 - 0 0.0
Refrigeration 0 - 0 0 0.0
Water Use Equipment 0 - 0 0 0.0
HVAC Equipment Loss 0 0 - 0 0.0
Subtotal 48,652 0 4,751 53,403 23.5
Total
Sizing Factor Adjustment 0 - - 0 0.0
Time Delay Correction - 28,845 - 28,845 12.7
Grand Total 96,927 82,191 48,392 227,509 100.0
System Load Summary AHU 04 COOLING
Instant Sensible [Btu/hr] Delayed Sensible [Btu/hr] Latent [Btu/hr] Total [Btu/hr] Percent of Total [%]
Envelope
Roof - 0 - 0 0.0
Other - Roof - 0 - 0 0.0
Ceiling - -7,395 - -7,395 -3.7
Glass - Conduction 11,668 - - 11,668 5.8
Glass - Solar - 30,723 - 30,723 15.4
Door - -112 - -112 -0.1
Wall - 3,971 - 3,971 2.0
Below-grade Wall - 0 - 0 0.0
Partition - -4,260 - -4,260 -2.1
Other - Wall - 0 - 0 0.0
Exterior Floor - 0 - 0 0.0
Interior Floor - 0 - 0 0.0
Slab - 0 - 0 0.0
Other - Floor - 0 - 0 0.0
Infiltration 4,837 - 712 5,548 2.8
Subtotal 16,505 22,927 712 40,143 20.1
Internal Gains
People 32,020 11,222 42,866 86,108 43.1
Lights 0 0 - 0 0.0
Return Air - Lights 0 - - 0 0.0
Equipment 0 0 0 0 0.0
Subtotal 32,020 11,222 42,866 86,108 43.1
Systems
Zone Ventilation 32,766 - 3,998 36,763 18.4
Transfer Air 0 - 0 0 0.0
DOAS Direct to Zone 0 - 0 0 0.0
Return Air - Other 0 - - 0 0.0
Supply Fan Heat 12,954 - - 12,954 6.5
Power Generation Equipment 0 0 - 0 0.0
Refrigeration 0 - 0 0 0.0
Water Use Equipment 0 - 0 0 0.0
HVAC Equipment Loss 0 0 - 0 0.0
Subtotal 45,719 0 3,998 49,717 24.9
Total
Sizing Factor Adjustment 0 - - 0 0.0
Time Delay Correction - 23,652 - 23,652 11.8
Grand Total 94,244 57,801 47,575 199,620 100.0
System Load Summary AHU 01 HEATING
Instant Sensible [Btu/hr] Delayed Sensible [Btu/hr] Latent [Btu/hr] Total [Btu/hr] Percent of Total [%]
Envelope
Roof - - - 0 0.0
Other - Roof - - - 0 0.0
Ceiling - - - 0 0.0
Glass - Conduction - - - 0 0.0
Glass - Solar - - - 0 0.0
Door - - - 0 0.0
Wall - - - 0 0.0
Below-grade Wall - - - 0 0.0
Partition - - - 0 0.0
Other - Wall - - - 0 0.0
Exterior Floor - - - 0 0.0
Interior Floor - - - 0 0.0
Slab - - - 0 0.0
Other - Floor - - - 0 0.0
Infiltration - - - 0 0.0
Subtotal 0 0 0 0 0.0
Internal Gains
People - - - 0 0.0
Lights - - - 0 0.0
Return Air - Lights - - - 0 0.0
Equipment - - - 0 0.0
Subtotal 0 0 0 0 0.0
Systems
Zone Ventilation 2,155,617 - 1,366,428,05 1,368,583,67 100.0
5 2
Transfer Air - - - 0 0.0
DOAS Direct to Zone - - - 0 0.0
Return Air - Other 0 - - 0 0.0
Supply Fan Heat 0 - - 0 0.0
Power Generation Equipment - - - 0 0.0
Refrigeration - - - 0 0.0
Water Use Equipment - - - 0 0.0
HVAC Equipment Loss - - - 0 0.0
Subtotal 2,155,617 0 1,366,428,05 1,368,583,67 100.0
5 2
Total
Sizing Factor Adjustment 0 - - 0 0.0
Time Delay Correction - 0 - 0 0.0
Grand Total 2,155,617 0 1,366,428,05 1,368,583,67 100.0
5 2
System Load Summary AHU 00 HEATING
Instant Sensible [Btu/hr] Delayed Sensible [Btu/hr] Latent [Btu/hr] Total [Btu/hr] Percent of Total [%]
Envelope
Roof - - - 0 0.0
Other - Roof - - - 0 0.0
Ceiling - - - 0 0.0
Glass - Conduction - - - 0 0.0
Glass - Solar - - - 0 0.0
Door - - - 0 0.0
Wall - - - 0 0.0
Below-grade Wall - - - 0 0.0
Partition - - - 0 0.0
Other - Wall - - - 0 0.0
Exterior Floor - - - 0 0.0
Interior Floor - - - 0 0.0
Slab - - - 0 0.0
Other - Floor - - - 0 0.0
Infiltration - - - 0 0.0
Subtotal 0 0 0 0 0.0
Internal Gains
People - - - 0 0.0
Lights - - - 0 0.0
Return Air - Lights - - - 0 0.0
Equipment - - - 0 0.0
Subtotal 0 0 0 0 0.0
Systems
Zone Ventilation 2,155,832 - 1,366,564,66 1,368,720,49 100.0
0 2
Transfer Air - - - 0 0.0
DOAS Direct to Zone - - - 0 0.0
Return Air - Other 0 - - 0 0.0
Supply Fan Heat 0 - - 0 0.0
Power Generation Equipment - - - 0 0.0
Refrigeration - - - 0 0.0
Water Use Equipment - - - 0 0.0
HVAC Equipment Loss - - - 0 0.0
Subtotal 2,155,832 0 1,366,564,66 1,368,720,49 100.0
0 2
Total
Sizing Factor Adjustment 0 - - 0 0.0
Time Delay Correction - 0 - 0 0.0
Grand Total 2,155,832 0 1,366,564,66 1,368,720,49 100.0
0 2
System Load Summary AHU 02 HEATING
Instant Sensible [Btu/hr] Delayed Sensible [Btu/hr] Latent [Btu/hr] Total [Btu/hr] Percent of Total [%]
Envelope
Roof - - - 0 0.0
Other - Roof - - - 0 0.0
Ceiling - - - 0 0.0
Glass - Conduction - - - 0 0.0
Glass - Solar - - - 0 0.0
Door - - - 0 0.0
Wall - - - 0 0.0
Below-grade Wall - - - 0 0.0
Partition - - - 0 0.0
Other - Wall - - - 0 0.0
Exterior Floor - - - 0 0.0
Interior Floor - - - 0 0.0
Slab - - - 0 0.0
Other - Floor - - - 0 0.0
Infiltration - - - 0 0.0
Subtotal 0 0 0 0 0.0
Internal Gains
People - - - 0 0.0
Lights - - - 0 0.0
Return Air - Lights - - - 0 0.0
Equipment - - - 0 0.0
Subtotal 0 0 0 0 0.0
Systems
Zone Ventilation 2,155,617 - 1,366,428,05 1,368,583,67 100.0
5 2
Transfer Air - - - 0 0.0
DOAS Direct to Zone - - - 0 0.0
Return Air - Other 0 - - 0 0.0
Supply Fan Heat 0 - - 0 0.0
Power Generation Equipment - - - 0 0.0
Refrigeration - - - 0 0.0
Water Use Equipment - - - 0 0.0
HVAC Equipment Loss - - - 0 0.0
Subtotal 2,155,617 0 1,366,428,05 1,368,583,67 100.0
5 2
Total
Sizing Factor Adjustment 0 - - 0 0.0
Time Delay Correction - 0 - 0 0.0
Grand Total 2,155,617 0 1,366,428,05 1,368,583,67 100.0
5 2
System Load Summary AHU 03 HEATING
Instant Sensible [Btu/hr] Delayed Sensible [Btu/hr] Latent [Btu/hr] Total [Btu/hr] Percent of Total [%]
Envelope
Roof - - - 0 0.0
Other - Roof - - - 0 0.0
Ceiling - - - 0 0.0
Glass - Conduction - - - 0 0.0
Glass - Solar - - - 0 0.0
Door - - - 0 0.0
Wall - - - 0 0.0
Below-grade Wall - - - 0 0.0
Partition - - - 0 0.0
Other - Wall - - - 0 0.0
Exterior Floor - - - 0 0.0
Interior Floor - - - 0 0.0
Slab - - - 0 0.0
Other - Floor - - - 0 0.0
Infiltration - - - 0 0.0
Subtotal 0 0 0 0 0.0
Internal Gains
People - - - 0 0.0
Lights - - - 0 0.0
Return Air - Lights - - - 0 0.0
Equipment - - - 0 0.0
Subtotal 0 0 0 0 0.0
Systems
Zone Ventilation 2,155,617 - 1,366,428,05 1,368,583,67 100.0
5 2
Transfer Air - - - 0 0.0
DOAS Direct to Zone - - - 0 0.0
Return Air - Other 0 - - 0 0.0
Supply Fan Heat 0 - - 0 0.0
Power Generation Equipment - - - 0 0.0
Refrigeration - - - 0 0.0
Water Use Equipment - - - 0 0.0
HVAC Equipment Loss - - - 0 0.0
Subtotal 2,155,617 0 1,366,428,05 1,368,583,67 100.0
5 2
Total
Sizing Factor Adjustment 0 - - 0 0.0
Time Delay Correction - 0 - 0 0.0
Grand Total 2,155,617 0 1,366,428,05 1,368,583,67 100.0
5 2
System Load Summary AHU 04 HEATING
Instant Sensible [Btu/hr] Delayed Sensible [Btu/hr] Latent [Btu/hr] Total [Btu/hr] Percent of Total [%]
Envelope
Roof - - - 0 0.0
Other - Roof - - - 0 0.0
Ceiling - - - 0 0.0
Glass - Conduction - - - 0 0.0
Glass - Solar - - - 0 0.0
Door - - - 0 0.0
Wall - - - 0 0.0
Below-grade Wall - - - 0 0.0
Partition - - - 0 0.0
Other - Wall - - - 0 0.0
Exterior Floor - - - 0 0.0
Interior Floor - - - 0 0.0
Slab - - - 0 0.0
Other - Floor - - - 0 0.0
Infiltration - - - 0 0.0
Subtotal 0 0 0 0 0.0
Internal Gains
People - - - 0 0.0
Lights - - - 0 0.0
Return Air - Lights - - - 0 0.0
Equipment - - - 0 0.0
Subtotal 0 0 0 0 0.0
Systems
Zone Ventilation 2,155,617 - 1,366,428,05 1,368,583,67 100.0
5 2
Transfer Air - - - 0 0.0
DOAS Direct to Zone - - - 0 0.0
Return Air - Other 0 - - 0 0.0
Supply Fan Heat 0 - - 0 0.0
Power Generation Equipment - - - 0 0.0
Refrigeration - - - 0 0.0
Water Use Equipment - - - 0 0.0
HVAC Equipment Loss - - - 0 0.0
Subtotal 2,155,617 0 1,366,428,05 1,368,583,67 100.0
5 2
Total
Sizing Factor Adjustment 0 - - 0 0.0
Time Delay Correction - 0 - 0 0.0
Grand Total 2,155,617 0 1,366,428,05 1,368,583,67 100.0
5 2