You are on page 1of 1

RAIN WATER HARVESTING SEPTIC TANK CALCULATION

INVERT LEVEL CALCULATION


RAIN WATER HARVESTING TANK CALCULATION -
ANNUAL RAINFALL OF MUMBAI = 2300MM FORMULA :-
TOTAL AREA OF TERRACE = 1435 M^2 IC TO IC DISTANCE /60+INVERT LEVEL
RUN OFF CO-EFFICIENT OF CEMENT = 0.8 TOTAL NUMBER OF IC CHAMBERS:-9
TOTAL RAINWATER COLLECTED = ANNUAL RAIN x AREA OF
IC CHAMBER 1
TERRACE x RUN OFF CO-EFFICIENT OF CEMENT
= 2.3 x 1435 x 0.8
DISTANCE(M)/60+INVERT LEVEL
= 2640.4 M^3 14/60+500=730MM
= 264*10^4 L IC CHAMBER 2
DRY DAYS = 60 DAYS DISTANCE FROM IC1/60+INVERT LEVEL FROM PREVIOUS CALCULATION
FOR SCHOOL 8/60+730=863MM
ASSUMING NUMBER OF PEOPLE =500 IC CHAMBER 3
WATER REQUIRED FOR ONE PERSON = 30L/PERSON 11/60+863=1043MM
VOLUME OF TANK = NO. OF PEOPLE x DRY DAYS x IC CHAMBER 4
WATER/PERSON 13/60+1043=1253MM
= 500 x 60 x 30 IC CHAMBER 5
= 9,00,000 L 11/60+1253=1433MM
= 900M^3 IC CHAMBER 6
VOLUME = L x B x H 6/60+1433=1533MM
900M^3 = 2B^2 x 2.5 ( LET L = 2B, H = 2.5 INCLUDING FREE
BOARD OF 0.3M)
IC CHAMBER 7
B = 13.5 M L = 27 M
DROP CHAMBER
VOLUME = 13x27x2.5 IC CHAMBER 8
=877.5 M^3 DISTANCE(M)/60+INVERT LEVEL
CALCULATION OF 30% OF LENGTH AND BREADTH OF 7/60+500=610MM
TANK: IC CHAMBER 9
L= 9 M 9/60+610=760MM
B= 4.05 M DROP CHAMBER
H= 2.5M ------
DISCONNECTING CHAMBER
(DISTANCE BETWEEN DISCONNECTING CHAMBER TO SEPTIC TANK/60+THE HIGHEST DEPTH VALUE )
4/60+1533=1593MM
~1.5M DEPTH/ LEVEL OF SEPTIC TANK

OUTLET

4.05M MAN HOLE 700MM

VENTILATING PIPE CONCRETE ROOF

GL

9M

PIPE

INLET OUTLET
12MM THICK PCC

MAN HOLE 700MM MAN HOLE 700MM MAN HOLE 700MM BRICK BOTTOM
RCC SLAB

OUTLET
BRICK WALL SECTION

SECTIONAL PLAN
2.5M

RCC WALL
IC CHAMBER

RWH TANK
CEMENT CONCRETE

KUNAL SIRWANI
SEPTIC TANK AND RWH TANK CALCULATIONS 1:250 EVS- SEM IV
D.Y.P.U.S.O.A

You might also like