Setting Management
2
Proprietary and Confidential
Getting started
• Baud: 115200
• Data bits: 8 You may use any Serial
• Parity: None Application such as Hyper
• Stop bits: 1
Terminal, PuTTY, TeraTerm
etc…
• Flow Control: None
3
Proprietary and Confidential
General notes on CLI
IP-10:/>
Note that the > sign indicates your current directory in the CLI tree
All functions & features can be configured faster and easier using the WEB
based EMS
4
Proprietary and Confidential
General Commands
IP-10:/ >?
IP-10:/ls
IP-10:/lsp
IP-10:/ > exit
IP-10:/ > cd
IP-10:/ > cd ..
5
Proprietary and Confidential
Command History
6
Proprietary and Confidential
Reading current IP
To read current IP type the following:
IP-10:/>cd management/networking/ip-address/
IP-10:/ management/networking/ip-address>
Note that the prompt has changed. Now, type get ip-address:
7
Proprietary and Confidential
Setting new IP
Now, let us set a new IP for the MNG:
You may lose remote management connection to the unit if this value
is changed incorrectly.
Are you sure? (yes/no):
8
Proprietary and Confidential
Connecting IDU to EMS
1. Connect your EMS/NMS to the IDU (port 7) with ETH CAT.5 cable
9
Proprietary and Confidential
Management Troubleshooting
In case PC cannot PING IDU –
1.Check your ETH cable – it might not be inserted properly (broken PIN)
2.Verify the management port is enabled in the EMS General/Management configuration
3.Make sure you connect to a management-enabled port (7, 6 or 5)
4.Verify right LED is ON (see below)
5.Verify your PC is in the same subnet as the IDU
6.In case your IDU is connected to a router: set the IDU’s Default GW = Router IP
7.In case your PC is connected to several IDUs (through switch/hub) – make sure every
IDU has a unique IP
10
Proprietary and Confidential
Back to factory defaults
IP-10:/> cd management/mng-services/cfg-service
IP-10:/management/mng-services/cfg-service>set-to-default
11
Proprietary and Confidential
Thank You !