Module Coverage • Alternating voltages and currents, AC values, RMS, average, form factor, peak factor • Single Phase RL, RC, RLC Series and parallel circuits, Power and power factor- Numerical • Balanced three-phase systems- Star and delta Connections • Electrical Safety, Fuses and Earthing How 3 –Phase EMF is Induced 3-Phase Power Generation 3-Phase Circuit What is Balanced? Understand Phase Voltage and Line Voltage Star Configuration Voltage Star Configuration Current Star-Power Delta Configuration Voltage Delta Configuration Current Delta-Power VL V I L 3I IL W 3VL cos 3 W 3VL I L cos To Keep in Mind Numerical-1 A star-connected load of (8+j6) Ω/ phase is connected to a 3-phase, 230V, 50 Hz supply. Find the line current, power factor, power, and reactive power. Ans Z=10<39.9 ohm Ephase=133 V, IL=Iphase=13.27, p.f=0.8 P=4239 W, Q= 3179 VAr Numerical-2 A delta-connected load of (3-j4) Ω is connected to a 3-phase, 415V, 50 Hz supply. Find the line current, power factor, power, and reactive power. Find line currents for the unbalanced delta-connected load of the figure given. Assume the phase sequence to be RYB and the Voltage is 200 V. IR= 13.53<-86.5 IY=8.42<-63.2 IB=21.51<102.4