Pemeriksaan eksentrisitas

e=

Mu 5289.232
=
=3.09 m=3090 mm
Pu 1710.63

e min =0.1 x h=0.1 x 1500=150 mm


e > emin struktur dengan beban eksentris
Letak garis netral pada keadaan balance:

c b=

600
600
. d=
.1440=960 mm
600+ fy
600+300

Pnb=0.85 . f ' c . b . a+ A s' . fyAs . fy


0.85 x 30 x 8000 x ( 0.85 x 960 ) +88357.3 x 24088357.3 x 240
166464000 N
1664640 kN

Pub= . Pnb
0.65 x 1664640
1082016 kN

Mnb =0.85 . f ' c . b . a d d ' '

a
+ A s ' . fy . ( d d ' d ' ' ) + As . fy . d ' '
2

Mnb =0.85 x 50 x 8000 x ( 0.85 x 960 ) 1440690

816
+ 88357.3 x 240
2

( 144060690 ) +88357.3 x 240 x 690


Mnb =0.277 x 109 +14.3 x 10 9+14.6 x 109
Mnb =29177 kNm

e b=

Mnb
29177
=
=0.027 m=27 mm
Pnb 1082016

Mnb =29.177 x 109 Nmm

Pu = 1710.63 kN

Pu < Pub

Pub = 1082016 kN
e = 3090 mm

e > eb
eb = 27 mm
Penampang mengalami keruntuhan tarik
Analisa kapasitas penampang yang mengalami keruntuhan tarik:

m=

fy
300
=
=7.06
'
0.85 x f c 0.85 x 50

m' =m1=7.061=6.06
=

As
88357.3
=
=7.7 x 103
b . d 8000 x 1440

'=

As
88357.3
3
=
=7.7 x 10
b . d 8000 x 1440

e ' =e+ d '' =

3090 +690 = 3780

Kapasitas penampang

{(

'

'

Pn=0.85 x 50 x 8000 x 1440 7.7 x 103 x 6.067.7 x 103 x 7.06+1

Pn=489600000 [1.6327+ ( 3568321+0.0545 )0.5 ]


Pn=9.24 x 1011 N
Pn=9.24 x 108 kN

Pu= . Pn=0.65 x 9.24 x 10 =6 x 10 kN >1.710 10 kN


Pu > Pn penampang kuat
Perhitungan tulangan geser
V

= 1710 ton

0.5

( )] }

e'
e'
e'
d'
Pn=0.85 . f c . b . d m m+ 1 + 1
+2 ( m' m' ) + ' m' 1
d
2
d
d
'

{(

]
[

3780
3780 2
3780
+ 1
+2
( 7.7 x 1
1440
2
1440

Vu 1710
=
=2850 ton

0.6
Vc=

f'c
xb x d
6

50
x 8000 x 1440
6
13576450 N
1357 ton

V c =0.75 x 1357=1017.75 ton


2850 > 1017.75 ; Vu > Vc diperlukan tulangan geser

V S =V nV c
V S=

Vu
V c

V S =28501357
V S =1493 ton

[ ] [ ]
[ ]

2 f ' c
2 50
b x d=
8000 x 1440
3
3
2 f'c
b x d=54305800 N
3

[ ]

2 f ' c
b x d=5430.58 ton