Severity CRITICAL
Sampling Point :
Sampling
Method
Problem : Copper Comments : The tested oil sample is found to be at CRITICAL condition. Copper content is
found to be high which indicates wearing of rotating and reciprocating
component.
Note:1) For representative sample, Please collect oil from proper sampling
point and Sampling method and mention it.2) Carry out oil sampling for
analysis at regular interval (OEM Recommended) to monitor the wear trend.
Customer Note :
Report ID -> Units Test Limits ULR-TC5865
19027267P
Particulars Methods
Total HMR 0
Top up Volume
Severity CRITICAL
Contaminants
Silicon (Si) mg/Kg ASTM 15 1.4
D5185
QR48 Rev. No.1 dt. 01.11.2018 www.ultralabs.co.in Page 1 of 2
Report ID -> Units Test Limits ULR-TC5865
19027267P
Particulars Methods
Total HMR 0
Top up Volume
Severity CRITICAL
Additive Elements
Calcium (Ca) mg/Kg ASTM 5.5
D5185
Magnesium (Mg) mg/Kg ASTM <0.5
D5185
Cadmium (Cd) mg/Kg ASTM <0.5
D5185
Boron (B) mg/Kg ASTM <0.5
D5185
Zinc (Zn) mg/Kg ASTM 47.6
D5185
Phosphorus (P) mg/Kg ASTM 18.6
D5185
Barium (Ba) mg/Kg ASTM <0.5
D5185
Molybdenum mg/Kg ASTM <0.5
(Mo) D5185
This is Computer generated Report. *** End of Analysis Report *** Review and Authorized by
COMMENTS –
From the Ferrography analysis of the given oil sample, White non-ferrous particle and
Cutting wear has been observed.
Normal rubbing wear has also observed which may due to contact/friction between two
components.