1.0 Introduction
This report presents a calculation and proposal of light weight steel roof trusses for the
proposed 34 Units Semi Detached Single Storey House of Villa Mas Project. The structural
concept adopted for the roofing system consists of roof truss design by using high-tensile
light weight steel of lip channel section.
The structural steel roof truss form is generally designed for the following critical cases or
conditions :
_______________________________________________________________________________________________________
/conversion/tmp/scratch/478566300.doc -1-
SKYCO INDUSTRIES SDN. BHD.
PROPOSED 34 UNITS SEMI DETACHED SINGLE STOREY HOUSE OF VILLA MAS PROJECT
FOR : TETUAN EMICO DEVELOPMENT SDN. BHD.
2.3.1 General
The lightweight structural steel roof truss has been designed to ensure the fulfillment
of structural integrity, stability and serviceability, ease of construction, to satisfy the
requirement of durability, cost effectiveness and also towards aesthetic value.
2.3.2 Materials
i. All structural materials incorporated in the proposal are complied with relevant
Malaysian Standard and other well known International Standard by using Lipped
Channel profile with material strength of 550 N/mm2.
i. Loads and Forces that have been considered in the design could be outlined as
follows :
- Dead Load consists of self-weight of truss, concrete roof tiles, battens and other
associated elements.
- Wind Load
- Construction Load and Live Load
- Maintenance or Services Load
ii. Dead Load included the weight of the materials forming a permanent part of the
structural elements and all other permanent equipment and materials attached
thereto.
_______________________________________________________________________________________________________
/conversion/tmp/scratch/478566300.doc -2-
SKYCO INDUSTRIES SDN. BHD.
PROPOSED 34 UNITS SEMI DETACHED SINGLE STOREY HOUSE OF VILLA MAS PROJECT
FOR : TETUAN EMICO DEVELOPMENT SDN. BHD.
Dead Load
Live Load
( Ref : BRE Digest 346 – The Assessment of Wind Load and complied with CP3 : Chapter V :
Part 2 : 1993)
_______________________________________________________________________________________________________
/conversion/tmp/scratch/478566300.doc -3-
SKYCO INDUSTRIES SDN. BHD.
PROPOSED 34 UNITS SEMI DETACHED SINGLE STOREY HOUSE OF VILLA MAS PROJECT
FOR : TETUAN EMICO DEVELOPMENT SDN. BHD.
CR = 1.0 (Figure 1 of BRE Digest 346 )
VZ/V10 = (z/10)α
where,
V10 = wind speed at 10 meter above ground level
= 35 m/s
α = 0.16 for open country
z = height of building
thus,
VZ = V10 (z/10)α
= 35 (3.2/10)0.16
= 29.17 m/s
Dynamic pressure, qs = k (VZ)2
= 0.613 (29.17)2
= 0.52 kN/m2
External Pressure Coefficients Cpe for pitch roofs of rectangular clad buildings
DATA
Building Height, h 3.2 metre
Building Width, w 14.846 metre
Building height and width ratio, h/w 0.215 < 1/2
Roof angle 25 degrees
Wind angle 0 degree
_______________________________________________________________________________________________________
/conversion/tmp/scratch/478566300.doc -4-
SKYCO INDUSTRIES SDN. BHD.
PROPOSED 34 UNITS SEMI DETACHED SINGLE STOREY HOUSE OF VILLA MAS PROJECT
FOR : TETUAN EMICO DEVELOPMENT SDN. BHD.
Windward, WW = - 0.20
Leeward, WL = - 0.40
Whilst for Internal coefficient, C pi which is referred to Appendix E of the same reference gives
the following;
Therefore :
During Construction
WW = (Cpe – Cpi) qs
= 0.052 kN/m2
WL = (Cpe – Cpi) qs
= - 0.052 kN/m2
Permanent
WW = (Cpe – Cpi) qs
= - 0.208 kN/m2
WL = (Cpe – Cpi) qs
= - 0.312 kN/m2 (This highest value will be used in analysis and design for the
trusses)
2.4 Calculations
_______________________________________________________________________________________________________
/conversion/tmp/scratch/478566300.doc -5-
SKYCO INDUSTRIES SDN. BHD.
PROPOSED 34 UNITS SEMI DETACHED SINGLE STOREY HOUSE OF VILLA MAS PROJECT
FOR : TETUAN EMICO DEVELOPMENT SDN. BHD.
Section SI7540-75
Depth, D 75 mm
Breadth, B 40 mm
Lips, s 9 mm
Thickness, t 0.75 mm
Weight 0.95 kg/m
Area, A 123.2 mm2
Second Moment of Area Ixx 114.2 x 103 mm4
Iyy 24.7 x 103 mm4
Radius of Gyration rxx 30.4 mm
ryy 14.1 mm
Elastic Modulus Zxx 3.1 x 103 mm3
Zyy 1.0 x 103 mm3
Torsional Constant, J 23.3 mm4
Warping Constant, Cw 28.4 cm6
b) Section Capacity
_______________________________________________________________________________________________________
/conversion/tmp/scratch/478566300.doc -6-
SKYCO INDUSTRIES SDN. BHD.
PROPOSED 34 UNITS SEMI DETACHED SINGLE STOREY HOUSE OF VILLA MAS PROJECT
FOR : TETUAN EMICO DEVELOPMENT SDN. BHD.
For trusses analysis and design, trusses marked as T3 and T8 were chosen since
they were having the most critical conditions in term of loading and span. Please
refer to APPENDIX 1 (Staad-Pro Output Results).
3.0 Conclusion
From the Staad-Pro output results, the proposed section, SI7540-75 for top and bottom
chords including for the internal members of the roof trusses are adequate to withstand the
ultimate for both construction and permanent loads.
_______________________________________________________________________________________________________
/conversion/tmp/scratch/478566300.doc -7-
SKYCO INDUSTRIES SDN. BHD.
PROPOSED 34 UNITS SEMI DETACHED SINGLE STOREY HOUSE OF VILLA MAS PROJECT
FOR : TETUAN EMICO DEVELOPMENT SDN. BHD.
4.0 Appendix 1
(Staad-Pro Output Results)
_______________________________________________________________________________________________________
/conversion/tmp/scratch/478566300.doc -8-
SKYCO INDUSTRIES SDN. BHD.
PROPOSED 34 UNITS SEMI DETACHED SINGLE STOREY HOUSE OF VILLA MAS PROJECT
FOR : TETUAN EMICO DEVELOPMENT SDN. BHD.
5.0 Drawings
_______________________________________________________________________________________________________
/conversion/tmp/scratch/478566300.doc -9-