Project Summary

Location and Weather


Project Project Name
Address
Calculation Time 17 January 2020 01:23 AM
Report Type Standard
Latitude 26.14°
Longitude 91.74°
Summer Dry Bulb 35 °C
Summer Wet Bulb 28 °C
Winter Dry Bulb 19 °C
Mean Daily Range 8 °C

Building Summary
Inputs
Building Type Multi Family
Area (SF) 619
Volume (CF) 6,037.48
Calculated Results
Peak Cooling Total Load (W) 8,811.0
Peak Cooling Month and Hour August 13:00
Peak Cooling Sensible Load (W) 6,503.1
Peak Cooling Latent Load (W) 2,307.9
Maximum Cooling Capacity (W) 8,709.3
Peak Cooling Airflow (CFM) 701
Peak Heating Load (W) 692.4
Peak Heating Airflow (CFM) 110
Checksums
Cooling Load Density (W/ft²) 14.24
Cooling Flow Density (CFM/SF) 1.13
Cooling Flow / Load (CFM/ton) 279.90
Cooling Area / Load (SF/ton) 247.00
Heating Load Density (W/ft²) 1.12
Heating Flow Density (CFM/SF) 0.18

Zone Summary - Default


Inputs
Area (SF) 619
Volume (CF) 6,037.48
Cooling Setpoint 23 °C
Heating Setpoint 21 °C
Supply Air Temperature 12 °C
Number of People 21
Infiltration (CFM) 0
Air Volume Calculation Type Split System(s) with Natural Ventilation
Relative Humidity 46.00% (Calculated)
Psychrometrics
Psychrometric Message None
Cooling Coil Entering Dry-Bulb Temperature 29 °C
Cooling Coil Entering Wet-Bulb Temperature 21 °C
Cooling Coil Leaving Dry-Bulb Temperature 12 °C
Cooling Coil Leaving Wet-Bulb Temperature 13 °C
Mixed Air Dry-Bulb Temperature 29 °C
Calculated Results
Peak Cooling Load (W) 8,709.3
Peak Cooling Month and Hour June 13:00
Peak Cooling Sensible Load (W) 6,459.8
Peak Cooling Latent Load (W) 2,249.5
Peak Cooling Airflow (CFM) 701
Peak Heating Load (W) 692.4
Peak Heating Airflow (CFM) 110
Peak Ventilation Airflow (CFM) 110
Checksums
Cooling Load Density (W/ft²) 14.07
Cooling Flow Density (CFM/SF) 1.13
Cooling Flow / Load (CFM/ton) 283.17
Cooling Area / Load (SF/ton) 249.89
Heating Load Density (W/ft²) 1.12
Heating Flow Density (CFM/SF) 0.18
Ventilation Density (CFM/SF) 0.18
Ventilation / Person (CFM) 5

Cooling Heating
Components Percentage of Percentage of
Loads (W) Loads (W)
Total Total
Wall 664.4 7.63% 213.0 30.77%
Window 377.0 4.33% 79.4 11.46%
Door 229.4 2.63% 99.2 14.32%
Roof 3,259.7 37.43% 169.4 24.46%
Skylight 0.0 0.00% 0.0 0.00%
Partition 0.0 0.00% 0.0 0.00%
Infiltration 0.0 0.00% 0.0 0.00%
Ventilation 1,723.2 19.79% 131.5 18.98%
Lighting 401.0 4.60%
Power 141.3 1.62%
People 1,784.5 20.49%
Plenum 0.0 0.00%
Fan Heat 128.8 1.48%
Reheat 0.0 0.00%
Total 8,709.3 100% 692.4 100%

Default Spaces
Space Area Volume Peak Cooling Cooling Airflow Peak Heating Heating Airflow
Name (SF) (CF) Load (W) (CFM) Load (W) (CFM)
1 Space 117 1,170.00 995.5 102 107.3 21
2 master
168 1,680.00 1,372.5 140 145.4 30
bed
3 living
216 2,005.74 3,136.6 321 201.0 38
room
4 Guest
118 1,181.74 1,352.7 138 107.4 21
room

Space Summary - 1 Space


Inputs
Area (SF) 117
Volume (CF) 1,170.00
Wall Area (SF) 328
Roof Area (SF) 126
Door Area (SF) 18
Partition Area (SF) 0
Window Area (SF) 25
Skylight Area (SF) 0
Lighting Load (VA) 130
Power Load (VA) 63
Number of People 3
Sensible Heat Gain / Person (Btu/h) 250.0
Latent Heat Gain / Person (Btu/h) 155.0
Infiltration Airflow (CFM) 0
Space Type Dormitory Bedroom
Calculated Results
Peak Cooling Load (W) 995.5
Peak Cooling Sensible Load (W) 968.2
Peak Cooling Latent Load (W) 27.3
Peak Cooling Airflow (CFM) 102
Peak Heating Load (W) 107.3
Peak Heating Airflow (CFM) 21

Cooling Heating
Components Percentage of Percentage of
Loads (W) Loads (W)
Total Total
Wall 142.9 14.35% 46.3 43.20%
Window 62.3 6.26% 14.8 13.81%
Door 25.6 2.57% 13.7 12.78%
Roof 638.2 64.11% 32.4 30.21%
Skylight 0.0 0.00% 0.0 0.00%
Partition 0.0 0.00% 0.0 0.00%
Infiltration 0.0 0.00% 0.0 0.00%
Lighting 16.2 1.63%
Power 19.4 1.95%
People 90.9 9.13%
Plenum 0.0 0.00%
Total 995.5 100% 107.3 100%

Space Summary - 2 master bed

Inputs

Area (SF) 168


Volume (CF) 1,680.00
Wall Area (SF) 413
Roof Area (SF) 179
Door Area (SF) 18
Partition Area (SF) 0
Window Area (SF) 50
Skylight Area (SF) 0
Lighting Load (VA) 186
Power Load (VA) 91
Number of People 3
Sensible Heat Gain / Person (Btu/h) 250.0
Latent Heat Gain / Person (Btu/h) 155.0
Infiltration Airflow (CFM) 0
Space Type Dormitory Bedroom
Calculated Results
Peak Cooling Load (W) 1,372.5
Peak Cooling Sensible Load (W) 1,345.3
Peak Cooling Latent Load (W) 27.3
Peak Cooling Airflow (CFM) 140
Peak Heating Load (W) 145.4
Peak Heating Airflow (CFM) 30

Cooling Heating
Components Percentage of Percentage of
Loads (W) Loads (W)
Total Total
Wall 163.7 11.93% 56.1 38.59%
Window 137.1 9.99% 29.6 20.38%
Door 25.3 1.84% 13.7 9.43%
Roof 909.3 66.25% 45.9 31.60%
Skylight 0.0 0.00% 0.0 0.00%
Partition 0.0 0.00% 0.0 0.00%
Infiltration 0.0 0.00% 0.0 0.00%
Lighting 20.5 1.49%
Power 27.1 1.98%
People 89.5 6.52%
Plenum 0.0 0.00%
Total 1,372.5 100% 145.4 100%

Space Summary - 3 living room

Inputs

Area (SF) 216


Volume (CF) 2,005.74
Wall Area (SF) 479
Roof Area (SF) 227
Door Area (SF) 73
Partition Area (SF) 0
Window Area (SF) 51
Skylight Area (SF) 0
Lighting Load (VA) 453
Power Load (VA) 116
Number of People 10
Sensible Heat Gain / Person (Btu/h) 275.0
Latent Heat Gain / Person (Btu/h) 275.0
Infiltration Airflow (CFM) 0
Space Type Dining Area - Family Dining
Calculated Results
Peak Cooling Load (W) 3,136.6
Peak Cooling Sensible Load (W) 2,572.5
Peak Cooling Latent Load (W) 564.2
Peak Cooling Airflow (CFM) 321
Peak Heating Load (W) 201.0
Peak Heating Airflow (CFM) 38

Cooling Heating
Components Percentage of Percentage of
Loads (W) Loads (W)
Total Total
Wall 194.0 6.19% 57.7 28.72%
Window 153.8 4.90% 30.2 15.05%
Door 145.2 4.63% 54.7 27.20%
Roof 1,154.4 36.81% 58.3 29.02%
Skylight 0.0 0.00% 0.0 0.00%
Partition 0.0 0.00% 0.0 0.00%
Infiltration 0.0 0.00% 0.0 0.00%
Lighting 348.8 11.12%
Power 89.7 2.86%
People 1,050.6 33.50%
Plenum 0.0 0.00%
Total 3,136.6 100% 201.0 100%

Space Summary - 4 Guest room

Inputs

Area (SF) 118


Volume (CF) 1,181.74
Wall Area (SF) 355
Roof Area (SF) 127
Door Area (SF) 23
Partition Area (SF) 0
Window Area (SF) 8
Skylight Area (SF) 0
Lighting Load (VA) 106
Power Load (VA) 35
Number of People 5
Sensible Heat Gain / Person (Btu/h) 250.0
Latent Heat Gain / Person (Btu/h) 200.0
Infiltration Airflow (CFM) 0
Space Type Restrooms
Calculated Results
Peak Cooling Load (W) 1,352.7
Peak Cooling Sensible Load (W) 1,074.3
Peak Cooling Latent Load (W) 278.4
Peak Cooling Airflow (CFM) 138
Peak Heating Load (W) 107.4
Peak Heating Airflow (CFM) 21

Cooling Heating
Components Percentage of Percentage of
Loads (W) Loads (W)
Total Total
Wall 163.8 12.11% 52.9 49.24%
Window 23.8 1.76% 4.7 4.38%
Door 33.3 2.46% 17.1 15.92%
Roof 557.8 41.24% 32.7 30.46%
Skylight 0.0 0.00% 0.0 0.00%
Partition 0.0 0.00% 0.0 0.00%
Infiltration 0.0 0.00% 0.0 0.00%
Lighting 15.4 1.14%
Power 5.1 0.38%
People 553.5 40.92%
Plenum 0.0 0.00%
Total 1,352.7 100% 107.4 100%