Activity: Welding and Gas Cutting (REV 01-04-12-2018) Project Title: GC 32 – NEW GATHERING CENTRE For SEK EF 1931 / JI 2035 Project No: JI - 2035 Site/Facility: Permit No: Work Area: KOC Emergency Contact Number: 160 Date: 97299100 (Mobile) Hard Hat, Safety Shoes, Safety Goggles, Hand Gloves, Dust Mask, Coverall, Personal Protective Equipment: Apron, Welding Hood, Multi Gas Detector
RISK RATING Ensure the worksite is free from flammable / toxic vapor or liquid by safe preparation (isolation, Presence of flammable / depressurizing, draining, venting, toxic Vapor or Liquid flushing, purging as required) The entry of non – certified Fire & Explosion equipment (Gas Cylinder Banks, Crane, Vehicles etc.) to be authorized under Permit to Work Non – compliance of KOC System. Pre - work HSEMS High Keep the fire extinguishers & fire Low hoses in ready condition. Unintended Shutdown of HSEMS Procedures - Doc. No. Facility / Equipment SA.KOC.021 ‘Welding & Cutting’; Doc. No. SA.KOC.004 “Permit to Unauthorized Work Work”. Identify the safety override required for the work. Take a Hot Work Permit and other associated permits from Asset Owner. Ensure the gas cutting equipment (blowpipe, hoses, oxy-acetylene Defective Tools cylinders, pressure gauge) are free from defect. Radiation from Welding Flame / Rays (Flash Eye) Wear protective goggles & Clothing.
Radiation from Welding Ensure proper ventilation and fume
Flame / Rays (Flash Eye) extraction equipment in case of welding inside an enclosure Burns Cutting / Welding Medium Wear long sleeved coverall, leather Low Falling of Sparks apron; welder’s hood. Flash Back Fire Enclose the welding area through Tarpaulin. Provide a check valve (flash back arrester) between oxy-acetylene hose & Oxy-acetylene Cylinder gas regulator. near the Hot Work area Keep oxy – acetylene cylinders at least 5 meters away from hot work area. Isolate the cylinder when not in use. 4 Page 1 of 4 JSA No. EF-1928-HSE-00 (Rev-00) Ensure proper wind up & housekeeping at worksite. Windup & Scattered Material Low The accessories (regulator, Housekeeping blowpipe, hose, isolation valve, Low gauge) not being used must be disconnected from gas cylinder and stored separately.