Radiography Corrosion Assessment Inspection Report

Inspection Details
Client INEOS Report No. BIS-DK-RT-1052
Project 2022 RBI Location NINI A
Contract No. CS-2040534 PO/Request No. 4501070489
Test Date 26/04/2022 Workpack No. C081-IP2022-NA
Description Profile Radiography to selected inspection points on RBI CSOPE - C081-IP2022-NA.
Drawing No. 1364-200.idw Rev.03
P & ID Drawing No. C081-DONG-R-XC-72-0001-001 REV.1.5A Line No. 1210-72-VN01 - Foam Tank
Material Type Stainless Steel Surface Condition Good
Material Thickness 2,77mm Surface Temperature Ambient - 10°
Test Restrictions None Diagnostic Area 100%
Equipment, Technique & Application Method
Procedure No. TMS/30/P/59 Ver No. 4
Technique No. Basic Technique (TA) Ver No. 4
Technique Std. BS EN ISO 20769-1 : 2018
Acceptance Criteria C080-INEO-K-KF-0001_1.3_003
Client Procedure No. TBA Stress Relief N/A
Gamma
Container Type Delta 880 SAL ID D7286
Source Type IR-192 Source ID 34907M Strength 7,7 Ci Source Size (mm) 2x1.1x2.3
Film/Plate MFR GE Film/Plate Type IPC2 Size(s) Various Exposure Time (Ci Mins) 25
Screen Type Pb Front (mm) 0.125 Back (mm) 0.125 Class TA Class TB
Scanner Type CRx25P Scanner SAL ID 22154 Laptop SAL ID 22155
Scan Gain Medium Scan Resolution 100 BSR (Microns) 100Mic - 4.95lp/mm
SNRn Achieved N/A SFD (mm) 400 SOD (mm) 365 Pipe OD (mm) 35
Image Evaluation
Comparator Present: Grey scale/density of image acceptable:
Comparator ovalness ≤3% of
Comparator Blow-up <20%: Grey Scale < 90% of Saturation:
measured ball diameter:
Lead B/S Control Present: Grey Scale Count Left on Image:

Comparator Ball 10/20mm: SAL ID: 24041 Duplex Serial Number: N/A

Step Wedge: SAL ID: N/A Lead B/S Control Result: N/A

Inspection Results
Test Point Shot Nominal Minimum
Comments Location
No. No/Pitch W/T W/T

PLEASE SEE BELOW TABLE FOR RESULTS AND


COMMENTS.

Technician (Print) Technician Signature Qualifications Date


Jan Zavacky PCN L2 - 317836 02/05/2022
Client (Print) Client Signature Management Approval

Bilfinger Salamis UK Ltd, 4 Greenhole Place, Bridge of Don, Aberdeen, AB23 8EU | Tel: +44 1224 246000

Inspection NDT SAL-INP-NDT-TEM-003 V 2 Application as from 21/12/2021Applicable Procedure Ref MulitiplePage


UNCONTROLLED
1 of 2 IF PRINTED
Radiography Corrosion Assessment Inspection Report

Continuation Page
Client INEOS Report No. BIS-DK-RT-1052
Inspection Results

CML ID Norsk Fresh WT Min. WT EWL TWL


Line
Line Destription Nominal Measured Measured CAT. (A- CAT (A- Comments
Size [in]
WT [mm] [mm] [mm] E) F)

N1A 1210-72-VN01 - Foam Tank 2" 2.77 3.58 3.48 B A No Concerns.


N1B 1210-72-VN01 - Foam Tank 2" 2.77 4.48 4.11 C A No Concerns.