Page A-18 PW1660 Service Manual 910712 “The top part of the display shows the software version number and the fields containing the system dentification/serial ‘number and flow gas/anode parameters. These four fields are editable, ‘The group of four fields in the middle of the screen are all set by the state of the spectrometer's intemal switches. “The lower four fields define the status of /O ports 2-4, Port 1 is always connected to the local VDU/computer. The “Second contro!" (Remote Diagnostics) field is set automatically according to the state of the ‘Run/Test’ switch on the system control board. The middle two of these fields are fixed as the functions on the lett are always allocated to these ports. ‘The final field can be edited to reflect the port to which the status screen is connected. As the status screen can be connected to any available port. A.4.3.2 Fixed Channels - Scalers ‘This form mustbe filedin for each scaler fitted to the spectrometer. Itcontains information on the fixed channel parame- tors and internal connections to the scaler boards. These can be filedin with the aid of the configuration sheets and the table of fixed channels given in Section 1.6. A typical screen is shown below. oO tt a programmable goniometer is present, scaler 1 is automatically reserved for it. In this case, no Line and Energy information can be entered here. Ha channel is deleted, itis also automatically deleted from the measuring program (if it was assembled there). FIXED CHANNELS ~ SCALERS 26-may 88 10:19:05 Sc. Ch Line Energy Take-off Crystal 2d Detector Q-norm no. (keV) angle type (nm) type wdw 2 GON 25 Lir200 Seint. 200 120 2 Na Ka 1,042 40, TIAP Flow 2 45 3 Mg Ka 1.253 25 TIAP Flow 2 45 a al ka 40, PE Neon 25 48 5S Si Ka 1.915 40 InSb Neon 25 48 6 F Ka 2.200 25 Ge Neon 25 48 7s Ka 2.307 40 Ge Neon 50 48 8 cl Ka 2.621 25 Ge Neon 50 48 9K Ka 31555 25 TAF 200 Krypton100 54 10 Ca Ka 3.690 40 Lir200 Krypton100 54 11 Ti Ka 4508 40 Lir200 Krypton100 54 S 120 Mn Ka 5.894 25 Lir200 Krypton100 54 130 Fe Ka (6.398 25 Lir200 Krypton100 54 14 (print, Edit, / 1: / Normal input parameters are: 1. Channel name (Ch), these are one or two letters codes, which can be followed by the numbers!,2.0r 3. 2. Xray line (Line) 3. Energy (Kev) ‘Channelsin the lower row of the hemispherical measuring chamber are mounted at a take off angle of 25° with respect to the sample; while, Channels in the upper row are mounted at a take off angle of 40° with respect to the sample. “The crystal type, 2d value of erystal in nm, detector type and window thickness in nm and the Q-norm of the detector must also be edited. ¢

You might also like