The air- conditioning system provides a continuous renewal of air and keeps a
constant selected temperature in the independently controlled zones:
- Flight deck
- FWD cabin
CKPT FWD MID AFT
- MID cabin
- AFT cabin
- FWD compt
- BULK compt
Ambient air from the cabin are regulated temperature before entering the cargo
compartments (except AFT cargo) via inlet isolation valves and extracted to overboard
by extract fan via outlet isolation valves.
enter
out
PACK 2
PACK 1
A temperature control valve is Both packs operates automatically The conditioned air from the
fitted and can modify the pack and independently.Pack operation packs is then fed to a mixer
outlet temperature by adding is controlled by the pack unit.
uncooled air to the turbine outlet controller.
flow.
Air Conditioning-Flt Deck/Cabin Zone
Mixer Unit
To avionic ventilation
CKPT FWD MID AFT
CAB FAN
Mixer Unit
Recirculation valves
PACK 1 PACK 2
Cold fresh air from the packs is mixed with recirculated cabin air and
sent to the three cabin zones.
Note : Cockpit zone is supplied by fresh air only.(Refer to FCOM
1.21.10 p2)
Air Conditioning-Flt Deck/Cabin Zone
Zone Temp
Hot Air Valves Trim Air Valve
Pneumatic
operated
มาจาก Eng/APUElectric Controlled
Bleed เป็นไลน์ที่ CKPT FWD MID AFT
แยกออกมาก่อน 20 0 20 0 22 0 25 0
เข้า Pack Duct (ท่อ) Temp
22 0 22 0 22 0 25 0 25 0 27 0 27 0
เรียกว่า Tr
Hot Air Valve
Mixing Unit
PACK 1 PACK 2
HOT Cross Valve ทํางานออโต้ ไม่มีปุ่มให้นักบินเลือก ปกติแล้วจะปิ ด จะ HOT
AIR 1 เปิ ดเมื่อ Hot Air Supply Fail 1 ข้าง AIR 2
They provide hot air to trim air system for optimized temp regulation.
They regulate the pressure of hot air tapped upstream of the packs.
Mixing Unit
PACK 1 PACK 2
HOT HOT
AIR 1 AIR 2
Installed between both hot air manifolds.
Normally valve closed (valve open when hot air supply failure ex.one pack overheat)
Air Conditioning-Flt Deck/Cabin Zone
Mixing Unit
PACK 1 PACK 2
HOT HOT
AIR 1 AIR 2
Hot bleed air can be added via trim air valve to achieve the demanded
temperature for a zone.
Mixing Unit
Each pack controllers regulates the air flow and temperature of its related pack in accordance with a
demand signal from the zone controller.
It modulates its temperature control valve and the ram air inlet and outlet flaps.
Air Conditioning-Flt Deck/Cabin Zone
Mixing Unit
A Zone controller monitors the temperature of the four zones and sends signals to the pack controllers
to set the air temperature delivered by the packs.
Zone controller controls the trim air valve to added hot bleed air for demanded temperature in each zone.
Air Conditioning-Control and Indication
Normally green.
Becomes amber if the
temperature is above
limits.
air condition
pack operation
The upper part of ECAM COND page displays FLT DECK/CABIN air condition parameters.
Air Conditioning-Control and Indication
Zone temperature
ECAM COND Page
Displayed in green.
Zone duct temperature
Also displayed on the
ECAM CRUISE page.
Normally green.
Becomes amber
above limits.
Hot air X valve indication
Zone Temp
Cargo
Compartment
The ECAM CRUISE page also displays the zone temperature indications.
Air Conditioning-Control and Indication
24 deg cel + - ขีดละ
18
2 30
AIR Panel in cabin
มีแผงปรับอุณที่เคบิน
แต่จะแอคทีฟ ใน
Cruise Phase เท่านั ้น
Gnd Air (LP GND
Air) จะมาเสียบตรงนี ้เลย
แต่จะไม่มีอินดิเคอร์บอกเลย
รู้ ได้จากความเย็น
Gnd Pneumatic จะมี
ตัวบอก (HP Gnd Air)
(ดูสไลด์ Pneumatic
หน้ า 10)
Air Conditioning-Control and Indication
AIR Panel
AIR Panel
Air Conditioning-Control and Indication
AIR Panel
Air Conditioning-Control and Indication
AIR Panel
Air Conditioning-Control and Indication
PACK FLOW selector Zone temperature selector
AIR Panel
Permits the selection Adjusts the temperature
of pack flow according for the associated zone.
to the number of
passengers and
ambient conditions.
RAM AIR inlet is closed. Hot air pressure valve and Valve closed.
trim air valves closed.
RAM AIR inlet is open.
Duct overheat is detected. Valve position disagree
or overheat.
Air Conditioning-Flt Deck/Cabin Zone
VENTILATION Panel
To avionic ventilation
CAB FAN
Mixer Unit
Recirculation valves
PACK 1 PACK 2
CAB FANS pb sw
OVERBOARD
FWD
ปุ่มบนovrhd panel เมื่อselect off จะตัดการ
ทำงานทั้งพัดลมและboth inlet/outlet isol
valveเลย
Ventilation:
Inlet Isolation Ambient air from the cabin area enters
Valve the forward cargo compartment via
two inlet isolation valves and is ducted
through the extract fan and the outlet
Cabin Cabin
isolation valve to overboard.
Ambient Air Ambient Air
Air Conditioning-Cargo Zone
ก่อนจะเอาออกไปoverboard จะต้องไปผ่าน
กระบวนการpressurizeก่่อน
OVERBOARD
FWD
Cooling:
To decrease the compartment
temperature, the cabin ambient air is
mixed with cold air from the
Cold air valve
downstream of pack 2 via a cold air
valve. This valve has three positions
Cold Air (fully closed, partially open, fully open).
Cabin Cabin
Ambient Air Ambient Air
ปรับที่ Cargo Air
Cond Panel ดูหน้ า
38
Air Conditioning-Cargo Zone
OVERBOARD
FWD
Heating:
To provide compartment heating, hot
bleed air from upstream of pack 1 is
Trim air valve supplied via a trim air valve.
OVERBOARD
AFT
OVERBOARD
BULK
Inlet Isolation
Valve This compartment have two subsystems :
Ventilation+Heating
ELECTRICAL Ventilation:
FAN HEATER
Air from the cabin is ducted through
only one isolation valve and extracted
by the fan is directed through the
outlet isolation valve to overboard.
Cabin
Ambient Air
Air Conditioning-Cargo Zone
OVERBOARD
BULK
Inlet Isolation
Valve This compartment have two subsystems :
Ventilation+Heating
ELECTRICAL Heating:
FAN HEATER
Compartment heating is performed by
an electrical fan heater.
The lower part of ECAM COND page displays CARGO air condition parameters.
Air Conditioning-Control and Indication
Compartment indication
ECAM COND Page
The indication is always
white.
Duct temperature
Compartment temperature
Normally green.
Becomes amber when the The indication is always
temperature is above green.
limits.
A A Normally fully open. Normally partially open. B The indication is green when
B the two pack flow control
Normally fully closed. valves are open. It becomes
Abnormally partially
amber when one of the two
Abnormally fully closed. open or in transit.
valves is fully closed.
C
Abnormally fully closed. C The indication is always white.
Air Conditioning-Control and Indication
คนละอันกันกับ Cabin/
CARGO AIR COND Panel Cockpit
มันเป็ นฮีทเตอร์
Note: The isolation valves and extract fans are not presented on the ECAM page.
Air Conditioning-Control and Indication
COLD AIR
controller(เอามา
จากแพค1)
คนละอันกับ Cabin/
cockpit
อันนี ้นักบินคุมได้
Air Conditioning-Control and Indication
Cockpit Preparation
Engine Start
Before Takeoff
Note
Use TOGA thrust : APU bleed On or PACKS OFF will improve performance.
Use FLEX takeoff: APU bleed On or PACKS OFF will reduce takeoff EGT and
thus reduce maintenance costs.
Air Conditioning-Normal Operation
Takeoff
Cruise