The document summarizes a toolbox talk on paint preparation and mixing requirements for offshore hook up, upgrade modification, and SCADA installation projects. It discusses safely mixing coatings in a ventilated area using protective equipment. Paints must not be gelled or partially mixed, and skins must be removed from containers. All paints must be thoroughly power mixed until homogeneous before application, without excessive thinning, as outlined in Saudi Aramco standards SAES-H-004.
The document summarizes a toolbox talk on paint preparation and mixing requirements for offshore hook up, upgrade modification, and SCADA installation projects. It discusses safely mixing coatings in a ventilated area using protective equipment. Paints must not be gelled or partially mixed, and skins must be removed from containers. All paints must be thoroughly power mixed until homogeneous before application, without excessive thinning, as outlined in Saudi Aramco standards SAES-H-004.
The document summarizes a toolbox talk on paint preparation and mixing requirements for offshore hook up, upgrade modification, and SCADA installation projects. It discusses safely mixing coatings in a ventilated area using protective equipment. Paints must not be gelled or partially mixed, and skins must be removed from containers. All paints must be thoroughly power mixed until homogeneous before application, without excessive thinning, as outlined in Saudi Aramco standards SAES-H-004.
Start Time:06:00 AM TBT Log No :TBQM-OMAR-COAT-023
Meeting Duration:30 Minutes Number of Attendees: 4
Topics Discussed:
PAINT PREPARATION AND MIXING REQUIREMENTS
(SAES-H-004, SECTION 5.3 & 9.4)
TBT Log No: TBQM-OMAR-COAT-023 Page 1
PAINT PREPARATION AND MIXING REQUIREMENTS
1. Coatings shall be mixed in an open area or in an adequately ventilated
area. Use eye protection (goggles), respirators, protective gloves and other safety equipment as per SAES-H-004 Para 5.4.4.1.
2. Gelled paints shall not be used as per SAES-H-004 Para 9.3.1.
3. Coating skins shall be removed in recently opened and or partially used
containers. If any skinning is found on previously unopened paint, the cans shall be set aside and not used as per SAES-H-004 Para 9.3.2.
4. Prior to application, all paint shall be thoroughly mixed until it is
homogeneous. Excessive amount of thinning shall not be used. Excessive thinning is defined as any amount of thinning in excessive of the coating manufacturer's recommendation. For quantities over 5L, a power stirrer shall be used. If sludge has formed in the bottom of the paint container, stirring to mix shall be continued until the paint is fully homogeneous mix. If sludge cannot be dispersed, the paint shall not be used as per SAES-H-004 Para 9.3.3.
5. Partial mixing in a two-component and multi-component coatings is
prohibited as per SAES-H-004 Para 9.3.4.
6. If thinning is required, the thinner type and quantity to be added shall
be as given in the Saudi Aramco Data Sheet (SAES-H-002V/SAES-H- 101V). All paints in quantities over 5 liter shall be mixed with a power stirrer/mixer during adding the thinner. Thinner shall be added only when the paint is fully homogeneous mix as per SAES-H-004 Para 9.3.5.