PVsyst - Simulation report
Standalone system
Project: SUCUMBIOS
Variant: Nueva variante de simulación
Standalone system with batteries
System power: 31.1 kWp
PVsyst TRIAL
SUCUMBIOS(Teteyé) - Ecuador
PVsyst TRIAL
PVsyst TRIAL
Author
PVsyst TRIAL
Project: SUCUMBIOS
Variant: Nueva variante de simulación
PVsyst V7.4.0
VC0, Simulation date:
21/08/23 23:01
PVsyst TRIAL
with v7.4.0
Project summary
Geographical Site Situation Project settings
SUCUMBIOS(Teteyé) Latitude -0.02 °S Albedo 0.20
Ecuador Longitude -76.76 °W
Altitude 269 m
Time zone UTC-5
Meteo data
SUCUMBIOS(Teteyé)
NREL NSRDB Typ. Met. Year PSMv3_1998 to 2020 - TMY
System summary
PVsyst TRIAL
Standalone system Standalone system with batteries
System information
PV Array Battery pack
Nb. of modules 115 units Technology Lead-acid, sealed, Gel
Pnom total 31.1 kWp Nb. of units 640 units
Voltage 96 V
Capacity 4240 Ah
Results summary
PVsyst TRIAL
Useful energy from solar 31590 kWh/year
Missing Energy
Excess (unused)
0 kWh/year
4284 kWh/year
Table of contents
Solar Fraction SF
68.28 %
100.00 %
2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7
PVsyst TRIAL
PVsyst TRIAL
21/08/23 PVsyst Evaluation mode Page 2/7
Project: SUCUMBIOS
Variant: Nueva variante de simulación
PVsyst V7.4.0
VC0, Simulation date:
21/08/23 23:01
PVsyst TRIAL
with v7.4.0
General parameters
Standalone system Standalone system with batteries
PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 30 / 0 ° Diffuse Imported
Circumsolar separate
User's needs
Daily household consumers
Constant over the year
Average 87 kWh/Day
PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 270 Wp
PV Array Characteristics
Generic
END-60-270P
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
12V 1 RES OPzV 65
Lead-acid, sealed, Gel
80 in parallel x 8 in series
Number of PV modules 115 units Discharging min. SOC 20.0 %
Nominal (STC) 31.1 kWp Stored energy 325.6 kWh
Modules 23 Strings x 5 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 96 V
Pmpp 27.56 kWp Nominal Capacity 4240 Ah (C10)
U mpp 137 V Temperature Fixed 20 °C
I mpp 201 A
PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.
97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
approx.
Discharging
approx.
SOC calculation
SOC = 0.90 / 0.75
107.9 / 100.3 V
SOC = 0.20 / 0.45
93.7 / 97.7 V
Total PV power
Nominal (STC) 31 kWp
Total 115 modules
Module area 188 m²
Cell area 169 m²
Array losses
PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)
-0.8 %
DC wiring losses
Global array res.
Loss Fraction
2.0 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction
0.2 %
PVsyst TRIAL
21/08/23 PVsyst Evaluation mode Page 3/7
Project: SUCUMBIOS
Variant: Nueva variante de simulación
PVsyst V7.4.0
VC0, Simulation date:
21/08/23 23:01
PVsyst TRIAL
with v7.4.0
PVsyst TRIAL
Total daily energy 86548
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
21/08/23 PVsyst Evaluation mode Page 4/7
Project: SUCUMBIOS
Variant: Nueva variante de simulación
PVsyst V7.4.0
VC0, Simulation date:
21/08/23 23:01
PVsyst TRIAL
with v7.4.0
Main results
System Production
Useful energy from solar 31590 kWh/year Perf. Ratio PR 68.28 %
Available solar energy 37421 kWh/year Solar Fraction SF 100.00 %
Excess (unused) 4284 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 0.0 % Cycles SOW 97.3 %
Missing Energy 0 kWh/year Static SOW 93.3 %
PVsyst TRIAL
Balances and main results
PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
143.6
125.0
134.4
135.0
GlobEff
kWh/m²
101.7
99.0
117.9
130.4
E_Avail
kWh
2659
2584
3046
3355
EUnused
kWh
0.0
0.0
74.1
575.3
E_Miss
kWh
0.000
0.000
0.000
0.000
E_User
kWh
2683
2423
2683
2596
E_Load
kWh
2683
2423
2683
2596
SolFrac
ratio
1.000
1.000
1.000
1.000
May 123.6 126.7 3284 461.5 0.000 2683 2683 1.000
June 120.1 128.2 3336 611.2 0.000 2596 2596 1.000
July 124.3 130.1 3373 543.4 0.000 2683 2683 1.000
August 137.4 136.6 3510 663.2 0.000 2683 2683 1.000
September 155.1 140.1 3579 839.9 0.000 2596 2596 1.000
October 153.9 124.7 3209 388.5 0.000 2683 2683 1.000
November 147.7 107.5 2798 126.9 0.000 2596 2596 1.000
PVsyst TRIAL
December 150.7 102.7 2690 0.0 0.000 2683 2683 1.000
Year 1650.7 1445.7 37421 4284.0 0.000 31590 31590 1.000
Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy
PVsyst TRIAL
21/08/23 PVsyst Evaluation mode Page 5/7
Project: SUCUMBIOS
Variant: Nueva variante de simulación
PVsyst V7.4.0
VC0, Simulation date:
21/08/23 23:01
PVsyst TRIAL
with v7.4.0
Loss diagram
1651 kWh/m² Global horizontal irradiation
PVsyst TRIAL
-0.76% PV loss due to irradiance level
PVsyst TRIAL
-4.67% Converter Loss during operation (efficiency)
31590 kWh
Energy supplied to the user
PVsyst TRIAL
21/08/23 PVsyst Evaluation mode Page 6/7
Project: SUCUMBIOS
Variant: Nueva variante de simulación
PVsyst V7.4.0
VC0, Simulation date:
21/08/23 23:01
PVsyst TRIAL
with v7.4.0
Predef. graphs
Diagrama entrada/salida diaria
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
21/08/23 PVsyst Evaluation mode Page 7/7