Professional Documents
Culture Documents
PVsyst TRIAL
Project: Automat Vanzare
Variant: New simulation variant with 2 pannels
Stand alone with back-up generator
System power: 570 Wp
Bucharest - Romania
PVsyst TRIAL
PVsyst TRIAL
PVsyst V7.1.4
VC2, Simulation date:
03/02/21 22:26
with v7.1.4
Project summary
Geographical Site Situation Project settings
Bucharest Latitude 44.50 °N Albedo 0.20
Romania Longitude 26.22 °E
Altitude 81 m
PVsyst TRIAL
Time zone UTC+1
Meteo data
Chur
Meteonorm 7.1 (1991-2010) - Synthetic
System summary
Stand alone system Stand alone with back-up generator
PVsyst TRIAL
System information
PV Array Battery pack
Nb. of modules 2 units Technology Lead-acid, sealed, Gel
Pnom total 570 Wp Nb. of units 5 units
Voltage 12 V
Capacity 800 Ah
Results summary
Available Energy 710.7 kWh/year Specific production 1247 kWh/kWp/year Perf. Ratio PR 68.15 %
Used Energy 644.1 kWh/year Solar Fraction SF 89.24 %
Table of contents
Project and results summary 2
PVsyst TRIAL
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 5
Main results 6
Loss diagram 7
Special graphs 8
Predef. graphs 9
Cost of the system 11
PVsyst TRIAL
03/02/21 PVsyst Evaluation mode Page 2/11
Project: Automat Vanzare
Variant: New simulation variant with 2 pannels
PVsyst V7.1.4
VC2, Simulation date:
03/02/21 22:26
with v7.1.4
General parameters
Stand alone system Stand alone with back-up generator
PVsyst TRIAL
Fixed plane Transposition Perez Constant over the year
Tilt/Azimuth 30 / 0 ° Diffuse Perez, Meteonorm Average 1.8 kWh/Day
Circumsolar separate
PV Array Characteristics
PV module Battery
Manufacturer Generic Manufacturer Generic
Model Poly 285 Wp 72 cells Model Solar 12V / 160 Ah
(Original PVsyst database) Technology Lead-acid, sealed, Gel
Unit Nom. Power 285 Wp Nb. of units 5 in parallel
Number of PV modules 2 units Discharging min. SOC 20.0 %
Nominal (STC) 570 Wp Stored energy 7.7 kWh
Modules 2 Strings x 1 In series Battery Pack Characteristics
Voltage 12 V
PVsyst TRIAL
At operating cond. (50°C)
Pmpp 516 Wp Nominal Capacity 800 Ah (C10)
U mpp 33 V Temperature External ambient temperature
I mpp 16 A
Back-up genset
Manufacturer Generic
PVsyst TRIAL
Model 1.5 kW
Nominal power 1.5 kW
Effective power 1.0 kW
Total PV power
Nominal (STC) 1 kWp
Total 2 modules
Module area 3.9 m²
Cell area 3.5 m²
Array losses
Thermal Loss factor DC wiring losses Serie Diode Loss
Module temperature according to irradiance Global array res. 35 mΩ Voltage drop 0.7 V
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC Loss Fraction 1.9 % at STC
PVsyst TRIAL
Uv (wind) 0.0 W/m²K/m/s
PVsyst V7.1.4
VC2, Simulation date:
03/02/21 22:26
with v7.1.4
Array losses
IAM loss factor
Incidence effect (IAM): Fresnel smooth glass, n = 1.526
PVsyst TRIAL
1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
03/02/21 PVsyst Evaluation mode Page 4/11
Project: Automat Vanzare
Variant: New simulation variant with 2 pannels
PVsyst V7.1.4
VC2, Simulation date:
03/02/21 22:26
with v7.1.4
PVsyst TRIAL
W Hour/day Wh/day
Lamps (LED or fluo) 1 3W/lamp 3.0 9
Fridge / Deep-freeze 1 24 1420
electromag 1 3W tot 8.0 24
Controlers 1 12W tot 24.0 288
Stand-by consumers 24.0 24
Total daily energy 1765Wh/day
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
03/02/21 PVsyst Evaluation mode Page 5/11
Project: Automat Vanzare
Variant: New simulation variant with 2 pannels
PVsyst V7.1.4
VC2, Simulation date:
03/02/21 22:26
with v7.1.4
Main results
System Production
Available Energy 710.7 kWh/year Specific production 1247 kWh/kWp/year
Used Energy 644.1 kWh/year Performance Ratio PR 68.15 %
Excess (unused) 123.9 kWh/year Solar Fraction SF 89.24 %
PVsyst TRIAL
Back-Up energy from generator Battery aging (State of Wear)
Back-Up energy 69.2 kWh/year Cycles SOW 97.1 %
Fuel Consumption 42 liter/year Static SOW 90.1 %
Battery lifetime 10.1 years
PVsyst TRIAL
Balances and main results
PVsyst TRIAL
April 141.1 147.8 74.09 19.22 52.93 52.95 1.000
May 168.3 160.7 77.99 21.96 54.70 54.72 1.000
June 177.2 162.4 78.97 24.29 52.93 52.95 1.000
July 177.4 164.7 79.62 22.94 54.69 54.72 1.000
August 150.9 153.9 74.02 17.77 54.69 54.72 1.000
September 111.0 126.8 61.57 7.63 52.94 52.95 1.000
October 77.7 103.7 51.94 0.00 54.71 54.72 0.962
November 41.5 62.7 31.71 0.00 52.96 52.95 0.682
December 31.9 56.7 29.67 0.00 54.72 54.72 0.492
Year 1289.2 1430.4 710.66 123.85 644.12 644.23 0.892
Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
PVsyst TRIAL
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
PVsyst V7.1.4
VC2, Simulation date:
03/02/21 22:26
with v7.1.4
Loss diagram
1289 kWh/m² Global horizontal irradiation
+14.8% Global incident in coll. plane
PVsyst TRIAL
-3.35% IAM factor on global
PVsyst TRIAL
-2.95% Ohmic wiring loss
PVsyst TRIAL
69.2 kWh Battery Storage
Direct use Stored -0.32% Battery Stored Energy balance
32.1% 67.9%
-1.12% Battery efficiency loss
PVsyst TRIAL
03/02/21 PVsyst Evaluation mode Page 7/11
Project: Automat Vanzare
Variant: New simulation variant with 2 pannels
PVsyst V7.1.4
VC2, Simulation date:
03/02/21 22:26
with v7.1.4
Special graphs
Daily Input/Output diagram
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
03/02/21 PVsyst Evaluation mode Page 8/11
Project: Automat Vanzare
Variant: New simulation variant with 2 pannels
PVsyst V7.1.4
VC2, Simulation date:
03/02/21 22:26
with v7.1.4
Predef. graphs
Reference Incident Energy in Collector Plane
PVsyst TRIAL
PVsyst TRIAL
Daily Array Output Energy
PVsyst TRIAL
PVsyst TRIAL
03/02/21 PVsyst Evaluation mode Page 9/11
Project: Automat Vanzare
Variant: New simulation variant with 2 pannels
PVsyst V7.1.4
VC2, Simulation date:
03/02/21 22:26
with v7.1.4
Predef. graphs
Array Power Distribution
PVsyst TRIAL
PVsyst TRIAL
State of charge daily distribution
PVsyst TRIAL
PVsyst TRIAL
03/02/21 PVsyst Evaluation mode Page 10/11
Project: Automat Vanzare
Variant: New simulation variant with 2 pannels
PVsyst V7.1.4
VC2, Simulation date:
03/02/21 22:26
with v7.1.4
PVsyst TRIAL
Total 0.00
Depreciable asset 0.00
Operating costs
Item Total
EUR/year
Fuel for Back-Up generator 49.82
Total (OPEX) 49.82
System summary
Total installation cost 0.00 EUR
PVsyst TRIAL
Operating costs 49.82 EUR/year
Excess energy (battery full) 124 kWh/year
Used solar energy 644 kWh/year
Used energy cost 0.077 EUR/kWh
PVsyst TRIAL
PVsyst TRIAL
03/02/21 PVsyst Evaluation mode Page 11/11