You are on page 1of 7

Version 7.2.

16

PVsyst NGO project


PVsyst - Simulation report
Stand alone system

Project: TEST PAF


Variant: Nouvelle variante de simulation
Stand alone system with batteries

PVsyst NGO project


System power: 4800 Wp
Albarkaïzé - Niger

PVsyst NGO project

PVsyst NGO project

Author

PVsyst NGO project


Project: TEST PAF
Variant: Nouvelle variante de simulation

PVsyst V7.2.16
VC2, Simulation date:
15/06/23 14:48

PVsyst NGO project


with v7.2.16

Geographical Site Situation


Project summary
Project settings
Albarkaïzé Latitude 12.07 °N Albedo 0.20
Niger Longitude 3.22 °E
Altitude 163 m
Time zone UTC+1

Meteo data
Albarkaïzé
Meteonorm 8.0 (1986-2005), Sat=100 % - Synthétique

System summary

PVsyst NGO project


Stand alone system

PV Field Orientation
Fixed plane
Tilt/Azimuth 12 / 0 °
Stand alone system with batteries

User's needs
Daily household consumers
Constant over the year
Average 27.8 kWh/Day

System information
PV Array Battery pack
Nb. of modules 16 units Technology Lithium-ion, NMC
Pnom total 4800 Wp Nb. of units 5 units
Voltage 52 V
Capacity 1288 Ah

Results summary

PVsyst NGO project


Available Energy
Used Energy
7620 kWh/year
7456 kWh/year
Specific production 1588 kWh/kWp/year Perf. Ratio PR

Table of contents
Solar Fraction SF
73.21 %
73.42 %

Project and results summary 2


General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Special graphs 7

PVsyst NGO project

PVsyst NGO project


05/07/23 PVsyst NGO project License, Page 2/7
Project: TEST PAF
Variant: Nouvelle variante de simulation

PVsyst V7.2.16
VC2, Simulation date:
15/06/23 14:48

PVsyst NGO project


with v7.2.16

Stand alone system


General parameters
Stand alone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 12 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 27.8 kWh/Day

PVsyst NGO project


PV module
Manufacturer
PV Array Characteristics

JA Solar
Battery
Manufacturer LG Chem
Model JAM6-72-300 Model RESU 13 12.4 kWh
(Original PVsyst database) Technology Lithium-ion, NMC
Unit Nom. Power 300 Wp Nb. of units 5 in parallel
Number of PV modules 16 units Discharging min. SOC 10.0 %
Nominal (STC) 4800 Wp Stored energy 60.5 kWh
Modules 8 Strings x 2 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 52 V
Pmpp 4283 Wp Nominal Capacity 1288 Ah (C10)
U mpp 66 V Temperature Fixed 40 °C

PVsyst NGO project


I mpp 65 A

Controller Battery Management control


Universal controller Threshold commands as SOC calculation
Technology MPPT converter Charging SOC = 0.96 / 0.80
Temp coeff. -5.0 mV/°C/Elem. Discharging SOC = 0.10 / 0.35
Converter
Maxi and EURO efficiencies 97.0 / 95.0 %

Total PV power
Nominal (STC) 4.80 kWp
Total 16 modules
Module area 31.0 m²
Cell area 27.5 m²

PVsyst NGO project


Array losses
Thermal Loss factor DC wiring losses Serie Diode Loss
Module temperature according to irradiance Global array res. 17 mΩ Voltage drop 0.7 V
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC Loss Fraction 0.9 % at STC
Uv (wind) 0.0 W/m²K/m/s

Module Quality Loss Module mismatch losses Strings Mismatch loss


Loss Fraction 1.5 % Loss Fraction 2.0 % at MPP Loss Fraction 0.1 %

IAM loss factor


ASHRAE Param.: IAM = 1 - bo (1/cosi -1)
bo Param. 0.05

PVsyst NGO project


05/07/23 PVsyst NGO project License, Page 3/7
Project: TEST PAF
Variant: Nouvelle variante de simulation

PVsyst V7.2.16
VC2, Simulation date:
15/06/23 14:48

PVsyst NGO project


with v7.2.16

Detailed User's needs


Daily household consumers, Constant over the year, average = 27.8 kWh/day
Annual values Hourly distribution

Number Power Use Energy


W Hour/day Wh/day
Lampes LED 10 24W/lamp 11.0 2640
TV / PC / Mobile 3 100W/app 11.0 3300
Appareils domestiques 2 500W/app 7.0 7000
Frigo / Congélateur 2 12 3199
Ordinateur 4 350W tot 8.0 11200
Consomm. de veille 24.0 480

PVsyst NGO project


Total daily energy 27819Wh/day

PVsyst NGO project

PVsyst NGO project

PVsyst NGO project


05/07/23 PVsyst NGO project License, Page 4/7
Project: TEST PAF
Variant: Nouvelle variante de simulation

PVsyst V7.2.16
VC2, Simulation date:
15/06/23 14:48

PVsyst NGO project


with v7.2.16

System Production
Main results

Available Energy 7620 kWh/year Specific production 1588 kWh/kWp/year


Used Energy 7456 kWh/year Performance Ratio PR 73.21 %
Excess (unused) 0 kWh/year Solar Fraction SF 73.42 %
Loss of Load Battery aging (State of Wear)
Time Fraction 22.6 % Cycles SOW 99.2 %
Missing Energy 2700 kWh/year Static SOW 71.7 %
Battery lifetime 3.5 years

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst NGO project

PVsyst NGO project GlobHor


kWh/m²
GlobEff
kWh/m²
Balances and main results

E_Avail
kWh
EUnused
kWh
E_Miss
kWh
E_User
kWh
E_Load
kWh
SolFrac
ratio
January 156.5 169.1 632.3 0.017 213.0 649.6 862.5 0.753
February 151.2 156.9 569.4 0.069 235.5 543.6 779.1 0.698
March 183.1 183.6 651.9 0.017 220.9 641.6 862.5 0.744
April 190.3 184.1 653.9 0.000 199.1 635.6 834.7 0.761
May 188.7 175.6 640.0 0.000 241.2 621.3 862.5 0.720
June 182.7 167.0 623.5 0.049 218.8 615.9 834.7 0.738
July 191.1 174.9 657.2 0.000 215.0 647.5 862.5 0.751
August 168.4 159.1 603.2 0.000 284.5 578.0 862.5 0.670
September 174.1 172.2 643.3 0.017 207.9 626.8 834.7 0.751
October 181.1 187.3 686.9 0.000 183.9 678.7 862.5 0.787

PVsyst NGO project


November
December
Year
164.7
148.4
2080.2
178.2
161.2
2069.2
653.2
605.3
7620.1
0.000
0.000
0.169
190.8
289.2
2699.8
644.0
573.3
7456.0
834.7
862.5
10155.8
0.771
0.665
0.734

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst NGO project


05/07/23 PVsyst NGO project License, Page 5/7
Project: TEST PAF
Variant: Nouvelle variante de simulation

PVsyst V7.2.16
VC2, Simulation date:
15/06/23 14:48

PVsyst NGO project


with v7.2.16

2080 kWh/m²
Loss diagram

Global horizontal irradiation


+2.0% Global incident in coll. plane

-2.47% IAM factor on global

2069 kWh/m² * 31 m² coll. Effective irradiation on collectors

efficiency at STC = 15.48% PV conversion

9935 kWh Array nominal energy (at STC effic.)

PVsyst NGO project


-0.26% PV loss due to irradiance level

-14.95% PV loss due to temperature

-1.50% Module quality loss

-2.10% Mismatch loss, modules and strings

-2.30% Ohmic wiring loss


0.00% Unused energy (battery full)
7940 kWh Effective energy at the output of the array

-4.00% Converter Loss during operation (efficiency)

-0.04% Converter Loss due to power threshold

PVsyst NGO project


Missing energy

26.58% 7620 kWh


Direct use Stored
0.00%
0.00%
Converter Loss over nominal conv. voltage
Converter Loss due to voltage threshold
Converter losses (effic, overload)
Battery Storage
61.0% 39.0%
-0.06% Battery Stored Energy balance
-1.46% Battery efficiency loss
-1.49% Charge/Disch. Current Efficiency Loss
-0.64% Battery Self-discharge Current
2700 kWh 7456 kWh Energy supplied to the user

10156 kWh Energy need of the user (Load)

PVsyst NGO project

PVsyst NGO project


05/07/23 PVsyst NGO project License, Page 6/7
Project: TEST PAF
Variant: Nouvelle variante de simulation

PVsyst V7.2.16
VC2, Simulation date:
15/06/23 14:48

PVsyst NGO project


with v7.2.16

Special graphs
Diagramme d'entrée/sortie journalier

PVsyst NGO project

PVsyst NGO project

PVsyst NGO project

PVsyst NGO project


05/07/23 PVsyst NGO project License, Page 7/7

You might also like